PUM Series Multi-loop module type Temperature controller DATA SHEET
EnhancEd communication modulE (cc-link) [Pumcl]
PUMCL
PUMCL is a communication module, which connects module type temperature controller PUM series with CC-Link system. Compatible with CC-Link Ver1.1 and 2.0, and designed for high-speed communication at the maximum speed of 10Mbps. Being able to up to 16 units (64 channel) of PUMA (control module), PUMCL requires minimum wiring, less space, and saves labor for engineering.
FEatuRES
I. Program-less connection to CC-Link 1. CC-Link Ver1.1 / Ver2.0 compatible High-speed communication at max.10Mbps 2. Access to all parameters of control module (PUMA/ PUMB) via CC-Link 3. High-speed data communication with connected control modules (PUMA/PUMB) - Quick data importing and setting data reflection II. User-friendly structure and functions 1. Lateral connection : Max.16 units (64 channels) + event input/output module 16 units = total 32 units Simple wiring for power supply and communication 2. Detachable structure: Terminal block, main unit, and the base part → Easy wiring with detachable terminal blcok → Main units exchangeable without re-wiring
EnhancEd communication modulE (cc-link) SPEciFication
1. General specification
(1) Power supply: 24V DC ±10% (2) Power consumption: Max. 3.2 W (135 mA) [when 24V DC is applied] (3) Insulation resistance: 20MW or more (500V DC) (4) Withstand voltage: Power supply ↔ loader communication 1000V AC 1 min. Power supply ↔ SLD/FG terminal, CC-Link communication 500V AC 1 min. SLD/FG terminal ↔ CC-Link communication 50V AC 1 min. (5) Applied standards: UL, C-UL, RoHS directive [Pending for UL and C-UL]
SYStEm SPEciFication
1. Product type: M ulti-loop module type temperature controller 2. Module type 1) Analog module: Total maximum 16 units a) Control module (4 loop/unit) b) Extended input/output module - Analog input/output module (Input/output 4 points/unit) - Analog input module (Input 4 points/unit) - Analog output module (output 4 points/unit) 2) Extended input/output (digital) module: Maximum 16 units - Event input/output module (Input/output ; 8 points/unit) 3) Enhanced communication module: 1 unit 3. Connecting method: Lateral connecting with connectors - For power supply and RS-485 communication, any one of connected modules is required to be connected. 4. No. of loop, input/output 1) Control loop: Max. 64 2) No.of input / output: DI 128 points / DO 128 points
2. CC-Link communication module 2.1 CC-Link communication
(1) Compliant version: CC-Link Ver.2.00 / 1.10 (2) Station type: Remote device (3) Communication speed and distance
Speed 156kbps 625kbps 900m or less 2.5Mbps 5Mbps 400m or less 200m or less 10Mbps 100m or less Distance 1200m or less
(4) Occupation No. of channel/station: 4 stations/station No.setting; 1 to 61 (5) Commnication data length
No.of occupied stations/extended cyclic 4 stations occupied × 1 4 stations occupied × 2 4 stations occupied × 4 Remote Remote input/output registor (RX/RY) (RWr/RWw) 128 bit 256 bit 512 bit 16 words 32 words 64 words Control module (PUMA/B) No. of connectable units 2 or 4 units 4 or 8 units 8 or 16 units
(6) Connecting cable: Ver1.10 compatible cable for CC-Link (7) Connecting method: M3 screw terminal block (8) Termination resistace: External (110W, 1/2W)
EDS11-166a
Date Apr. 1, 2011
PUMCL
2.2 Display, configuration
Status display LED (2 colors × 2 points + 4 points) (2) Display contents: RUN/FAULT, control module connection status (TX/RX), CC-Link status (L.RUN, L.ERR, SD, RD) (3) Setting device and set contents (1) Display:
Setting device Front Inside Rotary SW × 2 Rotary SW × 1 Set contents CC-Link Station No. setting CC-Link speed setting
(2) Ambient humidity: 90% RH or less (non condensing) (3) Vibration: 10 to 70Hz, 9.8m/s2 (1G) or less
7. Transporting, storage condition (packing condition)
(1) Storage temperature: -20 to 60°C (2) Ambient humidity: 90%RH or less (no condensing) (3) Vibration: 10 to 70Hz, 9.8m/s2 (1G) or less (4) Shock: 294m/s2 (30G) or less
Dip SW (6bit) × 1 CC-Link mode setting
8. Packing list
Temperature controller: 1unit Instruction manual: 1 copy Termination resistor of internal communication: 1 unit
3. Power outage
(1) Impact of power outage: Outage of 2ms or less ; no impact (2) Operation after power outage: Start from the first step (cold start) (3) Memory backup: Nonvolatile memory (EEPROM) No. of update ; 100,000
9. Loader software
(1) Distribution medium: Free download from Fuji Electric Systems HP (http://www.fic-net.jp/eng/index. html) (2) Recommended operating environment PC: DOS/V (PC-AT compatible) OS: Windows XP (operation confirmed in Japanese / English) RAM: 256M bytes or more Free space on the hardware: 500M bytes or more Display resolution: 1024 × 768 or over Serial interface: RS-232C 1 port (without RS-232C, USB serial converter cable required) (3) Connection with PUM Via loader interface on the front face of the module (special cable available from Fuji is required) or via RS-485
4. Self diagnosis
Diagnosis method: Program error monitoring by watch dog timer
5. Structure
(1) Installation method: DIN rail mounting or mounting with M3 screws inside a cabinet (2) Dimensions: 30 (W) × 100 (H) × 85 (D) mm (excluding terminal cover and projected part) (3) Weight: Approx. 200 g (4) Extrenal terminal - CC-Link communication: Detachable terminal block (M3 screw × 20 terminals) - Power supply connection: Terminal block on the base part (M3 screw × 2 terminals) Power is supplied via side connectors in case of lateral connecting. (Max. 33 units) - Loader communication port: 2.5 diameter mini-plug / jack [on the front of the module] (5) Case material: Polyphenylene oxide (flame retardant grade : UL94V-0 equivalent) (6) Case color: Case ; red Terminal, base part ; black (7) Protection - Body: IP20 grade protection (ventilation slits on the top and the bottom of the body) - Terminal: IP00 grade protection, terminal cover is available as an option
codE SYmBolS
[Enhanced communication module]
Digit
12345678 9 10
P UM
YY1
0
Digit Description 4 < Module type > Enhanced communication module 5 < Communication function > CC-Link communication 10 < Operation manual > Japanese English
Digit
C L A B
12345678
[Accessories]
Digit Description 6 DIN rail mounting end plate 7 Side conneting terminal cover (right & left 1 set) 8 Front face screw terminal cover Loader connecting cable (RS-232C)
P UM Z *
A02 A03 A04 L01
[table 1] insulation block diagram
Power Loader communication port
Functional insulation (1000VAC) Functional insulation (500VAC) Functional insulation (50VAC)
6. Normal operating condition
(1) Ambient temperature*: -10 to 50°C * “Ambient temperature” is the temperature underneath the controller inside the equpiment or the cabinet where the controller is installed.
SLD/FG terminal (CC-Link connecting terminal) CC-Link communication
2
outlinE diaGRam (unit : mm)
Front terminal cover (Option)
(10)
Base part (Main unit is detached)
85 Hole for screw mounting
30
Terminal block (at attach/detach)
STATION No. LOADER ×10
×1
1.5
6
100
50 DIN rail Terminal screw M3 (30) Hole for screw mounting Locking tab Main unit (at attach/detach)
6.1
Terminal screw M3
5
At mounting to the DIN rail
Dimensions for screw mounting
2-M3 (30) 9±0.2
(8)
Notice at the installation
Please keep the distance of 30mm from this instrument to radiate. [50mm is recommended]
88.5±0.2
(100)
30 +0.7 +0.2
(3)
30 or more
30 or more
3
PUMCL
tERminal connEction diaGRam
Loader interface plug (RS-232C) 3 TX 2 RX 1 GND
φ2.5 3-pole miniature plug
STATION No. LOADER
×10
×1
DA DB CC-Link DG
21 22 23
21 22 23 24 25 26
11 12 13 14 15 16 17 18 19 20
SLD 24
25
Terminating resistor of internal communication
11 12 13 14
FG
Don’t connect
15 16 17 18 19 20
26
Don’t connect
27 28 29 30
27 28 29 30
Base part
Power DC24V +
1
2
1 3 4
2 5
-
3
4
5
Don’t connect
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice.
Printed in Japan
很抱歉,暂时无法提供与“EDS11-166A”相匹配的价格&库存,您可以联系我们找货
免费人工找货