0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS11-119D

EDS11-119D

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-119D - FC SERIES COMPACT CALCULATOR - Fuji Electric

  • 数据手册
  • 价格&库存
EDS11-119D 数据手册
FC SERIES DATA SHEET COMPACT CALCULATOR PNM3 The FC series compact calculator is a high cost-performance, flexible, and highly functional calculator which inputs 5 analog signals and 6 digital signals, digitally performs complex calculations such as arithmetic, square root extraction, time-factor calculations, etc., and then provides 5 analog and 6 digital outputs. FEATURES 1. Highly functional calculator using a microprocessor A variety of calculating functions are coordinated into functional units called wafers. Complex calculations are thus performed flexibly and accurately through connection of the computational wafers. 2. International standards This instrument is compact in size, conforming to international standards IEC. It operates on 24V DC power to deliver 1 to 5V DC signals as recommended by IEC standards. 100V and 200V AC power are also available for convenience of operation. 3. Contents of calculation are changeable on the spot The contents of calculation can be specified on the spot by means of key operation on the front. And the contents are retained even at power failure due to utilization of a non-volatile memory. FUNCTIONAL DIAGRAM EDS11-119d Date Aug. 15, 1996 PNM3 SPECIFICATIONS 1. Computational functions (1) Wafers The wafer is a functional software package which realizes the computational functions needed for instrumentation control. A calculator which responds flexibly to the application purpose is realized through combination of these wafers having their own individual functions. The PNM is capable of executing a total of either 24, 48 or 64 wafers. The wafers given in the table below are standardequipped which enables selection according to the purpose of application. • For computation: A variety of computations are feasible by combining the wafers in Table 1. (2) Internal input/output terminals Various internal terminals for connecting external analog input/outputs and digital input/outputs with wafers are provided. (3) Constants These can be freely defined as parameters for use in calculation. (32 constants with 24 wafers, 48 constants with 48 wafers, 64 constants with 64 wafers) Table 1 List of computational wafers Wafer name Logical computation Arithmetic computation Temperature/pressure compensation Linearize Flip-flop Pulse width integration Selector Changeover Timer Square root computation Lead, lag Limiter Absolute value sign inversion Ramp function Analog average Analog integration Pulse generation Dead band Pulse number counter Pulse number output Decoder Moving average Sample hold Dead time On-off Alarm Position type pulse width change Kinds 6 5 1 3/6/8 1 1 1 1 1 1 3 1 1 2 1 1 1 1 1 1 1 2 1 9 1 1 1 Outline of functions Performs logical computation such as AND, OR, NOT, EOR and a combination of these. Performs computation such as addition, subtraction, multiplication and division. Performs temperature/pressure compensation using differential pressure, correcting pressure and/or proper temperature. Performs segmented line approximation using 15 segmented line functions (6 kinds with 48 wafers, 8 kinds with 64 wafers). RS flip-flop Adds the input change amount at each basic cycle to the previous integrated value. Compares two input values, and outputs the result of high/low judgment as HIGH output (higher one) or LOW output (lower one). A switch function which selects either input or output. An analog hold circuit can also be combined. Outputs an on-delay/off-delay timer signal via input signal start according to the timer setting. Subjects an input value to square root extraction and outputs the result. Also has a low input cutoff function. Subjects the input to lead or lag computation and outputs the result. Used for analog filter function and various compensations. Limits the input within the range of upper/lower limit setting and outputs the result. Also outputs an upper/lower limit alarm signal. Subjects the input to absolute value processing and outputs the result. Also judges the input value sign (positive, negative) and outputs the results. Outputs a signal which changes in ramp-like form toward the target value within the set full-scale time. Includes two kinds for minute and hour unit. Subjects the input data to sequential integration, calculates the average for each average value calculation time and outputs the result. Integrates the value obtained by multiplying the input data via a proportional constant, and outputs the result. Outputs a pulse at a set time interval. Adds dead band compensation to the input and outputs the result. Detects the rise of a pulse and counts the number of pulses. Integrates the input signal, converts it to number of pulses and outputs the result. Decodes binary input of two bits and outputs it at 4 terminals. Calculates moving average for the input data and outputs the result. Holds the input value according to sample time and outputs it successively. Usable for dead time compensation control, etc. Data sampling is available in units of 1 second and 1 minute. Outputs an on-off signal with hysteresis versus the input. Compares the input with the set value, and outputs the judgment result. Performs output processing for time-proportional PID control. Various applications are feasible by combining encoder, saw-tooth wave generating and sine wave generating wafers. 2 2. Input signal (1) Analog input signal Al1: One point selectable from the following inputs Voltage input signal Current input signal Thermocouple input I+ I0 I– 1 to 5V DC 4 to 20mA DC Input resistance: 1MΩ or more; accuracy: ± 0.2%/FS(*) 24 ± 2V DC can be supplied to transmitter when using AC source; accuracy: ± 0. 2%/FS 10mV DC span or more; cold junction compensation comprised accuracy: ± 0.5%/FS 50°C span or more; accuracy: ± 0.5%/FS (2) Digital data Input/output status ON (contact closed) OFF (contact open) Data 0.01% 0.00% 5. Indication, setting, operating functions (1) Bargraph indication Indicator Indication type No. of segments Range Resolution Scale length RV indicator LED (red) 101+2 0 to 100% linear 1%/FS 100mm GV indicator LED (green) 101+2 0 to 100% linear 1%/FS 100mm Type J :0 to 600°C K:0 to 1200°C E:0 to 800°C R:0 to 1600°C Pt100 –50 to 500°C Resistance bulb input (2) Analog input signal: 4 points Analog input Analog input Analog input Analog input AI2 AI3 AI4 AI5 1 to 5V DC Input resistance: 1MΩ or more Accuracy: ± 0.2%/FS Indication mode 0 to 100% bargraph indication 0 to 100% reverse bargraph indication dot indication –50 to +50% deviation indication (3) Digital input signal: 4 points Digital input Digital input Digital input Digital input DI1 DI2 DI3 DI4 Contact input (photocoupler insulation) ON/0V, OFF/24V (input current approx. 11mA/24V DC) (4) Pulse width or pulse number input signal: One set Pulse width input signal Pulse number input signal PI+ PI– Contact input (photocoupler insulation) ON/0V, OFF/24V (input current approx. 11mA/24V DC) ON/0V, OFF/24V (approx. 11mA/24V DC); input max. frequency: 500Hz (2) Run mode indication Indicating method: LED (red); red, H/L (3) Numerical indication, setting Indication method: LED (red), name in 3 digits+numerals 5 digits (including negative sign) Indication contents: Indication contents such as constants, segmented line and wafers selectable by and keys on the front. F/S , Setting method: By operation of F/S , , , , and ST keys on the front. 6. Power failure processing function Power failure detection: Calculation stops at power failure detection. During power failure: Operating parameters retained by capacitor backup within 5 minutes. Constants, segmented line, wafers, parameters etc. are stored in non-volatile memory (lasts for 10 years expected at ambient temperature below 50 °C). At power recovery: Initial or continuous start mode can be set versus power failure within 5 minutes. Recovery from power failure lasting longer than 5 minutes is done by initial. 3. Output signal (1) Current output signal: One point Current output MI+ MI– 4 to 20mA DC Allowable load resistance: 600Ω or less; accuracy: ± 0.2%/FS (2) Analog output signal: 4 points Analog output Analog output Analog output Analog output AO1 AO2 AO3 AO4 1 to 5V DC Output resistance: 1Ω or less; accuracy: ± 0.2%/FS (3) Digital output signal: 6 points Fault output Digital output Digital output Digital output Digital output Digital output FLT DO1 DO2 DO3 DO4 DO5 Open collector output (Photocoupler insulation) Output rating 30V x 0.1A DC max. 7. Self-diagnosis functions Computing circuit fault: H, L lamp simultaneously lit FLT contact output ON, computation stops Input/output signal fault, run output disconnection: H, L lamp simultaneously lit; FLT contact output ON, computation and output processing for other than run output continue. Fault contents indication: Cause of fault is numerically indicated on front-panel numerical indicator 4. Internal uniform data conversion (1) Analog data Standard 0.00 to 100.00% Note: *FS: Full scale Minimum –327.6% Maximum 327.67% 3 PNM3 8. Transmission functions (1) Transmission items Monitor items: PNM host Fault information, constants, analog input/ output, digital input/output, etc. Setting, operating items: Host PNM Constants, etc. (2) Transmission setting inhibit: Parameter setting enable/inhibit can be designated by transmission from the host. Deisgnation is done by keys on the front panel. (3) Transmission interface (a) T-link: Private interface Transmission speed: 500Kbps No. of units connectable: 32 max. Transmission distance: 1km max. Transmission form: Multi-drop Control method: I/O transmission and message (b) RS-422A/485: Universal interface Transmission speed: 2400, 4800, 9600 or 19200bps configurable No. of units connectable: 31 max. Transmission distance: 1km max. Transmission form: Multi-drop Control method: Polling/selecting Mounting method: Indoor panel mounting, vertical mounting standard, can be tilted within following angle α = 0° to 90° Finish color: Front panel; Munsell N1.5 Casing; Munsell N1.5 Scope of delivery: Calculator and mounting bracket Item to be ordered separately: Transmission cable (type PNZ) CODE SYMBOLS 12345678 9 10 11 P NM 3 A B C D E F G 5-0 Description Measured input signal 1 to 5V DC 4 to 20mA DC with 24V DC power supply J thermocouple 10mV DC span or K thermocouple more, with cold juncE thermocouple tion compensation R thermocouple Resistance bulb, Pt100 3-wire type, 50 °C span or more 9. Other functions Data protective function using pass code 10. Usage conditions Power supply: Selectable from three types 24V DC (20 to 30V DC), 100V AC (85 to 132V AC/47 to 63Hz), 200V AC (187 to 264V AC/47 to 63Hz) Power consumption: Approx. 12W (DC), approx. 20VA (AC) Dielectric strength: 1500V AC for 1 minute Insulation resistance: 100MΩ or more at 500V DC Ambient temperature: 0 to 50 °C Ambient humidity: 90% RH or less Enclosure: Steel plate casing Casing protective structure: Front section (IP65, IEC 529) Rating plate (Name plate): 100 (H) x 70 (W), white acrylic resin Outer dimensions: 144 (H) x 72 (W) x 407 (D) mm, conforming to IEC (DIN) standards Mass {weight}: Approx. 2.9kg B C Auxiliary input four 1 to 5V DC input two 4 to 20mA DC with 24V DC power supply plus two 1 to 5V DC input 1 2 3 Y T R S 0 2 4 Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V AC/47 to 63Hz) 200V AC (187 to 264V AC/47 to 63Hz) Transmission functions None T-link RS-422A RS-485 Available wafer numbers 24 wafers 48 wafers 64 wafers The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510402. The applicable standards used to demonstrate compliance are :- EN 55011 : 1991 CLASS A EN 50082-1 :-1992 Conducted and Radiated emissions Radiated immunity, ESD and FBT 4 OUTLINE DIAGRAM (Unit:mm) Panel thickness 8mm or less Terminals 16 52 Supporting bracket 200min. 355 Mounting bracket 144 72 Panel cutout When mounting 1 unit 250 or more 200 or more When mounting "n" units +1 0 +1 0 No. of units n= >2 138 68 +0.7 0 (72.2n – 4) +1 0 CONNECTION DIAGRAM AI (Aux. analog input) AI (Aux. analog input) AI (Aux. analog input) AI (Aux. analog input) AO (Aux. analog output) Not use Al, AO Common bus 1 to 5V DC signal output Compression Terminal 01 02 03 04 05 06 07 08 09 – + + – SC SC SO1 IR1 IO1 MI+ MI– PI+ PI– DO4 DO5 FLT PCD PCD PC* AC AC 72 73 Ground Instrument power (AC) Instrument power (AC) AI2 AI3 AI4 AI5 AO4 I+ Io I– AO1 AO2 AO3 SC SC SO2 IR2 IO2 DI4 DI1 DI2 DI3 DO2 DO1 DO3 VPD VPD VP* 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 + + + – + DC power for Transmitter AO (Aux. analog output) AO (Aux. analog output) AO (Aux. analog output) AI, AO Common bus 1 to 5V DC signal output Analog input (AI1) DC power for Transmitter AO (current output) 10 11 12 13 14 15 16 17 18 – – – 19 20 21 G 71 DI (Pulse input) DO (Aux. digital output) DO (Aux. digital output) DO (FLT output) 24V DC power for DI, DO 24V DC power for DI, DO Instrument power (24V DC) DO (Aux. digital output) DI (Aux. digital input) DI (Aux. digital input) DI (Aux. digital input) DO (Aux. digital output) DO (Aux. digital output) DO (Aux. digital output) 24V DC power for DI, DO Instrument power (24V DC) Note: * symbols for AC instrument power are VPO, PCO. Output: Approx. 24V DC (0.1A, max.) 138 5 PNM3 Analog input (AI1) terminals connections 1 to 5V DC The 5th digit of code symbols A 4 to 20mA DC The 5th digit of code symbols B 4 to 20mA DC with inner DC power supply of CC-S The 5th digit of code symbols B + – Thermocouple 31 32 33 + – + – 31 32 33 The 5th digit of code symbols C,D,E,F Resistance bulb + – + – + – 31 32 33 The 5th digit of code symbols G + – 31 32 33 + – 31 32 33 PC 21 Transmission connector 6 7 8 RXD + 9 RXD – 1 SIG GND 2 SHLD(SD) 3 INH 4 TXD + (T1) 5 TXD – (T2) Green Red Yellow Brown Black White 6 7 8 RXD + 9 RXD – 1 SIG GND 2 SHLD(SD) 3 INH 4 TXD + (T1) 5 TXD – (T2) Note:Symbol in ( ): T-link terminal symbol 6 7 8 RXD + 9 RXD – TERMINATION RESISTOR 1 SIG GND 2 SHLD(SD) 3 INH 4 TXD + (T1) 5 TXD – (T2) 6 7 8 RXD + 9 RXD – 1 SIG GND 2 SHLD(SD) 3 INH 4 TXD + (T1) 5 TXD – (T2) Green Red Yellow Brown HOST MASTER CONTROLLER Black White Final controller 1st controller Host Termination resistor Transmission cable PNM3 PNM3 PNM3 PNM3 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS11-119D 价格&库存

很抱歉,暂时无法提供与“EDS11-119D”相匹配的价格&库存,您可以联系我们找货

免费人工找货