marlow
industries
Subsidiary of II-VI Incorporated
a global leader in thermoelectric solutions
Thermoelectric Cooler NL1023T
Performance Values
Hot Side Temperature (°C) Δ Tmax (°C-dry N2): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27°C 64 9.2 1.8 8.0 3.86 50°C 73 10.5 1.8 9.0 ---
RoHS 2002/95/EC Compliant
Mechanical Characteristics
Positive Lead
.518 [13.16]
Leads: 28 AWG (0.32) Bus Solid Tinned Copper Negative Lead
.518 [13.16]
2.00 +/-.25 [50.80+/-6.35]
.085+/-.005 [2.16 +/-0.13]
Cold Side
.005 [0.13] .001 [0.03] .001 [0.03]
A
Ceramic Material: Alumina (AC) Millimeters are in [ ]
A
Ordering Options
Model Number NL1023T-01 NL1023T-02 NL1023T-03 Description both surfaces are metallized hot side exterior is metallized no metallization
Features
• • RoHS 2002/95/EC compliant For example, and NL1023T with only the hot side metallized is specified as an NL1023T-02AC
Available Modifications
• • • Pretinned metallized ceramic surface(s) with 117°C solder. Thermistor mounted on edge of cold side ceramic. (Calibration available.) Elevated temperature burn-in with test data provided. Doc # 102-0297 Rev B
Page 1 of 2
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
marlow
industries
Subsidiary of II-VI Incorporated
a global leader in thermoelectric solutions
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C HEAT LOAD (WATTS) 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 Hot Side Temperature: 50°C HEAT LOAD (WATTS) 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00
80.0 60.0 T (C) 40.0 20.0 0.0 VOLTAGE (VDC) 8.0 6.0 4.0 2.0 0.0 0.0 0.4 0.8 1.2 1.6 CURRENT (AMPS)
80.0 60.0 T (C) VOLTAGE (VDC) 40.0 20.0 0.0 8.0 6.0 4.0 2.0 0.0 0.0 0.4 0.8 1.2 1.6 CURRENT (AMPS)
Q=0 T=0 2.0
Q=0 T=0
2.0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Addresses
Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) II-VI Japan Inc. WBG Marive East 17F 2-6 Nakase, Mihama-ku Chiba-Shi, Chiba 261-7117 Japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) center@ii-vi.co.jp www.ii-vi.co.jp Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK +44 (0)1444-443404 (tel) +44 (0)1444-443334(fax) Marlow Industries China, II-VI II-VI Singapore Pte., Ltd. Blk. 5012, Techplace II Technologies Beijing A subsidiary of II-VI Incorporated #04-07 & 05-07/12, Ang Mo Kio Ave. 5 Rm 202, 1# Lize 2nd Middle Road Singapore 569876 Wangjing, Chaoyang District (65) 6481 8215 (tel) Beijing 100102 China (65) 6481 8702 (fax) 64391260 ext 105 (tel) info@ii-vi.com.sg 64399315 (fax) www.ii-vi.com.sg info@iivibj.com Doc # 102-0297 Rev B
Page 2 of 2