Bimetal Cutouts Temperature Regulators Temperature Limiters
ADVANTAGES – high pressure resistance – high response sensitivity – numerous applications – various housings, connections and mounting styles R 20 R 22 R 30 R 32 R 40
DESCRIPTION Types R 20/R 22/R 40 are bimetal detectors and temperature regulators. Types R 30/R 32 are temperature limiters (manual reset) without tripfree mechanism. The thermal response works via a bimetal snap element electrically connected to the switch contact. The switch system is current insensitive. The thermal switches react only to external thermal effects. Double contacts ensure high switch performance and long service life. The housing, base, and the mounting brackets are voltage-free (Standard version: base and mounting brackets are aluminium-plated steel). Heat transfer occurs directly through the metallic base via convection, radiation and conduction in gaseous and solid media. DIMENSIONS R 20 / R 22 / R 40 R 30 / R 32
mounting flange rotating 360 degress
mounting flange rotating 360 degress
Standard version
Standard version
Types: R20/22/30/32/40 03-03-00 1000-Y135
CANTHERM
8415 Mountain Sights Avenue • Montreal (Quebec), H4P 2B8, Canada Tel: (514) 739-3274 • 1-800-561-7207 • Fax: (514) 739-290 E-mail : sales@cantherm.com • Website: www.cantherm.com
TECHNICAL DATA
Type R 20 and R 22 R 30 and R 32 R 40
Voltage rating Current rating at cos j = 1.0 Current rating at cos j = 0.6 Max. load at cos j = 1,0 250 V 50–60 Hz 110 V 50–60 Hz 60 V DC 42 V DC 6, 12, 24 V DC Contacts Normally closed Normally open
* 250 V 50–60 Hz * 10.0 A / * 16.0 A 6.3 A
250 V 50–60 Hz 16.0 A 6.3 A
* 250 V 50–60 Hz * 10.0 A * 6.3 A
16.0 A / 20.0 A 6.0 A 7.2 A 8.5 A
20.0 A
16.0 A 6.0 A 7.2 A 8.5 A
Switch operations at IN
* 10 000 0–170 °C / 16 A – * 100 000 50–160 °C / 10 A < 50 m½ 0 °C to + 170 °C ±3 % ± 6% ±10% ± 3 K ±5 K ± 10 K * 175 °C R 20: 3000 Veff 50–60 Hz R 22: 4000 Veff 50–60 Hz 1500 Veff 50/60 Hz Duroplast on request R 20 9.5 +0.2 R 22 11.5 +0.2
* 200
* 30 000
Contact resistance Nominal temperature range Tolerance but at least Max.permanent temperature Dielectric strength Housing to earth Dielectric strength across open contacts Housing material Housing insulation Overall height (mm)
< 50 m½ +30 °C to + 160 °C ± 3 % ± 6% ±10% ± 3 K ±5 K ± 10 K * 175 °C R 30: 3000 Veff 50–60 Hz R 32: 4000 Veff 50–60 Hz 1500 Veff 50/60 Hz Duroplast on request R 30 9.5+0.2 R 32 11.5 +0.2
< 50 m½ + 50 °C to + 160 °C ± 3 % ± 6% ±10% ± 3 K ±5 K ± 10 K * 175 °C 3000 Veff 50–60 Hz 1500 Veff 50/60 Hz Duroplast on request R 40 12.0+0.2
Note: * Approved nominal values. Other specific values on request.
AREAS OF APPLICATION Temperature regulation, temperature monitoring, temperature limiting and indication in electric appliances and industrial equipment, machinery and process engineering. Examples: Vacuum cleaners Ironing machines Cooking equipment Dampers Heat radiators Hot water heaters Coffee machines Egg boilers Electric appliances
RESET TEMPERATURES Reset temperature will be between 5 °C and 50 °C below the standard response temperatures.
Electrical household appliances Electronic circuits Machinery Process engineering Industrial electric elements Electrical components
RESPONSE TEMPERATURE, TOLERANCE, CODE-NO. Nominal temperatures between 50 and 160 °C in 5 °C steps. Nominal temperatures in geometrical series as per DIN 323 in °C. For tolerance, see above – Technical Data. Temperature code – 3 digits Minimum rate of temperature change 0.1 K/min., max. 1.0 K/min. 2
INSTALLATION/MOUNTING INFORMATION Incorporation of the thermo-switch directly in the heat source or attachment to it, is possible without additional insulation. Slightest changes in temperature are conducted through the metallic housing cap directly to the bimetal snap disc of the thermo-switch. This ensures that time delays of thermal control systems are kept very small: insensitive to installation position. The dust-proof and damp-proof construction of the thermo-switch allows various methods of attachment to, and incorporation in appliances. To ensure the best heat transition, the cap respectively the mounting bracket should be soldered, rivetted, screwed or spot-welded to the heat source.
Types: R20/22/30/32/40 03-03-00 1000-Y135
OPTIONAL VARIATIONS Terminals, Fixings, Housings
Type R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 20/R 22 R 40 R 40 Descrip- Description old tion new A 008 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 125 A128 A129 A 134 A 135 A 137 A 138 A139 AA008 AB 117 AC118 AD119 AE120 AF121 AG122 AH123 AI125 AK128 AL129 AM134 AN 135 AP137 AR138 AS139 Variations Terminals Flat terminal for screw connection 6.3 x 0.8 mm terminal 4.8 x 0.8 mm terminal 6.3 x 0.8 mm terminal, angle 90° 4.8 x 0.8 mm terminal, angle 90° solder connection solder connection, angle 90° flat conductors connector pins 4.8 x 0.5 mm screw connection crimp connection A119 with inside angled connection 6.3 x 0.8 mm A120 with inside angled connection 4.8 x 0.8 mm crimp connection/ screw connection crimp connection/flat terminal screw connection/flat terminal Variations Fixings no mounting bracket 3 hole mounting flange mounting bracket, narrow mounting bracket-standard hole dia. 3.2 mm brass central mounting M 5 x 6 mm brass central mounting M 4 x 8 mm fixed mounting flange, steel, hole distance 23 mm, angle 0° fixed mounting flange, steel, hole distance 23 mm, angle 45° fixed mounting flange, steel, hole distance 23 mm, angle 90° ** * * ** * ** R 20/R 22 ** R 20/R 22 ** ** R 20/R 22 R 30/R 32 R 30/R 32 R 40 R 40 G 146 G 147 G 408 G 409 GG146 GH147 GI408 GK409 R 20/R 22 R 30/R 32 R 40 R 32 R 40 G 129 G 130 G 135 G 145 GC129 GD130 GE135 GF145 R 20/R 22 R 30 R 20/R 22 R 30/R 32 R 40 Type R 40 B 255 BV255 Descrip- Description old tion new G 108 G128 GA108 GB128 ** ** ** ** ** * ** R 20/R 22 R 30/R 32 R 40 * ** ** ** R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 B 235 B 236 B 237 B 238 B 250 BP235 BR236 BS237 BT238 BK250 R 20/R 22 R 30/R 32 R 40 B 228 BN228 B 227 BM227 R 20/R 22 R 30/R 32 R 40 B 226 BL226 Type R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 Descrip- Description old tion new B 223 B 225 BI223 BF225 Variations Fixings fixed mounting flange, steel, hole distance 23 mm, angle 135° fixed mounting flange, steel, hole distance 40 mm, narrow, angle 0° fixed mounting flange, steel, hole distance 40 mm, narrow, angle 45° fixed mounting flange, steel, hole distance 40 mm, narrow, angle 90° fixed mounting flange, steel, hole distance 40 mm, narrow, angle 135° raised flange, hole distance 23 mm, angle 0° raised flange, hole distance 23 mm, anglel 45° raised flange, hole distance 23 mm, angle 90° raised flange, hole distance 23 mm, angle 135° with rotating mounting flange (Standard) hole dia. 3.8 mm mounting element Variations Housings hexagon threaded sleeve, brass, with flat terminals 6.3 x 0.8 mm without rubber cap, with reset pin without rubber cap, with reset pin plastic cover horizontal, for leads and cable housing without reset pin hexagon threaded sleeve, brass, with sensor and leads 300 mm hard paper sleeve voltage-free housing with flange, for leads cap silicone R 300019 without reset cap * * * * **
**
**
R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 20/R 22 R 20/R 22 R 40 R 40 R 40
*
** ** ** ** **
R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 20/R 22 R 40 R 40
R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 Type R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40 R 20/R 22 R 30/R 32 R 40
*
Descrip- Description old tion new B000 B 120 B 214 B 215 B 217 B 218 B 220 B 221 B 222 BX000 BA120 BB214 BC215 BD217 BE218 BU220 BG221 BH222
** ** ** ** ** ** **
Marking (example)
Manufactur = MIC Version = BD16 Type R22 Terminals A Version = ABXX Temperature = C029 Housing X Standard X Ref. letter B
MIC ABXX E BD16 CO29
Reference to: page 4/5 · ** see illustrations ** not illustrated
Fixing B
Code letter D
Base 1
1996 6
60 °C ±5 K C029
A
B
X
X Indicator for housing options A-Z G for housing Indicator for terminal options A-Z A for terminals
B
D
1
6 Year of manufacture 0-9 (6 = 1996) Ref. no. for base 1 = nickel plated steel (standard) 2 = stainless steel 3 = aluminium, anodised 4 = aluminium Indicator for fixing option A-Z B for fixing
C
0
2
9 Code-No. for response temp and tolerance
R 20 / R 22 / R 30 / R 32 / R 40
B 120 3 hole mounting flange
R 20 / R 22 / R 30 / R 32 / R 40
B 255 Mounting element
3
Types: R20/22/30/32/40 03-03-00 1000-Y135
Types: R20/22/30/32/40 03-03-00 1000-Y135
4
5
Types: R20/22/30/32/40 03-03-00 1000-Y135
NOMINAL RESPONSE TEMPERATURE, TOLERANCE, CODE-NO.
Series 10 Tol. ± 10 % °C Code No. 000 05 10 15 20 25 007 010 011 012 015 017 Series 20 Tol. ± 6 % °C Code No. Nor mally closed 000 02 05 10 14 15 18 20 22 25 26 28 30 35 40 45 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160 008 131 133 136 139 013 142 016 145 018 147 020 149 152 155 158 162 027 165 029 169 032 172 035 176 037 179 040 183 042 186 045 190 047 193 050 197 000 02 05 08 10 12 14 15 16 18 20 22 25 26 28 30 33 35 37 40 42 45 47 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160 170 009 132 134 135 137 138 140 014 141 143 144 146 019 148 021 150 151 153 154 156 157 159 160 163 164 166 167 170 171 173 174 177 178 180 181 184 185 187 188 191 192 194 195 198 199 000 05 10 15 20 25 257 260 261 262 265 267 Series 40 Tol. ± 3 % °C Code No. Series 10 Tol. ± 10 % °C Code No. Series 20 Tol. ± 6 % °C Code No. Nor mally open 000 02 05 10 14 15 18 20 22 25 26 28 30 35 40 45 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160 258 331 333 336 339 263 342 266 345 268 347 270 349 352 355 358 362 277 365 279 369 282 372 285 376 287 379 290 383 292 386 295 390 297 393 300 397 000 02 05 08 10 12 14 15 16 18 20 22 25 26 28 30 33 35 37 40 42 45 47 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160 259 332 334 335 337 338 340 264 341 343 344 346 269 348 271 350 351 353 354 356 357 359 360 363 364 366 367 370 371 373 374 377 378 380 381 384 385 387 388 391 392 394 395 398 Series 40 Tol. ± 3 % °C Code No.
30 35 40 45 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160
022 023 024 025 161 026 028 030 168 031 033 034 175 036 038 039 182 041 043 044 189 046 048 049 196
30 35 40 45 50 53 56 60 63 67 71 75 80 85 90 95 100 106 112 118 125 132 140 150 160
272 273 274 275 361 276 278 280 368 281 283 284 375 286 288 289 382 291 293 294 389 296 298 299 396
SPECIAL TEMPERATURE SETTINGS Response temperatures and reset temperatures with specific values and alternative tolerance can be supplied. SPECIAL CONNECTIONS Leads or solid wire from 0.25 mm to 1.0 mm . Lengths from 40 mm to 10 000 mm, with or without stripping possible. Lead ends with DIN connectors or shrouds. Freon and oil resistant leads, PTFE-, PVF2, Nomex and Silicone leads available from stock.
2 2
QUALITY STANDARD Production item testing Voltage test, switch function, Nominal response temperature APPROVALS Life expectancy, voltage rating and current rating comply with VDE 0631 or EN 60730, see page 2. Further approvals obtained for many countries. Information on request.
SPECIAL HOUSINGS When selecting the switch-off temperatures of thermostats in special housings or with non-standard mounting, the time delay due to the thermal mass of the housing/mounting has to be considered. Closer tolerances of nominal switch-off temperatures and reset temperatures, as well as small differentials, are also available for small quantities on request.
ORDERING INFORMATION
Quantity 6000 Type R 22 Code C 183 Temperature °C 100 Version A 119 Tolerance ±6%
Technical data and other specifications may be altered without prior notice.
CANTHERM
8415 Mountain Sights Avenue • Montreal (Quebec), H4P 2B8, Canada Tel: (514) 739-3274 • 1-800-561-7207 • Fax: (514) 739-290 E-mail : sales@cantherm.com • Website: www.cantherm.com
Types: R20/22/30/32/40 03-03-00 1000-Y135