FC SERIES ELECTRONIC INDICATOR
DATA SHEET
The FC series electronic indicator uses a solid state indicator as an indicating element, completely eliminating the need for mechanical moving parts and provides high reliability. Use of two indicating elements has enabled arrangement of many monitoring points in a limited space, which is useful to compare monitoring points influenced by one another.
PNJ1
FEATURES
1. Outstanding reliability The adoption of a solid state indicator has completely eliminated the need for mechanical moving parts, providing excellent reliability. 2. Two-point indicator This instrument indicates 2 different values at the same time, so a large number of mounting points can be arranged in a small space, whereby monitoring points influenced by one another can easily be compared and indicated. 3. International standards This instrument is compact in size, conforming to the international standards of IEC. It operates on 24V DC power to deliver 1 to 5V DC signals as recommened by IEC standards. 100V and 200V AC power are also available for convenience of operation. It also accepts a thermocouple, a resistance bulb or a 4 to 20mA DC input converter optionally. 4. Digital indication/setting function Input signals can be read accurately from the digital indicator on the front panel. Various parameters can also be set on the front of the panel.
FUNCTIONAL DIAGRAM
EDS11-107e
Date Jan. 27, 1999
PNJ1
SPECIFICATIONS
1. Input signal
(1) Analog input signal: 2 points
Indicating input 1* Indicating input 2* AI1 AI2 1 to 5V DC Input resistance, 1MΩ or more Allow. error ± 0.2%/FS
4. Power failure processing functions
Power failure detection: Alarm output "OFF" at power failure detection. During power failure: Data backed up by capacitor within 5 minutes. Alarm set data stored in nonvolatile memory (more than 10 years at ambient temperature of 50° C or less). Power failure recovery: Initial or continuous start set within 5 minutes of power failure. Recovery from power failure exceeding 5 minutes is initial.
* Indicating input 1 select from the following inputs. Current input signal Thermocouple input I+ I0 I– Resistance bulb input 4 to 20mA DC 24V DC power supplied to transmitter during AC operation 10mV DC span or more Basic contact compensating function 50°C span or more Allow. error ± 0.5%/FS Allow. error ± 0.2%/FS Allow. error ± 0.5%/FS
Type J:0 to 600°C K:0 to 1200°C E:0 to 800°C R:0 to 1600°C Pt100/Pt100 –50 to 500°C
5. Self-diagnosis functions
Input signal abnormality: FLT lamp lights, FLT contact output "ON". Indication of abnormal contents: Cause of abnormality indicated in numerical values on front panel.
2. Output signal
(1) Analog output signal: 2 points
Indicating input 1 com- AO1 pensation Indicating input 2 com- AO2 pensation Output resistance, 1Ω or less Allow. error ± 0.2%/FS
1 to 5V DC
6. Other functions
Data protective function by pass code
(2) Digital output signal: 5 points
Fault output High alarm output 1 Low alarm output 1 High alarm output 2 Low alarm output 2 FLT H1 L1 H2 L2 Open-collector output (photocoupler insulation) Output rating, 30V x 0.1A DC, max.
7. Operating conditions
Select from 3 types 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) Power consumption: Approx. 11W (DC) Approx. 20VA (AC) Dielectric strength: 1500V AC, 1 min. Insulation resistance: 500V DC, 100MΩ or more Ambient temperature: 0 to 50°C Ambient humidity: 90% RH or less Enclosure: Steel case Name plate: 100 (H) x 72 (W) mm, white acryl Dimensions: 144 (H) x 72 (W) x 391 (D) mm, IEC (DIN) standards Mass {weight}: Approx. 2.9kg Mounting method: Flush in door mounting; vertical mounting. Mountable on tilted surface, angle "α" Power supply:
3. Indication, alarm, setting, functions
(1) Bar graph indication
PV indicator Indication method Indication range Indication resolution Scale length Indicating mode LED (red) 0 to 100% linear 1 %/FS 100mm No. of indicating segments 101 + 2 GV indicator LED (green) 101 + 2 0 to 100%, linear 1%/FS 100mm
0 to 100% bar graph indication, 0 to 100% reverse bar graph indication, 0 to 100% dot indication
(2) Numerical value indication/setting Indication method: LED (red), name in 3 digits + numerical value in 5 digits (negative code included) Contens of indication: Indicating input signal (engineering unit), high/low alarm, etc. Contents of indication select by use of F/S, , , keys on front panel. Setting method: By using of F/S, , , , ST keys on front panel. (3) Alarm functions High/low alarm set in engineering unit for display of indicating signal. Indicating method: Two LED lamps (red) on front panel ..... High alarm lamp ..... Low alarm lamp
α=0° to 90°
Finish color:
Munsell N1.5 for both front panel and case Range of delivery: Electronic indicator and mounting bracket
CODE SYMBOLS
12345678
PNJ 1 A B C D E F G W
A
5
Description Indicating input 1 1 to 5V DC 4 to 20mA DC J thermocouple 10mV DC span or K thermocouple more E thermocouple Basic contact compensating function R thermocouple Resistance bulb, JPt100, 3-wire, 50°C span or more Resistance bulb, Pt100, 3-wire, 50°C span or more
1 2 3
Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC)
Note: Symbols of resistance bulbs are as follows. JPt100 ..... JIS C 1604-1981 Pt100 ..... IEC Pub751-1983 (JPt/Pt changeover is possible with front key.)
OUTLINE DIAGRAM
(Unit:mm)
Panel thickness 8mm or less
Terminal Terminal cover
16
Support bracket 140 36 355
200min.
Mounting bracket
144
72
Panel cutout
When mounting 1 unit
When mounting "n" units
250min.
200min.
+1 0
+1 0
No. of units n≥2 –
138
68
+0.7 0
(72.2n – 4)
+1 0
138
PNJ1
CONNECTION DIAGRAM
Block terminals (M4 screws)
AO Indicating input 1 compensation AO Indicating input 2 compensation AI, AO Common bus DO (Alarm output 1)
51 AO1 AO2 52 53 54 SC 55 56 57 58 59 60 61 62
71 72 73 74 75 76 77 78 79 80 81 82
AI2
AI (Indicating input 2)
– –
H1 L1 H2 L2 PC* PCD G
SC
AI, AO Common bus
DO (Alarm output 2)
Instrument power (24V DC, AC power) DI, DO 24V power Earth
VP* VPD
+
Instrument power (24V DC, AC power) + DI, DO 24V power
Note: * Symbols for AC instrument power are VPO, PCO, approx. 24V DC (0.1A max.) output
Connections for indicating input 1 terminals
1 to 5V DC The 5th digit of code symbols "A" 4 to 20mA DC The 5th digit of code symbols "B"
+ – + + –
11 31 12
Thermocouple The 5th digit of code symbols C,D,E,F Resistance bulb The 5th digit of code symbols G,W
+ –
+ –
11 31 12
+ –
11 31 12
+ –
11 31 12
4 to 20mA DC power supply The 5th digit of code symbols "B"
–
+ –
11 31 12 PC 60
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng
Sales Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.