EDS11-141B

EDS11-141B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-141B - DIGITAL THERMOSTAT - Fuji Electric

  • 数据手册
  • 价格&库存
EDS11-141B 数据手册
DIGITAL THERMOSTAT DATA SHEET This product is an on/off temperature alarm unit which inputs signals from a thermocouple or thermistor sensor and transmits a relay contact output when an input signal reaches the preset alarm level. This thermostat is most suited for overheat detection in machines, equipments, etc. PAS3 FEATURES 1. Highly compact Front panel having a DIN size of 24 x 48 mm, as lightweight as 100 g and besides, depth just 85 mm, featuring a space saving design. 2. A variety of temperature sensors connectable Because thermocouples (5 types) and thermistors (0 to 100°C) are connectable, measurement within a wide temperature range from low to high can be covered so as to match your equipment. 3. Measured and Alarm Temperatures Displayable Alarm set value and measured temperature value can be checked promptly using the front keys. 4. Alarm point settable in 1°C steps Temperature can be set in 1°C steps by key operation from the front. 5. Washable front structure The front display and operating section has an IP66 waterproof structure (corresponding to NEMA-4X). This design allows washing from the panel front. 6. 2 relay contact outputs available This thermostat is capable of issuing 2 relay contact outputs. Therefore, any output of high/low limit pair, 2 upper limits and 2 lower limits can be selected. SPECIFICATIONS Specification Number of inputs: 1 Input signal and measurable range: Refer to Table 1. Allowable signal source resistance: Thermocouple input 100 Ω max. Measurement cycle: 2 sec. or less Burnout function: Thermocouple input; UUU display Thermistor input: LLL display (Upscale or downscale at burnout settable) Input impedance: Thermocouple input 1 MΩ or higher Input filter: 0 to 90 sec. (settable in 1 sec. steps) Primary lag filter Input value compensation: Settable within ±10% of measurable range Indication Indication means: LCD (without back light) Value/parameter indication: 4 digits of 7 segments each (However, at the 1st digit, only - or 1 is indicated within -999 to 1999.) Contents of indication: Measured value, alarm set value 1, alarm set value 2, various parameters Each indicator of alarms 1 and 2, ˚C scale Operation Number of keys: 3 keys, sheet type keys (embossed) Alarm value setting resolution: 1˚C Key lock function: (Change of setting can be inhibited.) Accuracy Indication accuracy: Refer to Table 1. (However, error of a temperature sensor is not included.) Reference contact compensation error: ±3˚C (at 23˚C) Alarm Number of outputs: 1 or 2 (as specified in CODE SYMBOLS) output Contact structure: 1a contact Alarm type: Refer to Table 2. Contact capacity: 220 V AC/30 V DC, 2 A (resistance load) 220 AC/30 DC, 1 A (inductive load) Mechanical life of contact: 20 million activations or more (100 activations/min.) Electrical life of contact: 100,000 activations or more (rated load) Output resetting cycle: 2 sec. or less Alarm value settable range: Settable within 0 to 100% of measurable range Hysteresis width settable range: 0 to 110% of measurable range (settable in 1˚C steps) Alarm action delay time: Settable within 1 to 120 sec. Item Input Item Power supply Specification Power supply voltage: 100 V (–15%) to 240 V (+10%) AC 50/60 Hz (±10%) Power consumption: 3 VA max. (with 100 V AC), 6 VA max. (with 240 V AC) Operating Ambient temperature: 0 to 50˚C conditions Ambient humidity: 90% RH max. (condensation unallowable) Body Mounting method: Panel flush mounting Use of optional DIN rail-mounting adapter allows the instrument to be rail mounted or wall mounted. structure External dimensions (H x W x D): 24 x 48 x 85 mm Weight: Approx. 100 g Casing material: Plastic (corresponding to flame resistance grade UL94V-0) Front protective structure: IP66 (corresponding to NEMA-4X) when using Fuji’s genuine front waterproof packing part External terminals: Plug-in type (for bar terminals) Finish color: Ivory Table 1 Input signal, measurable range and indication acurasy Input signal Thermocouple J K R T E Thermistor PB-36 Measurable range (˚C) 0 to 800 0 to 1200 0 to 1600 0 to 400 0 to 600 0 to 100 Minimum resolution 1˚C 1˚C 4˚C 1˚C 1˚C 1˚C Indication accuracy ±3˚C ±3˚C ±4˚C ±3˚C ±3˚C ±4˚C Note 1) Correct indication is not ensured within a range from 0 to 500˚C for an R type thermocouple. Note 2) Switching between a thermistor and a thermocouple is not allowed. Thermocouple input type can be changed by front key operation. EDS11-141b Date Apr. 1, 2011 PAS3 Table 2 Alarm types With Relay Code of Alarm Set value holding action PA1, 2 direction notation (Note 2) at alarm 0 1 2 3 4 5 6 7 8 No alarm Upper limit – Absolute value – No No Yes Yes No No Yes Yes – Relay excitation Relay excitation Relay excitation Relay excitation Relay nonexcitation Relay nonexcitation Relay nonexcitation Relay nonexcitation Action diagram (Note 1) CODE SYMBOLS Input signal Temperature sensor Number of alarm Thermocouple Option 1 2 Thermistor Provided 1 2 Code symbols PAS3K1Y1 PAS3K1A1 PAS3H1Y1 PAS3H1A1 Lower Absolute value limit Upper limit Absolute value OPTIONAL DEVICE DIN rail adapter (Model: ZZP*CTK368715P1) Lower Absolute value limit Upper limit Absolute value SETTING at DELIVERY Measurable range Alarm set value K thermocouple input (0 to 1200˚C) Thermistor input (0 to 100˚C) K thermocouple input: For 1-point alarm (upper limit 1200˚C) K thermocouple input: For 2-point alarm (upper limit 1200˚C, lower limit alarm 0˚C) Thermistor input: For 1-point alarm (upper limit 100˚C) Thermistor input: For 2-point alarm (upper limit 100˚C, lower limit alarm 0˚C) 1˚C 0 sec. Measured value Upscale at burnout 5 sec. 0% Lower Absolute value limit Upper limit Absolute value Lower Absolute value limit (Note 1) How to read action area: A range in which “ALM1 or ALM2” is indicated on LCD at the front. area: A range in which alarm relay is excited point: Alarm set value The horizontal axis represents measured values (PV). (Note 2) What is the hold function? Even if the process value is within the alarm range when turning on power, the alarm does not turn on immediately but only after it leaves and then returns to the alarm range. PV (process value) Period where lower limit alarm is output Power ON Lower limit alarm Lower limit alarm (with hold) Power OFF on off off off on Alarm hysteresis width Alarm delay time Indication Burnout Input filter Input value compensation Note 1) Switching between a thermistor and a thermocouple is not allowed. Note 2) Thermocouple input type can be changed by front key operation. Power ON on off off SCOPE of DELIVERY Thermostat unit, panel-mounting adapter, front waterproof packing, instruction manual Thermistor sensor added for thermistor input Fig. 1 Alarm output hysteresis width Alarm output hysteresis width (˚C) Alarm output (1˚C) ON ATTACHED THERMISTOR SENSOR • Attachment for thermistor-input thermostat Measurable range B constant Nominal resistance value Lead wire Lead wire length Lead wire heat resisting temperature Color code Accuracy 0 to 100˚C 3390 K 6 kΩ (0˚C) Heat-resisting vinyl chloride wire 500 mm –20 to 105˚C Black Within ±2˚C Example) Alarm set value 50˚C Alarm output hysteresis width 1˚C Example 49˚C Set value 50˚C • Outline diagram (unit: mm) φ 6.5 MAX. Epoxy resins (black) Heat-resisting parallel vinyl chloride wire (12/0.18 TA)(black) About 520 5 20 MAX. CODE SYMBOLS of SPARE THERMISTOR SENSOR ZZP*CTK7L3491P1 OUTLINE DIAGRAM (Unit:mm) Waterproof packing 1 48 PV SET1 SET2 ALM1 ALM2 34.2 24 4 84 85 Mounting adapter Panel (1 ≤ t ≤ 8) PANEL CUTOUT DIAGRAM (Unit:mm) For mounting “n” units 45.0 +0.5 0 22 For close mounting in horizontal direction (48 X n–3) +0.5 0 +0.3 0 22.2 50 MIN. 22.2 +0.3 0 This mounting does not meet NEMA-4X/IP66 (front waterproof specification). (Because the packing cannot be used in horizontally close mounting.) 57 MIN. DIN RAIL ADAPTER 52.4 PV SET1 SET2 45.4 ALM1 ALM2 2- ø4 .3 DIN rail DIN rail adapter (option) For wall mounting 43.8 96.2 92.5 4 M MFD. No. 9 36.8 PAS3... MAX. torque 0.49Nm PAS3 CONNECTION DIAGRAM USABLE WIRING MATERIALS • Wire 2 2 Gauge: AWG28 (0.1 mm ) ... AWG16 (1.25 mm ) AWG28...AWG16 Strip-off length: 5 to 6 mm 1 2 – 3 + 4 5 6 7 8 9 5 to 6 mm Thermocouple input Alarm output 1 Alarm output 2 Power supply AC 100-240 V 50/60 Hz • Bar terminal Dimension of strip-off conductor section: 2 x 1.5 mm or smaller Length of strip-off conductor section: 5 to 6 mm 1.5MAX. 2MAX. 5 to 6 mm 2 3 Thermistor CONNECTION METHOD PAS3 Screw driver Wires
EDS11-141B 价格&库存

很抱歉,暂时无法提供与“EDS11-141B”相匹配的价格&库存,您可以联系我们找货

免费人工找货