0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SFS5

SFS5

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    SFS5 - AC-DC Converter Compact Miniature Type - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
SFS5 数据手册
DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type PCB mount type Chassis mount type Features • UL, CB, CE Approved • RoHS directive compliance • Encapsulated, compact case • High efficiency • Universal input • Surface mounting technology • 100 kHz fixed frequency • Fixed output voltage • Thermal shutdown(IC-Temp: 150 °C) • Low output ripple & noise • Isolated input-output(3kVAC) • Over voltage protection(O.V.P.) • Over current protection(O.C.P.) • Output short circuit protection • Low no-load power consumption(0.3W Max.) • 5Years warranty Environmental • Operating temperature range: -10℃~70℃ • Storage temperature range: -20℃~80℃ • Humidity: 20%~90%RH • Vibration: 10-55Hz at 10G(98m/s²), 3minutes period, 60minutes each one X, Y and Z axis • Impact: 50G(490m/s²), 11ms, once each • Cooling method: natural air convection Safety (single output) •UL (UL60950-1, CSA C 22.2 NO. 60950-1) •UL No: E227474 •CE (EN 60950-1) / CB (IEC 60950-1) Option •Chassis mount type: Euro style terminal-block Description The SFS5 Series has universal AC input and there are 5 models with single output and 2 models with dual outputs which are all available in two different pin assignments – PCB mount or Chassis mount. Super compact size with elegant design and high reliability are achieved. CEC compliant design shows high efficiency and low no-load power consumption. A limited EMI filter is included and an additional EMI filter to input side is required to meet CISPR22-B EMI Standard. With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Electrical specifications INPUT Voltage Current Frequency Efficiency Inrush current (at cold start) Leakage current AC85~264V (or DC 110~340V) 50/60Hz (note) 0.15A Max. @ 110VAC / 0.08A Max. @ 220VAC 47~440Hz Max. (50~60Hz typ.) 75% Typ. 20A Max. @ 120VAC. / 40A Max. @ 240VAC 0.5mA Max. @ 110VAC / 0.75mA Max. @ 220VAC OUTPUT Voltage tolerance (accuracy) Ripple and noise Line regulation Load regulation Dynamic load regulation Temperature regulation No-load power consumption Rising time Hold up time ±2% Max (single and uncomplementary dual). ±3% Max (complementary dual). ±1% Typ. ±1% Typ. ±1% Typ.@output1 , ±2% Typ.@output2 ±3% Typ.@output1 ±1% Typ. 0.3W Max. 100ms Max. 10ms Min. Protection circuit Over voltage protection Over current protection Over temperature protection Clamp, 130~150% Works at over 105% of rating & recovers automatically 150℃ Latching, Recovering Isolation specifications Isolation Resistance Input-Output Isolation Voltage DC 500V, 100MOhms Min. AC 3KV, 1minute, 10mA. General specifications Switching frequency Calculated MTBF Weight 100kHz 4.5*105 hrs 40g or less NOTE: For cases that conform various safety specifications(UL, CSA, CE, CB etc). It require input voltage and frequency range will be 100-240Vac, 50~60Hz. With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Ordering information SF□5-12□ Series name S: single D: dual Input Output1 3.3V@1.25A 5V@1.0A AC85~264V or DC110~340V 12V@0.42A 15V@0.33A 24V@0.21A +12V@0.21A +15V@0.17A -12V@0.21A -15V@0.17A Output2 Maximum power 4.125W 5.0W 5.0W 5.0W 5.0W 5.0W 5.0W If chassis mount type, 'C' added Output voltage Output power Ripple & Noise 80mVp-p 80mVp-p 120mVp-p 150mVp-p 200mVp-p 120/120mVp-p 150/150mVp-p Efficiency typical 68% 75% 77% 77% 77% 72% 72% Model number SFS5-3R3 SFS5-5 SFS5-12 SFS5-15 SFS5-24 SFD5-1212 SFD5-1515 Pin assignments Single output 1. AC(N) 2. AC(L) 3. No pin 4. -V 5. +V Dual output 1. AC(N) 2. AC(L) 3. -V 4. GND 5. +V Derating curve Dimensions Chassis Mount Type NOTES 1. 2. 3. 4. All dimensions are inch(mm). Weight : 40g or less Case material : PBT, 94V-0 Rated Construction : encapsulated, Soft Pot 5. Dimension "H" 0.6(15.24) for 5watt / SFS5,SFD5 version With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Inrush Current - 240Vac input TEST CONDITION - Full load output - PHASE 90°input start, current measure SFS5-3R3 12.2A SFS5-5 11.9A SFS5-12 12.1A SFS5-15 11.9A Inrush current concerns wrong to fuse, input rectifier, powerswitch, circuit break and parts. It degrades the another circuit voltage and occurs system error. If you defuse inrush current. You add NTC or Inrush current limiter to external circuit. High rating voltage input Max20A @ 120Vac Max40A @ 240Vac SFS5-24 12.85A With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Rising Time - 220Vac Input TEST CONDITION - Full Load Output - Output Voltage 10% ~ 90% Rising Time Measure SFS5-3R3 5.66mS SFS5-5 7.98mS SFS5-12 13.0mS SFS5-15 15.6mS Max 100ms between output voltage 0%~90% SFS5-24 19.7mS With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Hold up Time - 220Vac Input TEST CONDITION - Full Load Output -When Input off Phase 360°, Output Voltage off Time Measure SFS5-3R3 80mS SFS5-5 75mS SFS5-12 75mS SFS5-15 78mS The amount of time that a power supply's outputvoltage remains within the specified-voltage ranges after it's input voltage interrupts. Low rating voltage Min10ms @100Vac SFS5-24 69mS With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Start up Time - 220Vac Input TEST CONDITION - Full Load Output -When Input on Phase 360°, Output Voltage 100% rise Time Measure SFS5-3R3 23.8mS SFS5-5 84.6mS SFS5-12 72.3mS SFS5-15 55.5mS Amount of delay time and rise time. After inputvoltage injects. SFS5-24 32.9mS With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Dynamic Load - 220Vac Input TEST CONDITION - 0% Load ~ 100% Load Output - Freq. : 100Hz , - Duty : 0.5 SFS5-3R3 92.5mV SFS5-5 53mV SFS5-12 69mV SFS5-15 85mV Considerate slew rate and frequency within ±3% output voltage value. SFS5-24 135mV With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Over Shoot - 220Vac Input TEST CONDITION - Full Load Output SFS5-3R3 0V SFS5-5 0V SFS5-12 0V SFS5-15 0V When turn-on, the output overshoot voltage shall not exceed 5% of normal Voltage value no Load or full Load connected. SFS5-24 0V With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Output Ripple & Noise - 220Vac Input TEST CONDITION - Full Load Output - Ele-cap(47uF)and Ceramic-cap(104), Output Terminal SFS5-3R3 51.6mVpp SFS5-5 41.2mVpp SFS5-12 46.2mVpp SFS5-15 40.2mVpp *Ripple & Noise: Oscilloscope bandwidth 20MHz. The length of the output line should be shorter than 1meter and it needs to be twisted. SFS5-24 74.6mVpp With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Efficiency Curve(Load Variation) Load(%) Eff(%) 10 50.8% 20 60.6% 50 68.2% 80 68.6% 100 70.0% Load(%) Eff(%) 10 59.5% 20 65.0% 50 74.6% 80 76.5% 100 76.8% SFS5 - 3R3 SFS5 - 5 Load(%) Eff(%) 10 51.4% 20 66.9% 50 77.7% 80 77.8% 100 80.2% Load(%) Eff(%) 10 50.0% 20 68.1% 50 76.5% 80 78.7% 100 79.5% SFS5 - 12 SFS5 - 15 Input 220Vac, Variation of efficiency, from minimum load to maximum load. Load(%) Eff(%) 10 52.1% 20 69.0% 50 77.5% 80 80.5% 100 81.6% SFS5 - 24 With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Efficiency Curve(Input Voltage Variation) Input (V) Eff(%) 85 V 66.5% 110 V 68.8% 220 V 69.7% 264 V 68.3% Input (V) Eff(%) 85 V 73.8% 110 V 76.4% SFS5 - 5 220 V 76.6% 264 V 75.1% SFS5 - 3R3 Input (V) Eff(%) 85 V 77.9% 110 V 80.1% 220 V 80.3% 264 V 78.5% Input (V) Eff(%) 85 V 79.0% 110 V 80.7% 220 V 79.5% 264 V 77.8% SFS5 - 12 SFS5 - 15 Variation of Efficiency, from Minimum input Voltage to Maximum input Voltage Input (V) Eff(%) 85 V 79.5% 110 V 81.2% 220 V 81.0% 264 V 78.5% SFS5 - 24 With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type No-Load Power Consumption No load power consumption is the power used by a device. when it is disconnected from it's load and performing no function. SFS5 series are very low no-load power consumption (single output). With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Thermal Test After power supply SFS5 Series was molded, and Components Thermal measurement. Operating the power supply At normal temperature. Until the temperature of components is saturated. Maximum permitted degree of components ascertains the margins. We will calculate the maximum operation degree. Degree of ambient temperature rises up and load derates. Test Voltage(V), 60Hz Tamb Temperature T of part 1. 5Vdc F1 Body 2. L1 Body 3. C1 Body 4. D1 5. Transformer coil 6. Transformer core 7. Inside Enclosure 8. Outside Enclosure 9. 3.3Vdc Transformer coil 10. Transformer core 11. 12Vdc Transformer coil 12. Transformer core 13. 15Vdc Transformer coil 14. Transformer core 15. 24Vdc Transformer coil 16. Transformer core 17. Ambient 90VAC 24.6 42.8 38.7 40.3 45.4 47.2 46.5 44.8 42.0 47.0 47.1 47.4 46.6 46.7 46.2 44.3 42.2 24.6 Δ℃ 254VAC 24.9 43.5 37.6 40.5 45.4 50.7 50.0 47.6 44.0 50.0 50.3 48.6 47.2 51.7 51.0 48.4 45.4 24.9 Δ℃ REMARK 18.2 14.1 15.7 20.8 22.6 21.9 20.2 17.4 22.4 22.5 22.8 22.0 22.1 21.6 19.7 17.6 0.0 18.6 12.7 15.6 20.5 25.8 25.1 22.7 19.1 25.1 25.4 23.7 22.3 26.8 26.1 23.5 20.5 0.0 With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Electro Magnetic Interference Application. SFS5 Series are needed to reduce Electromagnetic Interference, use the external L-C noise filter at the input of the Converter. 1. Configuration N VOUT C2 222Y2 C1 224X2 SMPS L GND INPUT L1 L/F C3 222Y2 F.G. C4 222Y1 OUTPUT 2. Components L1 = 10~30mH Common Mode Line Filter C1 = 220nF X2 Capacitor C2,C3 = 2200pF Y2 Capacitor C4 = 2200pF Y1 Capacitor The CISPR 22 Standard @ SFS5-12 With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type DRIFT No Time 3.3V 1.25A 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 08:30 09:00 09:30 10:00 10:30 11:00 11:30 12:00 12:30 13:00 13:30 14:00 14:30 15:00 15:30 16:00 16:30 17:00 3.314 3.310 3.307 3.304 3.304 3.306 3.307 3.306 3.303 3.306 3.306 3.304 3.305 3.306 3.306 3.305 3.304 3.306 5V 1.0 A 5.024 5.022 5.020 5.019 5.020 5.020 5.019 5.020 5.020 5.020 5.020 5.020 5.020 5.020 5.019 5.019 5.020 5.020 Voltage(V) 12V 0.42 A 12.100 12.077 12.068 12.067 12.068 12.070 12.066 12.068 12.068 12.067 12.067 12.062 12.069 12.070 12.064 12.068 12.062 12.063 15V 0.33 A 14.999 14.996 14.999 15.000 14.999 14.999 15.000 14.999 14.999 14.998 14.999 14.998 14.998 14.997 14.998 14.999 14.998 14.998 24V 0.21A 24.010 23.980 23.980 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 23.990 Remarks Vin 220VAC 1. Primary Drift:(Maximum Value - Datum Value)÷Datum V × 10^6(Power On~30minute) 3.3V 5V 12 V 15 V 24V 1208.45921 398.24771 1904.44647 200.053348 1251.04254 PPM PPM PPM PPM PPM 2. Passage Drift: (Max Value - Datum Value) ÷ Datum V × 10^6 (30Minutes ~ Until 8hours 30minutes) 3.3V 5V 12 V 15 V 24V 3.3V 5V 12 V 15 V 24V -2114.8036 -398.24771 -1242.0303 266.737797 417.014178 0.007 0.003 0.015 0.004 0.01 PPM PPM PPM PPM PPM V : 0.2% V : 0.06% V : 0.125% V : 0.03% V : 0.04% (Maximum Value - Minimum Value) With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Calculating Reliable Values of MTBF 1. Calculating method Calculated based on part count reliability projection of MIL-HDBK-217F Individual failure rates λg is given to each part and MTBF (Mean Time Between Failure) is calculated by the count of each part. : n MTBF = 1/ λepuip = 1/ (∑Ni(λG∏Q)i i=1 λequip λG ∏Q Ni n *10^6 (Hours) : Total Equipment Failure Rate (Failure/10^6Hours) : Generic Failure Rate for The ith Generic Part (Failure/ 10^6Hours) : Generic Quality Factor for The ith Generic Part (∏Q=1) : Quantity of ith Generic Part : Number of Different Generic Part Categories 2. MTBF Values MTBF ≒484,937(Hours) PART Number n Logic IC Transistor, FET Diode Voltage Regulator Photo-coupler Diode Bridge Ele-capacitor Ceramic Capacitor MLCC Choke coil Switching trans Line Filter Resistor Chip Connector Reflow soldering Flow soldering PCB Fuse Total Equipment Failure Rate λG×n(F/T) MTBF = 10^ / λG(F/T) 6 Failure Rate λG(F/T) Failure Rate*n λG×n(F/T) 0.01500 0.09900 0.13200 0.02400 0.07000 0.19800 0.05700 0.02600 0.37100 0.00022 0.00420 0.00880 0.11200 0.26000 0.00630 0.28860 0.37000 0.02000 2.06212 484937.831 SMT *3 Remark 1 1 6 1 1 1 3 1 7 1 1 2 7 5 45 37 1 1 0.01500 0.09900 0.02200 0.02400 0.07000 0.06600 0.01900 0.02600 0.05300 0.00022 0.00420 0.00440 0.01600 0.05200 0.00014 0.00780 0.37000 0.02000 Separate Separate With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Reliability Specification Dry heat Cold Thermal shock Temperature, humidity cycle Vibration Mechanical shock Electrostatic Discharge immunity Immunity to radio frequency EM-fields Electrical fast transient/burst immunity Surge immunity B10 Life test Standard IEC60068-2-2 IEC60068-2-1 IEC60068-2-14 IEC60068-2-30, IEC60068-2-38 IEC 60068-2-6 IEC 60068-2-27 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 B10 Life is the time by which 10% of the product population will get failed Remarks With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Instruction manual 1. Basic connection L Output Load N Input AC85~264V 50~60Hz NOTE: To avoid excessive voltage drop and for improved noise, and short and thick wire should be used to connect the load. Length below 50Cm & wire thickness of 4.0A/mm2 are recommended for reducing wire loss when wire connection is necessary. 3. Series Operation Choose a diode in accordance with voltage, power dissipation and heat radiation. - Voltage : V > Vo × 3 - Current : I > Io × 3 - Design a proper heat sink according to power loss at diode ( Pw = Vf × Io ). - Use a schottky or fast recovery diode this has a low VF. GND + + Load + - 2. Parallel Operation This supply can be operated the following ways. Choose a diode in accordance with voltage, power dissipation and heat radiation. - Voltage : V > Vo × 3 - Current : I > Io × 3 - Design a proper heat sink according to power loss at diode ( Pw = VF × Io ) - Use a schottky or fast recovery diode this has a low VF. - + - + Load - + - + Load - + + Load + - 4. Over Current Protection Output current is grown, this is mainly due to the poor coupling between the auxiliary winding and the power winding. Which prevents proper collapsing. When Vout goes low. With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Instruction manual 5. Over Voltage Protection SFS series are equipped with an over-voltage protection circuit by zener diode. If zener diode is opened, Vcc rise up, it becomes possible to implement an over voltage protection. Ratch on mode. If zener diode is short, output is shorted. It becomes possible to implement a short circuit Protection. 10. Withstand Voltage SFS5 series are designed to withstand 3KVAC (10mA) 1 minute between input output for the withstand voltage test, the applied voltage must be increased gradually from zero to the testing value, and then decreased gradually at shut down. Especially stay away from use of a timer. Where a pulse of several times the applied voltage can be generated. 6. Over Temperature Protection Temperature protection is provided by a precision analog circuit that turns the output MOSFET off when the junction temperature exceeds the thermal shutdown temperature (130℃ Min. , 140℃ Typ. and 70℃ hysteresis). When the junction temperature cools to below the hysteretic temperature, normal operation resumes providing automatic recovery. L Output N GND 7. Line Regulation Maximum line regulation is maximum output voltage change when the input volt is slowly varied with in the input voltage range. 11. No-Load Power Consumption No-Load power is the energy used by a device when it is disconnected from it's load and performing no function. 8. Load Regulation Maximum load regulation is maximum output voltage value change when varying the load current slowly within the standard output current range. 12. Short Circuit Protection By permanently monitoring the feedback line activity, the IC is able to detect the presence of a short-circuit. Immediately reducing the output 9. Isolation Resistance The isolation resistance is more than 100MΩ at 500 VDC when tested with DC isolation between the output and the case. Make sure that during testing, the isolation tester does not produce a high pulse when the applied voltage is varied. Ensure that the tester is fully discharged after the test. power for a total system protection. Once the short has disappeared, the controller resumes and goes back to normal operation. With Your Electronics POWERPLAZA www.powerplaza.co.kr DATASHEET SEP 05, 2007 SFS5 Series AC-DC Converter Compact Miniature Type Instruction manual 13. Block Diagrams Circuit topology : Flyback Switching frequency : 100KHz(fixed) NOISE RECTIFIER & FILTER AC 85~264V RECTIFIER & FILTER FILTER OUTPUT SWITCHING IC FET FEED BACK PWM IC Power Plaza co., Ltd #1401, Daeryung Techno Town 493-6 Gasan-Dong, Kumchon-Gu, Seoul, 153-774, Korea Tel: 82_2_855_4955 Fax: 82_2_855_4954 E-mail: sales@powerplaza.co.kr With Your Electronics POWERPLAZA www.powerplaza.co.kr

很抱歉,暂时无法提供与“SFS5”相匹配的价格&库存,您可以联系我们找货

免费人工找货