Features The thermopile sensor consists of a series of 44 thermoelements, forming a sensitive area of 0.5*0.5 mm2. The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 µm wavelength. The thermosensor exhibits an almost white noise, comparable to an ohmic resistance. It has a constant signal versus frequency up to its frequency limit, and is directly proportional to incident radiation.
▓
Applications * Ear thermometers; clinic thermometers * Infrared thermometers * Consumer applications: hair dryer, micro-wave oven, air conditioner, refrigerator * Continuous temperature control of manufacturing * Security system * Radiation monitor switch system * Absorbing measurement for gas analysis * Thermoelectric converter * Heat flux flowmeter
▓
Electrical Characteristics
Parameter
Thermopile Number of thermojunctions Chip size Active area
Condition
Min.
Typ.
Max.
Unit
----Interference layer Siliconsubstrate 25 °C With 5-14µm filter ---
44 1920*1725 500*500
------µm2 µm2
Thickness of substrate Resistance of thermopile Sensitivity Detecctivity Time constant Noise voltage NEP Temperature range
600 60 40 4*107 -------
625 70 55 7*107 30 34 0.8 ---
650 80 70 9*107 ------100
µm KOhm V/W cm*Hz1/2/W Ms nV/Hz1/2 nW/Hz1/2 °C
Operation
-20
Measured at 1 Hz chopper frequency, within spectral range 5-14 µm, using a blackbody radiator of 500K temperature.
▓
Thermopile voltage vs. blackbody temperature
▓
Frequency response
▓
Field of view
▓
Pin assignment & description 1 3 thermopile output pin (+) thermopile output pin (-) Thermopile
2(R)
3(V-)
1(V+) 4(GND)
BACKSIDE VIEW
SIDE VIEW
▓
Order information : OTC-236-AB A : 1 2 : : standard filter (5-14 µm) silicon filter with flat band transmission
B
:
1 2
: :
window size = 2.57mm (diameter) window size = 3.80mm (diameter)
▓
Transmission of filter Transmission of optical filter is measured by FTIR from 2 µm
▓
Package The sensor is hermetically sealed into a TO-5 metal housing, with an optical filter. This standard filter allows measurements to be made in the spectral range above 5 µm wavelength. The dimensions of header and cap are shown below.
OTC-236-11 Unit: mm
ψ8.15 ψ5.4 ψ2.57
2.00 4.6 0.43 Window Window
IR IR Filter filter
Chip Cap Header
OTC-236-12 Unit: mm 8.17 2.00 ψ3.8 WIindow Windo filter IR 0.43 4.6
Chip Cap
Header
▓
Application circuit
Circuit 1 :
+5V
C1
R1 Thermopile 1 3 C3 R5 C4 C5 + OP R6 Vout C6
R4 + R2 2 4 Reference Resistor R3
C2
Circuit 2 :
Pre-Amplification Circuit Ambient Temperature Compensation Circuit
+5V
R10 + A2 Thermopile (+) R7 Adder C1 C3 R13 R11 2 4 + A3 R8 C2 R9 reference resistor Vout
C4
+5V
R1 + A1 R2
1+ 3Thermopile (-)
R12
很抱歉,暂时无法提供与“OTC-236”相匹配的价格&库存,您可以联系我们找货
免费人工找货