WM3-96AV53H

WM3-96AV53H

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    WM3-96AV53H - Energy Management Modular Smart Power Quality Analyzer - List of Unclassifed Manufactu...

  • 数据手册
  • 价格&库存
WM3-96AV53H 数据手册
Energy Management Modular Smart Power Quality Analyzer Type WM3-96 • Class 0.5 (current/voltage) • 32-bit µP-based modular smart power quality analyzer • Graph display (128x64 dots) • Front size: 96x96 mm • Measurements of single phase and system variables: W, Wdmd, var, VA, VAdmd, PF, PFavg, V, A, An dmd (for all of them max. and min. values). Energies: kWh and kvarh on 4 quadrants. • Neutral current measurement • TRMS measurement of distorted waves (voltage/current) • Current and voltage inputs with autoranging capability • 4x4-dgt instantaneous variable read-out • 4x9-dgt total energies read-out • 4x6-dgt partial energies read-out • 48 independent energy meters to be used as single, dual, multi-time energy management • Display refresh time: 100 msec @ 50 Hz • Harmonic distorsion analysis (FFT) up to 50th harmonic with both graph and numerical indication (of current and voltage) • Harmonics source detection • Optional RS232 + real time clock function with data logging of alarm and MIN/MAX events, monthly energy metering recording • Degree of protection (front): IP 65 • Up to 4 optional alarm setpoints • Up to 4 optional pulse outputs • Up to 4 optional analogue outputs • Optional serial RS 422/485 output • Universal power supply: 18 to 60VAC/DC - 90 to 260 VAC/DC • MODBUS RTU, JBUS, (N2 METASYS protocols on request) Product Description 32-bit µP-based smart power quality analizer with a built-in configuration key-pad. The housing is for panel mounting and ensures a degree of protection (front) of IP 65. The instrument is particularly indicated for those application where there is the need to control the power supply quality. The variables being displayed are more than 400. Ordering Key Model Range code System Power supply Slot A Slot B Slot C Slot D Options WM3-96AV53H XX XX XX XX X Type Selection Range code AV5: 240/415 VAC 1/5 AAC (max. 300 V (L-N)/ 520 V (L-L) - 6 A) (standard) 400/690VAC 1/5 AAC (max. 480V (L-N) / 830 V (L-L) / 6 A 1) Slot A (signal retransmission) XX: A1: A2: A3: A4: B1: B2: B3: B4: V1: V2: V3: V4: W1: W2: W3: 1) Slot B (signal retransmission) XX: B1: B2: B3: B4: W1: W2: W3: W4: S1: None Dual analogue output, 20mADC (standard) Dual analogue output, ±5mADC 1) Dual analogue output, ±10mADC 1) Dual analogue output, ±20mADC 1) Dual analogue output, 10VDC (standard) Dual analogue output, ±1VDC 1) Dual analogue output, ±5VDC 1) Dual analogue output, ±10VDC 1) Serial port, RS485 multidrop, bidirectional 1) Slot C (alarm or pulse out) XX: R1: R2: O1: O2: D1: None Single relay output, (AC1-8AAC, 250VAC) 1) Dual relay output, (AC1-8AAC, 250VAC) 1) Single open collector output (30V/100mADC) 1) Dual open collector output (30V/100mADC) 1) 3 digital inputs 1) AV7: System 3: One phase, threephase system (3 or 4 wires, balanced load) Three phase system (3 or 4 wires, unbalanced load) Power supply L: H: 18 to 60VAC/DC 1) 90 to 260VAC/DC On request W4: None Single analogue output, 20mADC (standard) Single analogue output, ±5mADC 1) Single analogue output, ±10mADC 1) Single analogue output, ±20mADC 1) Dual analogue output, 20mADC (standard) Dual analogue output, ±5mADC 1) Dual analogue output, ±10mADC 1) Dual analogue output, ±20mADC 1) Single analogue output, 10VDC (standard) Single analogue output, ±1VDC 1) Single analogue output, ±5VDC 1) Single analogue output, ±10VDC 1) Dual analogue output, 10VDC (standard) Dual analogue output, ±1VDC 1) Dual analogue output, ±5VDC 1) Dual analogue output, ±10VDC 1) WM3-96DS260606 Slot D (alarm or pulse out) XX: R2: O2: O4: None Dual relay output, (AC1-8AAC, 250VAC) 1) Dual open collector output (30V/100mADC) 1) 4 open collector outputs (30V/100mADC) 1) Note: Slot A + Slot B Max 4 analogue outputs Slot C + Slot D max 4 digital outputs Options X: S: N: C: None Serial RS232 + RTC With N2 Metasys protocol options: S+N Specifications are subject to change without notice 1 WM3-96 Input Specifications Number of inputs Current 2 (system: single phase) 6 (system: 3-phase) Voltage 2 (system: single phase 4 (system: 3-phase) Digital 3 free of voltage contacts for Wdmd, VAdmd, An dmd, PFavg synchronization Reading voltage/current: 17.5 to 25VDC/500 kΩ) 1 AAC (≤ 0.3 VA) 58/100 V (>500 kΩ) 5 AAC (≤ 0.3 VA) 240/415 V (>500 kΩ) 1 AAC (≤ 0.3 VA) 240/415 V (>500 kΩ) 5 AAC (≤ 0.3 VA) 100/170 V ((>500 kΩ) 1 AAC (≤ 0.3 VA) 100/170 V (>500 kΩ) 5 AAC (≤ 0.3 VA) 400/690 V (>500 kΩ) 1 AAC (≤ 0.3 VA) 400/690 V (>500 kΩ) 5 AAC (≤ 0.3 VA) 40 to 440 Hz AV5: 300 VLN/520 VLL/6A AV7: 480 VLN/830 VLL/6A 600 VLN/1040 VLL/120A 960 VLN/1660 VLL/120A 4 keys: ”S” for enter programming phase and password confirmation, ”UP” and “DOWN” for value programming/function selection, page scrolling “F” for special functions Max. and min. indication Measurements Ranges (impedances) AV5 AV7 Frequency range Over-load protection Continuous: voltage/current For 1 s AV5 AV7 Keypad Output Specifications Analogue outputs (on request) Number of outputs Up to 4 (on request) Accuracy ±0.2% FS (@ 25°C ±5°C, R.H. ≤60%) Range 0 to 20 mADC, 0 to ±20 mADC 0 to ±10 mADC, 0 to ±5 mADC 0 to 10 VDC, 0 to ±10 VDC 0 to ±5 VDC 0 to ±1 VDC Specifications are subject to change without notice WM3-96DS260606 2 WM3-96 Output Specifications (cont.) Scaling factor Programmable within the whole range of retransmission; it allows the retransmission management of all values from: 0 to 20 mADC, 0 to ±20 mADC 0 to ±10 mADC, 0 to ±5 mADC 0 to 10 VDC, 0 to ±10 VDC 0 to ±5 VDC 0 to ±1 VDC All (see table“List of the variables that can be connected to:”...) ≤ 200 ms typical (filter excluded, FFT excluded 3 1/2 dgt indication) ≤ 1% according to IEC 60688-1 and EN 60688-1 200 ppm/°C ≤ 600 Ω ≤ 550 Ω ≤ 1100 Ω ≤ 2200 Ω ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ ≥ 10 kΩ By means of optocouplers, 4000VRMS output to measuring input 4000VRMS output to supply input Multidrop bidirectional (static and dynamic variables) 4 wires, max. distance 1200m, termination directly on the module 1 to 255, selectable by key-pad MODBUS RTU /JBUS, (N2 METASYS on request) All display variables (see also the table, “List of the variables that can be connected to”...) All configuration parameters, reset of energy, activation of digital output Stored energy (EEPROM) max. 999.999.999 kWh/kvarh 1-start bit, 8-data bit, no parity/even parity, odd parity, 1 stop bit 1200, 2400, 4800 and 9600 selectable bauds By means of optocouplers, 4000 VRMS output to measuring inputs 4000 VRMS output to supply input Bidirectional (static and dynamic variables) Connections Data format Baud-rate Protocol Other data Digital outputs (on request) 3 wires, max. distance 15m, 1-start bit, 8-data bit, no parity, 1-stop bit 9600 bauds MODBUS (JBUS) as for RS422/485 Up to 4 outputs (combination of alarms and pulse outputs) The working of the outputs: pulse or alarm or both of them is fully programmable and is independent from the chosen output module. Outputs remotely controlled by the serial communication port Up to 4, independent From 1 to 1000 programmable pulses for K-M-G Wh, K-M-G varh, open collector (NPN transistor) VON 1.2 VDC/ max. 100 mA VOFF 30 VDC max. Outputs connectable to total and partial energy meters 220 ms (ON), ≥ 220 ms (OFF) According to DIN43864 By means of optocouplers, 4000 Vrms output to measuring input, 4000Vrms output to supply input. The outputs can be either open collector type or relay type (for this latter one see the characteristics mentioned in the ALARMS). Up to 4, independent Up alarm, down alarm, up alarm with latch, down alarm with latch, phase assymetry, phase loss, neutral loss All (see table“List of the variables that can be connected to:”...) 0 to 100% of the electrical scale 0 to 100% of the electrical scale 0 to 255 s Selectable, Normally deenergized, normally energized Relay, SPDT AC 1-8A, 250VAC DC 12-5A, 24VDC AC 15-2.5A, 250VAC DC 13-2.5A, 24VDC ≤ 150 ms, filter excluded, FFT excluded, setpoint on-time delay: ”0s” 4000 VRMS output to measuring input, 4000VRMS output to supply input The outputs can be either relay type or open collector type (for this latter one, see the characteristics mentioned in the PULSE OUTPUTS). Variables to be retransmitted Response time Ripple Temperature drift Load: 20 mA output ±20 mA output ±10 mA output ± 5 mA output 10 V output ±10 V output ± 5 V output ± 1 V output Insulation Pulse outputs (on request) Number of outputs Type Pulse duration Insulation Note RS422/RS485 output (on request) Connections Addresses Protocol Data (bidirectional) Dynamic (reading only) Static (writing only) Alarms outputs (on request) Number of setpoints Alarm type Variables to be controlled Setpoint adjustment Hysteresis On-time delay Relay status Output type Data format Baud-rate Insulation Min. response time Insulation Note RS232 output (on request) Specifications are subject to change without notice WM3-96DS260606 3 WM3-96 Software Functions Password 1st level 2nd level Transformer ratio Scaling factor Operating mode Numeric code of max. 3 digits; 2 protection levels of the programming data Password “0”, no protection Password from 1 to 499, all data are protected For CT up to 30000 A, For VT up to 600 kV Electrical scale: compression/ expansion of the input scale to be connected to up to 4 analogue outputs. Programmable within the whole measuring range 0 to 99.9% of the input electrical scale 1 to 255 Filter action Display, alarm, analogue and serial outputs (fundamental variables: V, A, W and their derived ones) Only with RS232 + RTC module. The alarms max/min values will be stored with time (hh:mm:ss) and date (dd:mm:yy) references Max. capacity: 480 events Max. 4/page, one freely prog. page + 26 variable pages + according to the kind of period selection: up to 12 energy meter pages. English, Italian, French, German, Spanish Event logging Page Variables Electrical range Filter Filter operating range Filtering coefficient Display language Supply Specifications AC/DC voltage 90 to 260VAC/DC (standard), 18 to 60VAC/DC (on request), Power consumption ≤ 30VA/12W (90to 260V) ≤ 20VA/12W (18 to 60V) General Specifications Operating temperature Storage temperature Insulation reference voltage Insulation Dielectric strength Noise rejection CMRR EMC Other standards Safety requirements: Product requirements: 0 to +50°C (32 to 122°F) Product requirements (R.H. < 90% non-condensing) Pulse output: -10 to +60°C (14 to 140°F) (R.H. < 90% non-condensing) Approvals 300 VRMS to ground (AV5 input) 4000 VRMS between all inputs/ Connector outputs to ground Housing 4000 VRMS for 1 minute Dimensions Material 100 dB, 48 to 62 Hz EN 50081-2, EN 50082-2 Degree of protection IEC 61010-1, EN 61010-1 IEC 60688-1, EN 60688-1 Weight Energy measurements: EN61036, EN61268. DIN43864 CE, UL, CSA Screw-type, max. 2.5 mm2 wires x 2 96x96x140 mm ABS, self-extinguishing: UL 94 V-0 Front: IP65, NEMA4x, NEMA12 Approx. 600 g (packing included) 4 Specifications are subject to change without notice WM3-96DS260606 WM3-96 Function Description Input and output scaling capability Working of the analogue outputs (y) versus input variables (x) Figure A The sign of measured quantity and output quantity remains the same. The output quantity is proportional to the measured quantity. Figure D The sign of measured quantity and output quantity remains the same. With the measured quantity being zero, the output quantity already has the value Y1 = 0.2 Y2. Live zero output. 0 0 50 A 10 mA 100 A 20 mA 0 4 50 A 12 mA 100 A 20 mA Figure B The sign of measured quantity and output quantity changes simultaneously. The output quantity is proportional to the measured quantity. Figure E The sign of the measured quantity changes but that of the output quantity remains the same. The output quantity steadily increases from value X1 to value X2 of the measured quantity. -100 kW -1 kW 0 0 100 kW 1 kW -100 kW 0 0 10 mA 100 kW 20 mA Figure C The sign of measured quantity and output quantity remains the same. On the range X0...X1, the output quantity is zero. The range X1...X2 is delineated on the entire output range Y0 = Y1...Y2 and thus presented in strongly expanded form. 80 V 0 100 V 5 mA 120 V 10 mA Figure F The sign of the measured quantity remains the same, that of the output quantity changes as the measured quantity leaves range X0...X1 and passes to range X1...X2 and vice versa. 0 -1 V 50 A 0 100 A 1V Mode of Operation Waveform of the signals that can be measured Figure G Sine wave, undistorted Fundamental content 100% Harmonic content 0% 1.1107 | A | Arms = Figure H Sine wave, indented Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum 3rd to 50th harmonic Figure I Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum 3rd to 50th harmonic Specifications are subject to change without notice WM3-96DS260606 5 WM3-96 Harmonic distortion analysis Analysis principle Harmonic measurement Current Voltage Type of harmonics FFT Up to 50th harmonic Up to 50th harmonic THD (VL1) THD odd (VL1) THD even (VL1) and also for the other phases: L2, L3. THD (IL1) THD odd (IL1) THD even (IL1) and also for the other phases: L2, L3. The instrument measures the angle between the single harmonic of “V” and the single harmonic of “I” of the same order. According to the value of the electrical angle, it is possible to know if the distortion is absorbed or generated. Note: if the system has 3 Harmonic details wires the angle cannot be measured. For every THD page it is possible to see the harmonic order. The harmonics content is displayed as a graph showing the whole harmonic spectrum. The information is given also as numerical information: THD in % / RMS value THD odd in % / RMS value THD even in % / RMS value single harmonic in % / RMS value The harmonic distortion can be measured in 2-wire, 3-wire or 4-wire systems. Tw: 0.02 Display pages Harmonic phase angle Others Energy time period management Time periods Single time Number of energy meters Dual time Number of energy meters Time periods Multi time Number of energy meters Time periods Time seasons Pulse outputs Selectable: single time, dual time and multi-time Total: 4 (9-digit) (no partial meters) (b) Total: 4 (9-digit) Partial: 8 (6-digit) 2, programmable within 24 hours Total: 4 (9-digit) Partial: 48 (6-digit) 4, programmable within 24 hours 3, programmable within 12 months Connectable to total and partial energy meters (Single time, dual time, multi time periods) Energy consumption story, recording of energy metering by months, oldest data: 2 months before current month. Recording of total and partial energy metering max. 3 (c) Season (12 months) Management concept (multi-time) (a) max. 4 Time period (24 hours) +Wh, +VArh, –Wh, -VArh Partial: up to 48 energy meters (axbxc) Total: up to 4 energy meters (“a” type) Example of Multi-time energy metering WINTER trf start end 1 OO:OO O6:OO 2 O6:OO O8:OO 3 O8:OO 1O:OO 1 TARIFF Energy metering recording trf1 22 24 2 trf1 4 6 8 trf4 20 18 trf3 16 14 trf2 trf2 12 10 trf3 WINTER trf start end 1O:OO 16:OO 2 3 16:OO 18:OO 4 18:OO 21:OO 1 21:OO OO:OO 1 TARIFF 6 Specifications are subject to change without notice WM3-96DS260606 WM3-96 Display pages Variables that can be displayed in case of a three-phase system, 4-wire connection. No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1st variable 2nd variable 3rd variable Selectable Selectable Selectable V L1 V L2 V L3 V L1-2 V L2-3 V L3-1 A L1 A L2 A L3 W L1 W L2 W L3 var L1 var L2 var L3 VA L1 VA L2 VA L3 PF L1 PF L2 PF L3 V L1 A L1 PF L1 V L2 A L2 PF L2 V L3 A L3 PF L3 V L-L sys PF sys var sys An PF sys Hz A n dmd VA dmd PF avg (MAX1) (MAX2) (MAX3) (MAX5) (MAX6) (MAX7) (MAX9) (MAX10) (MAX11) (MIN1) (MIN2) (MIN3) (MIN5) (MIN6) (MIN7) Histogram FFT V1 (THD, TADo, THDe, Single harmonic) Histogram FFT A1 (THD, TADo, THDe, Single harmonic) Histogram FFT V2 (THD, TADo, THDe, Single harmonic) Histogram FFT A2 (THD, TADo, THDe, Single harmonic) Histogram FFT V3 (THD, TADo, THDe, Single harmonic) Histogram FFT A3 (THD, TADo, THDe, Single harmonic) KWh + TOT KWh – TOT Kvar+ TOT KWh+ KWh– Kvar+ 4th variable Selectable V L-N sys V L-L sys An W sys var sys VA sys PF sys W L1 W L2 W L3 W sys W sys W dmd (MAX4) (MAX8) (MAX12) (MIN4) (MIN8) Note Sys = Σ Sys = Σ Sys = Σ Sys = Σ Sys = Σ Sys = Σ Sys = Σ dmd=demand, avg=average The MAX value can be one of the above mentioned (No. 1 to No. 13) The MIN value can be one of the above mentioned (No. 1 to No. 13) Only if analysis V1-A1 is activated Only if analysis V1-A1 is activated Only if analysis V2-A2 is activated Only if analysis V2-A2 is activated Only if analysis V3-A3 is activated Only if analysis V3-A3 is activated Partial energy meters Kvar– TOT Kvar– Used Calculation Formulas Formulas being used for single-phase measurements Instantaneous effective voltage Formulas being used for 3-phase measurements Tn,i - value of parameter T at the n’th harmonic of phase i Equivalent three-phase voltage Energy metering Three-phase reactive power Neutral current Instantaneous active power An = AL1+AL2+AL3 Three-phase active power Instantaneous power factor Three-phase apparent power Instantaneous effective current Equivalent three-phase power factor (TPF) Total harmonic distortion Instantaneous reactive power kWhi = total consumed active energy at phase i kVArhi = total consumed reactive energy at phase i Pi(t) = total RMS active power at phase i of time t Qi(t) = total RMS reactive power at phase i of time t t1 t2 = starting and ending time points of consumption recording Pn,i = total RMS active power at phase i of discrete time n Qn,i = total RMS reactive power at phase i of discrete time n ∆t = time interval between two successive power consumptions n1, n2 = starting and ending discrete time points of consumption recording Instantaneous apparent power Harmonic values: THDi-THD of parameter T at phase i Specifications are subject to change without notice WM3-96DS260606 7 WM3-96 List of the variables that can be connected to: • max/min variable detection; • analogue outputs; • alarm outputs. No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Variable V L1 V L2 V L3 V L-N sys V L1-2 V L2-3 V L3-1 V L-L sys A L1 A L2 A L3 An W L1 W L2 W L3 W sys var L1 var L2 var L3 var sys VA L1 VA L2 VA L3 VA sys PF L1 PF L2 PF L3 PF sys Hz THD V1 THDo V1 THDe V1 THD V2 THDo V2 THDe V2 THD V3 THDo V3 THDe V3 THD A1 THDo A1 THDe A1 THD A2 THDo A2 THDe A2 THD A3 THDo A3 THDe A3 A n dmd VA dmd PF avg W dmd ASY 1-phase Sys. o o o o x o o o x o o o x o o o x o o o x o o o x o o o x x x x o o o o o o x x x o o o o o o x x x x o 3-ph. + N Bal. Sys. x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 3-ph. + N Unbal. Sys. x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 3-ph. Bal. Sys. o o o o x x x x x x x o o o o x o o o x o o o x o o o x x x x x x x x x x x x x x x x x x x x x x x x x 3-ph. Unbal. Sys. o o o o x x x x x x x o o o o x o o o x o o o x o o o x x x x x x x x x x x x x x x x x x x x x x x x x Note Sys = Σ Sys = Σ Neutral current Sys = Σ Sys = Σ Sys = Σ Sys = Σ if FFT V1-A1 is activated if FFT V1-A1 is activated if FFT V1-A1 is activated if FFT V2-A2 is activated if FFT V2-A2 is activated if FFT V2-A2 is activated if FFT V3-A3 is activated if FFT V3-A3 is activated if FFT V3-A3 is activated if FFT V1-A1 is activated if FFT V1-A1 is activated if FFT V1-A1 is activated if FFT V2-A2 is activated if FFT V2-A2 is activated if FFT V2-A2 is activated if FFT V3-A3 is activated if FFT V3-A3 is activated if FFT V3-A3 is activated Integration time programmable from 1 to 30 minutes Integration time prog. from 1 to 30 min. Integration time prog. from 1 to 30 min. Integration time prog. from 1 to 30 min. Integration time prog. from 1 to 30 min. Note: (x) stands for an “available” variable, (o) stands for a “not-available” variable. 8 Specifications are subject to change without notice WM3-96DS260606 WM3-96 The available modules Type WM3-96 base WM3-96 N2 METASYS base AV5.3 measuring inputs AV7.3 measuring inputs 18-60VAC/DC power supply 90-260VAC/DC power supply 20mADC analogue output 10VDC analogue output ±5mADC analogue output ±10mADC analogue output ±20mADC analogue output ±1VDC analogue output ±5VDC analogue output ±10VDC analogue output 20mADC analogue output 10VDC analogue output ±5mADC analogue output ±10mADC analogue output ±20mADC analogue output ±1VDC analogue output ±5VDC analogue output ±10VDC analogue output RS485 output Relay output Relay output Open collector output Open collector output Open collector output Digital inputs RS232 output + RTC (1) N. of channels Ordering code AD 1016H AD 1016HN2 AQ 1018 AQ 1019 AP1021 AP1020 AO1050 AO1051 AO1052 AO1053 AO1054 AO1055 AO1056 AO1057 AO1026 AO1027 AO1028 AO1029 AO1030 AO1031 AO1032 AO1033 AR1034 AO1058 AO1035 AO1059 AO1036 AO1037 AQ1038 AR1039 The possible module combinations Basic unit Slot A Slot B Slot C Slot D Single analogue output Dual analogue output RS485 input/output Single relay output (*) Single open collector out (*) Dual relay output (*) Dual open coll. out (*) 4 open coll. output (*) 3 digital inputs Basic unit Slot E RS232 input/output + RTC (*) alarm or pulse 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 2 1 2 4 3 1 N2-Open Metasys protocol full compatibility (available on request). (1) The RS232 communication port works as alternative of the RS485 module. Wiring Diagrams Single phase input connections Fig. 1 Fig. 2 Fig. 3 Direct connection CT connection WM3-96DS260606 CT and VT connection Specifications are subject to change without notice 9 WM3-96 Wiring Diagrams (cont.) Three-phase wire input connections - Balanced loads Fig. 4 Fig. 5 Fig. 6 Direct connection (3-wire system) Fig. 7 CT connection (3-wire system) Fig. 8 CT and VT connection (3-wire system) Fig. 9 Direct connection (4-wire system) CT connection (4-wire system) CT and VT connection (4-wire system) Three-phase, 3-wire ARON input connections - Unbalanced loads Fig. 10 Fig. 11 Three-phase, 3-wire input connections - Unbalanced loads Fig. 12 CT connection (3-wire system) CT and VT connection (3-wire system) CT and VT connection (3-wire system) 10 Specifications are subject to change without notice WM3-96DS260606 WM3-96 Wiring Diagrams (cont.) Three-phase three-wire input connections Unbalanced load Fig. 13 Three-phase four-wire input connections - Unbalanced load Fig. 14 Fig. 15 CT connection (3-wire system) CT connection (4-wire system) CT and VT connection (4-wire system) Wiring diagrams (optional modules) AO1050 1 analogue output (mA) AO1026 2 analogue outputs (mA) VDC VDC AO1051 1 analogue output (V) AO1027 2 analogue outputs (V) AO1038 3 digital inputs VDC VDC AO1058 1 relay output AO1035 2 relay outputs AO1037 4 open collector outputs: The load resistance (Rc) must be designed so that the closed contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30V. VDC: power supply voltage output. Vo+: positive output contact (open collector transistor). GND: ground output contact (open collector transistor). Specifications are subject to change without notice WM3-96DS260606 11 WM3-96 Wiring diagrams (optional modules, cont.) RS422/485 4-wires connection: additional devices provided with RS422/485 (that is RS 1, 2, 3...N) are connected in parallel. The termination of the serial output is carried out only on the last instrument of the network, by means of a jumper between (Rx+) and (T). RS422/485 2-wires connection: additional devices provided with RS422/485 (that is RS 1, 2, 3...N) are connected in parallel. The termination of the serial output is carried out only on the last instrument of the network, by means of a jumper between (Rx+) and (T). Front Panel Description - for value programming/function selection, page scrolling - “F” for special functions 2 2. Display Istantaneous measurements: - 4-digit (maximum read-out 9999) Energies: - 9-digit (maximum read-out 999999999). Alphanumeric indication by means of LCD display for: - Displaying the configuration parameters - All the measured variables. 1 1. Key-pad Set-up and programming procedures are easily controlled by the 4 pushbuttons. - ”S” for enter programming phase and password confirmation, Dimensions 12 Specifications are subject to change without notice WM3-96DS260606 WM3-96 Terminal boards Single analogue output modules AO1050 AO1051 AO1052 AO1053 AO1054 AO1055 AO1056 AO1057 (20mADC) (10VDC) (±5mADC) (±10mADC) (±20mADC) (±1VDC) (±5VDC) (±10VDC) Dual analogue outputs AO1026 AO1027 AO1028 AO1029 AO1030 AO1031 AO1032 AO1033 (20mADC) (10VDC) (±5mADC) (±10mADC) (±20mADC) (±1VDC) (±5VDC) (±10VDC) Digital output modules AO1058 Single relay output AO1035 Dual relay output AO1059 Single open collector output AO1036 Dual open collector output Other input/output modules AR1039 RS232 port + RTC AO1037 4 open collector outputs AQ1038 3 Digital inputs AR1034 RS485 port Power supply modules AP1021 18-60VAC/DC power supply AP1020 90-260 VAC/DC power supply WM3-96DS260606 Specifications are subject to change without notice 13
WM3-96AV53H 价格&库存

很抱歉,暂时无法提供与“WM3-96AV53H”相匹配的价格&库存,您可以联系我们找货

免费人工找货