0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS11-117C

EDS11-117C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-117C - FC SERIES ELECTRONIC INDICATOR - Fuji Electric

  • 数据手册
  • 价格&库存
EDS11-117C 数据手册
FC SERIES ELECTRONIC INDICATOR DATA SHEET The FC series electronic indicator uses a solid state indicator as an indicating element, completely eliminating the need for mechanical moving parts and provides high reliability. Use of two indicating elements has enabled arrangement of many monitoring points in a limited space, which is useful to compare monitoring points influenced by one another. PNJ3 FEATURES 1. Outstanding reliability The adoption of a solid state indicator has completely eliminated the need for mechanical moving parts, providing excellent reliability. 2. Two-point indicator This instrument indicates 2 different values at the same time, so a large number of monitoring points can be arranged in a small space, whereby monitoring points influenced by one another can easily be compared and indicated. 3. International standards This instrument is compact in size, conforming to the international standards of IEC. It operates on 24V DC power to deliver 1 to 5V DC signals as recommended by IEC standards. 100V and 200V AC power are also available for convenience of operation. It also accepts a thermocouple, a resistance bulb or a 4 to 20mA DC input converter optionally. 4. Digital indication/setting function Input signals can be read accurately from the digital indicator on the front panel. Various parameters can also be set on the front of the panel. FUNCTIONAL DIAGRAM EDS11-117c Date Jan. 27, 1999 PNJ3 SPECIFICATIONS 1. Input signal (1) Analog input signal: 2 points Indicating input 1* Indicating input 2* AI1 AI2 1 to 5V DC Input resistance, 1MΩ or more Allow. error ± 0.2%/FS 4. Power failure processing functions Power failure detection: Alarm output "OFF" at power failure detection. During power failure: Data backed up by capacitor within 5 minutes. Alarm set data stored in nonvolatile memory (more than 10 years at ambient temperature of 50° C or less). Power failure recovery: Initial or continuous start set within 5 minutes of power failure. Recovery from power failure exceeding 5 minutes is initial. * Indicating input 1 select from the following inputs. Current input signal Termocouple input 4 to 20mA DC 24V DC power supplied to transmitter during AC operation 10mV DC span or more Basic contact compensating function 50°C span or more Allow. error ± 0.5%/FS Allow. error ± 0.2%/FS Allow. error ± 0.5%/FS* Type I+ J:0 to 600°C I0 K:0 to 1200°C E:0 to 800°C I– R:0 to 1600°C Pt100 –50 to 500°C Resistance bulb input 5. Self-diagnosis functions Input signal abnormality: FLT lamp lights, FLT contact output "ON". Indication of abnormal contents: Cause of abnormality indicated in numerical values on front panel. 2. Output signal (1) Analog output signal: 2 points Indicating input 1 com- AO1 pensation Indicating input 2 com- AO2 pensation 1 to 5V DC Output resistance, 1Ω or less Allow. error ± 0.2%/FS 6. Other functions Data protective function by pass code (2) Digital output signal: 5 points Fault output High alarm output 1 Low alarm output 1 High alarm output 2 Low alarm output 2 FLT H1 L1 H2 L2 Open-collector output (photocoupler insulation) Output rating, 30V x 0.1A DC max. 7. Operating conditions Select from 3 types 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) Power consumption: Approx. 11W (DC) Approx. 20VA (AC) Dielectric strength: 1500V AC, 1 min. Insulation resistance: 500V DC, 100MΩ or more Ambient temperature: 0 to 50°C Ambient humidity: 90% RH or less Enclosure: Steel case Nameplate: 100 (H) x 70 (W) mm, white acryl Dimensions: 144 (H) x 72 (W) x 407 (D) mm, IEC (DIN) standards Mass {weight}: Approx. 2.9kg Mounting method: Flush in door mounting; vertical mounting. Mountable on tilted surface, angle "α" Power supply: 3. Indication, alarm, setting, functions (1) Bar graph indication PV indicator Indication method Indication range Indication resolution Scale length Indication mode LED (red) 0 to 100% linear 1 %/FS 100mm No. of indicating segments 101 + 2 GV indicator LED (green) 101 + 2 0 to 100% linear 1%/FS 100mm 0 to 100% bar graph indication, 0 to 100% reverse bar graph indication, 0 to 100% dot indication (2) Numerical value indication/setting Indicating method: LED (red), name in 3 digits + numerical value in 5 digits (negative code included) Contents of indication: Indicating input signal (industrial value), high/low alarm, etc. Contents of indication select by use of F/S, , , keys on front panel. Setting method: By use of F/S, , , , ST keys on front panel. (3) Alarm functions High/low alarm set in industrial values for display of indicating signal. Indicating method: Two LED lamps (red) on front panel ..... High alarm indicator ..... Low alarm indicator α=0° to 90° Finish color: Munsell N1.5 for both front panel and case Range of delivery: Electronic indicator and mounting bracket CODE SYMBOLS 12345678 PNJ 3 A B C D E F G 5 Description ndicating input 1 1 to 5V DC 4 to 20mA DC with 24V DC power supply J thermocouple 10mV DC span or K thermocouple more E thermocouple Basic contact comR thermocouple pensating function Resistance bulb, Pt100, 3-wire, 50°C span or more T he product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510402. The applicable standards used to demonstrate compliance are :- EN 55011 : 1991 CLASS A EN 50082-1 :-1992 Conducted and Radiated emissions Radiated immunity, ESD and FBT A C 1 2 3 IIndicating input 2 1 to 5V DC 4 to 20mA DC with 24V DC power supply Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) OUTLINE DIAGRAM Terminals (Unit:mm) Panel thickness 8mm or less 16 Supporting bracket 52 355 200min. Mounting bracket 144 72 Panel cutout When mounting 1 unit When mounting "n" units +1 0 250min. 200min. +1 0 138 68 +0.7 0 (72.2n – 4) +1 0 138 No. of units n2 PNJ3 CONNECTION DIAGRAMS AI (Indicating input2) Compression terminal 01 02 03 04 05 06 AI2 I+ I0 I– AO1 AO2 31 32 33 34 35 36 SC SC SO1 IR1 IO1 H1 L1 SC SC 37 38 39 40 41 42 43 44 45 H2 L2 FLT PCD PCD PC * VPD VPD VP * 46 47 48 49 + 50 + 51 + AI (Indicating input 1) AO Analog output 1 AO Analog output 2 AI, AO Common bus 07 08 AI, AO Common bus 1 to 5VDC signal output DC power for Transmitter – + 09 10 11 DO (High alarm output) DO (Low alarm output) DO (High alarm output) DO (Low alarm output) DO (FLT output) 24VDC power for DI, DO 24VDC power for DI, DO Instrument power (24VDC) 12 13 14 15 16 17 18 – 19 – 20 – 21 24VDC power for DI, DO Instrument power (24VDC) Note: * Symbols for AC instrument power are VPO, PCO. Output : approx. 24V DC (0.1A max.) G 71 AC 72 AC 73 Ground Instrument power (AC) Instrument power (AC) Connections for indicating input 1 terminals 1 to 5V DC The 5th digit of code symbols "A" 4 to 20mA DC The 5th digit of code symbols "B" 4 to 20mA DC power supply The 5th digit of code symbols "B" + – + – + – 31 32 33 PC 21 + – 31 32 33 Thermocouple The 5th digit of code symbols C,D,E,F Resistance bulb The 5th digit of code symbols G,W + – + – 31 32 33 + – 31 32 33 + – 31 32 33 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS11-117C 价格&库存

很抱歉,暂时无法提供与“EDS11-117C”相匹配的价格&库存,您可以联系我们找货

免费人工找货