0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS10-72B

EDS10-72B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS10-72B - ALARM SETTER WITH DIGITAL DISPLAY - Fuji Electric

  • 数据手册
  • 价格&库存
EDS10-72B 数据手册
ALARM SETTER WITH DIGITAL DISPLAY DATA SHEET This product is a digital type alarming indicator whose front face measures 48 x 48 mm. PCP FEATURES 1. Eight alarm modes are selectable for a variety of applications. 2. Front-face waterproof structure (NEMA-4X) is available. 3. SPDT contact relay output is provided in a pair. 4. Input signal and measurable range are changeable by key operation. SPECIFICATIONS Operational specifications Input section: No. of inputs: 1 point Input signal: See table 1. Measuring range: See table 1. Burnout function: Upscale or downscale burnout settable The instrument with burnout releasing function can also be specified. Input sampling period: 0.5 sec Input impedance: Voltage input; 1MΩ or 450kΩ or more Current input; 250Ω (external mounted resistor) Thermocouple; 1MΩ or more Allowable resistance of signal supply: Thermocouple input; 100Ω or less Voltage input; 1kΩ or less Alarm output: No. of outputs 2 points of SPDT contact Kinds of alarm: See table 2. each point independently settable Contact capacity: 220V AC/30V DC, 3A (resistance load) 220V AC/30V DC,1A (inductive load) Alarm value settable range: -5 to 105% FS (each point independently settable) Hysteresis settable range: 0 to 102% FS (each point independently settable) Alarm action delay time: Settable within 1 to 10 sec Alarm action delay time at power-on: Settable within 0 to 20 sec Indicating section: Numerical indication: 7-segment, 4-digit LED (upper stage red, lower stage green) Indicated contents: Alarm set value 1, alarm set value 2, measured value Status indication: Red/green LED lamp. alarm occurrence, power ON, measured value indication Indicating accuracy: Thermocouple input: ± 0.5% FS ± 1 digit ± 3˚C (For B thermocouple 0 to 400˚C, ± 5% FS ± 1 digit ± 3˚C) (For R thermocouple 0 to 500˚C, ± 1% FS ± 1 digit ± 3˚C) Resistance bulb input: ± 0.5% FS ± 1 digit Voltage/current input: ± 0.5% FS ± 1 digit Rated voltage: 100 (-15%) to 240 (+10%)V AC 50/60Hz 24V AC (± 10%) 50/60Hz 24V DC (± 10%) Power consumption: 6VA max. (at 100V AC or 24V AC) 8VA max. (at 200V AC) 3W max. (at 24V DC) Ambient temperature: -10 to 50˚C External dimensions: 48 (W) x 48 (H) x 93 (D) mm Casing color: White or black (when front is waterproof) Mass : Approx.150 g Mounting method: Panel flush mounting or rail mounting (According to specified socket) (Note) For socket, see OUTLINE DIAGRAM Input signal and measuring range • Table 1 Input signal Resistance bulb JIS (IEC) Resistance bulb JIS (IEC) Group I (Note 1) Measurable range (℃)(Note 2) -150 to 800 Minimum span (℃) 150 Pt100Ω JPt100Ω -150 to 600 150 400 400 1600 1800 1600 599 800 1300 1300 Group II J 0 to 800 ThermoK 0 to 1200 couple R 0 to 1600 B 0 to 1800 T 0 to 1600 E -199 to 400 S -199 to 800 N 0 to 1300 PL-II 0 to 1300 DC voltage DC1 to 5V Scalable range DC0 to 5V -1999 to 9999 DC current DC4 to 20mA -50 to 100 0 to 150 Group III Thermistor Fuji-made thermistor 150 150 Note 1) Input signal can be changed by key operation within the same group, but cannot be changed between different groups. Note 2) When the measuring range exceed 1000˚C, decimal point cannot be used. EDS10-72b Date Nov. 27, 2003 PCP • Table 2 Kind of alarm Hold value Relay and Alarm method Set value at startup LED action Without alarm Upper limit Lower limit Upper limit Lower limit Upper limit Lower limit Upper limit Lower limit Absolute value Absolute value Absolute value Absolute value Absolute value Absolute value Absolute value Absolute value Not provided Not provided provided provided Not provided Not provided provided provided LED lit,relay excited LED lit,relay excited LED lit,relay excited LED lit,relay excited LED lit,relay unexcited LED lit,relay unexcited LED lit,relay unexcited LED lit,relay unexcited Action diagram CODE SYMBOLS 12345678 9 10 11 12 13 14 PCP YY1 4 T N P H C B A 1 F Description Front size (W x H) 48 x 48mm Note 1 Input signal Thermocouple Resistance bulb Pt100, 3-wire type Resistance bulb JPt, 3-wire type Note 2 Thermistor DC1 to 5V (Input impedance: 1MΩ) Note 3 DC4 to 20mA DC1 to 5V (Input impedance: 450Ω) ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ △ △ △ △ △ △ △ △ △ Revision No. F N Y V C A B 000 400 500 Alarm With 2 alarm points Instruction manual/power supply Not provided/100 to 240 V AC, 50/60 Hz Japanese version/100 to 240 V AC, 50/60 Hz English version/100 to 240 V AC, 50/60 Hz Not provided/ 24V DC Japanese version/ 24V DC English version/ 24V DC Socket Not provided For rail mounting, type: TP411X Note 4 For panel flush mounting, type: Note 4 TP411SBA With burnout releasing function For rail mounting, type: TP411X How to read action diagram area : Range in which front LED is lit area : Range in which alarm relay is excited P04 P05 P06 Y D For panel flush mounting, Note 4 type: TP411SBA Without socket Non-standard specification White casing without front waterproof structure Black casing with front waterproof Note 5 structure (NEMA-4X) Note 4 △ : Alarm set value Note 1) Input signal has been factory-set as follows. Thermocouple input: K thermocouple 0 to 400˚C Resistance bulb input: 0 to 150˚C Thermistor input: 0 to 150˚C Voltage/current input: Scaling 0 to 100% Note 2) Use a thermistor that matches Fuji Electric's specifications. Note 3) Before use, attach the accessory 250Ω resistor between input terminals. Note 4) If a socket of any type other than specified is used, input accuracy cannot be guaranteed. Note 5) Contact us to select P for the 11th digit, because it is nonstandard. OUTLINE DIAGRAM (Unit:mm) External dimensions 48 7 85.7 71.5 Panel Mounting frame 48 Panel cutout 45 +0.5 0 +0.5 0 1 45 44.8 57 48 63 MIN. Lateral installation of multiple indicators in close contact (48×N-3) +0.5 0 t Mounting frame Packing 1≦t≦8 (used for front waterproof structure) Note) Impossible for front waterproof structure 2 45 +0.5 0 9.5 63 MIN. 57 CONNECTION DIAGRAM • For AC power supply <Measured value input> 6 250Ω 5 5 5 6 6 B A B 6 5 4 Note 1 Thermocouple T.C. + 5 6 7 8 SET1 9 10 1 11 4 to 20mA DC 1 to 5V DC Thermistor 3 4 SET2 2 Power supply 100 to 240V AC 50/60Hz Alarm output 1 Resistance bulb Alarm output 2 • For 24V DC power supply Note 1 6 250Ω 5 5 5 <Measured value input> 6 6 B A B 6 5 4 Thermocouple T.C. + 5 6 7 8 SET1 9 10 1 11 4 to 20mA DC 1 to 5V DC Thermistor 3 4 SET2 2 Power supply 24V DC / 24V AC 50/60Hz Resistance bulb Alarm output 2 Alarm output 1 Note 1) For 4 to 20mA DC input, attach the accessory 250 Ω resistor between terminals t and y. APPLICABLE SOCKET (Unit:mm) TP411X type (rail mounting) Terminal screw M3.5×8 5 87 6 4 35.4 70 25.6 45 TP411SBA type (panel mounting) 4.5 φ27 Terminal screw M3.5×7 5 4 3 2 6 7 8 9 10 7 Two φ4.5 9 holes 10 1 11 11 1 3 2 45 4 4.5 16.3 6.2 7.8 50 31.2 or less 40±0.2 Two φ4.5 mounting holes 3 PCP SCOPE OF DELIVERY Indicator main frame, fixture set, instruction manual (as specified in code), soket (as specified in code), shunt resistor (250Ω) (for current input), panel face packing (for front waterproof structure) Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS10-72B 价格&库存

很抱歉,暂时无法提供与“EDS10-72B”相匹配的价格&库存,您可以联系我们找货

免费人工找货