EDS11-169A

EDS11-169A

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS11-169A - PUM Series Multi-loop module type Temperature controller Analog input/output module[PUM...

  • 数据手册
  • 价格&库存
EDS11-169A 数据手册
PUM Series Multi-loop module type Temperature controller DATA SHEET AnAlog input/output module [pumV/n/t] PUMV/N/T PUMV/N/T is usable Analog I/O module as the accessory I/O of PUM series. Each control module, 30mm wide, is equipped the follows. PUMV is equipped 4 points of analog input/output. PUMN is equipped 4points of analog input. PUMT is equipped 4points of analog output. And all models are equipped high-speed RS-485 port. By connecting with PUM control modules, it realizes a compact and high-performance system. FeAtuReS I. User-friendly structure and functions 1. Lateral connection with control module: Max.16 units (64 channels) + event input/output module 16 units = total 32 units Simple wiring for power supply and communication 2. Detachable structure: Terminal block, main unit, and the base part → Easy wiring with detachable terminal blcok → Main units exchangeable without re-wiring 3. Status LED for each input/output → Easy to detect input status and output status 4. Smart loader communication: Connect one module and all connected modules are able to communicate using a loader software. II. Large scale system using high speed RS-485 1. Modbus RTU protocol for large volume communication 2. High-speed communication: Maximum 115.2kbps 3. Highly-efficient communication: Parameters dispersed on the address map are re-allocated to contiguous address III. Various functions to enhance the control module functions 1. Analog input - Remote SV 2. Analog output - Control output (included distribution output) - Re-transmission output SYStem SpeCiFiCAtion 1. Product type: M ulti-loop module type temperature controller 2. Module type 1) Analog module: Total maximum 16 units a) Control module (4 loop/unit) b) Enhanced input/output (analog) module - Analog input/output module (Input/output 4 points/unit) - Analog input module (Input 4 points/unit) - Analog output module (output 4 points/unit) 2) Enhanced input/output (digital) module: Maximum 16 units - Event input/output module (Input/output ; 8 points/unit) 3) Enhanced communication module: 1 unit 3. Connecting method: Lateral connecting with connectors - For power supply and RS-485 communication, any one of connected modules is required to be connected. 4. No. of loop, input/output 1) Control loop: Max. 64 2) No.of input / output: DI 128 points / DO 128 points EDS11-169a Date Apr. 1, 2011 PUMV/N/T ANALOG I/O MODULE SPECIFICATION 1. General specification (1) Power supply: 24V DC ±10% (2) Power consumption: Max. 3.2 W (135 mA) [when 24V DC is applied] (3) Insulation resistance: 20MΩ or more (500V DC) (4) Withstand voltage: Power supply ↔ all terminals 1000V AC 1 min. Others 500V AC 1 min. (5) Applied standards: UL, C-UL, CE marking, RoHS directive [Pending for UL, C-UL marking] (15) Over range, Under range: Out of range of -5 to 105%FS (Accuracy cannot be ensured for -5 to 0, 100 to 105% FS) (16) Insulation: Functional insulation between channels, and with any other input/output 3. Output (PUMV, PUNT only) (1) No. of output: 4 points (2) Output type: C urrent output (4-20mA DC, 0-20mA DC) - Actual output range: 0mA to 20.6mA DC - Accuracy: ±0.3%FS (less than 1mA : ±5%FS) - Linearity : ±0.3%FS (less than 1mA : ±5%FS) - Resolution: 5,000 or more - Ripple current: P-P 0.3mA or less - Load resistance: 300Ω or less - Insulation: No insulation between outputs Functional insulation other then output (3) Output functions: Output limit, output scaling 2. Input (PUMV, PUMN only) (1) No. of input: 4 points (4 ch) (2) Input setting: Input code selection (3) Input signal: See table 1 Select from group I or II depending on the model code. (setting can be done by points within group) [Group I] a) Thermocouple b) Resistance bulb (3 wire) [Group II] c) DC voltage, current (4) Measurement range and input type: See table 1 (5) Measurement accuracy (Ta = 23°C): - Thermocouple: ±0.3%FS±1digit±1ºC or ±3ºC whichever is greater * Unless B thermocouple 0 to 400ºC :±5%FS±1digit±1ºC R thermocouple 0 to 500ºC :±1%FS±1digit±1ºC T thermocouple -200 to 0ºC :±0.5%FS±1digit±1ºC - Resistance bulb input :±0.3%FS±1digit±1ºC whichever is greater - Voltage/Current input :±0.3%FS±1digit (6) Resolution: See table 1 (7) Temperature fluctuation:±0.3%FS±10ºC (8) Input sampling cycle: 200ms (9) Input impedance: - Thermocouple: 1MΩ or more - Current input: 250 Ω - Voltage input: approx. 1 MΩ (10) Influence of signal source resistance: - Thermocouple: ±0.3%FS±1digit/100Ω - Voltage input: ±0.3%FS±1digit/500Ω (11) Allowable wiring resistance: - Resistance bulb: 10 Ω or less (per wire) (12) Allowable input voltage: - DC voltage input :within ±15V - Current input :within ±25mA - Thermocouple/resistance bulb: within ±5V (13) Noise rejection ratio: - Normal mode : 30dB or more (50/60Hz) - Common mode : 120dB or more (50/60Hz) between process value input and earth, power supply, output 220V AC, 50/60Hz (14) Input compensation: a) User adjustment :zero point, span point ±50%FS b) Input value :±10%FS c) First order lag filter :0.0 to 120.0 sec. 4. Communication function 4.1 RS-485 interface (1) Communication standards: RS-485 compatible (2) No. of port: 1 port (3) Communication, synchro method: Two-wire, half-duplex, asynchronous cycle (4) Communication speed: 9.6k, 19.2k, 38.4k, 115.2kbps (5) Communication distance: 1km (38.4kbps or less), 250m (115.2kbps) (6) Recommended cable: KPEV-SB 0.5sq-equivalent (7) No. of connectable units: 33 units (Master and slave) (32 units if any modules other than PUM series are included in slaves.) (8) Data format: Data bit; 8, parity; even / odd / none (9) Protocol: Modbus RTU compatible (10) Insulation: No insulation with loader communication port Functional insulation with any other input / output 4.2 Loader communication (RS-232C) interface (1) Communication standards: RS-232C compatible (2) No. of port: 1 port (3) Communication, synchro method: Half-duplex, asynchronous cycle (4) Communication speed: 19.2kbps (fixed) (5) Data format: Data bit 8, no parity (6) Protocol: Modbus RTU compatible (7) Connection method: 2.5 diameter mini-plug / jack [on the front of the module] (Common cable with PXG, PXH) (8) Insulation: No insulation with RS-485 communication Functional insulation with any other input / output 2 5. Display, configuration 5.1 Display (1) Display: Status display LED (2 colors × 6 points) (2) Display contents: RUN/FAULT, RS-485 TX/RX, OUT/ERR by loop (4 loops) (Functions are assigned to LED of each channel) (7) Protection - Body: - Terminal: IP20 grade protection (ventilation slits on the top and the bottom of the body) IP00 grade protection, terminal cover is available as an option 9. Normal operating condition (1) Ambient temperature*: -10 to 50°C * “Ambient temperature” is the temperature underneath the controller inside the equpiment or the cabinet where the controller is installed. (2) Ambient humidity: 90% RH or less (non condensing) (3) Vibration: 10 to 70Hz, 9.8m/s2 (1G) or less (4) Warmup time: 30 min. or more 5.2 Setting device (1) Setting device: Rotary SW × 1 (2) Set contents: RS-485 Station No. (Station No.= setting value + 1) 6. Power outage (1) Impact of power outage: Outage of 2ms or less ; no impact (2) Operation after power outage: Start from the first step (cold start) (3) Memory backup: Non volatile memory (EEPROM) No. of update ; 100,000 10. Transporting, storage condition (packing condition) (1) Storage temperature: -20°C to 60°C (2) Ambient humidity: 90%RH or less (no condensing) (3) Vibration: 10 to 70Hz, 9.8m/s2 (1G) or less (4) Shock: 294m/s2 (30G) or less 7. Self diagnosis Diagnosis method: Program error monitoring by watch dog timer 11. Packing list -Temperature controller: 1unit -Instruction manual: 1 copy -250Ω resistance: 0, 2, or 4 (For no. points of voltage/current input selected) 8. Structure (1) Installation method: DIN rail mounting or mounting with M3 screws inside a cabinet (2) Dimensions: 30 (W) × 100 (H) × 85 (D) mm (excluding terminal cover and projected part) (3) Weight: Approx. 200 g (4) Extrenal terminal - Process value input/control output: Detachable terminal block (M3 screw × 20 terminals) - Power supply connection: Terminal block on the base part (M3 screw × 2 terminals) Power is supplied via side connectors in case of lateral connecting. (Max. 33 units) - RS-485 communication connection: Terminal block on the base part (M3 screw × 3 terminals) RS-485 communication is connected via side connectors in case of lateral connecting. - Loader communication port: 2.5 diameter 3 prong mini-plug / jack [on the front of the module] (5) Case material: Polyphenylene oxide (flame retardant grade : UL94V-0 equivalent) (6) Case color: Case ; red Terminal, base part ; black 12. Loader software (1) Distribution medium: Free download from Fuji Electric Systems HP (http://www.fic-net.jp/eng/index. html) (2) Recommended operating environment PC: DOS/V (PC-AT compatible) OS: Windows XP (operating confirmed in Japanese / English) RAM: 256M bytes or more Free space on the hardware: 500M bytes or more Display resolution: 1024 × 768 dots or more Serial interface: RS-232C 1 port (without RS-232C, USB serial converter cable required) (3) Connection with PUM Via loader interface on the front face of the module (special cable available from Fuji is required) or via RS-485 3 PUMV/N/T CODE SYMBOLS [Analog input/ouput module] Digit Digit Description 4 < Module type > Analog I/O module [Ai/Ao 4 points] 5 <Input type> Thermocouple/resistance bulb [all channel] Voltage/current [all channel] Thermocouple/resistance bulb [ch 1, 2], voltage/current [ch3, 4] 10 <Operation manual> Japanease English 12345678 9 10 11 12 13 [Analog input module] Digit Digit Description 4 < Module type > Analog input module[Ai 4 points] 5 <Input type> Thermocouple/resistance bulb [all channel] Voltage/current [all channel] Thermocouple/resistance bulb [ch 1, 2], voltage/current [ch3, 4] 10 <Operation manual> Japanease English 12345678 9 10 11 12 13 P UM EE1 0 000 P UM YY1 0 000 V N T A C T A C A B A B [Accesories (optional)] [Analog output module] Digit Digit Digit Description 4 < Module type > Analog output module[Ao 4 points] 10 <Operation manual> Japanease English 12345678 9 10 11 12 13 12345678 P UM Z * P UM YEE1 0 000 T A B Digit Description 6 RS-485 terminating resistance 7 DIN rail mounting endplate 8 Side connecting terminal cover (right & left 1 set) Fron face screw terminal cover Loader connecting cable (RS-232C) A01 A02 A03 A04 L01 [Table 1] Input type and standard input range Input type Resistance bulb (IEC) Thermocouple Pt100 Input code 2 Measurement range Min. measurement unit [°C] [°C] J K R B S T E N PLDC voltage DC0 to 5V DC1 to 5V DC0 to 10V DC2 to 10V 3 4 5 6 7 8 9 10 11 12 13 14 18 19 21 22 23 24 0 to 150 −150 to 300 −150 to 850 0 to 400 0 to 800 0 to 400 0 to 800 0 to 1200 0 to 1600 0 to 1800 0 to 1600 −199 to 400 −199 to 800 0 to 1300 0 to 1300 −1999 to 9999 (scaling range) 0.1 0.1 1 0.1 0.1 0.1 0.1 1 1 1 1 0.1 0.1 1 1 [Table 2] Insulation block diagram Power Loader communication port RS-485 communication port PV1 PV2 PV3 PV4 OUT1 (Current) OUT2 (Current) OUT3 (Current) OUT4 (Current) Functional insulation (1000V AC) Functional insulation (500V AC) 4 OUTLINE DIAGRAM (Unit : mm) Front terminal cover (Option) (10) 30 Terminal block (at attach/detach) Base part (Main unit is detached) 85 Hole for screw mounting LOADER STATION 1.5 6 100 6.1 Terminal screw M3 Terminal screw M3 5 (30) 50 DIN rail Hole for screw mounting Main unit (at attach/detach) Locking tab At mounting to the DIN rail Dimensions for screw mounting (30) 2-M3 9±0.2 Please keep the distance of 30mm from this instrument to radiate. [50mm is recommended] (8) Notice at the installation (100) 88.5±0.2 (3) 30+0.2 +0.7 30 or more 30 or more 5 PUMV/N/T TERMINAL CONNECTION DIAGRAM (Analog I/O module [PUMV]) Loader interface plug (RS-232C) 3 2 1 TX RX GND φ2.5 3-pole miniature plug LOADER STATION − + Volt./Current* 21 22 23 RTD B B A 21 22 23 Thermocouple − + 21 22 23 INPUT 3 21 22 23 11 12 13 14 15 16 17 18 19 20 OUTPUT 1 Current 11 12 INPUT 1 Thermocouple RTD 13 A B B Volt./Current* 13 14 15 13 − Current 24 25 OUTPUT 3 24 25 + − OUTPUT 2 Current 14 15 + − 14 15 + − + Volt./Current* 26 27 28 RTD B B A 26 27 28 Thermocouple − + 26 27 28 INPUT 4 26 27 28 16 17 INPUT 2 Thermocouple RTD 18 A B B Volt./Current* 18 19 20 18 − Current 29 30 OUTPUT 4 29 30 + − 19 20 + − 19 20 + * In case of current input, attach I/V unit which comes with controller to the voltage input terminal. Base part Power 1 2 1 2 24V DC + − 3 4 5 Communication RS485 3 4 5 A(+) B(−) SG 6 TERMINAL CONNECTION DIAGRAM (Analog input module [PUMN]) Loader interface plug (RS-232C) 3 2 1 TX RX GND φ2.5 3-pole miniature plug LOADER STATION − + Volt./Current* 21 22 23 RTD B B A 21 22 23 Thermocouple − + 21 22 23 INPUT 3 21 22 23 24 25 11 12 13 14 15 16 17 18 19 20 INPUT 2 INPUT 1 Don’t connect 11 12 Thermocouple RTD 13 A B B Volt./Current* 13 14 15 13 + − Don’t connect Don’t connect 24 25 14 15 + − 14 15 − 26 B B RTD − 26 27 28 Thermocouple 26 INPUT 4 26 27 28 29 30 16 17 + Volt./Current* 27 28 + 27 28 A Thermocouple RTD 18 A B B Volt./Current* 18 19 20 18 + − Don’t connect 29 30 19 20 + − 19 20 * In case of currenet input, attach I/V unit which comes with the controller to the voltage input terminal. Base part Power 1 2 1 2 24V DC + − 3 4 5 Communication RS485 3 4 5 A(+) B(−) SG 7 PUME teRminAl ConneCtion diAgRAm (Analog output module [PUMT]) Loader interface plug (RS-232C) 3 2 1 TX RX GND φ2.5 3-pole miniature plug LOADER STATION Don’t connect 21 22 23 21 22 23 OUTPUT 3 24 25 26 27 28 OUTPUT 4 29 30 11 12 13 14 15 16 17 18 19 20 OUTPUT 1 Current + − 11 12 − Current Don’t connect 13 14 15 24 25 + Don’t connect 26 27 28 OUTPUT 2 Current + − 16 17 − Current Don’t connect 18 19 20 29 30 + Base part Power 1 2 1 2 24V DC + − 3 4 5 Communication RS485 3 4 5 A(+) B(−) SG Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDS11-169A 价格&库存

很抱歉,暂时无法提供与“EDS11-169A”相匹配的价格&库存,您可以联系我们找货

免费人工找货