Appliance Tester/Power Analyzer
Compact, battery operated device for analyzing AC power loads
With PC interface plus datalogging
Features:
• Four simultaneous displays of Watts, Power Factor or VA, Voltage or Hz, Amps • True RMS Voltage & Current measurements of sine, square, triangular and distorted wave forms with a crest factor < 5 • Max, Data Hold and Overload Protection • Battery or AC adaptor provides line isolation • Plug device to be tested directly into the Power Analyzer • Sampling (update) rate is 2.5 times/second • Windows® 95/98/NT/2000/XP/ME software allows user to download stored data or save data directly, and to create an ASCII file. Computations include phase angle, apparent and reactive power, consumption and cost, and power factor correction • Complete with Windows compatible software, cable, 8 x AA batteries, power cord, 117 VAC adaptor and case
Applications:
• Measure and Audit power consumption of single phase devices • Evaluate load performance under varying line conditions • Demonstrate effectiveness of power conservation efforts • Characterize device AC power requirements
Optional Thermal Printer (PR20) prints text or graphics with fixed intervals or continuous
Specifications: Watt Power Factor Voltage Current
Frequency Dimensions/Weight
Software included to download and store data to a PC
Built-into heavy duty carrying case.
Model 380803 Datalogger
• Built-in Datalogger stores up to 1,012 readings (Single record storage or continuous datalogging)
Model 380801
• Used for data acquisition when connected to a PC
Range Resolution Basic Accuracy (%rdg) 200/2000W 0.1/1W ±(0.9% + 4d)@50/60Hz 0.5 to 1.0 0.001 (Based on W, V, A) 200.0/750V 0.1/1V ±(0.5%) 2/20A via terminals ±(0.5%) 2/15A via sockets 40Hz to 20kHz 1Hz to 10Hz ±(0.5%) 13.9 x 11.8 x 3.9" (352 x 300 x 100mm) / 3.6 lbs. (1.6 kg)
Input Signal Range 300V, 20A, 40-400Hz 250V, 20A, 50/60Hz 750VAC (Fuse Protection)
Ordering Information:
380801 ..............True RMS Single Phase Power Analyzer 380801-NIST ......380801 with NIST Certificate 380803 ..............True RMS Power Analyzer Datalogger 380803-NIST ......380803 with NIST Certificate PR20 ..................Portable Thermal Printer 757057 ..............Thermal Paper for PR20 (6 pack) USB100 ..............RS-232 to USB Adaptor
www.extech.com
Specifications subject to change without notice. 8/13/08 - R1 Copyright © 2007-2008 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.