WM22-DINAV2BXA1

WM22-DINAV2BXA1

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    WM22-DINAV2BXA1 - Energy Management Power Analyzer with plug-in Output Modules - List of Unclassifed...

  • 数据手册
  • 价格&库存
WM22-DINAV2BXA1 数据手册
Energy Management Power Analyzer with plug-in Output Modules Type WM22-DIN • Class 0.5 (current/voltage) • Three-phase power analyzer • Back-lighted LCD • 4 x 31/2 DGT instantaneous variables read out • 71/2 DGT energy read-out • Measurements of system and phase variables: W, Wdmd, var, VA, VAdmd, PF (cosϕ), V, A, Hz, THD-A, THD-V • Measurements of total energies: kWh, kvarh • Measurements of partial energies: kWh, kvarh • Energy measurements according to EN61036 and EN61268 • TRMS measurements of distorted wave forms (voltages/currents) • Two basic models: direct connection 20(90)AAC, CT 5(10)AAC and VT connection • Maximum value indication of W dmd and VA dmd (only 5A version); maximum value indication of A (only 90A version) • Self power supply (available for some models only) or auxiliary power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC, 77 to 143VDC • Degree of protection (front): IP 40 • Front dimensions: 9 DIN modules • Analogue output by means of optional module (20mA or 10VDC) • RS 422/485 Serial port by means of optional module • Alarm output by means of optional module • Dual pulse output by means of optional module • Control of phase asymmetry Product description Three-phase power analyzer with built-in configuration key-pad; Particularly indicated for the analysis of main, secondary and energy metering electrical variables. Housing for DIN-rail or wallmounting, IP40 (front) protection degree. Completely sealable housing. In case of direct connection up to 90A, the measuring input terminals are suitable for cables with a cross-section area from 6 to 35 mm . The special design of the instrument’s housing allows to add at any time the interface modules, even when the instrument is already installed. The following modules are available: - for all versions: pulses output; - only for the versions with auxiliary power supply: analogue output, RS485 port or alarm output. 2 How to order Model Range code System Power supply Slot A Slot B WM22-DIN AV5 3 X X XX Important note: • The models from AV0 to AV7 can be equipped with any type of available modules (slot A and B). • The models AV8 and AV9 can be equipped only with the “O” and “R” type modules. • The AV8 and AV9 models can measure all the parameters even if the three phase system being connected is missing one phase. • The Av2 model is suitable only for three-phase unbalanced system without neutral. Type selection Range Code Auxiliary Power Supply: AV0: 208VL-L/20(90)AAC [3] AV1: 400VL-L/20(90)AAC [1] AV3: 660VL-L/20(90)AAC [2] AV4: 208VL-L/5(10)AAC [3] AV5: 400VL-L/5(10)AAC [1] AV6: 100VL-L/5(10)AAC [3] AV7: 660VL-L/5(10)AAC [2] Self Power Supply: AV2: 220VL-L/20(90)AAC [4] AV8: 208VL-L/20(90)AAC [1] AV9: 400VL-L/20(90)AAC [1] System 3: Three-phase, unbalanced load with or without neutral Power supply For all versions A: 24VAC -15+10%, 50-60Hz B: 48VAC -15+10%, 50-60Hz C: 115VAC -15+10%, 50-60Hz D: 230VAC -15+10%, 50-60Hz 4: 18 to 60VDC 5: 77 to 143VDC AV2, AV8 and AV9 only X: Self Power Supply 400VL-L (-20+15%, 50-60Hz) 208VL-L (-20+15%, 50-60Hz) 220VL-L (-10+15%, 50-60Hz) [3] Un: -20+20% Slot A (retransmission) X: O: None AO2900 module Dual open collector output Three operating modes: • two pulse outputs (kWh and kvarh); • one alarm output and one pulse output (kWh or kvarh) • one output which is remotely controlled by a serial port and one pulse output (kWh or kvarh) AO2910 module. One relay output + one open collector output. Operation modes like module AO2900. Slot B (retransmission) Only with A-B-C-D-4 power supply XX: None A1: AO2920 module 0-20mADC analogue output V1: AO2921 module 0-10VDC analogue output S0: AR2950 module RS422/485 serial port R: [1] Un: -20+15% [2] Un: -30+15% [4] Un: -10 +15% Specifications are subject to change without notice WM22-DINDS1003 1 WM22-DIN Input specifications Number of inputs Current Voltage Accuracy (display, RS485) 3 4 Ib: 5A, Imax: 10A Ib: 20A, Imax:90A Un: see previous page “Range code” from 0.003Ib to 0.2Ib: ±(0.5%RDG +3DGT) from 0.2Ib to Imax: ±(0.5%RDG +1DGT) in the range Un: ±(0,5% RDG + 1DGT) ±0.1% RDG (50 to 60 Hz) ±(1% RDG +1DGT). PF 1, 0.1Ib to Imax, in the Un range; PF 0.5L, PF 0.8C, 0.2Ib to Imax, in the Un range ±(2% RDG +1DGT). sinϕ 1, 0.05Ib to Imax, in the Un range; sinϕ 0.5L, sinϕ 0.5C, 0.1Ib to Imax, in the Un range ±(1% RDG +1DGT). PF 1, 0.1Ib to Imax, in the Un range Class 1 acc. to EN61036 Class 2 acc. to EN61268 Ib: 5A, Imax: 10A 0.1Ib: 500mA, Start up corrent: 20mA Un: see table “range code” Ib: 20A, Imax: 90A 0.1Ib: 2A, Start up current: 80mA Un: see table “range code” ±3% f.s. (f.s.: 100%) up to the 7th harmonic; Un: see table “range code” Imin: 500mA; Imax: 15Ap; Imin: 2A; Imax: 127Ap; Additional errors Wave form Voltage asymmetry Magnetic induction HF Electromagnetic fields Operation of accessories Temperature drift Sampling rate Display Type Instantan. variables read-out Energies Max. and Min. indication Measurements Acc. to EN61036, EN61268 720KΩ > 720KΩ > 1.97MΩ > 400KΩ < 0.3VA < 4VA < 4VA 50 to 60 Hz Current Voltage Frequency Active power (@ 25°C ± 5°C, R.H. ≤ 90%) Reactive power (@ 25°C ± 5°C, R.H. ≤ 90%) Apparent power (@ 25°C ± 5°C, R.H. ≤ 90%) Energies (@ 25°C ± 5°C, R.H. ≤ 90%) Harmonic distortion (@ 25°C ± 5°C, R.H. ≤ 90%) Ib 5A Ib 20A Coupling type Crest factor Ib 5A Ib 20A Current overload 5(10) A, for 10ms 5(10) A, for 500ms 5(10) A, permanent 20(90) A, for 10ms 20(90) A, permanent Voltage overload Permanent For 1s Input impedance 400VL-L (AV1-AV5-AV9) 208VL-L (AV0-AV4-AV8-AV2) 660VL-L (AV3-AV7) 100VL-L (AV6) 5(10) A (AV4-AV5-AV6-AV7) 20(90) A (AV0-AV1-AV3-AV8-AV9) 20(90) A (AV2) Frequency Interface module specifications Analogue outputs (on request) Number of outputs Range 1 0 to 20 mADC (AO2920 module slot B, only for versions with auxiliary power supply) 0 to 10VDC (AO2921 module slot B, only for versions with auxiliary power supply) ±0.5% F.S. ≤ 300 ppm/ °C Programmable within the whole range of retransmission; it allows the retransmission of all the values included in the following ranges: 0 and 20mADC, 0 and 10VDC Response time System variables FFT off, filter off FFT on, filter on variables Filter off Ripple Load 20 mADC 10 VDC Insulation V, W, VA, var, PF (cosϕ) 900ms 1.4s THD-V, THD-A 3s ≤ 1% according to IEC 60688-1, EN 60688-1 ≤ 500 Ω ≥ 10 kΩ By means of optocouplers, 2000 VRMS between output and measuring input WM22-DINDS1003 Accuracy Temperature drift Scaling factor 2 Specifications are subject to change without notice WM22-DIN Interface module specifications (cont.) 2000 VRMS between output and power supply input AR2950 module Multidrop bidirectional (static and and dynamic variables) 2 or 4 wires, max. distance 1200m, termination directly on the module 255, selectable by key-pad MODBUS/JBUS Phase and system variables: see table “Display pages” All the programming data, reset of energy, activation of static output. Stored energy (EEPROM) max. 19.999.999 kWh/kvarh 1 start bit, 8 data bit, no parity, 1 stop bit 9600 bit/s By means of optocouplers, 2000 VRMS output to measuring inputs 2000 VRMS output to supply input To be used as alarm, energy retransmission, or remote static outputs. Three working modes are selectable: • two pulse outputs (kWh and kvarh); • one alarm output and one pulse output (kWh or kvarh) • one output remotely controlled by means of the serial port and one pulse output (kWh or kvarh) 2 From 0.01 to 100 pulses programmable according to the selected CT and VT ratios Open collector (transistor NPN) VON 1.2 VDC / max. 100 mA VOFF 30 VDC max. 220 ms (ON), ≥ 220 ms (OFF) Insulation According to DIN43864 By means of optocouplers, 2000 VRMS outputs to measuring inputs, 2000 VRMS output to supply input. Insulation between the two outputs: functional 1 Up alarm, down alarm phase asymmetry, phase loss. 0 to 100% of the electrical scale 0 to 100% of the electrical scale 0 to 255 seconds V, W, VA, var, PF (cosϕ) 700ms 1.2s THD-V, THD-A 3s Open collector (transistor NPN) VON 1.2 VDC / max. 100 mA VOFF 30 VDC max. By means of optocouplers, 2000 VRMS output to measuring input, 2000 VRMS output to supply input. Insulation between the two outputs: functional Relay + open collector output. Working mode like AO2900. One static output+one relay output, other characteristics like AO2900. Only relay output, other characteristics like AO2900. Static type like module AO2900; Relay type: SPDT, AC1, AC15: 1AAC @250VAC By means of optocouplers, 2000 VRMS outputs to measuring inputs, 2000 VRMS output to supply input. Insulation between the two outputs: 2000 VRMS RS422/RS485 (on request) Type Connections Addresses Protocol Data (bidirectional) Dynamic (reading only) Static (writing only ) Alarm output Number of outputs Alarm type Setpoint adjustment Hysteresis On-time delay Response time system variables FFT off, filter off FFT on, filter on variables Filter off Output type Insulation Data format Baud-rate Insulation Digital outputs (on request) AO2900 module AO2910 module Pulse output Alarm output Output type Pulse outputs Number of outputs Number of pulses Insulation Output type Pulse duration Specifications are subject to change without notice WM22-DINDS1003 3 WM22-DIN Software functions Password Numeric code of max. 3 digits 2 protection levels of the programming data Password “0”, no protection Password from 1 to 1000, all data are protected Three-phase with neutral Three-phase without neutral 1 to 5000 1.0 to 199.9 and 200 to 1999 Note: The CT ratio* VT ratio must never exceed the value 5000. The current measuring inputs can manage CT’s with a secondary of 1A and 5A (the accuracy always refer to 5A) Compression/expansion of the measuring range to be connected to the analogue output. Electrical range Filter Filter operating range Filter coefficient Filter action Programmable within the whole measuring range. 0 to 99.9% of the input electrical scale. 1 to 16 Alarm, analogue and serial output (fundamental variables: V, A, W and their derived ones). Up to 4 variables per page Page 1: W-var-PF (cosϕ) Page 2: W dmd - VA dmd - Hz Page 3: THD-V Page 4: THD-A Page 5: kWh total Page 6: kvarh total Page 7: kWh partial Page 8: kvarh partial Page 9: VL-N Page 10: A Page 11a: A MAX Page 11b: W dmd MAX VA dmd MAX Page 12: W Page 13: VA Page 14: var Page 15: PF (cosϕ) 1st level 2nd level System selection Transformer ratio CT VT Display System variables Single phase variables System variables Single phase variables 20(90) A 5(10) A Scaling factor Operating mode Supply specifications Self supplied version 400VL-L -20% +15%, 50-60Hz 208VL-L -20% +15% , 50-60Hz 220VL-L -10% +15% , 50-60Hz 230VAC -15 +10%, 50-60Hz Energy consumption 115VAC -15 +10%, 50-60Hz 48VAC -15 +10%, 50-60Hz 24VAC -15 +10%, 50-60Hz 18 to 60VDC 77 to 143VDC ≤ 7VA Auxiliary power supply General Specifications Operating temperature Storage temperature Installation category Insulation Dielectric strength Noise rejection CMRR EMC Burst Immunity to irradiated electromagnetic fields Electrostatic discharges Radio frequency emissions 0 to +55°C (R.H. < 90% non-condensing 40°C) IEC664-1 Energy measurements: EN61036, EN61268. (R.H. < 90% non-condensing 40°C) Pulse output DIN43864 Cat. III (IEC 664) Approvals CE 2000 VRMS between all inputs / Connections 5(10) A Screw-type, outputs to earth Cable cross-section area 4 mm2 4000 VRMS for 1 minute Connections 20(90) A Screw-type, Min./Max. cable cross-section area 6 mm2 / 35 mm2 Min./Max. screws tightening torque 2 Nm / 6 Nm 100 dB, 48 to 62 Hz Housing Dimensions 162.5 x 90 x 63 mm 4kV/level 4 (EN61000-4-4) Material ABS, NORYL, PC self-extinguishing: UL 94 V-0 10V/m 26-1000MHz Mounting DIN-rail and wall (EN61000-4-3) Degree of protection Front: IP40 15kV (EN61000-4-2) Connections: IP20 according to CISPR 14 Weight 800 g approx. and CISPR 22 (packing included) -20 to +60°C Specifications are subject to change without notice WM22-DINDS1003 Pulse voltage (1.2/50µs) Standards Safety Metrology 8kV (EN61000-4-5) 4 WM22-DIN Function description Input and output scaling capability Working examples of the analogue output (Y) versus the input variable (x) - (input/output scaling possibilities). Figure A The sign of measured quantity and output quantity remains the same. The output quantity is proportional to the measured quantity. Figure B The sign of measured quantity and output quantity remains the same. With the measured quantity being zero, the output quantity already has the value Y1 = 0.2 Y2. Live zero output. 0 0 50 A 10 mA 100 A 20 mA 0 4 50 A 12 mA 100 A 20 mA Figure C The sign of measured quantity and output quantity remains the same. On the range X0...X1, the output quantity is zero. The range X1...X2 is delineated on the entire output range Y0=Y1...Y2 and thus presented in strongly expanded form. 80 V 0 100 V 5 mA 120 V 10 mA Mode of Operation Waveform of the signals that can be measured Figure D Sine wave, undistorted Fundamental content 100% Harmonic content 0% Arms = 1.1107 | A | Figure E Sine wave, indented Fundamental content 10...100% Harmonic contents 0...90% Frequency spectrum: 3rd to the 16th harmonic Additional error:
WM22-DINAV2BXA1 价格&库存

很抱歉,暂时无法提供与“WM22-DINAV2BXA1”相匹配的价格&库存,您可以联系我们找货

免费人工找货