Key Data
3 x 800A AC at 690V AC, watercooled
Preliminary Data
General Information
Stack with IGBT, heatsinks, capacitors, drivers and sensors for several inverter applications. These are only technical data! Please read heedful the complete documentation and attend the adopted design environment! Especially the EMC environment and the controller functionality. Topology Load Type Cooling Targed Application Extra Drivercore Monitors Module (Unit1) Module (Unit2) Interface Standards IGBT DC Link + 2B6I Resistive, inductive load By Water Industrial Drive Available in Master [M] or Slave [S] Configuration Scale Driver Current-, Voltage-, Temperature-Monitoring n.a. 6x FF800R17KF6C Electrical, opt. optical EN50178, UL94, prepared for UL508C Master 23482 Slave 23483 38000002_B_MB 57000002 Unit 1
B6I
Unit 2
= ˜ ˜
DRIVER DC LINK B6I
=
SIGNAL CONDITIONER & MONITOR INTERFACE
= ˜ ˜
DRIVER
Product ID (eupec) Drawing No. Circuit Diagram No.
Electrical Data
Assumed Linevoltage DC Link Voltage DC Link Overvoltage Shutdown DC Link Current Voltage Unit1 Continious Current Unit1 Shorttime Current Unit1 Pulse Current Unit1
Parameter For IsolationManagement Within 100µs At IUnit2, VUnit2, cos_ϕUnit2 Min Typ Max
VLine VDC IDCLink Input VUnit1 IUnit1 IUnit1_10
690 975 VDCmax 890 1219
VRMS Vav V Aav VRMS ARMS ARMS Apeak 2003-03-17
ϑ=ϑair_inlet
10s, every 180s, initial load = IUnit1 Sinehalfwave 20ms
2B6I690-1100-400W.doc
1 of 10
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S
DC Current at Unit1
No rotating field, ϑ=ϑair_inlet, Percentage of IUnit1. Within 15µs
Preliminary Data
Aav % 690 -0,9 +0,9 800 Hz W VRMS ARMS
IUnit1_DC
Overcurrent Shutdown Unit1 Switching Freq. Unit1 Power Losses Unit1 V=Vunit1_min, I=IUnit1, fsw=fsw1 Depending on Voltage Unit2
Controller
fsw1 Ploss1 VUnit2
cos_ϕUnit2
Displacement factor Continious Current Unit2
ϑ=ϑwater_inlet, ϑchip 5Hz
Both B6I connected in parallel (1U1 ->2U1..) ϑwater_inlet -25°C
-25 2 900 0 0
vAir_PCB
Standard atmosphere No Condensation EN60068-2-6, Fc
pAir Rel. F
2B6I690-1100-400W.doc
4 of 10
2003-03-17
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S
10..59Hz 0,075mm
Preliminary Data
20 100 IP00 2 III m/s² m/s²
Permanence Vibration EN60068-2-6, Fc Shock Protection Degree Pollution Degree Overvoltage Category
10-150Hz, 20 Cycles EN60068-2-27, Ea Halfsine 11ms, 3 pulses
2B6I690-1100-400W.doc
5 of 10
2003-03-17
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S
Derating Curves (IGBT Part)
Current derating at low rotating field frequency (f0). Maximal 100% current is allowed.
cos(phi) = 0.64, (motor) Theta_air = 40°C
120 100 80 60 40 20 0 -5 0 5 10 15 20 25 f0 [Hz] 30 35 40 45 50 55
Preliminary Data
I/I_nom [%]
cos(phi) = -0.64, (generator) Theta_air = 40°C
120 100 80 60 40 20 0 -5 0 5 10 15 20 25 f0 [Hz] 30 35 40 45 50 55
2B6I690-1100-400W.doc
I/I_nom [%]
6 of 10
2003-03-17
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S Preliminary Data
Current derating at different switching frequencies. See datatable for nominal switching frequency. In this drawing 2500Hz ist assumed. Maximal 100% current is allowed. IGBT, cos(phi) = 0.64 Theta_air = 40°C
180 160 140 120 I/I_nom [%] 100 80 60 40 20 0 0 1000 2000 3000 4000 5000 6000 7000 fsw [Hz] FF 400 R12 KL4C FF 800 R17 KF6CB2 FF 1200 R17 KE3
Diode, cos(phi) = 0.64 Theta_air = 40°C
200 180 160 140 I/I_nom [%] 120 100 80 60 40 20 0 0 1000 2000 3000 4000 5000 6000 7000 fsw [Hz] FF 400 R12 KL4C FF 800 R17 KF6CB2 FF 1200 R17 KE3
2B6I690-1100-400W.doc
7 of 10
2003-03-17
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S
IGBT, cos(phi) = - 0.64 Theta_air = 40°C
180 160 140 120 I/I_nom [%] 100 80 60 40 20 0 0 1000 2000 3000 4000 5000 6000 7000 fsw [Hz] FF 400 R12 KL4C FF 800 R17 KF6CB2 FF 1200 R17 KE3
Preliminary Data
Diode, cos(phi) = -0.64 Theta_air = 40°C
180 160 140 120 I/I_nom [%] 100 80 60 40 20 0 0 1000 2000 3000 4000 5000 6000 7000 fsw [Hz] FF 400 R12 KL4C FF 800 R17 KF6CB2 FF 1200 R17 KE3
2B6I690-1100-400W.doc
8 of 10
2003-03-17
PowerSTACK
Datasheet: 2B6I 690/1100-400W M, S
Miscellaneous
This technical information specifies semiconductor stacks but promises no characteristics. It is valid in combination with the belonging technical notes. This document may be changed without prior notice.
Preliminary Data
Warning!
Prior to installation and commissioning all safety notices and warnings and all warning signs attached to the equipment have to be carefully read. Make sure that all warning signs remain in a legible condition and missing or damaged signs are replaced. The safety instructions have to be strictly adhered to. The manual contains detailed information on all technical topics with regard to the eupec PowerSTACK. For further details regarding publications of the eupec PowerSTACK and information on other publications in the area of PowerSTACKs please contact your nearest eupec branch or visit our website: http://www.eupec.com. eupec GmbH 2003. All rights reserved Prepared by Approved by J.Schiele H.Nübel 2003-04-03 2003-04-03 Date of publication Revision 0
2B6I690-1100-400W.doc
9 of 10
2003-03-17
PowerSTACK 2B6I 690/1100-400W M, S, Drawing, Preliminary Data
2B6I690-1100-400W.doc
10 of 10
2003-03-17
很抱歉,暂时无法提供与“2B6I690-1100-400WS”相匹配的价格&库存,您可以联系我们找货
免费人工找货