EDS3-111E

EDS3-111E

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS3-111E - NDIR TYPE INFRARED GAS ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS3-111E 数据手册
NDIR TYPE INFRARED GAS ANALYZER DATA SHEET This NDIR gas analyzer is used for measuring CO2, CO, SO2 and CH4 and features a high accuracy, multiple functions and easy operation through use of a microprocessor. It is housed in an easy-to-use horizontal case (can be flush mounted on panel, mounted on 19 inch rack, placed on table top), or vertical case (can be flush mounted on panel, mounted on wall). The analyzer provides a performance superior to the conventional double-beam system, is easy to maintain, and offers an excellent long-term stability. It is thus optimum for continuous measurement in the combustion control of various industrial furnaces, in research on garden-plants, and so on. ZRH FEATURES 1. The use of a microprocessor provides high accuracy, multiple functions and easy operation. • Zero and span calibration is accurate and easy just by pressing the calibrating keys. • A self-diagnosis function is included. • An automatic calibrating function can be provided as an option. • Range can be changed over by a external signal as an option. 2. An improved optical system provides long term stability, and there is a minimum of drift caused by contamination of the measuring cell, so the long-term stability is excellent. 3. Adopting a serial dual-layer type of transmission detector minimizes remarkable the interface from other gas components. 4. Easy maintenance. The single-beam photometric system uses a sample cell only and eliminates the necessity of delicate adjustment for optical balance. The instrument is designed as a unit of simple construction featuring easy maintenance and checks. SPECIFICATIONS Measurable gas components: Single-component CO 2 CO, SO2, CH4 Dual-component CO2/CO: Landfill garbage application CO2: 0 to 50% CH 4: 0 to 80% Measuring range: Refer to measurable range combination table (page 5). Measuring system: Non-dispersion infrared-ray absorption method, deviation method, single light source – single beam Output signal: Output 1; 0 to 1V DC Output 2; 4 to 20mA DC (optional allowable load resistance 550Ω or less). Repeatability: 1st range (low range) Within ± 0.5% of full scale 2nd range (high range) Within ± 1% of full scale Linearity: ± 2% of full scale Zero drift: Within ± 2% of full scale/week Span drift: Within ± 2% of full scale/week Response time: Within 15 seconds max. (for 90% response) depending on cell length Power supply: 100V, 115V, 220V or 240V ± 10% AC, 50/ 60Hz Power consumption: 37VA max. EDS3-111e Date Nov. 24, 2004 ZRH Ambient temperature: –5 to +45°C Ambient humidity: 90% RH or less Enclosure: Steel casing, for indoor use Storage condition: Temperature; –20 to +60°C Humidity; 100% RH max. (free from condensation) Outer dimensions (H x W x D): (1) Horizontal case Rack mounting type; 133 x 483 x 435 mm Panel flush mounting type; 133 x 443 x 435 mm Table-top type; 145 x 443 x 435 mm (2) Vertical case Panel flush mounting type; 440 x 294 x 178 mm Wall mounting type; 484 x 294 x 178 mm Mass weight: Approx. 12Kg Finish color: Munsell 2.5Y8.4/1.2 Display: 4 digit LED for concentration display 4 digit LED for sub-display Output hold: Output value before manual or automatic calibration is hold. Whether or not to effect hold function can be selected. Sample gas condition: Temperature; 0 to 50°C Dust; less than 0.3 µm Pressure; less than 10 kPa Standard adjustment gas: Dry N2 Balance Warm up time: Approx. 2 hours Material of gas-contacting parts: Sample cell, SUS304, neoprene rubber Infrared-ray transmitting window; CaF2 or sapphire Internal tubing; Toaron tube Gas inlet/outlet, purge gas inlet size: Rc1/4 (PT1/4 internal thread) or NPT1/4 internal thread Measured gas flow rate: 1 ± 0.5 liter/minutes Purge gas flow rate: Approx. 1 liter/minute Scope of delivery:Analyzer, power fuse, manual, mounting bracket in the case of panel mounting type Mounting method: (1) Horizontal case Mounted on 19 inch rack, or on panel, or on table-top Installation conditions: Install the analyzer at a place not exposed to direct sunlight or the radiation from a high temperature object. A void vibration, and select a clean place free of corrosive and/or combustible gases. If installing outdoors, provide a suitable casing or cover to protect the analyzer from wind, rain, etc. Optional specifications Remote output hold: Analog output (DC0-1V, 4-20mA) is held via external signal. Input signal: 5V DC Remote range changeover: Range is changeable via external signal. Range changeover input signal: 5V DC Range identification signal output: Contact output; 1 a contact Contact capacity; 250V AC, 2A (resistive load) Automatic calibration: Zero and span are automatically calibrated at the preset cycle. Calibration gas is supplied sequentially by driving an electromagnetic value installed outside. Calibration channel: Up to 2 components can be calibrated simultaneously. Zero calibration point: Fixed at 0% Span calibration point: 50 to 100% full scale Calibration start: Via built-in timer or remote start signal Output hold at calibration: Possible Calibration gas flow mode: (1) Zero gas (2) Zero gas – span gas 1 (3) Zero gas – span gas 2 (4) Zero gas – span gas 1 – span gas 2 Calibration gas flow time: Settable from 100 to 599 sec. Calibration cycle: 1 to 199 hours (in 1-hour step) Calibration failure alarm: Provided when fault occurs during auto calibration. Contact output: During calibration; 1 a (N.O) contact, contact capacity 250V AC, 2A (resistive load) Calibration failure; 1 a (N.O) contact, contact capacity 250V AC, 2A (resistive load) Electromagnetic valve drive; 1 a (N.O) contact, contact capacity 250V AC, 2A (resistive load) Remote start: Remote start signal; voltage input 5V DC approx. 250mm 90° Support Remark: 70% or more of the analyzer weight should be supported at the bottom of the case. (In case of mounting panel or 19 inch rack, provide a support at the rear of casing.) (2) Vertical case Flush mounted on panel or mounted on wall or 90° 90° 2 CODE SYMBOLS (1) Single-component analyzer 12345678 9 10 11 12 13 14 15 16 17 18 Z RH 1 3 A B D E E F G U H J K Q L M N W P X R Z Y2 - A - Y Y- Description No. of measurable components Single component Horizontal case Single component Vertical case Measurable component SO2 CO CO2 CH4 Measuring range (1st range) (Note 1) 0 to 500 ppm 0 to 1000 ppm 0 to 2000 ppm 0 to 2500 ppm 0 to 5000 ppm 0 to 1% 0 to 2% 0 to 3% 0 to 5% 0 to 10% 0 to 20% 0 to 40% 0 to 50% 0 to 70% 0 to 100% Others 0 1 2 3 4 5 6 7 8 9 A B C D A Y A Y A Power supply, Piping connection 100V AC 50Hz Rc 1/4 100V AC 60Hz Rc 1/4 115V AC 60Hz Rc 1/4 220V AC 50Hz Rc 1/4 100V AC 50Hz NPT 1/4 100V AC 60Hz NPT 1/4 115V AC 60Hz NPT 1/4 220V AC 50Hz NPT 1/4 240V AC 50Hz NPT 1/4 240V AC 50Hz Rc 1/4 Structure Table top type (For horizontal case only) 19 inch rack mounting type (For horizontal case only) Panel mounting type Wall mounting type Output signal (Output 1/2) (Notes 2, 3) 0 to 1V DC /4 to 20mA DC Optional function (1) None With auto-calibration Optional function (2) None With remote range, range identification and remote output hold Y F G U H J K L M N P R Z A B Z Y Z Measuring range (2nd range) (Note 1) None 0 to 1000 ppm 0 to 2000 ppm 0 to 2500 ppm 0 to 5000 ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% Others Adjustment gas Standard for carburizing furnace Others (Note 4) Paint Fuji standard Non standard specifications Non standard Notes : (1) Refer to measurable range combined table (2) Output signal are provided simultaneously (3) 0 to 100mV, 0 to 10mV DC is available on request (4) To be adviced components of sample gas 3 ZRH (2) Dual-component analyzer 12345678 9 10 11 12 13 14 15 16 17 18 12345678 9 10 11 12 13 14 15 16 17 18 Z RH G 2- A - - Description No. of measurable components Dual component Horizontal case Dual component Vertical case Z RH G 2- A - - Description Measuring range (1st comp. 2nd range) None 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% Others Measuring range (2nd comp. 2nd range) None 0 to 1000 ppm 0 to 2000 ppm 0 to 5000 ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 25% 0 to 50% 0 to 100% Others 2 4 G Measurable component CO2/CO Measuring range (1st comp. 1st range) Note (5, 6) 0 to 5000 ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% Others Measuring range (2nd comp. 1st range) Note (5, 6) 0 to 500 ppm 0 to 1000 ppm 0 to 2000 ppm 0 to 5000 ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 25% 0 to 50% 0 to 100% Others Power supply, Piping connection 100V AC 50Hz Rc 1/4 100V AC 60Hz Rc 1/4 115V AC 60Hz Rc 1/4 220V AC 50Hz Rc 1/4 100V AC 50Hz NPT 1/4 100V AC 60Hz NPT 1/4 115V AC 60Hz NPT 1/4 220V AC 50Hz NPT 1/4 240V AC 50Hz NPT 1/4 240V AC 50Hz Rc 1/4 A B C D Structure Table top type 19 inch rack mounting type Panel mounting type Wall mounting type Output signal (Output 1/2) (Notes 2, 3) 0 to 1V/DC 4 to 20mA DC Y A Y A Optional function (1) None With auto-calibration Optional function (2) None With remote range, range identification and remote output hold Y J K L M N P R Z H J K L M N P R Z E F G H J K L M N V P R Z Y F G H J K L M N V P R Z A B Z Y Adjustment gas Standard for carburizing furnace Others Paint Fuji standard Non standard specifications Non standard Z 0 1 2 3 4 5 6 7 8 9 The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TZ734576. The applicable standards used to demonstrate compliance are : EN 50081-1 : 1991 CLASS A Conducted and Radiated emissions EN 50082-1 : 1992 Radiated immunity, ESD and FBT Note: Available for ZRH1, 2 A Note (5) Refer to measurable range combination table (6) 1st comp. is CO2, 2nd comp. is CO. 4 Measurable range combination table (1) Single-component (CO2• CO• CH4) 1st E F G U H J K Q L M N W P X R G U 2nd range F range 0 to 1000 ppm 0 to 2000 ppm 0 to 2500 ppm 0 to 500 ppm — 0 to 1000 ppm — — 0 to 2000 ppm — — — 0 to 2500 ppm — — — 0 to 5000 ppm — — — 0 to 1% — — — 0 to 2% — — — 0 to 3% — — — 0 to 5% — — — 0 to 10% — — — 0 to 20% — — — 0 to 40% — — — 0 to 50% — — — 0 to 70% — — — 0 to 100% H 0 to 5000 ppm J 0 to 1% K 0 to 2% L 0 to 5% M 0 to 10% N 0 to 20% P 0 to 50% R 0 to 100% — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — :CO2 :CO : CH4 :SO2 —: Impossible * Also single range is possible (2) Dual-components (CO2/CO) 2nd component 1st range E F G H 1st component 0 to 500ppm 0 to 1000ppm 0 to 2000ppm 0 to 5000ppm 1st range CO J 0 to 1% K 0 to 2% L 0 to 5% M 0 to 10% N 0 to 20% V 0 to 25% P R 0 to 50% 0 to 100% CO2 H 0 to 5000 ppm J 0 to 1% K 0 to 2% L 0 to 5% M 0 to 10% N 0 to 20% P 0 to 50% R 0 to 100% – ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ *™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ ™ 1st component is CO2, 2nd component is CO. ™ : Dual-components are possible Both components are able to have 2nd range. 2nd range is x 2 or x 2.5 of 1st range, choose the Code symbols * : Dual-components are possible ™ But only one component, CO2 or CO, is able to have 2nd range. 2nd range is x 2 or x 2.5 of 1st range, choose the Code Symbols. — : Impossible. FUNDAMENTAL PRINCIPLE DIAGRAM Infrared–ray light source Gas inlet Gas outlet Detector M Synchronuous motor Measuring cell Mass flow sensor Rotary sector DC amplifier CPU Input Remote range Contact output D/A Output 0 to 1V, 4 to 20mA DC Operating panel Display Operation key A/D Rectifier AC amplifier Remote output hold Range identification signal Output during calibration 5 ZRH OUTLINE DIAGRAM (1) Horizontal case (Unit:mm) 483 465 443 7 30 380 25 ZRH 124.5 Power switch Operating panel (Rack mounting plate) 133 7 57.2 Sample gas inlet (Rc 1/4 or NPT 1/4) Sample gas outlet (Rc 1/4 or NPT 1/4) Panel cutout dimensions (in case of panel mounting) 126+2 –0 External connection terminal (1st component) (2nd component) (AUTO CAL) Power terminals 435 Purge gas inlet (Rc 1/4 or NPT 1/4) 436 +2 –0 6 (2) Vertical case Panel flush mounting 440 424 Panel mounting fixture 294 Door open -200° 283 radius 118 148 170 178 Wiring hole (ø22) with rubber bushing Panel cutout and spacing 281+2 0 430+2 0 430+2 0 150 Rc1/4 or NPT1/4 (Sample gas outlet) Rc1/4 or NPT1/4 (Sample gas inlet) Rc1/4 or NPT1/4 (Purge gas inlet) 35 35 35 30 280 80 350 Wall mounting 454 440 484 70 294 10 5 Door open -200° 283 radius 118 148 170 178 Wiring hole (ø22) with rubber bushing Rc1/4 or NPT1/4 (Sample gas outlet) Rc1/4 or NPT1/4 (Sample gas inlet) Rc1/4 or NPT1/4 (Purge gas inlet) 35 35 35 30 280 80 424 7 ZRH CONNECTION DIAGRAM (Same for horizontal and vertical cases) M4 screws used 1st component Output 1: 0 to 1V DC 2nd component Range identification contact output (option) Remote hold input(option) Remote range input(option) Output 1: 0 to 1V DC AUTO CAL Range identification contact output (option) Under calibration contact output Auto calibration failure contact output Remote start input (option) 1 2 3 7 8 9 1 2 3 7 8 9 1 2 3 7 8 9 Zero gas contact output Span gas 1 contact output Span gas 2 contact output Output 2: 4 to 20mA DC 4 10 5 11 6 12 Output 2: 4 to 20mA DC 4 10 5 11 6 12 Remote range input(option) 4 10 5 11 6 12 Fault SCOPE OF DELIVERY 1 1 1 2 4 x x x x x gas analyzer main unit test report instruction manual Power fuse panel mounting bracket ORDERING INFORMATION 1. Analyzer type. 2. Maximum, normal and minimum concentrations of sample gas as well as type and content (percent by volume) of concomitant gas. 3. Temperatures (maximum, normal and minimum), pressure and humidity of sample gas. 4. Dust conditions (mg/Nm3 or particle size, characteristics, etc.) and environmental conditions. 5. Other items RELATED DEVICES • • • • Gas sampling device Accommodating locker Standard gas (for calibration) Receiving instrument Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS3-111E 价格&库存

很抱歉,暂时无法提供与“EDS3-111E”相匹配的价格&库存,您可以联系我们找货

免费人工找货