Product Brief
TLF35584
System-Supply for Safety-Relevant Applications
The TLF35584 is a multiple output system-supply for safety-relevant applications
supplying 5 V or 3.3 V µC, transceivers, and sensors by an efficient and flexible pre-/
post-regulator concept over a wide input voltage range. The wide switching frequency
range allows optimization in respect of efficiency and usage of small filter components. A
dedicated reference-regulator supplies the ADC independent from µC-load steps and acts
as tracking-source for the 2 independent sensor-supplies. The flexible state
machine, wake-up concept including timer, and the stand-by-regulator favors the usage
in numerous applications.
Multiple safety features enable easy realization of ASIL-D together with various µCs. The
TLF35584 is coming in small VQFN-48 (QV-version) capable for automated optical inspection and additionally in LQFP-64 (QK-version), both packages thermally enhanced.
Functional Block Diagram
Key Features
Pre-/post-regulator concept:
boost & buck / LDOs & trackers for
–– µC (main, ADC/reference, StBy)
–– Transceivers
–– Sensors
Integration of functional safety
(features supporting ASIL-D)
–– UV/OV-monitoring
–– Flexible watchdogs
–– Error-monitoring
–– Safe state controller with
2 outputs
–– BIST
Power Management
Pre-Regulator
Post-Regulator
Synchronous Buck
Optional Asynchronous Boost
µC-Supply
Communication-Supply
Sensor-Supply
Voltage-Reference
Control & Monitoring of
external Core-Supply
Enable & Wake/INH, Timer
Standby-Supply
State Machine
Internal Supply, Bandgap, Clock
Window-Watchdog
Functional-Watchdog
Voltage Monitoring
Interrupt-/Reset-Generator
Error Monitoring
Built In Self Test
Electrical Isolation, Bandgap
µC-Interface
SPI
www.infineon.com
Efficiency and flexibility
Enables ASIL-D on system level
Wide temperature range
Applications
Functional Safety
Safe State Controller
Key Benefits
Safety: EPS, braking, suspension,
chassis-controller, ADAS-fusion-box
Powertrain: EMS, transmission
EDT: inverter, BMS, DC/DC, charger
Product Brief
TLF35584
System-Supply for Safety-Relevant Applications
Application Diagram
System Supply TLF35584
UV-/OV-/Error-Monitoring
Window- & Q/A-Watchdog
Safety
Path
Safe State Controller
Vbatt
Boost/Buck
Pre-Reg
LDO1)
StdBy
LDO
µC
LDO
Ref
LDO
µC
2)
SMPR
Tracker 1
Tracker 2
Com
LDO
Sensors
CAN
Sensors
FlexRay
Tracker
1) LDO: Low-Dropout Linear Regulator
2) SMPR: Switch-Mode Post-Regulator
Functional Safety
The device is developed acc. ISO 26262. The applied processes,
safety assessment, and provided documentation (Safety Manual,
Safety Analysis Summary Report) are reducing efforts and time for
the safety assessment on ECU-level.
Required safety integrity functions for ASIL-D are already implemented: UV/OV-monitoring of all rails with independent reference,
detecting dependent failures by flexible watchdog-concept, monitoring of µC’s safety management unit, and a safe state controller
providing secondary safety paths. A built-in-self-test is ensuring
the proper function of the relevant safety features. All features are
perfectly aligned to the Infineon’s AURIX™-requirements, but are
extended to support other µCs as well.
All safety-relevant configurations are protected and can only
be changed by special, successfully performed unlock/lock-sequence.
Product Summary
Type
Description
Ordering Code
TLF35584QV VS1/VS2
PG-VQFN-48; 5 V/3.3 V for µC-supply
SP001096170/SP001096172
TLF35584QK VS1/VS2
PG-LQFP-64; 5 V/3.3 V for µC-supply
SP001273504/SP001273506
Published by
Infineon Technologies AG
85579 Neubiberg, Germany
© 2015 Infineon Technologies AG.
All Rights Reserved.
Visit us:
www.infineon.com
Please note!
THIS DOCUMENT IS FOR INFORMATION PURPOSES ONLY
AND ANY INFORMATION GIVEN HEREIN SHALL IN NO EVENT
BE REGARDED AS A WARRANTY, GUARANTEE OR DESCRIPTION
OF ANY FUNCTIONALITY, CONDITIONS AND/OR QUALITY OF
OUR PRODUCTS OR ANY SUITABILITY FOR A PARTICULAR
PURPOSE. WITH REGARD TO THE TECHNICAL SPECIFICATIONS OF OUR PRODUCTS, WE KINDLY ASK YOU TO REFER
TO THE RELEVANT PRODUCT DATA SHEETS PROVIDED BY
US. OUR CUSTOMERS AND THEIR TECHNICAL DEPARTMENTS
ARE REQUIRED TO EVALUATE THE SUITABILITY OF OUR
PRODUCTS FOR THE INTENDED APPLICATION.
WE RESERVE THE RIGHT TO CHANGE THIS DOCUMENT AND/
OR THE INFORMATION GIVEN HEREIN AT ANY TIME.
Order Number: B124-I0110-V1-7600-EU-EC
Date: 03 / 2015
Additional information
For further information on technologies, our products,
the application of our products, delivery terms and
conditions and/or prices please contact your nearest
Infineon Technologies office (www.infineon.com).
Warnings
Due to technical requirements, our products may contain
dangerous substances. For information on the types in question please contact your nearest Infineon Technologies office.
Except as otherwise explicitly approved by us in a written
document signed by authorized representatives of Infineon
Technologies, our products may not be used in any life
endangering applications, including but not limited to
medical, nuclear, military, life critical or any other applications where a failure of the product or any consequences of
the use thereof can result in personal injury.
很抱歉,暂时无法提供与“TLF35584QVVS1”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+28.84680
- 10+24.99120
- 30+22.69080
- 国内价格
- 1+15.30860
- 10+14.13100
- 100+12.95340
- 1000+11.77580