S1430UAP912

S1430UAP912

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    S1430UAP912 - Photoelectrics Amplifier, μ-Processor Controlled Type S1430 UAP, 3 Inputs/3 Transistor...

  • 详情介绍
  • 数据手册
  • 价格&库存
S1430UAP912 数据手册
Photoelectrics Amplifier, µ-Processor Controlled Type S1430 UAP, 3 Inputs/3 Transistor Outputs • µ-Processor controlled • Amplifier unit for 3 sets of photoelectrics • 3 independent outputs • NPN/PNP both NO or NC selectable • Self-diagnostic functions • Alignment failure indication • Multivoltage 12 to 30 VAC/DC • Modulated and synchronized light • Adjustable sensitivity for each channel • LED indications: supply, outputs, signal quality • 11-pin plug-in housing • For 115 or 230 VAC use power supplys from SS120-series Product Description µ-Processor controlled amplifier for 3 sets of photoelectric sensors, type MOFTR, MKFTR, MIFTR or MHFTR. Utilising an 11-pin circular plug for easy connection, outputs freely selectable for NPN/PNP or NO/NC. Selfdiagnostics for system test. Protected against short-circuits, reverse wiring or cross talk from adjacent photoelectrics. Multi-voltage power supply. Sensitivity is individually adjustable for each set of photoelectrics. Ordering Key Type Special function Output type Power supply S14 30 UAP 912 Type Selection Plug type Circular, 11 pins Ordering no. Supply: 12 - 30 VAC/DC S 1430 UAP 912 Specifications Rated operational voltage (UB) pins 2 & 10 DC AC Rated operational power AC supply DC supply Power ON delay (tv) Output function 10.8 to 33 VDC 10.8 to 33 VAC, 45 to 65 Hz 4 VA 3W < 300 ms NPN and PNP switching Make and break function DIP-Switch selectable 100 mA per output 100 mA max. 0.5 mA Max. 100 µA ≤ 3.5 VDC Reverse polarity, short-circuit, transients Tx1: Pin 1 Tx2: Pin 9 Tx3: Pin 6 Shield: Pin 11 (common) 7 V square wave ≤ 300 mA short-circuit protected 10 Ω Supply to photoelectric switch (cont.) Receiver Rx1: Pin 4 Rx2: Pin 7 Rx3: Pin 8 Shield: Pin 5 (common) Supply voltage (open loop) 5 VDC Short-circuit current 10 mA Input resistance 470 Ω Sensitivity • 2 ranges, DIP-Switch selectable (% of Sn) - low sensitivity (25%) - high sensitivity (100%) • Sensitivity adjustment with 270°: Turn knob on CH 1, 2, 3 Note: • Maximum range indicated on photoelectric switch data sheet in high sensitivity range only • Operation within low sensitivity range, increases ambient light and crosstalk immunity Operating frequency (f) Light/dark ratio 1:1 16 Hz Output current Continuous (Ie) Short-time (I) Min. load current (Im) OFF-state current (Ir) Voltage drop (Ud) Protection, outputs Supply to photoelectric switch Emitter Supply voltage (open loop) Current Output resistance Specifications are subject to change without notice (25.06.99) 1 S 1430 UAP Specifications (cont.) Response time OFF-ON (tON) ON-OFF (tOFF) Indication Supply ON Output ON Signal quality Environment Overvoltage category Degree of protection Pollution degree Temperature Operating Storage Weight Approvals CE-marking 20 ms 20 ms LED, green LED, yellow LED, red III (IEC 60664) IP 20 (IEC 60529, 60947-1) 3 (IEC 60664/60664A, 60947-1) -20° to +50°C (-4° to +122°F) -50° to +85°C (-58° to 185°F) 150 g CSA Yes Truth Table Make switching Object present Dirt on lenses, misaligned or sensitivity too low Yes -No No ON No Yes1) ON ON or flashing Break switching Yes -OFF OFF ON No No ON OFF OFF No Yes1) ON ON or flashing Output LED yellow OFF Level LED red OFF OFF ON Output NPN/PNP OFF 1) ON OFF Under normal operating conditions, the red level indication LED has to be OFF. The level indication LED will turn on shortly each time an object enters or exits the sensing zone, even if the photoelectric switch is correctly installed and adjusted. Procedure for Test Functions (Dip-Switch Selection) Transmitter test (switch 5 in the up position) When switch 5 is placed in the up position all yellow and red LED’s on the front of the unit will flash simultaneously. Once the test is completed (approx. 3 scans) and a wiring fault is detected, such as reverse polarity or shortcircuit, the transmitter that has the fault condition will be indicated by the red LED being continuously ON. If a fault condition is not existing then only the yellow LED will be ON. If a fault exists, correct the fault condition and then repeat the test, this will ensure proper wiring has been done. Always reset switch 5 for normal operation of system when testing completed. Receiver test (switch 6 in the up position) When switch 6 is placed in the up position all yellow and red LED’s on the front of the unit will flash simultaneously. Once the test is completed (approx. 3 scans) and a wiring fault is detected, such as reverse polarity or shortcircuit, the receiver that has the fault condition will be indicated by the red LED being continuously ON. If a fault condition is not existing then only the yellow LED will be ON. If a fault exists, correct the fault condition and then repeat the test, this will ensure proper wiring has been done. Always reset switch 6 for normal operation of system when testing completed. Function test (switch 5 and 6 in the up position) When switch 5 and 6 are both placed in the up position (simultaneously) the yellow and red LED’s on the front of the housing will begin to flash simultaneously and then the LED’s LED Indication Yellow LED ON ! Red LED OFF ! will cycle from channel 1 to channel 2 and then to channel 3. Once the complete system scan is done the indication of the system condition will be displayed (see below). System test will continue until switch 5 and 6 are reset. } } } System Test OK Tx’s and Rx’s mismatched, e.g. Rx3 seeing Tx1 Alignment error or beam obstructed by object Yellow LED ON Red LED ON Yellow LED OFF Red LED ON ! Operation Diagram Signal strength Time Power supply Object present Signal quality Break switching Make switching ! 2 Specifications are subject to change without notice (25.06.99) S 1430 UAP Dimensions 35 DIP-Switch (located behind cover): 1: PNP/NPN CH 1 output SW 1 2 3 4 5 6 2: PNP/NPN CH 2 output 3: PNP/NPN CH 3 output 4: Low sensitivity (25%) / high sensitivity (100%) 5: Test button, transmitters are transmitting, no short, wired correctly 6: Test button, receivers are receiving, no short, wired correctly 5+6 together: System test (transmitter and receiver) sw 1, 2, 3: PNP make/NPN break NPN make/PNP break sw 4: Range 25% Range 100%, normal operation sw 6: Receiver test Normal operation 80 84 sw 5: Transmitter test Normal operation sw 5+6: System test 4 75 5 Normal operation Wiring Diagrams Rx 1 Rx 2 Rx 1 3 Tx 1 Tx 2 Rx 3 Tx 1 5 4 3 2 1 6 7 8 9 10 11 Power Supply ON sockets 1: Transmitter 1 2: Supply (+ VDC) 3: No connection 4: Receiver 1 5: GND (Receivers) 6: Transmitter 3 7: Receiver 2 8: Receiver 3 9: Transmitter 2 10: Supply (- VDC) 11: GND (Transmitters) Output A: + (10-40 VDC) B: Output 1 (max. 100 mA) C: Output 2 (max. 100 mA) D: Output 3 (max. 100 mA) E: For handheld tester F: - DC Wire colour coding white black red green yellow blue PNP BCD ABCD F NPN F 10-40 VDC + - 10-40 VDC + - Accessories 11 pole circular socket Socket cover for S111 Socket cover for S411 Holding down spring Mounting rack Front panel mounting bezel Connection cable (2 plugs) 2 x 6/6 modular plugs - Power supply for 115/230 VAC - DIN-rail interface S111, S111A, S411, ZPD11 BB1 BB4 HF SM13 FRS2 2.0 m, 6 wires two plugs SS120-series 6IODC Interface Delivery Contents • Output connection cable • Output connection cable • Amplifier • DIN-rail interface • Screw driver • Packaging: 1 m, 6 wires one plug 0.2 m, 6 wires two plugs S 1430 UAP 912 6IODC Cardboard box 6IODC DIN-rail interface (DIN EN 50 035, EN 50 022) output from plug to screw terminals Specifications are subject to change without notice (25.06.99) 3
S1430UAP912
1. 物料型号: - 型号:S1430 UAP 912 - 描述:这是一个由CARLO GAVAZZI生产的微处理器控制的放大器单元,适用于3组光电传感器。

2. 器件简介: - 该放大器单元具备3个独立的输出,可以选择NPN/PNP以及NO/NC配置。具备自诊断功能,可以指示对齐失败,支持多种电压12至30 VAC/DC,调制和同步光,可调节每个通道的灵敏度,并有LED指示电源、输出和信号质量。封装为11引脚插件式外壳。

3. 引脚分配: - 2 & 10脚为额定工作电压(U2)DC输入。 - 4脚为光电开关(Receiver)供电。 - 5脚为屏蔽(common)5VDC供电。 - 11脚为GND(Transmitters)。

4. 参数特性: - 操作电压:10.8至33VDC或10.8至33VAC,45至65Hz。 - 功率消耗:3W。 - 输出功能:NPN和PNP切换,常开和常关功能,DIP开关可选。 - 输出电流:每个输出连续100mA,短时100mA最大,最小负载电流0.5mA,关闭状态电流最大100μA,电压降≤3.5VDC。 - 输出保护:反极性、短路、瞬变保护。

5. 功能详解: - 具备自诊断功能,可以进行系统测试。 - 输出类型:NPN/PNP或NO/NC可选。 - 电源:多电压电源。 - 灵敏度:每个光电传感器的灵敏度可以单独调节。

6. 应用信息: - 适用于115或230VAC的电源,使用SS120系列电源。

7. 封装信息: - 封装为11引脚插件式外壳,适用于多种电源和输出配置。