GTLP16T1655 16-Bit LVTTL/GTLP Universal Bus Transceiver
August 1998 Revised April 2000
GTLP16T1655 16-Bit LVTTL/GTLP Universal Bus Transceiver
General Description
The GTLP16T1655 is a 16-bit universal bus transceiver that provides LVTTL to GTLP signal level translation. It allows for transparent, latched and clocked modes of data transfer. The device provides a high speed interface between cards operating at LVTTL logic levels and a backplane operating at GTLP logic levels. High speed backplane operation is a direct result of GTLP’s reduced output swing ( VCC ESD Rating Storage Temperature (TSTG) −50 mA +50 mA >2000V −65°C to +150°C −50 mA 200 mA −48 mA 48 mA −0.5V to +4.6V −0.5V to + 4.6V −0.5V to +4.6V −0.5V to +4.6V
Recommended Operating Conditions
Supply Voltage VCC Bus Termination Voltage (VTT) GTLP GTL VREF GTLP GTL Input Voltage (VI) on A Port and Control Pins on B Port HIGH Level Output Current (IOH) A Port LOW Level Output Current (IOL) A Port B Port Operating Temperature (TA) +24mA +100 mA −40°C to +85°C −24 mA 0.0V to VCC 0.0V to Vtt 0.87V to 1.1V 0.74V to 0.87V 1.35V to 1.65V 1.14V to 1.26V 3.0V to 3.6V
Note 4: The Absolute Maximum Ratings are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum rating. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Note 5: IO Absolute Maximum Rating must be observed. Note 6: VTT and Rterm can be adjusted to accommodate backplane impedances other than 50Ω, within the boundaries of not exceeding the DC Absolute IOL ratings (200 mA). Similarly VREF can be adjusted to compensate for changes in VTT.
www.fairchildsemi.com
4
GTLP16T1655
DC Electrical Characteristics
Over Recommended Operating Free-Air Temperature Range, VREF = 1.0V (unless otherwise noted). Symbol VIH VIL VREF VIK VOH A Port B Port Others B Port Others GTLP VCC = 3.0V VCC = Min to Max (Note 8) VCC = 3.0V VOL A Port VCC = Min to Max (Note 8) VCC = 3.0V B Port VCC = 3.0V II = −18 mA IOH = −100 µA IOH = −12 mA IOH = −24 mA IOL = 100 µA IOL = 12 mA IOL = 24 mA IOL = 40 mA IOL = 80 mA IOL = 100 mA II A Port B Port IOFF II(hold) Except VERC A Port VCC = 3.0V VCC = 3.6V IOZH IOZL IOZPU (Note 9) IOZPD (Note 9) ICC (vcc) ∆ICC (Note 10) Ci A Port and A Port A Port B Port A Port B Port A Port VCC = 0 to 1.5V OE = 0 or VCC VCC = 1.5 to 0V OE = 0 or VCC A or B Ports VCC = 3.6 IO = 0 VI = V CC or GND VCC = 3.6V Inputs at VCC or GND Control Pins A Port B Port
Note 7: All typical values are at VCC = 3.3V, and TA = 25°C. Note 8: For conditions shown as Min or Max, use the appropriate value specified under recommended operating conditions. Note 9: This is specified by characterization but not tested. Note 10: This is the increase in supply current for each input that is at the specified TTL voltage level rather than VCC or GND.
Test Conditions
Min VREF +0.05 2.0 0.0 0.74 VCC −0.2 2.4 2.2
Typ (Note 7)
Max VTT VREF −0.05 0.8
Units V V V V V V V
1.0
1.1 −1.2
0.20 0.40 0.50 0.20 0.40 0.50 ±10 ±10 ±10 100 75 −75 ±500 10 10 −10 −10 ±50 ±50 55 55 55 0 1 mA 5.8 8.0 8.3 7.0 9.5 9.9 pF mA µA µA µA µA µA µA µA µA µA V V
VCC = 3.6V VCC = 3.6V VCC = 0
VI = VCC or 0V VI = VCC or 0V VI = VTT or GND VI or VO = 0 to VCC VI = 0.8V VI = 2.0V VI = 0 to VCC VO = V CC VO = 1.5V VO = 0V VO = 0.4V VO = 0.5 to 3V VO = 0.5 to 3V Outputs HIGH Outputs LOW Outputs Disabled One Input at VCC–0.6 VI = VCC or 0 VI = VCC or 0 VI = VCC or 0
Control Pins VCC = 3.6V
VCC = 3.6V VCC = 3.6V
Control Pins A or Control
5
www.fairchildsemi.com
GTLP16T1655
Live Insertion Characteristics
Over Recommended Operating Free-Air Temperature Range, VREF = 1.0V (unless otherwise noted). Parameter ICC (VCCBIAS) VO IO B Port B Port B Port VCC = 0 to 3V VCC = 3.0 to 3.6V VCC = 0 VCC = 0 VI (VCCBIAS) = 3.3v VI (VCCBIAS) = 3 to 3.6V OE = 3.3V OE = 0 to 3.3V VO = 0.4 −1 100 100 µA Test Conditions VO = 0 to 1.2V VI (VCCBIAS) = 3 to 3.6V 1.1 Min Typ Max 5 10 Units mA µA V
VCC = 0 to 3.6V VCC = 0 to 1.5V
AC Operating Requirements (GTLP)
Over recommended ranges of supply voltage and operating free-air temperature, VTT = 1.5V and Vref = 1.0V (unless otherwise noted). Parameter fCLOCK tWIDTH Max Clock Frequency Pulse Duration LE HIGH CLK HIGH or LOW tSU Setup Time Data before CLK↑ Data before LE↓ (CLK = X) tHOLD Hold Time Data after CLK↑ Data after LE↓ (CLK = X) Min 0 3.0 ns 3.0 2.5 ns 2.5 0.5 ns 0.5 Max 160 Unit MHz
B to A
AC Electrical Characteristics (GTLP)
From (Input) To (Output) Typ (Note 11)
Over recommended range of supply voltage and operating free-air temperature, VREF = 1.0V, VTT = 1.5V, VERC =VCC or GND (unless otherwise noted). CL = 30 pF for B-Port and CL = 50 pF for A-Port. Parameter fMAX tPLH tPHL tPLH tPHL tPLH tPHL tPLZ/HZ tPZH/ZL tPLZ/HZ tPZH/ZL
Note 11: All typical values are at VCC = 3.3V, and TA = 25°C.
Min 160
Max
Unit MHz
B
A
1.0 1.5
4.7 ns 4.8 4.0 ns 3.8 4.0 ns 4.0 4.5 ns 4.0 4.9 ns 4.0
LEAB
A
1.2 1.2
CLK
A
1.2 1.2
OE
A
1.4 1.0
OEBA
A
1.2 1.0
www.fairchildsemi.com
6
GTLP16T1655
A to B
AC Electrical Characteristics (GTLP)
From (Input) To (Output) Type (Note 12)
Over recommended range of supply voltage and operating free air temperature, V = 1.0V, VTT = 1.5V (unless otherwise noted). CL = 30 pF for B-Port and CL = 50 pF for A-Port. Symbol fMAX tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tFALL/RISE VERC = VCC tFALL/RISE VERC = GND A VERC = VCC A VERC = GND LEAB VERC = VCC LEAB VERC = GND CLK VERC = VCC CLK VERC = GND OE VERC = VCC OE VERC = GND OEAB VERC = VCC OEAB VERC = GND Transition Time, B outputs (0.6V to 1.3V) Transition Time, B outputs (0.6V to 1.3V) B B B B B B B B B B Min 160 2.6 0.8 2.0 0.7 2.6 0.8 2.2 0.7 2.8 1.0 2.3 0.8 2.7 0.6 2.1 1.0 2.6 0.6 2.0 0.6 0.7/0.7 0.7/0.7 2.0/2.5 1.5/2.0 5.7 ns 4.5 4.9 ns 4.0 5.7 ns 4.0 4.9 ns 4.0 5.7 ns 4.0 5.0 ns 4.0 5.8 ns 4.0 4.9 ns 4.0 5.8 ns 4.0 4.9 ns 3.5 ns ns Max Units MHz
Note 12: All Typical values are at VCC = 3.3V and TA = 25°C
7
www.fairchildsemi.com
GTLP16T1655
Extended Electrical Characteristics (GTLP)
Over recommended ranges of supply voltage and operating free-air temperature VREF = 1.0V (unless otherwise noted). CL = 30 pF for B Port and CL = 50 pF for A Port. Symbol tOSLH (Note 14) tOSHL (Note 14) tPV(HL) (Note 15) (Note 16) tOSLH (Note 14) tOSHL (Note 14) tPV(HL) (Note 15) (Note 16) tOSLH (Note 14) tOSHL (Note 14) tOST (Note 14) tPV (Note 15) tOSLH (Note 14) tOSHL (Note 14) tOST (Note 14) tPV (Note 15) CLKAB CLKAB A A B B CLKAB A A A 0.3 0.3 0.5 CLKAB B B A 0.3 0.3 0.6 A CLKAB B B 0.3 0.3 From (Input) A To (Output) B Min Typ (Note 13) 0.4 0.4 Max 1.0 1.0 1.5 0.9 0.6 1.2 1.0 1.0 1.5 1.6 0.6 0.6 1.0 1.1 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns
Note 13: All typical values are at VCC = 3.3V, and TA = 25°C. Note 14: tOSHL/tOSLH and tOST—Output to output skew is defined as the absolute value of the difference between the actual propagation delay for all outputs within the same packaged device. The specifications are given for specific worst case VCC and temperature and apply to any outputs switching in the same direction either HIGH-to-LOW (tOSHL) or LOW-to-HIGH (tOSLH) or in opposite directions both HL and LH (tOST). This parameter is guaranteed by design and statistical process distribution. Actual skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the device. Note 15: tPV—Part to part skew is defined as the absolute value of the difference between the actual propagation delay for all outputs from device to device. The parameter is specified for a specific worst case VCC and temperature. This parameter is guaranteed by design and statistical process distribution. Actual skew values between the GTLP outputs could vary on the backplane due to the loading and impedance seen by the device. Note 16: Due to the open drain structure on GTLP outputs, tOST and tPV(LH) in the A-to-B direction are not specified. Skew on these paths is dependent on the VTT and RT values on the backplane.
www.fairchildsemi.com
8
GTLP16T1655
AC Operating Requirements (GTL)
Over recommended ranges of supply voltage and operating free-air temperature, VTT = 1.2V and Vref = 0.8V (unless otherwise noted). Parameter fCLOCK tWIDTH tSU tHOLD Max Clock Frequency Pulse Duration Setup Time Hold Time LE HIGH CLK HIGH or LOW Data before CLK↑ Data before LE↓ (CLK = X) Data after CLK↑ Data after LE↓ (CLK =X) Min 0 3.0 3.0 2.5 2.5 0.5 0.5 Max 160 Units MHz ns ns ns ns
B to A
AC Electrical Characteristics (GTL)
From (Input) To (Output) Typ (Note 17)
Over recommended range of supply voltage and operating free air temperature, Vref = 0.8V, VTT = 1.2V, VERC = VCC or GND (unless otherwise noted). CL = 30pF for B Port and CL = 50 pF for A Port. Parameter fMAX tPLH tPHL tPLH tPHL tPLH tPHL tPLZ/HZ tPZH/ZL tPLZ/HZ tPZH/ZL
Note 17: All Typical values are at VCC = 3.3V and TA = 25°C.
Min 160
Max
Units MHz
B
A
1.0 1.2
4.7 ns 4.8 4.4 ns 4.0 4.2 ns 4.1 4.6 ns 4.2 4.9 ns 4.0
LEBA
A
1.0 1.1
CLK
A
1.0 1.1
OE
A
1.5 1.2
OEBA
A
1.2 1.0
9
www.fairchildsemi.com
GTLP16T1655
A to B
AC Electrical Characteristics (GTL)
From (Input) To (Output) Typ (Note 18)
Over recommended range of supply voltage and operating free air temperature, VREF = 0.8V, VTT = 1.2V (unless otherwise noted). CL = 30 pF for B Port and CL = 50 pF for A Port. Symbol fMAX tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tFALL/RISE VERC = VCC tFALL/RISE VERC = VCC A VERC = VCC A VERC = GND LEAB VERC = VCC LEAB VERC = GND CLK VERC = VCC CLK VERC = GND OE VERC = VCC OE VERC = GND OEAB VERC = VCC OEAB VERC = GND Transition Time, B outputs (0.6V to 1.3V) Transition Time, B outputs (0.6V to 1.3V) B B B B B B B B B B Min 160 2.2 1.0 1.5 0.9 2.2 1.0 1.7 0.9 2.8 1.0 2.3 1.0 2.5 0.8 1.7 0.9 2.2 0.8 1.7 0.9 0.7/0.7 0.7/0.7 2.0/2.5 1.5/2.0 5.7 ns 4.7 4.8 ns 4.0 5.7 ns 4.1 5.0 ns 4.4 5.8 ns 4.3 5.0 ns 4.3 5.8 ns 4.3 4.9 ns 4.3 5.8 ns 4.3 4.9 ns 3.8 ns ns Max Units MHz
Note 18: All Typical values are at VCC = 3.3V and TA = 25°C.
www.fairchildsemi.com
10
GTLP16T1655
Extended Electrical Characteristics (GTL)
Over recommended ranges of supply voltage and operating free-air temperature VREF = 0.8V (unless otherwise noted). CL = 30 pF for B Port and CL = 50 pF for A Port. Symbol tOSLH (Note 20) tOSHL (Note 20) tPV(HL) (Note 21) (Note 22) tOSLH (Note 20) tOSHL (Note 20) tPV(HL) (Note 21) (Note 22) tOSLH (Note 20) tOSHL (Note 20) tOST (Note 20) tPV (Note 21) tOSLH (Note 20) tOSHL (Note 20) tOST (Note 20) tPV (Note 21) CLKAB CLKAB A A B B CLKAB A A A 0.3 0.3 0.5 CLKAB B B A 0.3 0.3 0.6 A CLKAB B B 0.3 0.3 From (Input) A To (Output) B Min Typ (Note 19) 0.4 0.4 Max 1.0 1.0 1.5 0.9 0.6 1.2 1.0 1.0 1.5 1.6 0.6 0.6 1.0 1.1 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns
Note 19: All typical values are at VCC = 3.3V, and TA = 25°C. Note 20: tOSHL/tOSLH and tOST—Output to output skew is defined as the absolute value of the difference between the actual propagation delay for all outputs within the same packaged device. The specifications are given for specific worst case VCC and temperature and apply to any outputs switching in the same direction either HIGH-to-LOW (tOSHL) or LOW-to-HIGH (tOSLH) or in opposite directions both HL and LH (tOST). This parameter is guaranteed by design and statistical process distribution. Actual skew values between the GTL outputs could vary on the backplane due to the loading and impedance seen by the device. Note 21: tPV—Part to part skew is defined as the absolute value of the difference between the actual propagation delay for all outputs from device to device. The parameter is specified for a specific worst case VCC and temperature. This parameter is guaranteed by design and statistical process distribution. Actual skew values between the GTL outputs could vary on the backplane due to the loading and impedance seen by the device. Note 22: Due to the open drain structure on GTL outputs, tOST and tPV(LH) in the A-to-B direction are not specified. Skew on these paths is dependent on the VTT and RT values on the backplane.
11
www.fairchildsemi.com
GTLP16T1655
Test Circuits and Timing Waveforms
Test Circuit for A Outputs Test Circuit for B Outputs
Test tPLH/tPHL tPLZ/tPZL tPHZ/tPZH
S Open 6V GND
Note A: CL includes probes and Jig capacitance. Note B: For B-Port, C L = 30 pF is used fort worst case.
Voltage Waveform - Propagation Delay Times
Voltage Waveform - Setup and Hold Times
Voltage Waveform - Pulse Width
Voltage Waveform - Enable and Disable Times
Output Waveform 1 is for an output with internal conditions such that the output is LOW except when disabled by the control output Output Waveform 2 is for an output with internal conditions such that the output is HIGH except when disabled by the control output
Input and Measure Conditions A or LVTTL Pins VinHIGH VinLOW VM VX VY 3.0 0.0 1.5 VOL + 0.3V VOH − 0.3V B or GTLP Pins 1.5 0.0 1.0 N/A N/A
All input pulses have the following characteristics: Frequency = 10MHz, tRISE = t FALL = 2 ns, ZO = 50Ω The outputs are measured one at a time with one transition per measurement
www.fairchildsemi.com
12
GTLP16T1655
Physical Dimensions inches (millimeters) unless otherwise noted
64-Lead Thin Shrink Small Outline Package, JEDEC MO-153, 6.1mm Wide Package Number MTD64
13
www.fairchildsemi.com
GTLP16T1655 16-Bit LVTTL/GTLP Universal Bus Transceiver
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. www.fairchildsemi.com 14 2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com