Product:Thermoelectric module Part Number:PE1-12704AC
1. Scope 1—1 1—2 This specification is applied to Multicomp thermoelectric modules Revision of these specifications is carried out after consent.
2. Specification 2-1 Parameters Parameters Internal resistance Imax. Vmax. Th=27℃ Qmax. ⊿Tmax. solder melting point Maximum. compress. 35.2 W 70 ℃ 235 ℃ 1MPa 3.5 Ω ± 10% 3.9 A 15.7 V Th=50℃ 39 W 77 ℃ Note-4 Note-5 Note-6 Note-7 Remarks Note-1 Note-2 Note-3
Note-1 Measured by AC 4-terminal method at 25℃. Note-2 Maximum current at ⊿Tmax. Note-3 Maximum voltage at ⊿Tmax. Note-4 Maximum cooling capacity at Imax.,Vmax. and ⊿T=0℃. Note-5 Maximum temperature difference at Imax.,Vmax. and Q=0W. (Maximum parameters are measured in a vacuum 1.3P) Note-6 The solder melting point of thermoelectric module Note-7 Recommended maximum compression (not destruction limit)
2-2 Recommendations: - Operating range: -40 ℃ to +100 ℃ - Dropping or exerting mechanical shock will cause breakage, take care in handling - Thinly spread thermally conductive grease should be placed between module and heat exchanger - Surface deviation from flatness should be kept under 0.02mm - For optimum reliability and performance it is recommended that the module be utilised