MOVING COIL TYPE INDICATOR
DATA SHEET
The moving coil type indicator receives various types of input signals, DC voltage, DC current, and signals from thermocouple and resistance bulbs.
PAJ
FEATURES
1. Input signal can be directly connected. 2. High input impedance (1MΩ at 1 to 5V DC input). No adjusting resistor is required for thermocouple input. 3. Compact and lightweight design.
SPECIFICATIONS
Measuring input: Signal A; 1 to 5V DC B; 4 to 20mA DC DC current D; 0 to 100µA ....... 200mA DC DC voltage E; 0 to 10mV ........ 5V DC Thermocouple F; 0 to 10mV DC or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) Thermocouple G; 10mV DC span or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) Resistance bulb H; JPt100Ω 50°C span or more 3-wire type W; Pt100Ω 50°C span or more 3-wire type Slide resistant (resistance span; 100Ω) J; 3-wire type K; 2-wire type (with adjusting resistor) Opening angle transmitter (resistance span: 100Ω) L; 3-wire type (zero point and span adjustable)
Input resistance and allowable input signal source resistance:
Input signal 1 to 5V Voltage Others 4 to 20mA Current Others Thermocouple Resistance Input resistance 1MΩ 40kΩ to 1MΩ 5Ω 1 to 100Ω 40 to 600kΩ – 100Ω or less (50Ω or less when burnout is provided) 6Ω or less per wire Allowable input signal source resistance 2kΩ or less 100Ω or less – –
± 1.0% of full scale 100mm Within 3 sec (time required for stabilizing the indicator pointer within ± 1.5% after applying input corresponding to 2/3 (approx.) of full scale) Power supply: 100V ± 10% AC, 50/60Hz *200V ± 10% AC, 50/60Hz, or +15% *24V –10% AC, 50/60Hz Power consumption: Approx. 1.8VA max. Ambient temperature: –10 to +50°C Ambient humidity: 30 to 90%RH Enclosure: Steel case External dimensions (H × W × D): 48 × 144 × 210mm Mass{weight}: Approx. 1.5kg Finish color: Munsell 7.5BG 3.2/0.8 or equivalent Scope of delivery:Indicator and mounting bracket Allowance: Scale length: Response time:
EDS10-45e
Date July. 15, 1993
PAJ
Mounting method: Panel flush mounting Standard; Horizontal mounting on vertical panel Non-standard; Tilted mounting, vertical mounting Specify ∠α when mounting on tilted panel
OUTLINE DIAGRAM (Unit : mm)
CODE SYMBOLS
12345678 9
PAJ
0
2
Description
A B D E F G H W J K L
*Z *1 3 *5 0 3
Input signal 1 to 5V DC 4 to 20mA DC 0 to 100µA.....200mA DC 0 to 10mV.....5V DC 0 to 10mV DC or more (with reference junction compensator) 10mV DC span or more (with reference junction compensator) Resistance bulb JPt100Ω 50°C span or more, 3-wire type Resistance bulb Pt100Ω 50°C span or more, 3-wire type Slide resistant, 3-wire type Slide resistant, 2-wire type (with circuit adjusting resistor) For opening angle indicator (resistance; 100Ω, zero point and span adjustable) Other inputs Power supply 24V AC 50/60Hz 100V AC 50/60Hz 200V AC 50/60Hz Application For general use For zener barrier connection Specify "3" only when connecting to zener barrier (PWZB3 or PWZB4) with thermocouple or resistance bulb input used. 1 2 Mounting method Horizontal mounting Vertical mounting
CONNECTION DIAGRAMS
ORDERING INFORMATION
1. 2. 3. 4. Product name Code symbols Input Scale 5. Power supply 6. Application 7. Other necessary information
Notes: Symbols of resistance bulbs are as follows. JPt100 Previous JIS standard Pt100 New JIS standard
• A sterisked (*) items; Non-standard *Before using this product, be sure to read its instruction manual in advance.
Caution on Safety
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng
Instrumentation Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan
很抱歉,暂时无法提供与“EDS10-45E”相匹配的价格&库存,您可以联系我们找货