PLATINUM RESISTANCE BULB FOR GENERAL USE
DATA SHEET
These platinum resistance bulbs are convenient for measuring a wide range of temperatures in plants and the like. The resistance element is protected by an internal tube and moreover by an external tube in order to fully with stand high temperature, high pressure and corrosion. A contact strip is inserted between the internal and external protecting tubes, which enables a quick response and ensures high resistance to vibration.
FTF
SPECIFICATIONS
Applicable standard: JIS C 1604—1997 Resistance element: Kind of element and nominal resistance value; Pt100W Class; B class, A class Prescribed current; 2mA Temperature accuracy;
Class A B Accuracy ± (0.15 + 0.002t) °C ± (0.3 + 0.005t) °C
Note: (1) t is measuring temperature indi cated in °C and unrelated to the + and – signs. (2) Accuracy means maximum allowable limit when subtracting the re-sistance value of resistance element from the temperature in terms of resistance calculated according to the standard resistance table.
Protecting tube material: S ; 304 stainless steel W 316 stainless steel ; *T ; 316L stainless steel Mounting method and shape of protecting tube:
Protecting tube shape Mounting method Insertion type A Screw-in type F Screw-in type J Flange type M N P L — G H B C
Mounting method: Insertion type; Either movable flange (FTR), mov able airtight flange (FTT), or movable airtight screw (FTS) is employed for mounting Screw-in type; G3/4 (PT3/4) or R3/4 (PT3/4) external thread (impossible with H type) Flange type; JIS 10K-25A • JIS 20K-25A JIS 30K-25A or JIS 63K-25A (impossible with N or P type) Insertion length: See page 3 Structure of element: 1; Single element 2-wire method (100W B class) 3; Single element 3-wire method (100W B class) 4; Double element 2-wire method (100W B class) 6; Double element 3-wire method (100W B class) 7; Single element 3-wire method (100W A class) 8; Double element 3-wire method (100W A class)
EDS2-21c
Date Jan. 31, 2007
FTF
Feasible combinations of mounting method and ele ment structure:
ABCFGHJLMNP 1, 3 7 4 6, 8 Note: Manufacturing possible Manufacturing possible Flameproof-explosionproof-possible
CODE SYMBOLS
12345678 9 10 11 12 13
FTF 1 3 4
4-
Description
Element Single element 2-wire method (100Ω B class) Single element 3-wire method (100Ω B class) Double element (double winding) 2-wire method (100Ω B class) Double element (double winding) 3-wire method (100Ω B class) Single element 3-wire method (100Ω A class) Double element 3-wire method (100Ω A class) Note:100Ω, 0.5 class is standard.
*6
7 8
Working conditions: See page 4 Terminal box: Material; Diecast aluminum alloy Conduit connection; G1/2 (PF1/2) (JIS 15C) Two conduit connections should be provided with double element 3-wire re-sistance bulb. Coating; Baked melamine resin Finish color; Silver Nominal resistance table: See page 3 Scope of delivery:Platinum resistance bulb
A B C F G H J L M N P S W *T
Mounting method *(1) Insertion type Insertion type Insertion type Screw-in type (for low temperature) Screw-in type (for low temperature) Screw-in type (for low temperature) Screw-in type (for high temperature) Screw-in type (for high temperature) Flange type Flange type Flange type Protecting tube material 304 stainless steel 316 stainless steel 316L stainless steel
Note: *(1) Combination of protecting tube shape and mounting dimension Protecting tube shape Mounting method Insertion type A Screw-in type F Screw-in type J Flange type M N P L — G H B C
1 2 3 4 7 8
0 015
Mounting dimension Flange JIS 10K-25A Flange JIS 20K-25A Flange JIS 30K-25A Flange JIS 63K-25A (impossible with mounting method N or P) Mounting thread G3/4 (PF3/4) Mounting thread R3/4 (PT3/4) (Combination with H type mounting method is excluded) Insertion type Insertion length [mm] Fill in insertion length in cm unit (According to table of insertion lengths) Ex.:Insertion length 500mm 050 1000mm 100
295 A B C F
(a) When the element code No. 6 is used, the terminal box form should be provided with two conduit connections. (b) Feasible combinations of element and mounting method. ABCFGHJLMNP 1, 3 7 4 6, 8 Manufacturing possible Explosionproof structure possible
Structure/Explosionproofing Standard type Plastic terminal type Flameproof type (d2G4) System intrinsically safe explosion proofing (i3nG5) for connection with zener barrier Lining and filling compound *(2) Lining Filling compound None None None Paraffin None Silicon grease Lead homogen None Lead homogen Paraffin Lead homogen Silicon grease Kel-F None Kel-F Paraffin Kel-F Silicon grease
* * * * * *
0 1 2 3 4 5 6 7 8
*(2) Cabtyre cable of 1m lg. is provided when the filling compound is used.
Asterisked (*) items : Non-standard
Insertion length (Unit: mm) [Dimension "L" of "Outline Diagram"]
Mounting method Insertion length A 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 B 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 C 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 1,950 2,450 2,950 F 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 G 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 H 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,400 2,900 J 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 L 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 M 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 N 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 P
Insertion length
200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 2,350 2,850
Nominal resistance value of resistance bulb
JIS C 1604-1997
Temp. [°C] −0 −10 −20 −30 −40 −50 −60 −70 −80 −90 −100
−100 60.26 56.19 52.11 48.00 43.88 39.72 35.54 31.34 27 .10 22.83 18.52
0 100.00 96.09 92.16 88.22 84.27 80.31 76.33 72.33 68.33 64.30 60.26
Temp. [°C] 0 10 20 30 40 50 60 70 80 90 100
0 100.00 103.90 107 .79 111.67 115.54 119.40 123.24 127 .08 130.90 134.71 138.51
100 138.51 142.29 146.07 149.83 153.58 157 .33 161.05 164.77 168.48 172.17 175.86
200 175.86 179.53 183.19 186.84 190.47 194.10 197 .71 201.31 204.90 208.48 212.05
300 212.05 215.61 219.15 222.68 226.21 229.72 233.21 236.70 240.18 243.64 247 .09
400 247 .09 250.53 253.96 257 .38 260.78 264.18 267 .56 270.93 274.29 277 .64 280.98
500 280.98 284.30 287 .62 290.92 294.21 297 .49 300.75 304.01 307 .25 310.49 313.71
600 313.71 316.92 320.12 323.30 326.48 329.64
Temp. [°C] 0 10 20 30 40 50 60 70 80 90 100
Remarks: The resistance values given in the above table are those when nominal resistance value "R 0" is 100W. (Unit: W)
FTF
Working conditions
Model 1 3 S 4 FTF AW 6 T 7 8 S 1 FTF 3 B W T 7 S 1 FTF 3 C W T 7 1 3 S 4F FTF W J 6 T 7 8 S 1 G FTF 3 L W T 7
5 4 MPa
Working temperature, working pressure Working temp.; –200 to +650 °C Working pressure; Atmospheric pressure When both movable airtight screw and flange are used, working pressure can be up to 0.1MPa {1.02kgf/cm2}
Application
Mass{weight}
Outline diagrams Fig. 1 Fig. 2
(
)
Used for corrosive gas or liquid, 0.5 to 2 kg and when the insertion length is desired to be adjustable
Ditto
Ditto Used when especially short time lag is required Ditto Used when greater insertion length is required Used for corrosive gas or liquid. Used for comparatively high temp., high pressure. J type is used when the temp. in the terminal box is expected to rise or when there is heatretaining material
0.5 to 1.5 kg
Fig. 3
Ditto
0.7 to 4.4 kg
Fig. 4
0.5 to 1.8 kg
Fig. 5 Fig. 6 Fig. 7 Fig. 8
0 -200 3.5 3 MPa
100
500°C
0 -200
100
500°C
Used for corrosive gas or liquid. 0.5 to 1.5 kg L type is used when the temp. in the terminal box is expected to rise or when there is heatretaining material, or used when especially short time lag is required Used for water, air, corrosive gas etc., and especially in case greater insertion length is required Used for corrosive gas or liquid etc., and especially in case airtightness is required 1 to 3 kg
Fig. 9 Fig. 10
MPa
S 1 FTF 3 H W T 7 1 3 S 4 FTF HW 6 T 7 8 S 1 FTF 3 N W T 7
2 1.5 0 -200 500°C
Fig. 11
100
Working temp.; –200 to +650 °C Working pressure; Less than flange (JIS) nominal pressure JIS 10K-25 • JIS 20K-25 JIS 30K-25 • JIS 63K-25 Material; 04, 316, 3 316L stainless steel Working temp.; –200 to +650 °C Working pressure; Less than flange (JIS) nominal pressure JIS 10K-25 • JIS 20K-25 JIS 30K-25 Material; 04, 316, 3 316L stainless steel Ditto
1.4 to 3.8 kg
Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21
Ditto Used when especially short time lag is required
1.4 to 3.8 kg
S 1 FTF 3 P W T 7
Ditto Used when especially long insertion length is required
1.2 to 6.3 kg
Fig. 22 Fig. 23 Fig. 24
Note: When the resistance bulb is used at a place of low temperature (below 0 °C) or of high temperature, use a bulb which is filled internally with paraffin or silicon compound after connecting the cable. Paraffin can be used in a range of 0 to 50 °C and silicon in a range of – 60 to + 150 °C.
OUTLINE DIAGRAM
[Unit:mm] (Refer to working conditions of page 4)
Determine insertion length "L" by collating the 5th digit of code symbols with the table shown on page 3. For example, when the 5th digit of code symbol is A, select "L" from 22 lengths, 150mm to 1450mm, by the table shown on page 3.
Screw-in type
Dimension "A" on the neck part of screw-in type is as follows.
5th digit of code symbols F , G J, L A 50mm 150mm
Insertion type
Fig. 5
1 S A 3 FTF 4 A W 04 - ••• F T 7
1 S 3F A W 74 - ••• FTF 4 F J T 7
Fig. 1
Fig. 6
1 S 3F A W 84 - ••• FTF 4 F J T 7
Fig. 2
S 6 A FTF 8 A W 04 - ••• F T
Fig. 7 Fig. 3
1 S A FTF 3 B W 04 - ••• F 7 T
S 6F A W 74 - ••• FTF 8 F J T
Fig. 4
1 S A FTF 3 C W 04 - ••• F 7 T
Fig. 8
S 6F A W 84 - ••• FTF 8 F J T
FTF
Flange type
Fig. 9
S 1 A G W 74 - ••• FTF 3 F L T 7
Fig. 12
1 S A 3 FTF 4 M W 14 - ••• F T 7
Fig. 10
S 1 A G W 84 - ••• FTF 3 F L T 7
Fig. 13
1 S A 3 FTF M W 24 - ••• F 4 T 7
Fig. 11
1 S A FTF 3 H W 74 - ••• F 7 T
Fig. 14
1 S A 3 FTF M W 34 - ••• F 4 T 7
Fig. 15
1 S A 3 FTF 4 M W 44 - ••• F T 7
Fig. 16
S 6 A FTF 8 M W 14 - ••• F T
Fig. 20
1 S A FTF 3 N W 24 - ••• F 7 T
Fig. 17
S 6 A FTF 8 M W 24 - ••• F T
Fig. 21
1 S A FTF 3 N W 34 - ••• F 7 T
Fig. 18
S 6 A FTF 8 M W 34 - ••• F T
Fig. 22
1 S A FTF 3 P W 14 - ••• F 7 T
Fig. 19
1 S A FTF 3 N W 14 - ••• F 7 T
Fig. 23
1 S A FTF 3 P W 24 - ••• F 7 T
FTF
Terminal box for flameproof type
125
100 G1/2 (PF1/2)
Cap
Fig. 24
1 S A FTF 3 P W 34 - ••• F 7 T
Movable airtight screw (type FTS)
2, 4, 6 in 4th digit of code
Type
φd1
φd2
a
b 30 30 20 20
Protecting tube Approx. ℓ outer dia. (φD) 100 100 80 80 30 25 to 27 21.3 to 22 12
Mass {weight} [kg] 1.2 1.2 0.8 0.8
FTS6E 31 FTS6D 28 FTS4C 24 FTS2A 13
R1 1/4 58 (PT1 1/4) R1 1/4 58 (PT1 1/4) R1 (PT1) 50 R3/4 (PT3/4) 38
Note: Material is SS400
1, 3, 5 in 4th digit of code
Type
φd1
φd2
φa
b 58 58 50 38
c 30 30 20 20
Protecting Mass Approx. ℓ tube outer {weight} dia. (φD) [kg] 100 100 80 80 30 25 to 27 21.3 to 22 12 1.2 1.2 0.8 0.8
FTS5E 31 FTS5D 28 FTS3C 24 FTS1A 13
G1 1/4 69 (PF1 1/4) G1 1/4 69 (PF1 1/4) G1 (PF1) 59 G3/4 (PF3/4) 48
Note: Material is SS400
Movable airtight flange (type FTT)
JIS 10K-50 flange
Movable flange (type FTR)
JIS 10K-50 flange
φd 31 28 24
Protecting tube outer dia. (φD) 30 26.8• 27 21.3 • 21.7 • 22
φd Material SS400 50 31 28 24 13
Protecting tube outer dia. (φD) 49 30 25 to 27 21.3 to 22 12
Material
SS400
JIS 10K-25 flange
JIS 10K-25 flange
Type FTT2D FTT2C FTT2A
φd 28 24 13
Protecting tube outer dia. (φD) 26.8 • 27 21.3 • 21.7 • 22 12
Material FC200 Type FTR2D FTR2C FTR2A φd 28 24 13 Protecting tube outer dia. (φD) 25 to 27 21.3 to 22 12 FC200 Material
JIS 5K-25 flange
JIS 5K-25 flange
Type FTT1D FTT1C FTT1A
φd 28 24 13
Protecting tube outer dia. (φD) 26.8 • 27 21.3 • 21.7 • 22 12
Type Material FC200 FTR1D FTR1C FTR1A
φd 28 24 13
Protecting tube outer dia. (φD) 25 to 27 21.3 to 22 12
Material FC200
FTF
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng
Instrumentation Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.