0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS11-114B

EDS11-114B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-114B - FC SERIES MANUAL LOADER(STEP OUTPUT TYPE) - Fuji Electric

  • 数据手册
  • 价格&库存
EDS11-114B 数据手册
FC SERIES MANUAL LOADER (STEP OUTPUT TYPE) DATA SHEET One is used for remote control in combination with a compact controller, while the other is dedicated for manual operation. This instrument is equipped with a solid state indicator and pushbutton operation circuit to provide easy readouts and handling for process operation by man-machine communication. It can be directly connected to a thermocouple, resistance bulb or 4 to 20mA input optionally. PND3 FEATURES 1. High reliability The manual loader is a solid state instrument having few mechanical parts. The indicator and other units which formerly consisted of mechanical parts are also designed with solid state circuits to provide high reliability. 2. Application of international standards This instrument is compact, and the external dimensions comply with international IEC. The power supply and signal also comply with IEC standards (24V, 1 to 5V DC). Operation on 100V or 200V AC power supply is possible. 3. Front panel operation Process values, valve position input, etc. can be read accurately from the digital display on the panel front. Parameter setting and manual operation are also possible from the front of the panel. FUNCTIONAL DIAGRAM PV Square-root extraction MV Manual mode output (M) Linearize Process value input (PV) External MV input (Pulse width) (PI) Filter Compensated process value signal (KPV) A M Manipulated output (step output) (PO) Limiter Valve position read back (W) W/V H L MV High alarm output Manual mode command (SMV) ALM Low alarm output EDS11-114b Date Jan. 27, 1999 PND3 SPECIFICATIONS 1. Input signal (1) Process value input signal: One point of signal select from the following inputs Voltage input signal Current input signal Thermocouple input 1 to 5V DC 4 to 20mA DC I+ I0 Type I – J:0 to 600°C K:0 to 1200°C E:0 to 800°C R:0 to 1600°C JPt100 –50 to 500°C Input resistance, more than 1MΩ 24V DC power supplied to transmitter during AC operation 10mV DC span or more Basic contact compensating function 50°C span or more Allow. error ± 0.2%/FS* Allow. error ± 0.2%/FS* Allow. error ± 0.5%/FS* (2) Operation mode indication Indication method: LED (red and green) Red: M Green: A (3) Numerical indication, setting Indication method: LED (red), name in 3 digits + number in 5 digits (negative sign included) Indication contens: Process variable (industrial value), high/ low alarm, limiter value etc. Indication contents are select with F/S , , keys on front panel. Resistance bulb input Allow. error ± 0.5%/FS* Note: * FS: Full scale (2) Valve position input signal: 1 point Voltage input signal Resistance input signal W0 1 to 5V DC Input resistance, 1MΩ or more Allow. error ± 0.5%/FS* W+ 50 to 1000Ω 3-wire system potentiometer Allow. error ± 0.5/FS* W0 span** W– Setting method: By using F/S , , , , ST , keys on front panel (4) Operating functions Manual operating method: By using of , buttons on front panel Auto operating method: By pulse width input signal (5) Operation mode selection By using front panel A/M pushbutton A M selection Balanceless bumpless Note: ** : Basic design: 10 to 100 to 10Ω, others should be specified. (3) Pulse width input signal: 1 set Pulse width input signal PI+ PI– Contact input (photo-coupler insulation) ON 0V, OFF 24V (input current, approx. 11mA/24 DC) (6) Alarm function High/low alarm can be set in industrial values for process value input signal. 4. Power failure processing functions Power failure detection: Control output OFF at power failure detection. During power failure: Data backed up by capacitor when power failure occurs within 5 minutes. Initial value of data stored in non-volatile memory (last for more than 10 years at ambient temperature of 50° C or less). Power failure recovery time: Initial or continuous start set for power failure within 5 minutes. Recovery from power failure lasting longer than 5 minutes is done by initial. Note: Control mode at initialization set. M: Manual mode or A: Auto mode (4) Digital input signal: 1 set Manual mode command SMV Contact input (photo-coupler insulation) ON 0V, OFF 24V (input current, approx. 11mA/24 DC) 2. Output signal (1) Control output signal: 1 set Pulse width output signal P0+ P0– Open-collector output (phone-coupler insulation) Output rating, 30V x 0.1A DC, max. (2) Analog output signal: 1 point Compensated process value signal KPV 1 to 5V DC Output resistance, 1Ω or less Allow. error ± 0.2%/FS 5. Self-diagnosis functions Process value input signal abnormality: FLT indicator lights and FLT contact output turns ON. Fault contents indication: Cause of fault is indicated numerically on numerical indicator on the front panel. (3) Digital output signal: 4 points Fault output Manual mode output High alarm output Low alarm output FLT M H L Open-collector output (photo-coupler insulation) Output rating, 30V x 0.1A DC, max. 6. Other functions 3. Indication, setting, operating functions (1) Bar graph indication PV indicator Indication method Indication range Indication resolution Scale length Indication mode LED (red) 0 to 100%, linear 1 %/FS 100mm No. of indicating segments 101 + 2 MV indicator LED (red) 51 + 2 0 to 100%, linear 2%/FS 50mm Data protective function by use of pass code 7. Operating conditions Power supply: Selected from the following 3 types 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (87 to 264V/47 to 63Hz AC) Power consumption: Approx. 11W (DC) Approx. 20VA (AC) 0 to 100% bar graph indication, 0 to 100% reverse bar graph indication, 0 to 100% dot indication Dielectric strength: 1500V AC, 1 min. Insulation resistance: 100MΩ or more at 500V DC Ambient temperature: 0 to 50°C Ambient humidity: 90% RH or less Enclosure: Steel case Nameplate: 100 (H) x 72 (W) mm, white acryl Dimensions: 144 (H) x 72 (W) x 407 (D) mm, IEC (DIN) standards Mass{weight}: Approx. 2.9kg Mounting method: Flush with indoor pane; vertical mounting is standard. Mounting on tilted surface possible (angle "α") CODE SYMBOLS 12345678 9 PND3 A B C D E F G B 5- Description Process value input signal 1 to 5V DC 4 to 20mA DC with 24V DC power supply 10mV DC span or J thermocouple more, with reference K thermocouple contact compensatE thermocouple ing function R thermocouple Resistance bulb, Pt100, 3-wire, 50°C span or more B 1 2 3 1 2 Auxiliary analog input None Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) Valve position input signal Voltage input signal (1 to 5V DC) Resistance input signal (50 to 1000Ω span) (Note) α=0 to 90° Note: Basic: 10 to 100 to 10 Ω , others should be specified. Finish color: Munsell N1.5 for front panel and case Range of delivery: Manual loader and mounting bracket OUTLINE DIAGRAM Terminals (Unit:mm) Panel thickness 8mm or less 16 Supporting bracket 52 355 200min. Mounting bracket 144 72 Panel cutout When mounting one unit When mounting "n" units 250min. 200min. +1 0 +1 0 No. of units n2 138 68 +0.7 0 (72.2n – 4) +1 0 138 PND3 CONNECTION DIAGRAM Not use Compression terminal 01 02 03 04 W+ W0 W– SC SC MV SC SC I+ I0 I– KPV 31 32 33 34 35 36 37 38 39 40 41 P0 + P0 – PI + PI – H L FLT PCD PCD PC * M VPD VPD VP * SMV 42 43 44 45 46 47 48 49 + 50 + 51 + Process variable input AO (Compensated PV signal) Not use AO (Valve position transmission signal) AI, AO Common bus Valve position read back 05 06 07 AI, AO Common bus 08 09 Not use + PO (Plus width) (Manipulated output) DI (External MV input) DO (High alarm output) DO (Low alarm output) DO (FLT output) 24VDC power for DI, DO 24VDC power for DI, DO Instrument power (24VDC) – 10 11 12 13 14 15 16 17 18 Not use DO (Manual mode command) Not use DO (Manual mode) 24VDC power for DI, DO Instrument power (24VDC) Note: * Symbols for AC instrument power are VPO, PCO. Output : Approx. 24V DC (0.1A max.) – 19 – 20 – 21 G 71 AC 72 AC 73 Ground INstrument power (AC) Instrument power (AC) Process value input terminal connections 1 to 5V DC The 5th digit of code symbols: "A" 4 to 20mA DC The 5th digit of code symbols: "B" 4 to 20mA DC power The 5th digit of code symbols: "B" + – + – + – 31 32 33 PC 21 + – 31 32 33 Thermocouple The 5th digit of code symbols: C,D,E,F Resistance bulb The 5th digit of code symbols: G,W + – + – 31 32 33 + – 31 32 33 + – 31 32 33 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS11-114B 价格&库存

很抱歉,暂时无法提供与“EDS11-114B”相匹配的价格&库存,您可以联系我们找货

免费人工找货