AUIR3317

AUIR3317

  • 厂商:

    EUPEC(英飞凌)

  • 封装:

    TO-220-3

  • 描述:

    IC PWR SWITCH N-CHAN 1:1 TO220

  • 数据手册
  • 价格&库存
AUIR3317 数据手册
August, 25th 2011 Automotive grade AUIR3317(S) LOW EMI CURRENT SENSE HIGH SIDE SWITCH Features x x x x x x x x Product Summary Rds(on) 7 m: max. Vcc op. 6 to 26V Current Ratio 8800 Over-current 120A Vclamp 40V Load current feedback Over current shutdown Active clamp ESD protection Input referenced to Vcc Over temperature shutdown Switching time optimized for low EMI Reverse battery protection Package Description The AUIR3317(S) is a fully protected 4 terminals high side switch. The input signal is referenced to Vcc. When the input voltage Vcc - Vin is higher than the specified threshold, the output power Mosfet is turned on. When the Vcc - Vin is lower than the specified Vil threshold, the output Mosfet is turned off. A current proportional to the power Mosfet current is sourced to the Ifb pin. Either over current and over temperature latches off the switch. The device is reset by pulling the input pin high. Other integrated protections (ESD, reverse battery, active clamp) make the switch very rugged in automotive environment. TO-220 AUIR3317 D²Pak Pin 4 and 5 fused AUIR3317S Typical Connection Vcc IN AUIR3317S Battery Current feeback Input On Off www.irf.com 10k Ifb Out Load Rifb Logic Ground Power Ground 1 AUIR3317(S) Qualification Information† Qualification Level Automotive (per AEC-Q100††) Comments: This family of ICs has passed an Automotive qualification. IR’s Industrial and Consumer qualification level is granted by extension of the higher Automotive level. D2PAK-5L MSL1, 260°C (per IPC/JEDEC J-STD-020) TO220-5L Not applicable Moisture Sensitivity Level Class M4 (450V) (per AEC-Q100-003) Class H3A (4,500 V) ESD Human Body Model (per AEC-Q100-002) Class C4 (1000 V) Charged Device Model (per AEC-Q100-011) Class II, Level A IC Latch-Up Test (per AEC-Q100-004) RoHS Compliant Yes † Qualification standards can be found at International Rectifier’s web site http://www.irf.com/ †† Exceptions to AEC-Q100 requirements are noted in the qualification report. Machine Model www.irf.com 2 AUIR3317(S) Absolute Maximum Ratings Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. All voltage parameters are referenced to Vcc lead. (Tj=-40°..150°C, Vcc=6..26V Tambient=25°C unless otherwise specified). Symbol Parameter Vcc-Vin Maximum Vcc voltage Vcc-Vin cont. Maximum continuous Vcc voltage Vcc-Vfb Maximum Ifb voltage Vcc-Vout Maximum output voltage Ids cont. Maximum body diode continuous current Rth=60°C/W (1) Tambient=25°C Ids pulsed Maximum body diode pulsed current (1) Pd Maximum power dissipation Rth=60°C/W Tambient=25°C Tj max. Max. storage & operating temperature junction temperature Min Rfb Minimum on the resistor on Ifb pin Ifb max. Max. Ifb current (1) Limited by junction temperature. Pulsed is also limited by wiring Min. Max. -16 -16 -16 -0.3 37 26 33 37 2.8 100 2 150    Units V A 50 W °C k: mA Typ. Max. Units 60 0.7 0.7    °C/W -40 0.3 -50  Thermal Characteristics Symbol Parameter Rth1 Rth2 Rth2 Thermal resistance junction to ambient D²-Pak Std footprint Thermal resistance junction to case D²-Pak Thermal resistance junction to case TO220 Recommended Operating Conditions These values are given for a quick design. For operation outside these conditions, please consult the application notes. Symbol Parameter Iout Continuous output current Tambient=85°C, Rth=5°C/W, Tj=125°C Tambient=85°C, Rth=60°C/W, Tj=125°C Minimum turn-on pulse width Maximum operating frequency Pulse min. Fmax. www.irf.com Min. Max. Units 23 7 A  1   200 ms Hz 3 AUIR3317(S) Protection Characteristics Tj=-40°..150°C, Vcc=6..26V Symbol Parameter Min. Typ.  165 Over temperature threshold Over voltage protection (not latched) 26 29 Fixed over current shutdown 90 120  50 Time to reset protection  900 Min. pulse width (no WAIT state) WAIT function timer 0.4 1 Reverse battery On state resistance 4 6.7 Tj=25°C  10 TJ=125°C (3) With Vcc-Vifb4V(3) See fig. 5 Tj=25°C See fig. 4 and 5 Vcc-Vin=-14V, Iout=30A 15 Static Electrical Characteristics Tj=-40°..150°C, Vcc=6..26V (unless otherwise specified) Symbol Parameter Vcc op. Icc off Operating Voltage range Supply leakage current Iin, on Vih Vil Vhyst Iout On state IN positive current High level Input threshold voltage (4) Low level Input threshold voltage (4) Input hysteresis Vih-Vil Drain to source leakage current Min. Typ. Max. Units 6  V  1.5 26 5 1.5 6 6.3 5.8 1.5 5 mA  3 5.4 4.9 0.4 1.2 Min. Typ. Max. Units 30 20 30 120 50 80 14 140 100 7 300 125 200 μs  4 0.2 μA Test Conditions Vin=Vcc, Vcc-Vout=14V, Vcc-Vifb=14V, Tj=25°C Vcc-Vin=14V, Tj=25°C V Vin=Vcc, Vcc-Vifb=0V, Vcc-Vout=14V, Tj=25°C Rds(on) On state resistance (5) Tj=25°C 4 5.5 7 Iout=30A, Vcc-Vin=14V On state resistance (5) Tj=25°C 4 6 10 Iout=17A, Vcc-Vin=6V m: Iout=30A, Vcc-Vin=14V On state resistance (5)(6) Tj=150°C 7 10.5 13.5  Iout=50mA V clamp1 Vcc to Vout clamp voltage 1 36 39 V  40 43 Iout=30A, Tj=25°C V clamp2 Vcc to Vout clamp voltage 2 (4) Input thresholds are measured directly between the input pin and the tab. Any parasitic resistance in common between the load current path and the input signal path can significantly affect the thresholds. (5) Rdson is measured between the tab and the Out pin, 5mm away from the package. (6) Guaranteed by design μA Switching Electrical Characteristics Vcc=14V, Resistive load=0.5:, Tj=25°C Symbol Parameter tdon tr1 tr2 Eon tdoff tf Eoff Turn on delay time to 10% Vcc Rise time to Vcc-Vout=5V Rise time to Vcc-Vout=0.1Vcc Turn on energy Turn off delay time Fall time to Vout=10% of Vcc Turn off energy www.irf.com  30 35   mJ 350 250 μs  mJ Test Conditions See figure 2 4 AUIR3317(S) Current Sense Characteristics Tj=-40°..150°C, Vcc=6..26V (unless otherwise specified) Symbol Parameter Min. Typ. Max. Units Ratio Ratio_TC Offset trst I Load/Iifb current ratio I Load/Iifb variation aver temperature(6) Load current diagnostic offset Ifb response time (low signal) 8,200 -5 -0.2 8,800 9,950 +5 +0.25   0 1  Rfb=500:, Iout=60A Tj=-40°C to 150°C Iout=2A 90% of the Iout step % A μs  Test Conditions Functional Block Diagram All values are typical VCC Driver Charge Pump 43V On/Off Fast turn-off 3mA 43V 38V + + 29V 43V Reset Set Latch Q Wait timer 1 ms - timer 400μs 80: Iout > 120A Tj > 165°C IN www.irf.com + Min. Pulse reverse battery protection IFB OUT 5 AUIR3317(S) Lead Assignments 3- Vcc 3- Vcc 1- In 2- Ifb 3- Vcc (tab) 4- NC 5- Out 1- In 2- Ifb 3- Vcc (tab) 4- Out 5- Out 12 45 D²Pak 1 2 3 4 5 TO220 90% Vcc-Vin Vih Vil Vhyst Icc Vcc IN Iin Ifb Ifb Vcc-Vout Vclamp1 Vclamp2 IR3317 10% tr-in 90% Vc c-5V Vout Out 10% Iout Isd Figure 1 – Voltages and current definitions www.irf.com Vcc-Vin td on td off tf tr1 tr2 Figure 2 – Switching time definitions 6 AUIR3317(S) Vcc-Vin t clamp Vin Iout t min. pulse t min. pulse Wait Iout Vcc Vout Vcc - V clamp See Application Notes to evaluate power dissipation Figure 3 – Active clamp waveforms Figure 4 – Min. pulse and Wait function Vcc-Vin t < t reset t > t reset t < t reset Wait t > t reset Wait Over-current shutdown Iout Over-temperature shutdown Tj Figure 5 – Protection Timing Diagrams www.irf.com 7 AUIR3317(S) All curves are typical characteristics. Operation in hatched areas is not recommended. Tj=25°C, Rifb=500ohm, Vcc=14V (unless otherwise specified). 6 Icc, supply current (mA) 8 6 4 2 0 0 10 20 30 40 50 Icc off, supply leakeage current (μA) 10 5 4 3 2 1 0 -50 0 Vcc-Vin, supply voltage (V) 100 150 Tj, junction temperature (°C) Figure 6 – Icc (mA) Vs Vcc-Vin (V) Figure 7 – Icc off (μA) Vs Tj (°C) 6 200% 5 150% 4 Vih, and Vil (V) Rds(on), Drain-to-Source On Resistance (Normalized) 50 100% VIH VIL 3 2 1 50% -50 0 50 100 Tj, junction temperature (°C) Figure 8 - Normalized Rds(on) (%) Vs Tj (°C) www.irf.com 150 0 -50 -25 0 25 50 75 100 125 Tj, junction temperature (°C) Figure 9 – Vih and Vil (V) Vs Tj (°C) 8 150 AUIR3317(S) 18 100 With calibration 14 Spec. Max. Isd, over current shutdown (A) 16 Error (+/-A) 12 10 8 6 4 2 0 0 20 40 60 80 10 100 100 1000 10000 Rifb, feedback resistor (:) I load, load current (A) Figure 11 – Ids (A) Vs Rifb (:) Figure 10 – Error (+/- A) Vs I load (A) 30 100 60°C/W Max. output current (A) Max. output current (A) 35°C/W 20 10 0 10 -50 0 50 100 Tamb., ambient temperature (°C) Figure 12 – Max. Iout (A) Vs Tamb. (°C) www.irf.com 150 10 100 1000 Inductance (μH) Figure 13 – Max. Iout (A) Vs inductance (μH) 9 AUIR3317(S) 100 Tamb=25°C Ids, output current (A) Tamb=100°C 10 1.E-01 1.E+00 1.E+01 1.E+02 1.E+03 Protection response time (s) Figure 14 – Ids (A) Vs over temperature protection response time (s) www.irf.com Zth, transient thermal impedance (°C/W) 100 50°C/W free air 5°C/W 10 1 0.1 1.E-4 1.E-3 1.E-2 1.E-1 1.E+0 1.E+1 1.E+2 Time (s) Figure 15 – Transient thermal impedance (°C/W) Vs time (s) 10 AUIR3317(S) Case Outline - TO220 - 5 Leads www.irf.com 11 AUIR3317(S) Case Outline - D2PAK – 5 leads www.irf.com 12 AUIR3317(S) Tape & Reel - D2PAK – 5 leads www.irf.com 13 AUIR3317(S) Part Marking Information Ordering Information Base Part Number Standard Pack Package Type Form TO220 – 5Leads AUIR3317 www.irf.com D2Pak – 5Leads Complete Part Number Quantity Tube 50 AUIR3317 Tube 50 AUIR3317S Tape and reel left 800 AUIR3317STRL Tape and reel right 800 AUIR3317STRR 14 AUIR3317(S) IMPORTANT NOTICE Unless specifically designated for the automotive market, International Rectifier Corporation and its subsidiaries (IR) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or services without notice. Part numbers designated with the “AU” prefix follow automotive industry and / or customer specific requirements with regards to product discontinuance and process change notification. All products are sold subject to IR’s terms and conditions of sale supplied at the time of order acknowledgment. IR warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with IR’s standard warranty. Testing and other quality control techniques are used to the extent IR deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. IR assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using IR components. To minimize the risks with customer products and applications, customers should provide adequate design and operating safeguards. Reproduction of IR information in IR data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alterations is an unfair and deceptive business practice. IR is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of IR products or serviced with statements different from or beyond the parameters stated by IR for that product or service voids all express and any implied warranties for the associated IR product or service and is an unfair and deceptive business practice. IR is not responsible or liable for any such statements. IR products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or in any other application in which the failure of the IR product could create a situation where personal injury or death may occur. Should Buyer purchase or use IR products for any such unintended or unauthorized application, Buyer shall indemnify and hold International Rectifier and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that IR was negligent regarding the design or manufacture of the product. Only products certified as military grade by the Defense Logistics Agency (DLA) of the US Department of Defense, are designed and manufactured to meet DLA military specifications required by certain military, aerospace or other applications. Buyers acknowledge and agree that any use of IR products not certified by DLA as military-grade, in applications requiring military grade products, is solely at the Buyer’s own risk and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. For technical support, please contact IR’s Technical Assistance Center http://www.irf.com/technical-info/ WORLD HEADQUARTERS: 101 N. Sepulveda Blvd., El Segundo, California 90245 Tel: (310) 252-7105 www.irf.com 15 AUIR3317(S) Revision History Revision A B C www.irf.com Date Notes/Changes 10/06/2010 25/08/2011 First release AU release Add test condition to Isdf page 4 16
AUIR3317 价格&库存

很抱歉,暂时无法提供与“AUIR3317”相匹配的价格&库存,您可以联系我们找货

免费人工找货