VRE125M 数据手册
VRE125/127 Precision High Temperature Reference Supplies RHOPOINT COMPONENTS LTD., Holland Road,Hurst Green, Oxted, Surrey, RH8 0AX. Tel: +44 (0)1883 717988 FEATURES • WIDE OPERATING RANGE: -55°C to +200°C • VERY HIGH ACCURACY: 5.000 V ±0.4 mV • EXTREMELY LOW DRIFT: 0.6 mV (-55°C to +150°C) 2.0 mV (-55°C to +200°C) • EXCELLENT STABILITY: 6 ppm / 1000Hrs. • EXCELLENT LINE REGULATION: 6 ppm / V Typ. • HERMETIC 14-PIN DIP APPLICATIONS • PRECISION A/D and D/A CONVERTERS • ACCURATE COMPARATOR THRESHOLD VOLTAGE • HIGH RESOLUTION SERVO SYSTEMS • HIGH TEMPERATURE TEST and MEASUREMENT SYSTEMS • TRANSDUCER EXCITATION • GEOLOGICAL EQUIPMENT DESCRIPTION VRE125 series references are designed to operate over an extremely wide temperature range (-55°C to +200°C) and still provide excellent accuracy. The VRE125 provides a +5V output and the VRE127 provides a ±5V output. All types are available in commercial (C suffix) and military (M suffix) models. They are hermetically sealed and are screened for high reliability and quality. Two accuracy grades (standard and A) are available in both models. The adjacent selector guide shows the limits of the most important parameters of the VRE125/127 series references. SELECTION GUIDE Max. Volt Deviation (-55°C to +150°C) Max. Volt Deviation (150°C to +200°C) Initial Error (Max) Type VRE125C VRE125CA VRE125M VRE125MA VRE127C VRE127CA VRE127M VRE127MA Output +5V +5V +5V +5V ±5V ±5V ±5V ±5V ±0.9mV ±0.6mV ±0.9mV ±0.6mV ±0.9mV ±0.6mV ±0.9mV ±0.6mV ±3.0mV ±2.0mV ±3.0mV ±2.0mV ±3.0mV ±2.0mV ±3.0mV ±2.0mV ±0.8mV ±0.4mV ±0.8mV ±0.4mV ±0.8mV ±0.4mV ±0.8mV ±0.4mV The accuracy of the VRE125/127 series over temperature is achieved by using Thaler Corporation's patented multi-point compensation technique. The stability of the VRE125 series is enhanced by using a zener diode instead of a bandgap reference, which is typically used in 5V references. Zener diodes have better long term stability and don't suffer the significant shifts caused by temperature cycling that bandgap references do. Other performance parameters, such as warm-up drift and long term stability are better than competitive models. Superior stability, accuracy, and quality make these references ideal for high temperature applications such as A/D and D/A converter references. VRE125DS REV. C SEPT 1994 ELECTRICAL SPECIFICATIONS Vps =±15V, T = 25°C, RL = 10KΩ unless otherwise noted. VRE125/127 CA MIN TYP MAX MIN MODEL PARAMETERS MIN C TYP MAX M MA UNITS TYP MAX MIN TYP MAX ABSOLUTE MAXIMUM RATINGS Power Supply ±13.5 ±22 Operating Temperature -55 200 Storage Temperature -65 150 Short Circuit Protection Continuous OUTPUT VOLTAGE VRE125 VRE127 +5 ±5 * * * * * * V V * * * * * * * * * * * * * * * * * * * * * V °C °C OUTPUT VOLTAGE ERRORS Initial Error Warmup Drift (1) -55°C to 150°C (3) 150°C to 200°C Long-Term Stability Noise (.1-10Hz) OUTPUT CURRENT Range REGULATION Line Load OUTPUT ADJUSTMENT Range Temperature Coefficient POWER SUPPLY CURRENTS VRE125 +PS VRE127 +PS VRE127 -PS NOTES: *Same as C Models. (2) 0.8 2 0.9 3.0 6 3 * * 1 0.4 2 0.6 2.0 * * 0.8 * * * * 0.4 1 * * mV ppm mV mV ppm/1000hr. µVpp ±10 * * * mA 6 3 10 * * * * * * * * * ppm/V ppm/mA 10 4 * * * * * * mV µV/°C/mV 4 6 4 7 9 6 * * * * * * * * * * * * * * * * * * mA mA mA 1.Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range. 2.The specified values are unloaded. 3. Cone widening from 150 °C value to specified value. VRE125DS REV. C SEPT 1994 TYPICAL PERFORMANCE CURVES VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE Temperature oC VRE125/127C Temperature oC VRE125/127CA Temperature oC VRE125/127M Temperature oC VRE125/127MA VRE125 QUIESCENT CURRENT VS. TEMP JUNCTION TEMP. RISE VS. OUTPUT CURRENT PSRR VS. FREQUENCY Temperature oC Output Current (mA) Frequency (Hz) VRE127 POSITIVE OUTPUT QUIESCENT CURRENT VS. TEMP JUNCTION TEMP. RISE VS. OUTPUT CURRENT PSRR VS. FREQUENCY Temperature oC Output Current (mA) NEGATIVE OUTPUT Frequency (Hz) QUIESCENT CURRENT VS. TEMP JUNCTION TEMP. RISE VS. OUTPUT CURRENT PSRR VS. FREQUENCY Temperature oC Output Current (mA) Frequency (Hz) VRE125DS REV. C SEPT.1994 DISCUSSION OF PERFORMANCE THEORY OF OPERATION The following discussion refers to the schematic below. A FET current source is used to bias a 6.3V zener diode. The zener voltage is divided by the resistor network R1 and R2. This voltage is then applied to the noninverting input of the operational amplifier which amplifies the voltage to produce a 5.000V output. The gain is determined by the resistor networks R3 and R4: G=1 + R4/R3. The 6.3V zener diode is used because it is the most stable diode over time and temperature. The current source provides a closely regulated zener current which determines the slope of the reference's voltage vs. tamperature function. By trimming the zener current a lower drift over temperature can be achieved. But since the voltage vs. temperature function is nonlinear, this method leaves a residual error over wide temperature ranges. To remove this residual error, Thaler has developed a nonlinear compensation network of thermistors and resistors that is used in the VRE series references. This proprietary network eliminates most of the nonlinearity in the voltage vs. temperature function. By then adjusting the slope, Thaler Corporation produces a very stable voltage over wide temperature ranges. This network is less than 2% of the overall network resistance so it has a negligible effect on long term stability. APPLICATION INFORMATION Figure 1 shows the proper connection of the VRE125 series voltage reference with the optional trim resistors. When trimming the VRE127, the positive voltage should be trimmed first since the negative voltage tracks the positive side. Pay careful attention to the circuit layout to avoid noise pickup and voltage drops in the lines. When using precision voltage references at high temperatures it is best to keep them powered up. If the zener diode isn't powered up at high temperatures the junction will collect ions, and then when power is applied, the voltage will drift until the charge build up is depleted. The VRE125 series voltage references have the ground terminal brought out on two pins (pin 6 and pin 7) which are connected together internally. This allows the user to achieve greater accuracy when using a socket. Voltage references have a voltage drop across their power supply ground pin due to quiescent current flowing through the contact resistance. If the contact resistance was constant with time and temperature, this voltage drop could be trimmed out. When the reference is plugged into a socket, this source of error can be as high as 20ppm. By connecting pin 7 to the power supply ground and pin 6 to a high impedance ground point in the measurement circuit, the error due to the contact resistance can be eliminated. If the unit is soldered into place the contact resistance is sufficiently small that it doesn't effect performance. VRE125 FIGURE 2 VRE127 FIGURE 3 VRE125DS REV. C SEPT 1994 EXTERNAL CONNECTIONS FIGURE 1 3. Optional Fine Adjust for approximately ±10mV. VRE127 center tap connects to -PS. 4. Pin 6 is internally connected to Pin 7 and can be used as Ref. GND. PIN CONFIGURATION TOP VIEW NC NC NC NC NC REF. GND GND FINE ADJ. +5V FINE ADJ. -ADJ. -5V -ADJ. -PS NC REF. GND GND TOP VIEW +ADJ. +5V +ADJ. VRE125 +PS NC NC NC VRE127 +PS NC NC NC MECHANICAL 14-PIN HYBRID PACKAGE INCHES DIM E L D B B1 B2 S P MIN .480 .195 .775 .016 .038 .095 .085 .004 MAX .500 .215 .805 .020 .042 .105 .105 .006 MILLIMETER MIN 12.1 4.9 19.7 0.4 0.9 2.4 2.1 0.10 MAX 12.7 5.4 20.4 0.5 1.0 2.6 2.6 0.15 DIM A Q Q1 C G1 INCHES MIN .120 .015 N/A .009 .290 MAX .155 .035 .030 .012 .310 MILLIMETER MIN MAX 3.0 0.4 N/A 0.2 7.3 4.0 0.9 0.7 0.3 7.8 VRE125DS REV. C SEPT 1994
VRE125M
物料型号: - VRE125系列和VRE127系列,分别提供+5V和±5V输出。

器件简介: - VRE125系列和VRE127系列是高精度、宽温度范围的参考电源,能够在-55°C至+200°C的温度范围内提供优异的准确性。这些参考电源采用Thaler公司的多点补偿技术,以实现在宽温度范围内的高精度。

引脚分配: - 这两个系列的参考电源都采用14引脚的DIP封装,其中6号和7号引脚内部连接,可以作为参考地(Ref. GND)使用。

参数特性: - 初始误差:VRE125系列为0.8mV至0.4mV,VRE127系列为0.8mV至0.4mV。 - 温度范围-55°C至+150°C的电压偏差:VRE125系列为±0.9mV至±0.6mV,VRE127系列为±0.9mV至±0.6mV。 - 长期稳定性:150°C至200°C的温度范围内,VRE125系列为6ppm/1000小时,VRE127系列为6ppm/1000小时。

功能详解: - VRE125系列使用齐纳二极管代替通常用于5V参考源的带隙参考,齐纳二极管具有更好的长期稳定性,并且不会因为温度循环而产生显著的偏移。 - 通过调整齐纳电流,可以实现更低的温度漂移,并通过Thaler公司的专利非线性补偿网络消除电压与温度函数中的大部分非线性,从而在宽温度范围内实现非常稳定的电压输出。

应用信息: - VRE125系列电压参考适用于高精度应用,如模数转换器和数模转换器的参考,以及高温测试和测量系统。 - 使用时应注意电路布局,避免噪声拾取和线路上的电压降。 - 在高温下使用时,最好保持电压参考通电,以防止齐纳二极管结收集离子导致电压漂移。

封装信息: - 采用14引脚的混合封装,具体尺寸和引脚配置在文档中有详细说明。