MP510

MP510

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    MP510 - MultiPro Digital MultiMeter Series With PC Interface - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
MP510 数据手册
User’s Guide MultiPro™ Digital MultiMeter Series With PC Interface Models: MP510 MP520 MP530 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. 1 REPAIR AND CALIBRATION SERVICES Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to insure calibration integrity. Support Hotline (781) 890-7440 Tech support: Ext. 200; Email: support@extech.com Repair/Returns: Ext. 210; Email: repair@extech.com Website: www.extech.com Copyright © 2002 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. MP Series V2.2 9/03 P/N: 7M1C-0241-A000 Introduction 2 Congratulations on your purchase of Extech model MP510, MP520, or MP530 digital multimeter. Properly used, this meter will provide many years of reliable service. MultiPro™ Meters measure AC/DC Voltage, AC/DC Current, Resistance, Frequency, Capacitance, Diode, and Continuity. The MultiPro™ also offers RS-232 PC Interface data acquisition capabilities as an option. Models MP520 and MP530 are True RMS AC sensing. In addition, the MP530 offers Temperature, Relative, Peak capture and MIN/MAX functions. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter. 2. Make sure any covers or battery doors are properly closed and secured. 3. Always remove the test leads before replacing the battery or fuses. 4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. 5. Do not exceed the maximum rated input limits. 6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 7. Always discharge capacitors and remove power from the device under test before performing Capacitance, Diode, Resistance or Continuity tests. 8. Remove the battery from the meter if the meter is to be stored for long periods. 9. To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 500V AC. 10. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the electrical contacts. Other means should be used to ensure that the terminals are not "live". 11. The product is intended only for indoor use 12. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 13. Pollution degree: 2 PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient overvoltages to an appropriate low level. Note – Examples include protected electronic circuits. OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation. Note – Examples include household, office, and laboratory appliances. OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note – Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note – Examples include electricity meters and primary over-current protection equipment 3 Specifications 4 DC VOLTAGE RANGE Accuracy 50.00 mV 0.12% + 2d 500.0 mV 0.06% + 2d 5.000V, 50.00V, 500.0V, 1000V 0.08% + 2d NMRR: >60dB @ 50/60Hz, CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ Input impedance: 10MΩ, 16pF nominal (44pF nominal for 50mV & 500mV ranges) AC VOLTAGE RANGE Accuracy 50Hz/60Hz 50.00mV, 500.0mV, 5.000V, 50.00V, 500.0V, 1000V 0.5% + 3d 40Hz to 500Hz 50.00mV, 500.0mV 0.8% + 3d 5.000V, 50.00V, 500.0V 1.0% + 4d 1000V 1.2% + 4d Up to 20kHz 50.00mV, 500.0mV 0.5dB* 5.000V, 50.00V, 500.0V 3dB* 1000V Unspecified *Specified from 30% to 100% of range CMRR: >60dB @ DC to 60Hz, Rs=1kΩ Input Impedance: 10MΩ, 16pF nominal (44pF nominal for 50mV & 500mV ranges) DC CURRENT RANGE Accuracy Burden Voltage 500.0µA, 5000µA 0.15mV/µA 0.2% + 4d 50.00mA, 500.0mA 3.3mV/mA 5.000A, 10.00A* 0.03V/A *10A continuous, 20A for 30 seconds max with a 5 minute cool down interval AC CURRENT RANGE Accuracy Burden Voltage 50 / 60Hz 0.6%+3d 500.0µA, 5000µA 0.15mV/µA 50.00mA, 500.0mA 0.6%+3d 3.3mV/mA 5.000A, 10.00A* 0.6%+3d 0.03V/A 40Hz to 1kHz 0.8%+4d 500.0µA, 5000µA 0.15mV/µA 50.00mA 0.8%+4d 3.3mV/mA 500.0mA 1.0%+4d 3.3mV/mA 5.000A, 10.00A* 0.8%+4d 0.03V/A *10A continuous, 20A for 30-second max with 5 minutes cool down interval Peak Capture (for V & A) Specified accuracy ±150 digits for changes > 5 ms in duration TEMPERATURE (MP530 ONLY) RANGE Accuracy 0.3% + 3d -50°C TO 1000°C 0.3% + 6d -58°F TO 1832°F RESISTANCE RANGE Accuracy 0.2% + 6d 50.00Ω 0.1% + 3d 500.0Ω 0.1% + 2d 5.000kΩ, 50.00kΩ, 500.0kΩ 0.4% + 3d 5.000MΩ 1.5% + 5d 50.00MΩ Open Circuit Voltage: < 1.3VDC (< 3VDC for 50Ω & 500Ω ranges) CAPACITANCE RANGE Accuracy* 50.00nF, 500.0nF 0.8% + 3d 1.0% + 3d 5.000µF 2.0% + 3d 50.00µF 3.5% + 5d 500.0µF 5.0% + 5d 9999µF *Accuracies with film capacitor or better 5 FREQUENCY Function 6 mV 10Hz - 125kHz 5V 10Hz - 125kHz 50V 10Hz - 20kHz 500V 10Hz - 1kHz 1000V 10Hz - 1kHz 10Hz - 125kHz Ω, Cx, diode 10Hz - 125kHz µA, mA, A Accuracy: 0.01% + 2d Audible Continuity: Measurement threshold: Beeper will sound if measurement is below 20Ω. Beeper will not sound if measurement is above 200Ω. Beeper may or may not sound if measurement is between 20 and 200Ω. Response time: < 100µs Accuracy Notes: Accuracy is ± (% reading digits + number of digits), or as otherwise specified, at 23°C ±5°C < 75% R.H. True RMS accuracies are specified from 5% to 100% of range or as otherwise specified. Maximum Crest Factor
MP510 价格&库存

很抱歉,暂时无法提供与“MP510”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DMP510DL-7
  •  国内价格
  • 10+0.2051
  • 50+0.18854
  • 200+0.17474
  • 600+0.16094
  • 1500+0.1499
  • 3000+0.143

库存:43605