0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS3-115C

EDS3-115C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS3-115C - PARAMAGNETIC OXYGEN ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS3-115C 数据手册
PARAMAGNETIC OXYGEN ANALYZER DATA SHEET This product is an analyzer which measures oxygen concentration in a sample gas by converting it into pressure, utilizing the magnetic property of oxygen. When compared with the oxygen analyzers of other measuring systems, this oxygen analyzer features a faster response, and smaller influence by coexisting gas and combustible gas, etc. Further, this analyzer is easy to use because of abundant functions such as discretionary range setting and interactive operation. It is usable in diverse field including control of various heat treating furnaces, combustion furnaces and other various fields. ZAJ FEATURES 1. Because of a pressure detection type, response is quick. 90% response can be reached within 2sec. 2. Measuring range can be set in any range of 0 to 2 ... 100%O2 3. Combustible gases do not affect measurements. 4. Measurements are scarcely affected by coexisting gases (H2, CO2 etc). 5. Suppression range is possible (for example, 21 to 100%, 100 to 95%O2 etc). 6. Interactive operation is possible by using liquid crystal display. 7. Parts which are brought in contact with gases are made of anticorrosive materials such as stainless steel and teflon. SPECIFICATIONS Measuring range: 1) When reference gas is N2, 0 to 2 ... 0 to100%O2 (freely settable in 1%O2 steps) 2) When reference gas is air, 21 to 23 ... 21 to 100%O2 or 21 to 19 ... 0%O2 (freely settable in 1%O2 steps) 3) When reference gas is 100%O2, 100 to 98 ... 100 to 0%O2 (freely settable in 1%O2 steps) Numbers of range: 2 ranges Measuring system: Paramagnetic pressure type Output signal: 4 to 20mA DC (load 550Ω max.) 0 to 1V DC Repeatability: Within ± 0.5% of full scale (in 10% or higher ranges) Within ± 1% of full scale (in ranges below 10%) Within ± 1% of full scale/week (in 10% or higher ranges) Within ± 1.5% of full scale/week (in ranges below 10%) Span drift: Within ± 2% of full scale/week Flow rate of sample gas: 0.5L/min. or 1L/min Response time (90% response: *Indication start-up time): 2sec or less (sample gas flow rate 1L/ min, range width 5%O2 or more) 3sec or less (sample gas flow rate 1L/ min, range width less than 5%O2) 3sec or less (sample gas flow rate 0.5L/ min) *The time (= 1sec.) required for gas replacement in the internal piping is not included. Linearity: Within ± 2% of full scale Compositional variations: 0.04%O2 o r 1% of full scale, or whichever is larger. Sample gas temperature: 0 to 40˚C Pressure loss: Approx. 1.3kPa {about 130mmH 2O}(at sample gas flow rate 0.5L/min) Approx. 2.8kPa {about 280mmH 2O}(at sample gas flow rate 1L/min) Reference gas: N2, O2 gas or air Reference gas pressure: 100kPa (range width: 10%O2 or more) Specified pressure: 50 to 150kPa (range width: less than 10%O2) *Specified pressure is marked at the reference gas inlet. *Reference gas is supplied at the above pressure to allow for flow rates of 5 to 20mL/min. Purging gas (dry air or N2) flow rate: 1L/min (flowed for purging corrosive ambient gas) Gas inlet/outlet dimensions: Rc1/4 (PT1/4 female screw) or NPT1/4 Zero drift: EDS3-115c Date Apr. 1, 2011 ZAJ Materials of gas-contacting parts: Teflon and 304 stainless steel Temperature characteristic: 1.5% of full scale/10°C Warmup time: Approx. 2 hours Interference due to coexisting gas: (Deviation in O2 % of zero point caused by flowing interfering gas component at 100%) Interfering gas NO NO2 He H2 Ne HF CO n-C7H16 Xe C3H8 C3H6 C2H6 Deviation in O2% +43 +28 +0.30 +0.24 +0.13 +0.10 +0.01 –2.10 –0.95 –0.86 –0.55 –0.46 Interfering gas C3H4 H2S HC R CO2 NH3 C2H2 Ar SO2 N2O CH4 H2O Deviation in O2% – 0.44 – 0.39 – 0.30 – 0.27 – 0.26 – 0.24 – 0.22 – 0.22 – 0.20 – 0.20 – 0.02 Mounting method: Mounting on 19-inch rack, flush mounting on panel or desk top mounting Support 90° Note: Instrument mass of more than 70% should be supported at the bottom of the case. * For panel mounting or 19-inch rack mounting, a support should be provided for supporting the rear side of the case. OPTIONAL SPECIFICATION Alarm output: Upper limit alarm: Contact output; 1c contact Contact capacity; 250 AC, 2A (resistive load) Lower limit alarm: Contact output; 1c contact Contact capacity; 250 AC, 2A (resistive load) Remote range changeover: Range can be changed with external signal Signal input for range changeover; 5V DC Range identification signal output: Contact output; 1a contact Contact capacity; 250 AC, 2A (resistive load) Output hold: Each output can be held by external input signal Input signal for external hold; 5V DC (held by 5V input) Transmission function: RS-232C interface Half-duplex bit serial, start-stop synchronouse, 9600bps Automatic calibration: Zero/span calibration is performed automatically at a preset cycle. Calibration gas is supplied while driving the external electromagnetic valve. Calibration gas density setting range: Zero gas: 0.00 to 99.99%O2 (0.01%O2 step) Span gas: 0.00 to 99.99%O2 (0.01%O2 step) Calibration start: Built-in timer or remote start signal Output hold during calibration: Possible Calibration gas flow time: Up to Max. 60min and 59sec Calibration cycle: 1 to 168 hours (1 hour step) Contact output: Calibration: 1a contact Contact capacity: 250V AC, 2A (resistance load) Calibration error: 1a contact Contact capacity: 250V AC, 2A (resistance load) Remote start: Remote start input signal: 5V DC (start at more than 100msec of pulse input) Display: Liquid crystal display, concentration indication (4 digits), range indication (4 digits) message indication (24 characters, 2 lines) Output hold: Output hold is possible during calibration. Moving average time: 0 to 99.9sec Contact output: 1a contact calibration signal, instrument failure, contact capacity 250V AC, 2A (resistance load) Power supply: 85 to 264V AC, 50/60Hz Power consumption: Approx. 45VA Ambient temperature: –5 to +45°C Ambient humidity: Less than 90% RH Allowable (max.) external vibration: 1.0m/s2{0.1G}(0 to 30Hz) 0.5m/s2{0.05G}(30 to 100Hz) External dimension (HxWxD): Rack mount type 220x483x463mm Flush mount type 220x443x463mm Desk-top type 233x443x463mm Mass: Approx. 16kg Finish color: Munsell 5Y 8/1 Installation condition: • The instrument must be protected from direct sunlight and heat radiation from objects at high temperature. • For installing the instrument outdoors, it must be protected from the elements with a suitable casing or cover. • The instrument must be installed in a clean atmosphere free from corrosive or combustible gas. • The instrument must be free from severe external vibrations. When fast response time is required, it should be used in a place free from vibration. 2 CODE SYMBOLS 12345678 9 10 11 12 SCOPE OF DELIVERY Description Measuring range 2 range selectable Minimum range 2%O2 Maximum range 100%O2 Range setting before delivery 5/25 O2 range (Refer to "Measuring range" in SPECIFICATION) ZAJ 4Y 4- Main unit: 2 Response time Standard type (2sec/90% of full scale) (5% or more O2 of full scale) Power supply and pipe connection dimension 85 to 264V AC 50Hz/Rc1/4 85 to 264V AC 60Hz/Rc1/4 85 to 264V AC 50Hz/NPT1/4 85 to 264V AC 60Hz/NPT1/4 0 N E Y A B C D E F G A B C Use For general service Display Japanese English Option Without Automatic calibration Alarm output, remote range, range identification Transmission function (RS-232C) A+B A+C B+C A+B+C Construction Desk-top type 19 inches rack mount type Panel flush mount type 5 6 7 8 Analyzer unit x 1, 2 of fuses, one of instruction manual, one of accessory kit (one of restrictor, six of packings, two of filters, two of spanners) Items to be prepared separately: Standard gas for calibration Code symbol ZBM SY04-01 Reference gas • Measuring range 0 to 2 ... 100%O2 N2 : Code symbol ZBM NY04-01 • Measuring range 21 to 23 ... 100%O2 21 to 19 ... 0%O2 Air : Code symbol ZBM RY04-01 or instrumentation air • Measuring range 100 to 98 ... 0%O2 O2 : Code symbol ZBM SY04-01 Buffer tank ZBH410 3 Note (1) When using this analyzer, be sure to provide a buffer tank in the exhaust path immediately after the analyzer. This is required for preventing output fluctuation due to disturbances such as large noise and strong wind. (2) In case of air-suppletion range, span gas concentration should be ordered by specifying 80 to 100% of the full scale. At this time, clearly describe "manufacture according to weighing method and accuracy within O2 concentration corresponding to ± 1% of full scale." Otherwise, concentration error will increase. [Example] In case of 21 to 19%O2 range: Span gas concentration 19.0 to 19.4%O2/N2, manufacture according to weighing method, accuracy within ± 0.02%O2. (3) In case of oxygen-suppletion range, use O2 gas of purity 99.99% or more for zero gas in ranges of 10% or less O2 full scale, and that of purity 99.9% or more in other ranges. (4) Use a copper pipe (6/4 copper pipe) for the reference line. It should be as short as possible from the gas cylinder. If it is long, it takes time until it is stabilized after power ON. Do not use a plastic pipe, as it causes errors in reading due to permeantion of oxygen. CONSTITUTION Sampling system diagram (Example) Gas sampler Flow checker Buffer tank Membrane filter Atmosphere Gas inlet tube Mist filter Pressure alarm unit Electromagnetic valve Pump Electromagnetic valve Peltier gas cooler ZAJ Analyzer-unit Safety drain trap Regulation valve Drain Note) Span gas cylinder ZBM Zero gas cylinder ZBM Reference gas cylinder ZBM Polyethylene tude Copper pipe Ø6/Ø4 Exhaust 3 ZAJ OUTLINE DIAGRAM (Unit:mm) 483 465 443 35 400 28 ZAJ CO2 220 146 Supporter Power switch Operation panel (Rack mounting plate) • Supporter more than 70% of the instrument mass at the bottom of the case. < Front view > Gas inlet, outlet Rc 1/4 or NPT 1/4 Sample gas inlet Purge gas inlet Sample gas Reference gas inlet outlet 435 External connection terminal Terminal block 1 Terminal block 2 < Side view > R3.5 Panel cutout (for flush mounting) 7 213 +2 0 212 436 +2 0 RS232C connector FG Power supply terminal < Rear view > EXTERNAL CONNECTION DIAGRAM Terminal block 1 Output signal 4 to 20mA DC Oxygen concentration value Output signal 0 to 1V DC Oxygen concentration value Upper limit alarm contact output (option) 1 2 3 4 5 6 7 Lower limit alarm contact output (option) 8 9 11 12 13 14 15 16 17 18 19 Under calibration contact output Instrument abnormal contact output Remote range input (option) External hold input (option) Range identification contact output (option) Contact output for zero calibration gas Contact output for span calibration gas Terminal block 2 1 2 3 4 5 6 7 8 9 11 12 13 Power supply 14 15 16 17 18 19 Automatic calibration error contact output Remote start input POWER SUPPLY TERMINAL ( 85 to 264V AC ( 50/60Hz 10 20 10 20 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDS3-115C 价格&库存

很抱歉,暂时无法提供与“EDS3-115C”相匹配的价格&库存,您可以联系我们找货

免费人工找货