FERROXCUBE
DATA SHEET
E13/6/3 E cores and accessories
Supersedes data of September 2004 2008 Sep 01
Ferroxcube
E cores and accessories
CORE SETS Effective core parameters SYMBOL Σ(I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core half VALUE 2.74 281 27.8 10.1 10.1 ≈ 0.7 UNIT mm−1 mm3 mm mm2 mm2 g
handbook, halfpage handbook, halfpage
E13/6/3
12.7 ±0.25 9.5 ±0.25 3.2 ±0.13 4.1 ±0.13
5.7 ±0.13
3.18 ±0.13
CBW556
Dimensions in mm.
Fig.1 E13/6/3 core half.
Core halves AL measured in combination with a non-gapped core half, clamping force for AL measurements, 8 ±4 N. GRADE 3C90 AL (nH) 63 ±5% 100 ±8% 160 ±8% 250 ±20% 315 ±20% 730 ±25% 3C92 3C94 3C96 540 ±25% 730 ±25% 660 ±25% µe ≈138 ≈ 219 ≈ 350 ≈ 548 ≈ 690 ≈1 590 ≈1 180 ≈1 590 ≈1 440 AIR GAP (µm) ≈ 250 ≈140 ≈ 75 ≈ 40 ≈ 30 ≈0 ≈0 ≈0 ≈0 TYPE NUMBER E13/6/3-3C90-A63 E13/6/3-3C90-A100 E13/6/3-3C90-A160 E13/6/3-3C90-A250 E13/6/3-3C90-A315 E13/6/3-3C90 E13/6/3-3C92 E13/6/3-3C94 E13/6/3-3C96
Core halves of high permeability grades AL measured in combination with an non-gapped core half, clamping force for AL measurements, 8 ±4 N. GRADE 3E27 AL (nH) 1300 ±25% µe ≈ 2 830 AIR GAP (µm) ≈0 TYPE NUMBER E13/6/3-3E27
2008 Sep 01
311
Ferroxcube
E cores and accessories
Properties of core sets under power conditions B (mT) at GRADE H = 250 A/m; f = 25 kHz; T = 100 °C ≥ 320 ≥ 370 ≥ 320 ≥ 340 f = 25 kHz; ˆ B = 200 mT; T = 100 °C ≤ 0.03 − − − CORE LOSS (W) at f = 100 kHz; ˆ B = 100 mT; T = 100 °C ≤ 0.03 ≤ 0.022 ≤ 0.024 ≤ 0.019 f = 100 kHz; ˆ B = 200 mT; T = 100 °C − ≤ 0.16 ≤ 0.15 ≤ 0.13
E13/6/3
f = 500 kHz; ˆ B = 50 mT; T = 100 °C − − − ≤ 0.11
3C90 3C92 3C94 3C96
2008 Sep 01
312
Ferroxcube
E cores and accessories
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
E13/6/3
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
313
很抱歉,暂时无法提供与“E3-3C90-A315”相匹配的价格&库存,您可以联系我们找货