Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Block Diagram
Pin Configuration
1. OUT
2. GND
3. VCC
Features
‧High protection ability against EMI
‧Circular lens for improved reception characteristics
‧ Available for various carrier frequencies
‧ min burst length (36/38 kHz): 8 cycles
‧ min burst length (56 kHz): 10 cycles
‧ min gap length (36/38 kHz): 12 cycles
‧ min gap length (56 kHz): 14 cycles
‧ Low operating voltage and low power consumption
‧ High immunity against ambient light
‧ High immunity against TFT and PDP backlight
‧ Long reception range
‧ High sensitivity
‧ Pb free and RoHS compliant
Description
The IRM-36xxM3F99-E8O(HFX) devices are DIP type
infrared receivers which have been developed and designed by
using the latest IC technology.
The PIN diode and preamplifier are assembled onto a lead
frame and molded into a black epoxy package which operates
as an IR filter.
The demodulated output signal can directly be decoded by a
microprocessor.
Revision
:2
1 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date :2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Applications
• AV equipment such as TV, VCR, DVD, CD, MD, etc.
• CATV set top boxes
• Multi-media Equipment
• Other devices using IR remote control
Application Circuit
The RC Filter must be connected as close as possible to Vcc and GND pins.
Parts Table
Revision
:2
2 Copyright
©
LifecyclePhase:
Model No.
Carrier Frequency
IRM-3638M3F99-E8O(HFX)
38 kHz
IRM-3656M3F99-E8O(HFX)
56 kHz
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Absolute Maximum Ratings (Ta=25°C)
Parameter
Symbol
Rating
Unit
Supply Voltage
Vcc
6
V
Operating Temperature
Topr
-20 ~ +80
℃
Storage Temperature
Tstg
-40 ~ +85
℃
Tsol
260
℃
Soldering Temperature
*1
*1
4mm from mold body for less than 5 seconds
Electro-Optical Characteristics (Ta=25℃, Vcc=3V)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Condition
Current consumption
Icc
---
0.4
0.6
mA
No input signal
Supply voltage
VCC
2.7
-
5.5
V
λp
---
940
---
nm
L0
14
---
---
m
L45
6
---
---
m
Half angle(horizontal)
φh
---
±35
---
deg
Half angle(vertical)
φv
---
±35
---
deg
High level pulse width
TH
450
---
750
μs
Low level pulse width
TL
450
---
750
μs
High level output voltage
VOH
Vcc-0.4
---
---
V
Low level output voltage
VOL
---
0.2
0.5
V
Internal pull up resistor
RPU
34
40
46
kΩ
Peak wavelength
Reception range
Revision
:2
3 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
See chapter
‚Test method’
Test signal
according to
figure 1
ISINK≦2mA
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Test method
The specified electro-optical characteristics are valid under the following conditions.
1. Measurement environment
A place without extreme light reflections.
2. External light
The environment contains an ordinary, white fluorescent lamp without high frequency modulation. The color temperature
is 2856K and the illumination at the IR receiver is less than 10 Lux (Ev≦ 10Lux).
3. Standard transmitter
The test transmitter is calibrated by using the circuit shown in figure 2. The radiation intensity of the transmitter is
adjusted until Vo=400mVp-p. Both, the test transmitter and the photo diode, have a peak wavelength of 940nm. The
photo diode for calibration is PD438B (λp=940nm, Vr=5V).
4. The measurement system is shown in Fig.-3
Fig.-1 Transmitter Wave Form
Fig.-2 standard transmitter calibration
Revision
:2
4 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
D.U.T output Pulse
Fig.-3
Measuring System
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Typical Electro-Optical Characteristic Curves
Revision
:2
5 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Package Dimensions
(Dimensions in mm)
Notes:
Tolerance unless otherwise mentioned ±0.3mm
Revision
:2
6 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
Code information
Protocol
Suitable
Protocol
Suitable
JVC
Yes
RCA
No
Matsushita
Yes
r-step
Yes
Mitsubishi
No
Sharp
Yes
NEC
Yes
Sony 12 bit
Yes
Panasonic
Yes
Sony 15 bit
No
RC5
Yes
Sony 20 bit
No
RC6
Yes
Toshiba
Yes
RCMM
No
XMP-1
Yes
RCS-80
No
Continuous Code
No
Device Marking
Notes
1 denotes Year code
2 denotes Month code
3 denotes Device number
4 denotes Carrier frequency
5 denotes Leadframe type
Packing Quantity
1500 pcs / Box
10 Boxes / Carton
Revision
:2
7 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
DATASHEET
Infrared Receiver Module
IRM-36XXM3F99-E8O(HFX) Series
DISCLAIMER
1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above
specification.
2. The graphs shown in this datasheet are representing typical data only and do not show guaranteed values.
3. When using this product, please observe the absolute maximum ratings and the instructions for use outlined in these
specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which
does not comply with the absolute maximum ratings and the instructions included in these specification sheets.
4. These specification sheets include materials protected under copyright of EVERLIGHT. Reproduction in any form is
prohibited without the specific consent of EVERLIGHT.
5. This product is not intended to be used for military, aircraft, automotive, medical, life sustaining or life saving
applications or any other application which can result in human injury or death. Please contact authorized Everlight
sales agent for special application request.
Revision
:2
8 Copyright
©
LifecyclePhase:
2010, Everlight All Rights Reserved. Release Date : 2014/12/2
Release Date:2014-12-08 20:23:45.0
Issue No:DMO-0000412 Rev.2
www.everlight.com
Expired Period: Forever
很抱歉,暂时无法提供与“IRM-3638M3F99-E80”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+1.15600
- 30+1.11350
- 100+1.07100
- 500+0.98600
- 1000+0.94350
- 2000+0.91800