FERROXCUBE
DATA SHEET
3C34 Material specification
Supersedes data of September 2004 2008 Sep 01
Ferroxcube
Material specification
3C34 SPECIFICATIONS A medium frequency, high Bsat power material optimized for use in line output transformers at frequencies up to 0.3 MHz. SYMBOL µi µa B CONDITIONS 25 °C; ≤10 kHz; 0.25 mT 100 °C; 25 kHz; 200 mT 25 °C; 10 kHz; 1200 A/m 100 °C; 10 kHz; 1200 A/m 100 °C; 100 kHz; 100 mT 100 °C; 100 kHz; 200 mT DC; 25 °C VALUE 2100 ±20% 6500 ±25% ≈ 500 ≈ 440 ≤ 60 ≤ 400 ≈5 ≥ 240 ≈ 4 800 Ωm °C kg/m3 mT mT kW/m 3
10 10 1 1 10 f (MHz) 10 2
3C34
10 4 handbook, halfpage µ's , µ'' s 10 3 µs '
CBW575
3C34
UNIT
µ'' s
PV
10 2
ρ TC density
Fig.1
Complex permeability as a function of frequency.
CBW468
5000 µi 4000
3C34
handbook, halfpage
500
CBW439
B (mT) 400
25 oC 100 oC
3C34
3000
300
2000
200
1000
100
0 50
0 50 150 T ( o C) 250 25 0 25 50 150 H (A/m) 250
Fig.2
Initial permeability as a function of temperature.
Fig.3 Typical B-H loops.
2008 Sep 01
97
Ferroxcube
Material specification
3C34
handbook, halfpage
8000 µa 6000
CBW442
25 oC o 100 C
3C34
10 4 handbook, halfpage µ rev
CBW577
3C34
10 3
4000
10 2 2000
0 0 100 200 300 B (mT) 400
10 1 10 10 2
3 H (A/m) 10
Fig.4
Amplitude permeability as a function of peak flux density.
Fig.5
Reversible permeability as a function of magnetic field strength.
10 4 handbook, halfpage T = 100 oC Pv (kW/m 3) 10 3
CBW454
CBW470
3C34
handbook, halfpage
800
3C34 f B (kHz) (mT)
Pv (kW/m 3 ) 600
200 kH z 100 50 25 kHz kHz kHz
100 400
200
10 2 200 200 100
25 100 10 1 10 10 2 B (mT) 10 3 0 0 40 80 T (o C) 120
200 100
Fig.7 Fig.6 Specific power loss as a function of peak flux density with frequency as a parameter.
Specific power loss for several frequency/flux density combinations as a function of temperature.
2008 Sep 01
98
Ferroxcube
Material specification
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
3C34
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
99
很抱歉,暂时无法提供与“3C34”相匹配的价格&库存,您可以联系我们找货