MODEL TL-5930
International size reference: D, ER32L615
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
Nominal capacity @ 4 mA, to 2 V 19 Ah Rated voltage 3.6 V Maximum recommended continuous current 230 mA Maximum pulse current capability 500 mA Weight 93 g (3.28 oz) Volume 51 cc Operating temperature range -55 ºC to +85 ºC Li metal content approx. 5 g U.L. Component Recognition, MH 12193
Volts
4.0
DISCHARGE CHARACTERISTICS @ +25ºC
3.5
3.0
2.5
2.0
33 Ω ~100 mA (9.0 Ah) 56 Ω ~60 mA (13.1 Ah) 180 Ω 330 Ω 910 Ω ~20 mA ~10 mA ~4 mA (16.9 Ah) (18.2 Ah) (19.0 Ah) 18 kΩ ~200 µA (15.4 Ah)
1.5
TERMINATIONS & ORDERING NO.
SUFFIX- /S STANDARD 15-5930-21500 15-5930-31500 SUFFIX- /T SOLDER TABS
1.0 1 10 100 1000 10000 100000 Hours
Volts
3.7 3.5 3.3 3.1 2.9 2.7 2.5 2.3 -50
50 µA
VOLTAGE VS. TEMPERATURE
Ah
20.0 18.0
0 °C 25 °C
CAPACITY VS. CURRENT
100 µA 0.5 mA 2 mA 20 mA
16.0 14.0 12.0 10.0 8.0
55 °C
72 °C
100 mA
6.0 4.0 2.0 -30 -10 10 30 50 70 90 ºC 0.1 1 10
-30 °C
100
mA
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. B 01/06 Page 1 of 2
TL-5930
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density Low self discharge rate 10 years shelf life Bobbin construction Hermetic glass-to-metal-sealing Non-flammable electrolyte Restricted for transportation (Class 9 worldwide) Non-restricted within the US
Volts
3.4
MAIN APPLICATIONS
Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP) devices Others
VOLTAGE RESPONSE AFTER STORAGE
After 2 years After 1 year After 5 years
3.2
After 8 years
3.0
After 10 years
STORAGE CONDITIONS
Cells should be stored in a clean & dry (less than 30 % RH) area Temp. should not exceed +30 ºC
2.8
Pulse applied: 60 mA for 1 sec Storage: RT Background current: None
2.6
2.4 0 200 400 600 800 1000 1200 msec
For updated information please visit our website w ww.tadiranbat.com
Volts
3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 0 20
VOLTAGE RESPONSE
After 1 year After 2 years After 5 years
Volts
3.6 3.4 3.2 3.0
After 8 years After 10 years
VOLTAGE RESPONSE
After 1 year After 2 years
After 5 years
2.8 2.6 2.4 2.2 Pulse applied: 60 mA for 100 msec Temperature: RT Background current: 100 µA 0 20 40 60 80
After 8 years
Pulse applied: 60 mA for 100 msec Temperature: RT Background current: 50 µA 40 60 80 100 120 msec
100
120 msec
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. B 01/06 Page 2 of 2
很抱歉,暂时无法提供与“TL-5930”相匹配的价格&库存,您可以联系我们找货