FERROXCUBE
DATA SHEET
3E8 Material specification
Supersedes data of September 2004 2008 Sep 01
Ferroxcube
Material specification
3E8 SPECIFICATIONS A high permeability material optimized for use in wideband transformers and delay lines where small size or a low number of turns are important design parameters. CONDITIONS µi B 25 °C; ≤10 kHz;0.25 mT 25 °C; 10 kHz; 1200 A/m 80 °C; 10 kHz; 1200 A/m 25 °C; 10 kHz; 0.25 mT 25 °C; 30 kHz; 0.25 mT 25 °C; 10 kHz; 1.5 to 3 mT DC; 25 °C VALUE(1) UNIT
3E8
10 5 handbook, halfpage µ's , µ'' s 10 4
CBW461
3E8
µs '
18000 ± 20% ≈ 380 mT ≈ 210 ≤ 10 × 10−6 ≤ 30 × 10−6 ≤ 1 × 10−3 ≈ 0.1 ≥ 100 ≈ 5 000
10 3
tanδ/µi ηB ρ TC density Note
T −1 Ωm °C kg/m3
10 10 2
2
10
1
1
f (MHz)
10
1. Measured on sintered, non-ground ring cores of dimensions Ø14 × Ø9 × 5 which are not subjected to external stresses.
Fig.1
Complex permeability as a function of frequency.
handbook, halfpage
40000 µi 30000
CBW463
3E8
CBW465
handbook, halfpage
500
B (mT) 400
25 oC 80 oC
3E8
20000 300
10000
200
100 0 50 50 150 T ( o C) 250 0 25 0 25 50 150 H (A/m) 250
Fig.2
Initial permeability as a function of temperature.
Fig.3 Typical B-H loops.
2008 Sep 01
169
Ferroxcube
Material specification
3E8
10 5 handbook, halfpage µ rev 10 4
CBW467
3E8
10 3
10
2
1
10
10 2
H (A/m) 10
3
Fig.4
Reversible permeability as a function of magnetic field strength.
2008 Sep 01
170
Ferroxcube
Material specification
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
3E8
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
171