EDS11-159C

EDS11-159C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-159C - PX series digital temperature controller MICRO-CONTROLLER X (48 × 96 mm) - Fuji Electri...

  • 数据手册
  • 价格&库存
EDS11-159C 数据手册
PX series digital temperature controller DATA SHEET MICRO-CONTROLLER X (48 × 96 mm) PXG5 PXG5 is a compact size temperature controller of front panel size 48 × 96 mm. To cope with any of versatile uses as a temperature controller, it has many input/output points and sophisticated control functions. FEATURES 1. Wide variety and number of input / output 1. Digital input: Up to 5 points 2. Digital output: Up to 5 points 3. Control output: 4 types Relay contact, SSR drive, voltage linear, current linear 4. Universal inputs: Thermocouple, resistance bulb, current, voltage, mV linear 5. Remote SV input function 6. Analog re-transmission output function (for current or voltage) 7. Motorized valve control output 2. User interface of easy-to-see indication and easy-to-use operation method 1. Easy-to-see, large display section 2. Parameters grouped by functions 3. User key to which you can assign a function 4. Password function provided for avoiding wrong operation and protecting settings 5. Front water-proof structure (IP66 in conformity) 3. Advanced control functions to meet various applications 1. Sampling cycle 200 ms (300 ms at position feedback control) 2. Input indication accuracy ± 0.3%FS 3. Manual control function 4. Control method selectable out of 8 different types: ON/OFF control, PID control, fuzzy PID control, selftuning control, PID2 control, motorized valve control (with/without position feedback) 5. Heating/cooling control selectable 6. Auto tuning function 4. A variety of functions extending the possibility of temperature controller 1. Guarantee soak function provided, 16 step ramp/soak function 2. 8 PID setting pallets, 8 SV pallets capable of frequent change of control 3. Soft start function that limits MV output when starting up 4. Ramp SV function enables graduate change of SV 5. Loop burnout alarm, heater burnout alarm and different event outputs are available in digital output (option) 6. Control standby function 7. Loader interface (RS232C) 8. RS485 communication (option) SPECIFICATIONS 1. General Specifications (1) Power supply : 100 V ( - 15%) to 240 V (+ 10%) AC, 50/60 Hz 24 V (± 10%) DC. 24 V (± 10%) AC, 50/60 Hz. (2) Power consumption: 12 VA MAX. (3) Insulation resistance: 20 MΩ MIN. (at 500 V DC) (4) Withstand voltage: Power source ⇔ all terminals 1500 V AC for 1 min Relay contact output ⇔ all terminals 1500 V AC for 1 min Between others 500 V AC for 1 min (5) Approvals and certification: UL(UL873), C-UL(CSA C22.2 No.24-93 or equivalent), CE mark(LVD : EN61010-1, EMC : EN61326-1) EDS11-159c Date Apr. 1, 2011 PXG5 2. Input section 2.1 Process value input (1) Number of inputs: 1 point (2) Input setting: Programmable scale (3) Input signal: See Table 1 (thermocouple, resistance bulb, mV, voltage, , current(With external 250Ω resistance) universal input) (4) Standard measurement range and input type: See Table 1 (5) Indication accuracy (at Ta = 23˚C) : • Thermocouple input: ± 0.3%FS ± 1 digit ± 1˚C or ± 2˚C, whichever greater *except: Thermocouple B, 0 to 400˚C ± 5%FS ± 1 digit ± 1˚C Thermocouple R, 0 to 500˚C ± 1%FS ± 1 digit ± 1˚C Thermocouple T, -200 to 0˚C ± 0.5%FS± 1 digit ± 1˚C • Resistance bulb input: ± 0 .3%FS ± 1 digit or ± 0.5˚C, whichever greater • mV input, voltage input, current input: ± 0.3%FS ± 1 digit (6) Indication accuracy by change of temperature: ± 0.3%FS/10˚C (7) Indication resolution: See Table 1 (8) Input sampling cycle: 200 ms (300 ms at position feedback control) (9) Input impedance: • Thermocouple, mV input: 1 MΩ MIN. • Current input: 250 Ω • Voltage input: About 1 MΩ (10) Variation by signal source resistance: • Thermocouple, mV input: ± 0.3%FS ± 1 digit per 100 Ω • Voltage input: ± 0.3%FS ± 1 digit per 500 Ω (11) Allowable wiring resistance: • Resistance bulb: 10 Ω MAX. (per wire) (12) Allowable input voltage: • DC voltage input: Between +35 and -10 V • Current input: Within ± 25 mA • Thermocouple, resistance bulb, mV input: Within ± 5 V (13) Noise rejection ratio: • Normal mode: 40 dB (50/60 Hz) • Common mode: 120 dB (50/60 Hz) From ground, at 220 V AC, 50/60 Hz Between input and output, at 220 V AC, 50/60 Hz (14) Input correction: (a) User adjustment: Zero point, span ± 50%FS for each (b) Process value shift: ± 10%FS (c) Input filter: 0.0 to 120.0 sec (filter OFF if set at 0.0) (15) Overrange, underrange: Beyond range of -5 to 105% (accuracy not guaranteed between -5 and 0, and between 100 and 105%FS) 2.2 Auxiliary analog input (remote SV input) (1) Number of inputs: Up to 1 point (2) Input signal: Voltage, 0 to 5 V DC /1 to 5 V DC (3) Input impedance: About 1 MΩ (4) Sampling rate: 800ms (600ms at Position feed back control) 2.3 Heater current detector (CT) input Single phase CT Up to 1 point max. For 1 to 30 A: CTL-6-S-H For 20 to 50 A: CTL-12-S36-8F (2) Range of detected current: 1 to 50A (3) Detected current accuracy: Setting ± 10%FS (4) Detected current resolution: 0.1 A (5) ON time necessary for detection: 800 ms MIN. (1) Input type: 2.4 Digital input (DI) (1) Number of points: Up to 5 points (up to 3 points for motorized valve control output) (2) Specifications: No-voltage contact or transistor input (3) Contact capacity: 30 V DC, about 3 mA (per point) (4) Input judgment: ON assumed at 1 kΩ or lower (contact) or 5 V DC or lower (transistor) OFF assumed at 100 kΩ or higher (contact) or 18 V DC or higher (transistor) (5) Sampling pulse width: 200 ms MIN. (300 ms MIN. at position feedback control) (6) Functions: Remote mode selection, SV changeover, control standby, AT startup, timer startup, alarm unlatch, Program selection, start / stop / reset, PID switching (normal/reverse), etc. 2.5 Valve position feedback signal (potentiometer) input (1) Resistance range: 100 Ω to 2.5 kΩ, 3 wire type (2) Resolution: 0.5%FS (3) Input accuracy: ± 1.0%FS (4) Effect of temperture variation: ± 0.5%FS/10˚C (5) Burnout detection: none 2 3. Output section 3.1 Control output (1) Number of points: Up to 2 points (2 points: Heating/cooling control) (2) Type: selected out of [1] to [5] below [1] Relay contact output • Proportional cycle: 1 to 150 sec • Contact structure: 1 NO (SPST) contact • Contact capacity 220 V AC/30 V DC, 3 A (resistive load) 220 V AC/30 V DC, 1 A (inductive load) • Minimum Open/Close current: 100 mA (24 V DC) • Mechanical life: 20 million operations MIN. (100 operations/min) • Electrical life: 100,000 operations MIN. (rated load) [2] SSR/SSC drive output • Proportional cycle: 1 to 150 sec • ON voltage: 20 V DC (18 to 24 V DC) • OFF voltage: 0.5 V DC or lower • Maximum current: 20 mA DC (for each of outputs 1 and 2) • Load resistance: 850 Ω MIN. [3] Current output (0 to 20 mA DC/4 to 20 mA DC) • Accuracy: ± 5%FS • Linearity: ± 5%FS • Load resistance: 600 Ω MAX. [4] Voltage output (0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC) • Accuracy: ± 5%FS • Linearity: ± 5%FS • Load resistance: 10 kΩ MIN. [5] Motorized valve control output • Contact structure: 2 NO (SPST) contacts • Contact capacity: 220 V AC/30 V DC, 1A • Minimum ON/OFF current: 100 mA (24 V DC) • Mechanical life: 20 million operations MIN. (100 operations/min) • Electrical life: 100,000 operations MIN. (rated load) • Output interlock: Output interlock circuit provided (2) Output specifications: (1) Relay contact output Contact structure: 1 NO (SPST) contact Contact capacity: 220 V AC/30 V DC, 1A Minimum ON/OFF current: 100 mA (24 V DC) Mechanical life: 20 million operations MIN. (100 operations/min) Electrical life: 100,000 operations MIN. (rated load) (2) Transitor output Contact type: Open collector Rated values: 30 V DC, 100 mA ON voltage: 1V or lower (3) Output functions: Alarm output (see "Alarm function") Main unit control mode output, program status output, etc. (4) Output cycle: 200ms (300ms at Position feedback control) 3.3 Auxiliary analog output (re-transmission output) (1) Number of points: 1 point (2) Type: Current/voltage output (0 to 20 mA DC/4 to 20 mA DC/0 to 5 V DC/1 to 5 V DC/ 0 to 10 V DC/2 to 10 V DC) • Guaranteed output range: 0 to 20.6 mA DC/0 to 10.3 V DC • Accuracy: ± 0.2%FS (± 5%FS at 1 mA or smaller) • Linearity: ± 0.2%FS (± 5%FS at 1 mA or smaller) • Resolution: 5000 MIN. • Load resistance 600 Ω MAX. (current) 10 kΩ MIN. (voltage) (3) Output update cycle: 200ms (Position feedback type: 300ms) (4) Output contents: PV, SV, DV, MV (5) Additional function: Scaling function (6) Restriction: Cannot be selected when control output 2 is used. 4. Indication/setting section 4.1 Display unit (1) Type: LED (2) Indication contents: Process value indication: 7 segments, 4 digits [red] Setpoint indication: 7 segments, 4 digits [green] Indication status: 6 indicator lamps 3.2 Digital output (DO) (1) Number of outputs: Relay contact output Up to 3 points (shared common) Up to 2 points (independent common) Transistor output Up to 2 points 4.2 Setting section (1) Type: Sheet type keys (with emboss) (2) Number of keys: 4 keys. SEL , , p lus user function key 3 PXG5 5. Control functions 5.1 Control types (1) 2-position control (set parameter P to 0%) (2) PID control (fuzzy PID included) • PID parameters determination: Auto tuning, Selftuning (3) PID dual (heating, cooling) function (fuzzy PID included) • PID parameters determination: Auto tuning (4) Motorized valve control (position feedback or servo control) • Full stroke time: 30 sec MIN. 7. Communication function 7.1 RS-485 interface (1) Number of points: 1 point (2) Physical specifications: EIA RS485 (3) Protocol: Modbus-RTU (4) Communication method: Half duplex bit serial, Asynchronous communication (5) Code type: Data length 8 data bits. Parity Odd, even, none. (6) Communication rate: 9600 bps, 19200 bps (7) Connection status: Up to 32 units connectable including multidrop master function (8) Communication distance: Up to 500 m (total connect extension) 5.2 Control parameters • Proportional band (P): 0.0 to 999.9%. 2-position control when P = 0. • Integral time (I): 0 to 3200 sec. Integral time control invalidated when I = 0. • Differential time (D): 0.0 to 999.9 sec. Differential time control invalidated when D = 0. • Control cycle: 200 ms (300 ms at position feedback control) • Anti-reset windup: 0 to 100% of measurement range • Hysteresis band: 50% of measurement range (at 2-position control only) • Number of SV and PID combinations: 8 combinations. Changed by any of parameter setting, digital input, communication and user function keying 8. Processing at power failure • Memory protection: Protect by non-volatile memory 9. Self-diagnosis • Method: Program error supervision by watchdog timer 10. Operation and storage conditions (1) Operating ambient temperature: -10 to 50˚C (2) Storage temperature: -20 to 60˚C (3) Operating/storage ambient humidity: 90%RH MAX. (no condensing) (4) Warm-up time: 30 min MIN (5) Vibration: 10 to 70 Hz, 9.8 m/s2 (1 G) MAX. (6) Impact: 49 m/s2 (5 G) MAX. 5.3 Control mode Auto, Manual, Remote * In case of 2 position control in manual mode, 2 positions correspond to MV = 100 or 0%. (2) Mode changeover: Auto↔Manual: Balanceless · bumpless Auto/Manual→Remote: Balance · bumpless Auto/Manual←Remote: Balance · bumpless (1) Mode type: 11. Structure (1) Mounting method: Mounted with panel (2) External terminals: Screw terminals, M3 (3) Case: • Material: ABS, and degeneration PPO • Non-combustibility grade: UL94V-0 equivalent • Color: Black (4) Protection structure: • Panel front side: IP66, NEMA-4X equivalent (if panel is mounted using our genuine packing. Not water-proof if mounted closely together.) • Body: IP20 equivalent (slits on top and bottom) • Terminals: IP00 equivalent. Terminal cover can be mounted optionally. (5) Dimensions: 48 (W) × 96 (H) × 80 (D) mm (6) Mass: About 300 g 6. Alarm function 6.1 Number of alarm setting points • Up to 5 points (depends on number of DO) 6.2 Alarm type • Process value (upper limit/lower limit, absolute/deviation, range), main unit error, etc. (non-excitation, delay, latch, timer function option provided) 6.3 Heater burnout alarm function (1) Detectable range: 1 to 50 A (2) Detected current resolution: 0.1 A (3) Setting resolution: 0.1 A (4) Hysteresis: 0.0 to 50.0 A 4 12. Scope of delivery • • • • • • Controller: Instruction manual: Fixture: Water-proof packing: Shunt resistor: Unit nameplate: 1 1 2 1 1 1 unit copy pcs pc pc pc 13. User customize function 13.1 Program (ramp/soak) function (1) Number of program steps: 16 steps × 1 pattern, 8 steps × 2 patterns, or 4 steps × 4 patterns (1 step = 2 segments) (2) Control option: Control by digital input Status output by digital output (3) Basic function: [1] Segment time can be set in "Hour, Minutes" or "Minutes, Seconds" [2] Guarantee soak [3] Repeat action [4] PV start [5] Delay start [6] Power failure restoring function (4) Memory backup: EEPROM 13.2 User functions • Pressing the user key can perform Auto/Manual change, Standby ON/OFF change, remote SV change, ramp/soak change or other function as assigned 13.3 Password function • 3 level password function 5 PXG5 CODE SYMBOLS Standard type 12345678 9 1011 12 13 Digit P XG 5 Digit Specifications 4 48 × 96mm 5 Relay contact SSR drive Current (0 to 20 mA DC/4 to 20 mA DC) Voltage (0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC) 6 None Relay contact SSR drive Current (0 to 20 mA DC/4 to 20 mA DC) Voltage (0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC) Re-transmission output, current (0 to 20 mA DC/4 to 20 mA DC) Re-transmission output, voltage (0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC) 7 None RS485 Digital input (No.1) + Digital input (No.2) Digital input (No.1) + RSV1 Digital input (No.1) + CT1 RS485 + Digital input (No.1) RS485 + RSV1 RS485 + CT1 RS485 + Digital input (No.1) + RSV1 Digital input (No.1) + RSV1 +Digital input (No.2) 8 9 (relay contact output) None Digital output 1 point (No.1) Digital output 2 points (No.1,2) Digital output 3 points (No.1,2,3) Digital output 2 points [independent common] (No. 1, 2) 100 to 240 V AC, no instruction manual 100 to 240 V AC, Japanese instruction manual 100 to 240 V AC, English instruction manual 24 V AC/DC, no instruction manual 24 V AC/DC, Japanese instruction manual 24 V AC/DC, English instruction manual None Digital input (No.3,4,5) + CT2 Digital input (No.3,4,5) Digital input (No.3,4,5) + digital output (No.4,5) [transistor output] Digital input (No.3,4,5) + RSV2 None Note 5 A C E P Y A C E P R S Y M T H G V K J F 2 1 Note4 0 1 F M J N Y V C A B Y A B C D 00 Note1 Note1 Note3 Note3 Note3 Note3 Note3 Note3 Note2 Note1 Note4 Note5 Note2 Note1 Note4 Note5 Note2 Note3 Note2 Note3 10 11 Note1 Note4 Note5 Note2 12 13 Note 1: If output 1 was for current or voltage output, option cannot be assigned to CT1 nor CT2. (If 7th digit was assigned to G or J, or 11th digit to A, 5th digit cannot be assigned to E nor P.) Note 2: RSV1 in option 1 and RSV2 in option 2 cannot be assigned simultaneously. (If 7th digit was assigned to H, K, F, 2 11th digit cannot be assigned to D.) Note 3: In case, in option 1, of DI 2 points + RSV1 or RS485 + DI 1 + RSV1, output 2 cannot be assigned. (If 7th digit was assigned to F or 2, 6th digit cannot be assigned to A, C, E, P, R, nor S . Note 4: In case of CT1 in option 1, or CT2 in option 2, digital output cannot be assigned to None. (If 7th digit was assigned to G or J, or 11th digit to A, 9th digit cannot be assigned to 0.) Note 5: CT1 in option 1 and CT2 in option 2 cannot be selected simultaneously. (If 7th digit was assigned to G or J, 11th digit cannot be assigned to A.) 6 CODE SYMBOLS Motorized valve control type 12345678 9 1011 12 13 Digit P XG 5 Digit Specifications 4 48 × 96mm 5 Motorized valve control output (Without PFB) Motorized valve control output (With PFB) 6 None Auxiliary Digital output 7 None Digital input (No.1,2,3) + RSV1 RS485 + Digital input (No.1,2,3) RS485 + Digital input (No.1) + RSV1 8 9 (relay contact output) None Digital output 1 point (No.1) Digital output 2 points (No.1,2) Digital output 3 points (No.1,2,3) Digital output 2 points [independent common] (No. 1, 2) 100 to 240 V AC, no instruction manual 100 to 240 V AC, Japanese instruction manual 100 to 240 V AC, English instruction manual 24 V AC/DC, no instruction manual 24 V AC/DC, Japanese instruction manual 24 V AC/DC, English instruction manual None None Note 5 S V Y A Y E U F 1 0 1 F M J N Y V C A B Y 00 10 11 12 13 7 PXG5 OPTIONALLY ITEMS Instruction manual for communication functionRS485 (Modbus) Current detector for heater burnout alarm (CT) 1 to 30A 20 to 50A Rear terminal cover Shunt resistor 250Ω ± 0.1% PC loader communication cable Type:INP—TN514450—E Type:ZOZ *CCTL—6—S—H Type:ZOZ *CCTL12—S36—8F Type:ZZPPXR1—B230 Type:ZZPPXR1—A190 Type:ZZP PXH1 *TK4H4563 TABLE 1 [1] Unit of temperature: ˚C Input type Input code Measurement range [˚C] Max. Min. 0 to 150 -150 to 600 -200 to 850 Indication/setting resolution [˚C] Max. Min. 1 0.1 JPt100Ω Pt100Ω J Thermocouple K R B S T E N PLUnusable DC voltage DC0 to 5V DC1 to 5V DC0 to 10V DC2 to 10V DC0 to 100mV DC0 to 20mA DC current DC4 to 20mA Resistance bulb 0 1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 15 16 0 to 150 0 to 400 0 to 1000 0 to 1200 0 to 400 0 to 1600 0 to 1800 0 to 1600 -200 to 400 -200 to 200 -200 to 800 0 to 800 0 to 1300 0 to 1300 1 1 1 1 1 1 0.1/1 1 1 1 0.1 0.1 0.1 0.1/1 -1999 to 9999 (Range where scaling is allowed) 1/1000 digit [2] Unit of temperature: ˚F Input type Resistance bulb Thermocouple Input code Measurement range [˚F] Max. Min. Indication/setting resolution [˚F] Max. Min. DC voltage DC current Pt100Ω J K R B S T E N PLUnusable DC0 to 5V DC1 to 5V DC0 to 10V DC2 to 10V DC0 to 100mV DC0 to 20mA DC4 to 20mA 1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 15 16 32 to 302 32 to 752 32 to 1832 32 to 2192 32 to 752 32 to 3272 32 to 3272 32 to 2912 -328 to 752 -328 to 392 -328 to 1472 32 to 1472 32 to 2372 32 to 2372 -238 to 1562 1 1 1 1 1 1 1 1 1 1 0.1 0.1 0.1 -1999 to 9999 (Range where scaling is allowed) 1/1000 digit * Input a DC current to 1 to 5 V DC or 0 to 5 V DC range via external resistor of 250 Ω. * Input type and ranges are standardly factory set as follows. K: 0 to 400˚C Pt, JPt: 0 to 150˚C Voltage, current: 0 to 100% Standard input type is thermocouple K. 8 OUTLINE DIAGRAM (Unit : mm) Mounting bracket 93 (terminal cover included) 10 48 2 78 91.5 93.7 (terminal cover included) Water-proof packing t Panel 1-12 13-24 25-36 Terminal cover (option) PC loader interface 1 2 3 4 5 6 7 8 9 10 11 12 25 26 27 28 29 30 31 32 33 34 35 36 Terminal screw M3 6.2 Panel cutout size 45 0 +0.8 +0.6 Side stick mounting (n units) (water-proof property is lost in this case) (48 x n-3) 0 +0.8 920 116 MIN. 50 MIN. 92 0 +0.8 Mass about 0.3 kg 107.5 96 9 PXG5 OPTIONALLY ARRANGED ARTICLES Heater current detector (CT) . Specification : 1 to 30 A . Type : CTL-6-S-H 21 15 2.8 . Specification : 20 to 50 A . Type : CTL-12-S36-8F 30 φ2.36 φ5.8 25 7 10.5 2.5 40 9 φ12 30 40 φ3.5 10 30 40 Note 1) Detection is available only for single phase heater. Note 2) Unusable for heater control by thyristor phase angle control. 10 7.5 M3,depth 4 15 EXTERNAL CONNECTION DIAGRAM Standard type with communication OPTION 1 RS485+DI+RSV1 RS485,DI1,RSV1,CT1 RS485+RSV1/RS485+CT1/RS485+DI OUT 2 Output 2 1 RS485 1 RS485 RS485 1 RS485 1 2 DI1 2 DI1 DICOM 2 3 RSV1 CT1 2 3 5 6 Re-Trans (Current) 5 6 Re-Trans (Voltage) 3 4 5 3 4 4 4 DI-COM RSV1 6 5 6 Contact output 5 6 5 6 5 6 Voltage output SSR Drive output Current output 1 2 3 4 5 6 25 26 27 28 29 30 25 26 27 28 DI3 DIOCOM DI4 DI5 OPTION 2 DI3,DI4,DI5,DO4,DO5,CT2,RSV2 25 26 27 28 29 DI3 DIOCOM DI4 DI5 DO4 RSV2 DO5 25 26 27 28 29 30 DI3 DIOCOM DI4 DI5 7 8 9 10 11 12 31 32 33 34 35 36 29 CT2 30 30 OUT 1 Output 1 31 32 Contact output 31 32 SSR Drive output 31 32 Current output 31 32 Voltage output PS Power supply DO DO1COM DO1,DO2,DO3 PV Process value input (Note 1) 7 8 9 10 DOCOM DO1 DO2 DO3 7 8 9 10 33 34 35 36 T.C. 33 34 35 36 R.T.D. 33 34 35 36 DC Voltage (V) 33 34 35 36 DC Voltage (mV) 33 34 35 36 DC Current (mA) 11 12 11 12 DO1 DO2COM DO2 100-240VAC 50/60Hz 24VAC/24VDC 50/60Hz Note 1: Connect the furnished resistor to 33 and 36 . 11 PXG5 Standard type without communication OPTION 1 DI1+DI2+RSV1 DI1 DI-COM DI2 DI1,DI2,RSV1,CT1 DI1+RSV1/DI1+CT1/DI1+DI2 DI1 DICOM OUT 2 DI1 DICOM DI2 Output 2 1 2 3 4 5 1 2 3 DI1 DICOM 1 2 3 1 2 3 4 Re-Trans (Current) Re-Trans (Voltage) 5 6 5 6 RSV1 CT1 4 4 RSV1 6 5 6 Contact output 5 6 SSR Drive output 5 6 Current output 5 6 Voltage output 1 2 3 4 5 6 25 26 27 28 29 30 25 26 27 28 DI3 DIOCOM DI4 DI5 OPTION 2 DI3,DI4,DI5,DO4,DO5,CT2,RSV2 25 26 27 28 29 DI3 DIOCOM DI4 DI5 DO4 RSV2 DO5 25 26 27 28 29 30 DI3 DIOCOM DI4 DI5 7 8 9 10 11 12 31 32 33 34 35 36 29 CT2 30 30 OUT 1 Output 1 31 32 Contact output 31 32 SSR Drive output 31 32 Current output 31 32 Voltage output PS Power supply DO DO1COM DO1, DO2, DO3 PV Process value input (Note 1) 7 8 9 10 DOCOM DO1 DO2 DO3 7 8 9 10 33 34 35 36 T.C. 33 34 35 36 R.T.D. 33 34 35 36 DC Voltage (V) 33 34 35 36 DC Voltage (mV) 33 34 35 36 DC Current (mA) 11 12 11 12 DO1 DO2COM DO2 100-240VAC 50/60Hz 24VAC/24VDC 50/60Hz Note 1: Connect the furnished resistor to 33 and 36 . 12 Motorized valve control type with communication OPTION1 RS485,DI1,DI2,DI3,RSV1 RS485+DI1+DI2+DI3 RS485+DI+RSV1 1 RS485 RS485 1 2 DI1 DICOM DI2 DI3 2 DI1 DICOM RSV1 3 4 5 6 3 4 5 6 PO Control output for motorized valve 25 1 2 3 4 5 6 25 26 27 28 Close 26 COM 27 Open FB Position feedback input 29 30 28 29 30 I IO PFB 7 8 9 10 11 12 31 32 33 34 35 36 DO I Aux contact output 31 32 PS Power supply DO DO1COM DO1 DO1,DO2,DO3 PV Process value input (Note 1) 7 8 9 10 DOCOM DO1 DO2 DO3 7 8 9 10 33 34 35 36 T.C. 33 34 35 36 R.T.D. 33 34 35 36 DC Voltage (V) 33 34 35 36 DC Voltage (mV) 33 34 35 36 DC Current (mA) 11 12 11 12 DO2COM DO2 100-240VAC 50/60Hz 24VAC/24VDC 50/60Hz Note 1: Connect the furnished resistor to 33 and 36 . 13 PXG5 Motorized valve control type without communication OPTION1 DI1,DI2,DI3,RSV1 DI1+DI2+DI3+RSV1 DI1 DICOM DI2 DI3 1 2 3 4 5 RSV1 6 PO Control output for motorized valve 25 Close 26 COM 1 2 3 4 5 6 25 26 27 28 29 30 28 7 8 9 10 11 12 31 32 33 34 35 36 31 32 DO Aux contact output I IO PFB 27 Open FB Position feedback input 29 30 I PS Power supply DO DO1COM DO1,DO2,DO3 PV Process value input (Note 1) 7 8 9 10 DOCOM DO1 DO2 DO3 7 8 9 10 33 34 35 36 T.C. 33 34 35 36 R.T.D. 33 34 35 36 DC Voltage (V) 33 34 35 36 DC Voltage (mV) 33 34 35 36 DC Current (mA) 11 12 11 12 DO1 DO2COM DO2 100-240VAC 50/60Hz 24VAC/24VDC 50/60Hz Note 1: Connect the furnished resistor to 33 and 36 . 14 ISOLATED BLOCK DIAGRAM Power supply Internal Circuit Process value input Valve position feedback signal input Control output 1 (relay contact) or OPEN output Auxiliary analog input (remote SV input) Heater current detector input Control output 2 (relay contact) or CLOSE output Control output 1 (SSR drive, current, voltage) Control output 2 (SSR drive, current, voltage), or auxiliary analog output (re-transmission output) Digital output 1 (relay contact) Digital output 1 to 3 (relay contact) Digital output 2 (relay contact) Communication (RS485) Digital input 1 to 5 Digital output 4, 5 (transistor output) When the 9th digit of the code symbols = J (DO1, 2 independent common) When the 9th digit of the code symbols = Other than J (DO1 to 3 shared common) : Basic insulation (1500 V AC) : Functional insulation (500 V AC) : Non-insulation 15 PXG5
EDS11-159C 价格&库存

很抱歉,暂时无法提供与“EDS11-159C”相匹配的价格&库存,您可以联系我们找货

免费人工找货