0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS2-21C

EDS2-21C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS2-21C - PLATINUM RESISTANCE BULB FOR GENERAL USE - Fuji Electric

  • 数据手册
  • 价格&库存
EDS2-21C 数据手册
PLATINUM RESISTANCE BULB FOR GENERAL USE DATA SHEET These platinum resistance bulbs are convenient for measuring a wide range of temperatures in plants and the like. The resistance element is protected by an internal tube and moreover by an external tube in order to fully with stand high temperature, high pressure and corrosion. A contact strip is inserted between the internal and external protecting tubes, which enables a quick response and ensures high resistance to vibration. FTF SPECIFICATIONS Applicable standard: JIS C 1604—1997 Resistance element: Kind of element and nominal resistance value; Pt100W Class; B class, A class Prescribed current; 2mA Temperature accuracy; Class A B Accuracy ± (0.15 + 0.002t) °C ± (0.3 + 0.005t) °C Note: (1) t is measuring temperature indi cated in °C and unrelated to the + and – signs. (2) Accuracy means maximum allowable limit when subtracting the re-sistance value of resistance element from the temperature in terms of resistance calculated according to the standard resistance table. Protecting tube material: S ; 304 stainless steel W 316 stainless steel ; *T ; 316L stainless steel Mounting method and shape of protecting tube: Protecting tube shape Mounting method Insertion type A Screw-in type F Screw-in type J Flange type M N P L — G H B C Mounting method: Insertion type; Either movable flange (FTR), mov able airtight flange (FTT), or movable airtight screw (FTS) is employed for mounting Screw-in type; G3/4 (PT3/4) or R3/4 (PT3/4) external thread (impossible with H type) Flange type; JIS 10K-25A • JIS 20K-25A JIS 30K-25A or JIS 63K-25A (impossible with N or P type) Insertion length: See page 3 Structure of element: 1; Single element 2-wire method (100W B class) 3; Single element 3-wire method (100W B class) 4; Double element 2-wire method (100W B class) 6; Double element 3-wire method (100W B class) 7; Single element 3-wire method (100W A class) 8; Double element 3-wire method (100W A class) EDS2-21c Date Jan. 31, 2007 FTF Feasible combinations of mounting method and ele ment structure: ABCFGHJLMNP 1, 3 7 4 6, 8 Note: Manufacturing possible Manufacturing possible Flameproof-explosionproof-possible CODE SYMBOLS 12345678 9 10 11 12 13 FTF 1 3 4 4- Description Element Single element 2-wire method (100Ω B class) Single element 3-wire method (100Ω B class) Double element (double winding) 2-wire method (100Ω B class) Double element (double winding) 3-wire method (100Ω B class) Single element 3-wire method (100Ω A class) Double element 3-wire method (100Ω A class) Note:100Ω, 0.5 class is standard. *6 7 8 Working conditions: See page 4 Terminal box: Material; Diecast aluminum alloy Conduit connection; G1/2 (PF1/2) (JIS 15C) Two conduit connections should be provided with double element 3-wire re-sistance bulb. Coating; Baked melamine resin Finish color; Silver Nominal resistance table: See page 3 Scope of delivery:Platinum resistance bulb A B C F G H J L M N P S W *T Mounting method *(1) Insertion type Insertion type Insertion type Screw-in type (for low temperature) Screw-in type (for low temperature) Screw-in type (for low temperature) Screw-in type (for high temperature) Screw-in type (for high temperature) Flange type Flange type Flange type Protecting tube material 304 stainless steel 316 stainless steel 316L stainless steel Note: *(1) Combination of protecting tube shape and mounting dimension Protecting tube shape Mounting method Insertion type A Screw-in type F Screw-in type J Flange type M N P L — G H B C 1 2 3 4 7 8 0 015 Mounting dimension Flange JIS 10K-25A Flange JIS 20K-25A Flange JIS 30K-25A Flange JIS 63K-25A (impossible with mounting method N or P) Mounting thread G3/4 (PF3/4) Mounting thread R3/4 (PT3/4) (Combination with H type mounting method is excluded) Insertion type Insertion length [mm] Fill in insertion length in cm unit (According to table of insertion lengths) Ex.:Insertion length 500mm 050 1000mm 100 295 A B C F (a) When the element code No. 6 is used, the terminal box form should be provided with two conduit connections. (b) Feasible combinations of element and mounting method. ABCFGHJLMNP 1, 3 7 4 6, 8 Manufacturing possible Explosionproof structure possible Structure/Explosionproofing Standard type Plastic terminal type Flameproof type (d2G4) System intrinsically safe explosion proofing (i3nG5) for connection with zener barrier Lining and filling compound *(2) Lining Filling compound None None None Paraffin None Silicon grease Lead homogen None Lead homogen Paraffin Lead homogen Silicon grease Kel-F None Kel-F Paraffin Kel-F Silicon grease * * * * * * 0 1 2 3 4 5 6 7 8 *(2) Cabtyre cable of 1m lg. is provided when the filling compound is used. Asterisked (*) items : Non-standard  Insertion length (Unit: mm) [Dimension "L" of "Outline Diagram"] Mounting method Insertion length A 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 B 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 C 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 1,950 2,450 2,950 F 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 G 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 H 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,400 2,900 J 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 L 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 M 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 N 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 P Insertion length 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 2,350 2,850 Nominal resistance value of resistance bulb JIS C 1604-1997 Temp. [°C] −0 −10 −20 −30 −40 −50 −60 −70 −80 −90 −100 −100 60.26 56.19 52.11 48.00 43.88 39.72 35.54 31.34 27 .10 22.83 18.52 0 100.00 96.09 92.16 88.22 84.27 80.31 76.33 72.33 68.33 64.30 60.26 Temp. [°C] 0 10 20 30 40 50 60 70 80 90 100 0 100.00 103.90 107 .79 111.67 115.54 119.40 123.24 127 .08 130.90 134.71 138.51 100 138.51 142.29 146.07 149.83 153.58 157 .33 161.05 164.77 168.48 172.17 175.86 200 175.86 179.53 183.19 186.84 190.47 194.10 197 .71 201.31 204.90 208.48 212.05 300 212.05 215.61 219.15 222.68 226.21 229.72 233.21 236.70 240.18 243.64 247 .09 400 247 .09 250.53 253.96 257 .38 260.78 264.18 267 .56 270.93 274.29 277 .64 280.98 500 280.98 284.30 287 .62 290.92 294.21 297 .49 300.75 304.01 307 .25 310.49 313.71 600 313.71 316.92 320.12 323.30 326.48 329.64 Temp. [°C] 0 10 20 30 40 50 60 70 80 90 100 Remarks: The resistance values given in the above table are those when nominal resistance value "R 0" is 100W. (Unit: W)  FTF Working conditions Model 1 3 S 4 FTF AW 6 T 7 8 S 1 FTF 3 B W T 7 S 1 FTF 3 C W T 7 1 3 S 4F FTF W J 6 T 7 8 S 1 G FTF 3 L W T 7 5 4 MPa Working temperature, working pressure Working temp.; –200 to +650 °C Working pressure; Atmospheric pressure When both movable airtight screw and flange are used, working pressure can be up to 0.1MPa {1.02kgf/cm2} Application Mass{weight} Outline diagrams Fig. 1 Fig. 2 ( ) Used for corrosive gas or liquid, 0.5 to 2 kg and when the insertion length is desired to be adjustable Ditto Ditto Used when especially short time lag is required Ditto Used when greater insertion length is required Used for corrosive gas or liquid. Used for comparatively high temp., high pressure. J type is used when the temp. in the terminal box is expected to rise or when there is heatretaining material 0.5 to 1.5 kg Fig. 3 Ditto 0.7 to 4.4 kg Fig. 4 0.5 to 1.8 kg Fig. 5 Fig. 6 Fig. 7 Fig. 8 0 -200 3.5 3 MPa 100 500°C 0 -200 100 500°C Used for corrosive gas or liquid. 0.5 to 1.5 kg L type is used when the temp. in the terminal box is expected to rise or when there is heatretaining material, or used when especially short time lag is required Used for water, air, corrosive gas etc., and especially in case greater insertion length is required Used for corrosive gas or liquid etc., and especially in case airtightness is required 1 to 3 kg Fig. 9 Fig. 10 MPa S 1 FTF 3 H W T 7 1 3 S 4 FTF HW 6 T 7 8 S 1 FTF 3 N W T 7 2 1.5 0 -200 500°C Fig. 11 100 Working temp.; –200 to +650 °C Working pressure; Less than flange (JIS) nominal pressure JIS 10K-25 • JIS 20K-25 JIS 30K-25 • JIS 63K-25 Material; 04, 316, 3 316L stainless steel Working temp.; –200 to +650 °C Working pressure; Less than flange (JIS) nominal pressure JIS 10K-25 • JIS 20K-25 JIS 30K-25 Material; 04, 316, 3 316L stainless steel Ditto 1.4 to 3.8 kg Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Ditto Used when especially short time lag is required 1.4 to 3.8 kg S 1 FTF 3 P W T 7 Ditto Used when especially long insertion length is required 1.2 to 6.3 kg Fig. 22 Fig. 23 Fig. 24 Note: When the resistance bulb is used at a place of low temperature (below 0 °C) or of high temperature, use a bulb which is filled internally with paraffin or silicon compound after connecting the cable. Paraffin can be used in a range of 0 to 50 °C and silicon in a range of – 60 to + 150 °C.  OUTLINE DIAGRAM [Unit:mm] (Refer to working conditions of page 4) Determine insertion length "L" by collating the 5th digit of code symbols with the table shown on page 3. For example, when the 5th digit of code symbol is A, select "L" from 22 lengths, 150mm to 1450mm, by the table shown on page 3. Screw-in type Dimension "A" on the neck part of screw-in type is as follows. 5th digit of code symbols F , G J, L A 50mm 150mm Insertion type Fig. 5 1 S A 3 FTF 4 A W 04 - ••• F T 7 1 S 3F A W 74 - ••• FTF 4 F J T 7 Fig. 1 Fig. 6 1 S 3F A W 84 - ••• FTF 4 F J T 7 Fig. 2 S 6 A FTF 8 A W 04 - ••• F T Fig. 7 Fig. 3 1 S A FTF 3 B W 04 - ••• F 7 T S 6F A W 74 - ••• FTF 8 F J T Fig. 4 1 S A FTF 3 C W 04 - ••• F 7 T Fig. 8 S 6F A W 84 - ••• FTF 8 F J T  FTF Flange type Fig. 9 S 1 A G W 74 - ••• FTF 3 F L T 7 Fig. 12 1 S A 3 FTF 4 M W 14 - ••• F T 7 Fig. 10 S 1 A G W 84 - ••• FTF 3 F L T 7 Fig. 13 1 S A 3 FTF M W 24 - ••• F 4 T 7 Fig. 11 1 S A FTF 3 H W 74 - ••• F 7 T Fig. 14 1 S A 3 FTF M W 34 - ••• F 4 T 7 Fig. 15 1 S A 3 FTF 4 M W 44 - ••• F T 7  Fig. 16 S 6 A FTF 8 M W 14 - ••• F T Fig. 20 1 S A FTF 3 N W 24 - ••• F 7 T Fig. 17 S 6 A FTF 8 M W 24 - ••• F T Fig. 21 1 S A FTF 3 N W 34 - ••• F 7 T Fig. 18 S 6 A FTF 8 M W 34 - ••• F T Fig. 22 1 S A FTF 3 P W 14 - ••• F 7 T Fig. 19 1 S A FTF 3 N W 14 - ••• F 7 T Fig. 23 1 S A FTF 3 P W 24 - ••• F 7 T  FTF Terminal box for flameproof type 125 100 G1/2 (PF1/2) Cap Fig. 24 1 S A FTF 3 P W 34 - ••• F 7 T Movable airtight screw (type FTS) 2, 4, 6 in 4th digit of code Type φd1 φd2 a b 30 30 20 20 Protecting tube Approx. ℓ outer dia. (φD) 100 100 80 80 30 25 to 27 21.3 to 22 12 Mass {weight} [kg] 1.2 1.2 0.8 0.8 FTS6E 31 FTS6D 28 FTS4C 24 FTS2A 13 R1 1/4 58 (PT1 1/4) R1 1/4 58 (PT1 1/4) R1 (PT1) 50 R3/4 (PT3/4) 38 Note: Material is SS400 1, 3, 5 in 4th digit of code Type φd1 φd2 φa b 58 58 50 38 c 30 30 20 20 Protecting Mass Approx. ℓ tube outer {weight} dia. (φD) [kg] 100 100 80 80 30 25 to 27 21.3 to 22 12 1.2 1.2 0.8 0.8 FTS5E 31 FTS5D 28 FTS3C 24 FTS1A 13 G1 1/4 69 (PF1 1/4) G1 1/4 69 (PF1 1/4) G1 (PF1) 59 G3/4 (PF3/4) 48 Note: Material is SS400  Movable airtight flange (type FTT) JIS 10K-50 flange Movable flange (type FTR) JIS 10K-50 flange φd 31 28 24 Protecting tube outer dia. (φD) 30 26.8• 27 21.3 • 21.7 • 22 φd Material SS400 50 31 28 24 13 Protecting tube outer dia. (φD) 49 30 25 to 27 21.3 to 22 12 Material SS400 JIS 10K-25 flange JIS 10K-25 flange Type FTT2D FTT2C FTT2A φd 28 24 13 Protecting tube outer dia. (φD) 26.8 • 27 21.3 • 21.7 • 22 12 Material FC200 Type FTR2D FTR2C FTR2A φd 28 24 13 Protecting tube outer dia. (φD) 25 to 27 21.3 to 22 12 FC200 Material JIS 5K-25 flange JIS 5K-25 flange Type FTT1D FTT1C FTT1A φd 28 24 13 Protecting tube outer dia. (φD) 26.8 • 27 21.3 • 21.7 • 22 12 Type Material FC200 FTR1D FTR1C FTR1A φd 28 24 13 Protecting tube outer dia. (φD) 25 to 27 21.3 to 22 12 Material FC200  FTF Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS2-21C 价格&库存

很抱歉,暂时无法提供与“EDS2-21C”相匹配的价格&库存,您可以联系我们找货

免费人工找货