EMA-MB91F467S-LS-176M07 数据手册
Fujitsu Microelectronics Europe
User Guide
FMEMCU-UG-910070-17
FR60 FAMILY
SOCKET ADAPTER BOARD
EMA-MB91F467S-LS-176M07
USER GUIDE
EMA-MB91F467S-LS-176M07
Revision History
Revision History
Date
20.12.2007
14.01.2008
14.01.2008
15.01.2008
07.04.2008
13.10.2008
16.01.2009
17.03.2009
Issue
V1.0, MB,AW,RH First creation
V1.1, CPLD code and S401_4 default settings changed
V1.2, CPLD code and default settings changed (SDRAM support)
V1.3, Fig. 2.1 changed
V1.4, China RoHS note added, CPLD code formatted, SDRAM removed
V1.5, CEy
Changed Figure 2.1, order of CS select switches interchanged, chapter 3.4
rewritten, some minor corrections and improved descriptions
V1.6, CEy
Description for EMA-MB91FV460B-001 and functional restrictions added
V1.7, CEy
Corrected numbering in chapter 1.3.2 and added hint regarding existing
application note
Latest product revision:
1.1
Latest schematic revision:
1.1
Latest PCB revision:
1.0
Latest CPLD revision:
7S18
This document contains 26 pages.
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
-2-
EMA-MB91F467S-LS-176M07
Warranty and Disclaimer
Warranty and Disclaimer
To the maximum extent permitted by applicable law, Fujitsu Microelectronics Europe GmbH restricts
its warranties and its liability for the EMA-MB91F467S-LS-176M07 Board and all its deliverables
(e.g. software include or header files, application examples, target boards, evaluation boards,
engineering samples of IC’s etc.), its performance and any consequential damages, on the use of the
Product in accordance with (i) the terms of the License Agreement and the Sale and Purchase
Agreement under which agreements the Product has been delivered, (ii) the technical descriptions
and (iii) all accompanying written materials. In addition, to the maximum extent permitted by
applicable law, Fujitsu Microelectronics Europe GmbH disclaims all warranties and liabilities for the
performance of the Product and any consequential damages in cases of unauthorised decompiling
and/or reverse engineering and/or disassembling. Note, the EMA-MB91F467S-LS-176M07 Board
and all its deliverables are intended and must only be used in an evaluation laboratory
environment.
1.
Fujitsu Microelectronics Europe GmbH warrants that the Product will perform substantially in
accordance with the accompanying written materials for a period of 90 days form the date of
receipt by the customer. Concerning the hardware components of the Product, Fujitsu
Microelectronics Europe GmbH warrants that the Product will be free from defects in material
and workmanship under use and service as specified in the accompanying written materials
for a duration of 1 year from the date of receipt by the customer.
2.
Should a Product turn out to be defect, Fujitsu Microelectronics Europe GmbH´s entire liability
and the customer’s exclusive remedy shall be, at Fujitsu Microelectronics Europe GmbH´s
sole discretion, either return of the purchase price and the license fee, or replacement of the
Product or parts thereof, if the Product is returned to Fujitsu Microelectronics Europe GmbH in
original packing and without further defects resulting from the customer’s use or the transport.
However, this warranty is excluded if the defect has resulted from an accident not attributable
to Fujitsu Microelectronics Europe GmbH, or abuse or misapplication attributable to the
customer or any other third party not relating to Fujitsu Microelectronics Europe GmbH.
3.
To the maximum extent permitted by applicable law Fujitsu Microelectronics Europe GmbH
disclaims all other warranties, whether expressed or implied, in particular, but not limited to,
warranties of merchantability and fitness for a particular purpose for which the Product is not
designated.
4.
To the maximum extent permitted by applicable law, Fujitsu Microelectronics Europe GmbH´s
and its supplier’s liability are restricted to intention and gross negligence.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES
To the maximum extent permitted by applicable law, in no event shall Fujitsu
Microelectronics Europe GmbH and its suppliers be liable for any damages whatsoever
(including but without limitation, consequential and/or indirect damages for personal
injury, assets of substantial value, loss of profits, interruption of business operation,
loss of information, or any other monetary or pecuniary loss) arising from the use of
the Product.
Should one of the above stipulations be or become invalid and/or unenforceable, the remaining
stipulations shall stay in full effect
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
-3-
EMA-MB91F467S-LS-176M07
Contents
0 Contents
REVISION HISTORY ............................................................................................................ 2
WARRANTY AND DISCLAIMER ......................................................................................... 3
0 CONTENTS...................................................................................................................... 4
1 OVERVIEW...................................................................................................................... 5
1.1
Abstract................................................................................................................... 5
1.2
General Description................................................................................................. 6
1.3
Functional Restrictions ............................................................................................ 7
2 INSTALLATION ............................................................................................................... 9
3 SWITCHES AND JUMPERS.......................................................................................... 10
3.1
Level Shifter Switches and Jumpers overview....................................................... 10
3.2
Level-shifter direction control jumper ..................................................................... 11
3.3
Bus control jumpers............................................................................................... 12
3.4
Port 17 Jumpers (APIX AIC Link) .......................................................................... 16
3.5
Default Jumper Setting .......................................................................................... 17
4 MECHANICAL DIMENSIONS........................................................................................ 19
5 CPLD ............................................................................................................................. 20
5.1
CPLD Verilog Code ............................................................................................... 20
5.2
CPLD Constraints.................................................................................................. 22
5.3
CPLD programming jumper (J491) ........................................................................ 22
6 INFORMATION IN THE WWW....................................................................................... 23
7 CHINA-ROHS REGULATION ........................................................................................ 24
8 RECYCLING .................................................................................................................. 26
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
-4-
EMA-MB91F467S-LS-176M07
Chapter 1: Overview
1 Overview
1.1
Abstract
The EMA-MB91F467S-LS-176M07 in combination with the EMA-MB91V460A-002B/-80/003
or EMA-MB91FV460B-001 is a development system for the Fujitsu FR60 MB91V460 Flash
microcontroller.
The EMA-MB91F467S-LS-176M07 is an adapter board with level shifters to support the
MB91V460A external bus interface at 3.3V levels.
The development system allows the designer immediately to start with the software
development before MB91V460 based silicon samples are available.
This board must only be used for test applications
in an evaluation laboratory environment.
Before using the EMA-MB91F467S-LS-176M07 adapter board, make sure that the following
packed components have been delivered:
o
1 pcs. EMA-MB91F467S-LS-176M07 socket adapter board
o
1 pcs. YQPACK176SD
o
5 pcs. Screw M2x12
o
5 pcs. Washer M2, Nylon
o
10 pcs. 2mm mini jumper
o
1 pcs. User Guide
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
-5-
EMA-MB91F467S-LS-176M07
Chapter 1: Overview
1.2
General Description
The EMA-MB91F467S-LS-176M07 in combination with the EMA-MB91V460A-002B/-80/003
or EMA-MB91FV460B-001 replaces a MB91F467S microcontroller. For further details of the
EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001 board please refer to the User
Guide of the EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001.
In case EMA-MB91V460A-002B/-80/003 is used, the EMA-MB91V460A-300 extension
board is required for the emulation of the APIX functionality of MB91F467S. Please refer to
the User Guide of the EMA-MB91V460A-300 for further details.
In case of EMA-MB91FV460B-001, it is recommended to use EMA-MB91F460S-176M07 as
socket adapter board.
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
-6-
EMA-MB91F467S-LS-176M07
Chapter 1: Overview
1.3
Functional Restrictions
1.3.1 Valid for EMA-MB91V460A-002B/-80/003
This probe cable can only be used for the following Microcontroller configuration:
1. VDD5 = 5V, VDD35 = 3.3V
The following Microcontroller configurations (2 & 3) are applicable with this probe cable, but
it is recommended to use the appropriate MCU “NLS” probe cable!
2. VDD5 = 5V, VDD35 = 5V
3. VDD5 = 3.3V, VDD35 = 3.3V
While using this probe cable, the GPIO functionality on the external bus interface (VDD35
voltage domain) is restricted!
Unused external bus function pins (e.g. address lines) cannot be configured as general
purpose in- or output randomly!
The following ports can be configured as permanent general purpose input OR output.
1. P07[0..7]
2. P06[0..7]
3. P05[0..7]
It is only possible to configure the whole port as input OR output!
Configuring each pin of these ports separately as input or output is not applicable!
For details on how to configure the port input and output direction please see chapter 3.2
Level-shifter direction control jumper!
The following pins can be configured as permanent general purpose input OR output
separately.
4. P08[0..1], P08_4, P08_7, P09[0..3], P10[0..1], P10_3
It is possible to configure the pins each as input OR output! Configuring each pin of these
ports separately as input or output is applicable by removing certain resistors and making
appropriate DIP-Switch settings!
For details on how to configure the pins input and output direction please see chapter 3.3
Bus control jumpers and the corresponding schematics.
APIX functionality must be emulated via external bus access to extension board EMAMB91V460A-300. Please refer also to chapter “Port 17 Jumpers (APIX AIC Link)” for further
restrictions.
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
-7-
EMA-MB91F467S-LS-176M07
Chapter 1: Overview
1.3.2 Valid for EMA-MB91FV460B-001
This probe cable can only be used for the following Microcontroller configuration:
1. VDD5 = 5V, VDD35 = 3.3V
The following Microcontroller configurations (2 & 3) are applicable with this probe cable, but
it is recommended to use the appropriate MCU “NLS” probe cable!
2. VDD5 = 5V, VDD35 = 5V
3. VDD5 = 3.3V, VDD35 = 3.3V
While using this probe cable, the GPIO functionality on the external bus interface (VDD35
voltage domain) is restricted!
Unused external bus function pins (e.g. address lines) cannot be configured as general
purpose in- or output randomly!
The following ports can be configured as permanent general purpose input OR output.
5. P07[0..7]
6. P06[0..7]
7. P05[0..7]
It is only possible to configure the whole port as input OR output!
Configuring each pin of these ports separately as input or output is not applicable!
For details on how to configure the port input and output direction please see chapter 3.2
Level-shifter direction control jumper!
The following pins can be configured as permanent general purpose input OR output
separately.
8. P08[0..1], P08_4, P08_7, P09[0..3], P10[0..1], P10_3
It is possible to configure the pins each as input OR output! Configuring each pin of these
ports separately as input or output is applicable by removing certain resistors and making
appropriate DIP-Switch settings!
For details on how to configure the pins input and output direction please see chapter 3.3
Bus control jumpers and the corresponding schematics.
The routing of SDINM, SDINP, SDOUTM, SDOUTP to the target board is not possible, so
you have to use the APIX interface on EMA-MB91FV460B-001.
The MCU socket pins 100-103 on your target board will be driven by EMA-MB91FV460B001 with 5V and 1.8V respectively (please see schematic). Check if this is a problem for your
target hardware.
Ensure that J200-J205 are set to position 2-3! Otherwise the related signals will be driven by
EMA-MB91FV460B-001 with various voltages (please see schematic)
Set AVCC1 and AVRH1 jumpers on EMA-MB91FV460B-001 so that VDD5 is selected as
source. Otherwise these inputs would be supplied by your target board VDD1.8
Please refer also to Application Note mcu-an-300100-e-vxx-ema_mb91f467s_ls_176m07_with_ema_mb91fv460_001 for more information about the limitations and
precautions when using EMA-MB91FV460B-001 together with EMA-MB91F467S-LS176M07
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
-8-
EMA-MB91F467S-LS-176M07
Chapter 2: Installation
2 Installation
Remove carefully the EMA-MB91F467S-LS-176M07 board from the shipping carton and
check if there are any damages.
Please refer to the attached document “NQPACK/ YQPACK/ HQPACK Technical
Information” for installation the socket adapter.
Screw
M2.5 x 12
(optional)
DSU4 SSRAM, Emulation bus Flash + SRAM
MB91V460
Washer
M2.5 (Fiber)
(optional)
Connector for extension board
EMA-MB91V460A-002B/-80/003
Connector EMA-MB91V460A-002B/-80/003 to
EMA-MB91V460A-300 or EMA-MB91F467S-LS-176M07
EMA-MB91V460A-300 (optional)
Connector EMA-MB91V460A-002B/-80/003 or
EMA-MB91V460A-300 to EMA-MB91F467S-LS-176M07
EMA-MB91F467S-LS-176M07
YQSOCKET176SDN
120,8 mm
YQPACK176SD
NQPACK / CSPACK
NQPACK176SD
Target board
T
Figure 2-1: Installation
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
-9-
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3 Switches and Jumpers
This chapter describes all switches and jumpers that can be modified or accessed on the
EMA-MB91F467S-LS-176M07 board. The default setting is shown with a grey shaded area.
3.1
Level Shifter Switches and Jumpers overview
Jumper
Description/ Function
Type
Default
S400-1
S400-2
S400-3
S400-4
S400-5
S400-6
S400-7
S400-8
S400-9
S400-10
S401-1
S401-2
S401-3
S401-7
S401-8
S401-9
S400-10
R400
R401
R402
R403
R404
R405
R406
R407
R408
R410
R413
DIR_U406
DIR_U407
DIR_U408
P09_0 CS0#
P09_1 CS1#
P09_2 CS2#
P09_3 CS3#
P10_0 SYSCLK
P10_1 AS#
P10_3 WE#
CS select
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
DIP-Switch
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
P08_7
P08_4
P08_1
P08_0
P09_0
P09_1
P09_2
P09_3
P10_1
P10_3
P08_0
P08_1
P08_4
P08_7
P10_0
RDY
RD#
WR1
WR0#
CS0#
CS1#
CS2#
CS3#
AS#
WE#
WR0#
WR1#
RD#
RDY
SYSCLK
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 10 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.2
Level-shifter direction control jumper
Jumper
Setting
S400-1
(Direction U406)
ON
Target board A[0..7]
MB91V460 A[0..7]
OFF
Target board A[0..7]
MB91V460 A[0..7]
ON
Target board A[8..15]
MB91V460 A[8..15]
OFF
Target board A[8..15]
MB91V460 A[8..15]
ON
Target board A[16..23]
MB91V460 A[16..23]
OFF
Target board A[16..23]
MB91V460 A[16..23]
S400-2
(Direction U407)
S400-3
(Direction U408)
Description
Default: S400-1, S400-2, S400-3: OFF
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 11 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.3
Bus control jumpers
3.3.1 WR0# (P08_0)
R406
S400-10
Description
Closed
OFF
MB91V460 P08_0
Target board WR0#
Open
ON
MB91V460 P08_0
Target board WR0#
Closed
ON
Prohibited
Default: R406: Closed, S400-10: OFF
3.3.2 WR1# (P08_1)
R407
S401-09
Description
Closed
OFF
MB91V460 P08_1
Target board WR1#
Open
ON
MB91V460 P08_1
Target board WR1#
Closed
ON
Prohibited
Default: R407: Closed, S401-09: OFF
3.3.3 RD# (P08_4)
R408
S401-8
Description
Closed
OFF
MB91V460 P08_4
Target board RD#
Open
ON
MB91V460 P08_4
Target board RD#
Closed
ON
Prohibited
Default: R408: Closed, S401-8: OFF
3.3.4 RDY (P08_7)
R410
S401-7
Description
Closed
OFF
MB91V460 P08_7
Target board RDY
Open
ON
MB91V460 P08_7
Target board RDY
Closed
ON
Prohibited
Default: R410: Closed, S401-7: OFF
3.3.5 CS0# (P09_0)
R400
S400-4
Description
Closed
OFF
MB91V460 P09_0
Target board CS0#
Open
ON
MB91V460 P09_0
Target board CS0#
Closed
ON
Prohibited
Default: R400: Closed, S400-4: OFF
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 12 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.3.6 CS1# (P09_1)
R401
S400-5
Description
Closed
OFF
MB91V460 P09_1
Target board CS1#
Open
ON
MB91V460 P09_1
Target board CS1#
Closed
ON
Prohibited
Default: R401: Closed, S400-5: OFF
3.3.7 CS2# (P09_2)
R402
S400-6
Description
Closed
OFF
MB91V460 P09_2
Target board CS2#
Open
ON
MB91V460 P09_2
Target board CS2#
Closed
ON
Prohibited
Default: R402: Closed, S400-6: OFF
3.3.8 CS3# (P09_3)
R403
S400-7
Description
Closed
OFF
MB91V460 P09_3
Target board CS3#
Open
ON
MB91V460 P09_3
Target board CS3#
Closed
ON
Prohibited
Default: R403: Closed, S400-7: OFF
3.3.9 SYSCLK (P10_0)
R413
S400-8
Description
Closed
OFF
MB91V460 P10_0
Target board SYSCLK
Open
ON
MB91V460 P10_0
Target board SYSCLK
Closed
ON
Prohibited
Default: R413: Closed, S400-8: OFF
3.3.10 AS# (P10_1)
R404
S400-9
Description
Closed
OFF
MB91V460 P10_1
Target board AS#
Open
ON
MB91V460 P10_1
Target board AS#
Closed
ON
Prohibited
Default: R404: Closed, S400-9: OFF
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 13 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.3.11 WE# (P10_3)
R405
S400-10
Description
Closed
OFF
MB91V460 P10_3
Target board WE#
Open
ON
MB91V460 P10_3
Target board WE#
Closed
ON
Prohibited
Default: R405: Closed, S400-10: OFF
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 14 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.3.12 CS select (CPLD)
Chip select signals, selected by S401-1..3, will not be routed towards the target hardware!
For applications with extension board EMA-MB91V460A-300 or equivalent extension
boards, please select and set the corresponding chip select signal (CSx) used for the
extension board! Please also refer to the user guide of the extension board and to the
settings on the extension board itself.
E.g. EMA-MB91V460A-300 is configured to use chip select CS3, please set S401-1,2,3 on
EMA-MB91F467S-LS-176M07 to CS3 (ON, ON, OFF)!
In default setting all chip select signals are routed to the target hardware.
S401-1
S401-2
S401-3
OFF
OFF
OFF
CS0# is selected
ON
OFF
OFF
CS1# is selected
OFF
ON
OFF
CS2# is selected
ON
ON
OFF
CS3# is selected
ON
None selected
Don’t care
Description
Default: S401-1, S401-2: OFF, S401-3: ON
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 15 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.4
Port 17 Jumpers (APIX AIC Link)
If EMA-MB91FV460B-001 is used together with EMA-MB91F467S-LS-176M07 set J200J205 to 2-3 and the following mentioned restrictions will not apply!
When using EMA-MB91V460A-002B/-80/003 with the EMA-MB91V460A-300 extension
board for APIX emulation, it is possible to route the signals from the APIX Automotive
Interconnection Link on EMA-MB91V460A-300 to the appropriate pins of the EMAMB91F467S-LS-176M07.
Due to wrong pin connections (P17_7 is used as TCLKI on final MB91F467S instead of
P17_4) only the Use Cases where one of the data bits acts as the clock signal are
supported.
Please note: The APIX Automotive Interconnection Link 0 signals of EMA-MB91V460A-300
are routed to APIX Automotive Interconnection Link 1 of EMA-MB91F467S-LS-176M07
3.4.1 P17 / AIC Link function
Jumper U100 pin
J200
J201
J202
J203
J204
J205
871
86
85
83²
82
81
P 1-2
[AIC Link used]
J801_66 (RCK1)
J801_69 (RDA10)
J801_70 (RDA11)
J801_67 (TCKI1)
J801_68 (TDA10)
J801_65 (TDA11)
P 2-3
[P17 function]
P17_0
P17_1
P17_2
P17_4
P17_5
P17_6
P 3-4
[AIC Link used]
P17_0 pulldown
P17_1 pulldown
P17_2 pulldown
P17_4 pulldown
P17_5 pulldown
P17_6 pulldown
Default: all 2-3
1
Signal available, but corresponding Use Case not supported due to wrong pin assignment of TCLKI1 signal
² TCLKI1 signal available on this pin (P17_4 instead of P17_7)
Please refer also to the User Guide of EMA-MB91V460A-300 for the necessary settings on
that board.
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 16 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
3.5
Default Jumper Setting
The following jumper setting is the default setting.
Figure 3-1: Jumper default setting, top
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 17 -
EMA-MB91F467S-LS-176M07
Chapter 3: Switches and Jumpers
1
10
S400
ON
U100
S401
Figure 3-2: Jumper location, bottom
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 18 -
EMA-MB91F467S-LS-176M07
Chapter 4: Mechanical dimensions
4 Mechanical dimensions
Figure 4-1: Mechanical Dimensions
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 19 -
EMA-MB91F467S-LS-176M07
Chapter 5: CPLD
5 CPLD
The CPLD Xilinx XC9536XL-5VQL44C controls the direction of the data bus.
5.1
CPLD Verilog Code
`timescale 1ns / 1ps
///////////////////////////////////////////////////////////////////////////
// Company:
Accemic GmbH & Co. KG
// Engineer:
RH / AW
//
// Create Date:
05/12/2007
// Design Name:
EMA-MB91F467S-LS-176M07
// Module Name:
F467S
// Project Name:
// Target Devices: XC9536XL-5VQ44
// Tool versions: ISE 9.2
// Description:
//
// Dependencies:
//
// Revision:
// Revision
1.8
// Additional Comments: none
//
// USERCODE:
7S18
//
||||____ Subversion
//
|||_____ Version
//
||______ Target 467S
//
**
//
///////////////////////////////////////////////////////////////////////////
module EMA_MB91F467S_LS_176M07_V11_cpld_7S18(
ECSx,
CSx,
// P09_7..P09_0
WRx,
// P08_3..P08_0
RDx,
// P08_4
ASx,
// P10_1
BAAx,
// P10_2
WEx,
// P10_3
IORDx,
// P11_0
IOWRx,
// P11_1
S401,
DIR_U400,
DIR_U401,
DIR_U404,
DIR_U405,
OEx_U404,
OEx_U405);
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 20 -
EMA-MB91F467S-LS-176M07
Chapter 5: CPLD
input ECSx;
input[7:0] CSx;
input[3:0] WRx;
input RDx;
input ASx;
input BAAx;
input WEx;
input IORDx;
input IOWRx;
input[7:1] S401;
output DIR_U400;
output DIR_U401;
output DIR_U404;
output DIR_U405;
output OEx_U404;
output OEx_U405;
reg OEx_U404, OEx_U405;
reg DIR_U400, DIR_U401, DIR_U404, DIR_U405;
always @*
begin
case (S401[3:1]) //
3'b111:
//
OEx_U404
3'b110:
//
OEx_U404
3'b101:
//
OEx_U404
3'b100:
//
OEx_U404
default:
//
OEx_U404
endcase
CS_MASK
CS0
= !ECSx | (CSx[1]
CS1
= !ECSx | (CSx[0]
CS2
= !ECSx | (CSx[0]
CS3
= !ECSx | (CSx[0]
none masked
= !ECSx | (CSx[0]
& CSx[2] & CSx[3]);
& CSx[2] & CSx[3]);
& CSx[1] & CSx[3]);
& CSx[1] & CSx[2]);
& CSx[1] & CSx[2] & CSx[3]);
OEx_U405 = OEx_U404;
// check
DIR_U400
DIR_U401
DIR_U404
DIR_U405
schematic for DIR level (different on LS boards)
= 1;
= 1;
= !RDx;
= !RDx;
end
endmodule
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 21 -
EMA-MB91F467S-LS-176M07
Chapter 5: CPLD
5.2
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
NET
5.3
CPLD Constraints
"ASx" LOC = "P13" ;
"BAAx" LOC = "P14" ;
"CSx" LOC = "P2" ;
"CSx" LOC = "P1" ;
"CSx" LOC = "P3" ;
"CSx" LOC = "P5" ;
"CSx" LOC = "P6" ;
"CSx" LOC = "P7" ;
"CSx" LOC = "P8" ;
"CSx" LOC = "P12" ;
"DIR_U400" LOC = "P39" |
"DIR_U401" LOC = "P38" |
"DIR_U404" LOC = "P36" |
"DIR_U405" LOC = "P37" |
"ECSx" LOC = "P32" ;
"IORDx" LOC = "P18" ;
"IOWRx" LOC = "P19" ;
"OEx_U404" LOC = "P34" |
"OEx_U405" LOC = "P33" |
"RDx" LOC = "P44" ;
"S401" LOC = "P31" ;
"S401" LOC = "P30" ;
"S401" LOC = "P29" ;
"S401" LOC = "P28" ;
"S401" LOC = "P27" ;
"S401" LOC = "P23" ;
"S401" LOC = "P22" ;
"WEx" LOC = "P16" ;
"WRx" LOC = "P40" ;
"WRx" LOC = "P41" ;
"WRx" LOC = "P43" ;
"WRx" LOC = "P42" ;
SLEW
SLEW
SLEW
SLEW
=
=
=
=
FAST
FAST
FAST
FAST
;
;
;
;
SLEW = FAST ;
SLEW = FAST ;
CPLD programming jumper (J491)
The CPLD is re-configurable by programming via J491. Please refer to www.xilinx.com for
details and tools for Xilinx CPLD configuration.
HTU
J491 pin
Name
1
2
3
4
5
6
GND
TDO
TCK
TMS
TDI
VREF
FMEMCU-UG-910070-17
UTH
© Fujitsu Microelectronics Europe GmbH
- 22 -
EMA-MB91F467S-LS-176M07
Chapter 6: Information in the WWW
6 Information in the WWW
Information about FUJITSU MICROELECTRONICS Products
can be found on the following Internet pages:
Microcontrollers (8-, 16- and 32bit), Graphics Controllers
Datasheets and Hardware Manuals, Support Tools (Hard- and Software)
http://mcu.emea.fujitsu.com/mcu_portal.htm
Linear Products: Power Management, A/D and D/A Converters
http://www.fujitsu.com/emea/services/microelectronics
Media Products: SAW filters, acoustic resonators and VCOs
http://www.fujitsu.com/emea/services/microelectronics/saw
For more information about FUJITUS MICROELECTRONICS
http://www.fujitsu.com/emea/services/microelectronics
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 23 -
EMA-MB91F467S-LS-176M07
Chapter 7: China-RoHS regulation
7 China-RoHS regulation
Evaluation Board
评估板
Emulation Board
仿真板
根据SJ/T113642006《电子信息产品污染控制标识要求》特提供如下有关污染控制方面的信息。
The following product pollution control information is provided according to SJ/T11364-2006
Marking for Control of Pollution caused by Electronic Information Products.
1.电子信息产品污染控制标志说明 Explanation of Pollution Control Label
该标志表明本产品含有超过中国标准SJ/T113632006《电子信息产品中有毒有害物质的限量要求》中限量的有毒有害物质。标志中的数字为
本产品的环保使用期,表明本产品在正常使用的条件下,有毒有害物质不会发生外泄或突变,
用户使用本产品不会对环境造成严重污染或对其人身、财产造成严重损害的期限,单位为年。
为保证所申明的环保使用期限,应按产品手册中所规定的环境条件和方法进行正常使用,并严
格遵守产品维修手册中规定的定期维修和保养要求。
产品中的消耗件和某些零部件可能有其单独的环保使用期限标志,并且其环保使用期限有可能
比整个产品本身的环保使用期限短。应到期按产品维修程序更换那些消耗件和零部件,以保证
所申明的整个产品的环保使用期限。
本产品在使用寿命结束时不可作为普通生活垃圾处理,应被单独收集妥善处理。
请注意:环保使用期限50年的指定不是与产品的耐久力,使用期限或任何担保要求等同的。
This symbol to be added to all EIO sold to China, indicates the product contains hazardous
materials in excess of the limits established by the Chinese standard SJ/T11363-2006
Requirements for Concentration Limits for Certain Hazardous Substances in Electronic
Information Products. The number in the symbol is the Environment-friendly Use Period
(EFUP), which indicates the period, starting from the manufacturing date, during which the
toxic or hazardous substances or elements contained in electronic information products will
not leak or mutate under normal operating conditions so that the use of such electronic
information products will not result in any severe environmental pollution, any bodily injury or
damage to any assets, the unit of the period is “Year”.
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 24 -
EMA-MB91F467S-LS-176M07
Chapter 7: China-RoHS regulation
In order to maintain the declared EFUP, the product shall be operated normally according to
the instructions and environmental conditions as defined in the product manual, and periodic
maintenance schedules specified in Product Maintenance Procedures shall be followed
strictly.
Consumables or certain parts may have their own label with an EFUP value less than the
product. Periodic replacement of those consumables or parts to maintain the declared EFUP
shall be done in accordance with the Product Maintenance Procedures.
This product must not be disposed of as unsorted municipal waste, and must be collected
separately and handled properly after decommissioning.
Please note: The designation of 10 years EFUP is not to be equated with the durability, useduration or any warranty-claims of the product.
产品中有毒有害物质或元素的名称及含量
Table of hazardous substances name and concentration
有毒有害物质或元素
部件名称
EMA-MB91F467S-LS176M07
Hazardous substances name
铅
汞
镉
六价铬
多溴联苯
多溴二苯醚
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
(PBDE)
x
o
o
o
o
o
O: 表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006 标准规定的限量要求以下
X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006 标准规定的限量要求
•
此表所列数据为发布时所能获得的最佳信息
•
由于缺少经济上或技术上合理可行的替代物质或方案,此医疗设备运用以上一些有毒有害物质来实现设备的预期
临床功能,或给人员或环境提供更好的保护效果。
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous
materials for this part is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the
homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006.
•
Data listed in the table represents best information available at the time of publication
© Fujitsu Microelectronics Europe GmbH
FMEMCU-UG-910070-17
- 25 -
EMA-MB91F467S-LS-176M07
Chapter 8: Recycling
8 Recycling
Gültig für EU-Länder:
Gemäß der Europäischen WEEE-Richtlinie und deren Umsetzung in landesspezifische
Gesetze nehmen wir dieses Gerät wieder zurück.
Zur Entsorgung schicken Sie das Gerät bitte an die folgende Adresse:
Fujitsu Microelectronics Europe GmbH
Warehouse
Monzastraße 4a
63225 Langen
Valid for European Union Countries:
According to the European WEEE-Directive and its implementation into national laws we
take this device back.
For disposal please send the device to the following address:
Fujitsu Microelectronics Europe GmbH
Warehouse
Monzastraße 4a
63225 Langen
FMEMCU-UG-910070-17
© Fujitsu Microelectronics Europe GmbH
- 26 -