EDS3-124C

EDS3-124C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS3-124C - IN-SITU ZIRCONIA OXYGEN ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS3-124C 数据手册
IN-SITU ZIRCONIA OXYGEN ANALYZER ZSB DATA SHEET This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion moni-toring and control. The analyzer consists of a flow guide tube with a detector, which is directly inserted into a flue, etc. to introduce the gas to be analyzed, a transducer, which performs control, signal processing, display, input to and output from outside, and communication, and an auto calibration/blow unit. The detector of a unit sensor structure facilitates on-site maintenance. The transducer provided with an unconventional sensor diagnostic function and sensor renewal function ensures long-term stable detecting operation. FEATURES 1. No need for gas sampling devices Since the sensor unit is directly inserted into a flue, etc., gas-sampling devices such as gas aspirator and dehumidifier are not required, which ensures high response speed. 2. Easy maintenance The sensor in a unit structure mounted to the detector can be replaced easily. Since the detector and the flow guide tube are installed separately, the filter at the tip of the detector can be replaced easily, and detector and the flow guide tube can be maintained separately depending on the degree of formation of rust, for example. 3. High reliability ensured by the sensor diagnostic and sensor renewal functions Depending on the components in the gas to be measured, the sensor electrode may degrade. The transducer diagnoses the degree of degradation of the sensor and renews it electrically, thus ensuring high reliability and long-term stable measurement. 4. Improved safety Detecting a break of the thermocouple for heater control installed at the sensor, power supply to the detector is stopped. Furthermore, external contact input stops power supply to the detector in an emergency. Those functions along with the key lock function are equipped as standard to ensure improved safety. 5. Simple operation The transducer can be operated and various settings can be made using an interactive system, and display language is available in English, Japanese, and Chinese. SPECIFICATIONS General Measuring object: Oxygen in noncombustible gas Measuring method: Directly insert type zirconia system Measuring range: 0 to 2 ···Setting range at option 2 in 50 vol% O2 (in 1 vol% O2 steps) Within ±0.5%FS Within ±2%FS Within 4 to 7 sec, for 90% (from calibration gas inlet) More than 10 min. 4 to 20mA DC (allowable load resistance 500Ω or less) or 0 to 1V DC (output resistance more 100Ω or more) Rated voltage; 100 to 120V AC (operating voltage 90 to 132V AC) Rated frequency; 50/60Hz Repeatability: Linearity: Response time: Warmup time: Analog output: Power supply: Date EDS3-124c Apr 1, 2011 ZSB Power consumption: Maximum 240VA (Detector: approx. 200VA, Converter: approx. 40VA) Normal 70VA (Detector: approx. 50VA, Converter: approx. 20VA) Steel plates (main frame) Wall-mounting type: 700 X 400 X 180mm Self-standing type: 1500 X 530 X 550mm Wall-mounting type: Approx. 27 kg (excluding cable, detector and standard gas) Self-standing type: Approx. 48 kg (excluding cable, detector and standard gas) Munsell 5Y7/1, semi-gloss Mass: Finish color: Approx. 1.6kg Silver and SUS metallic color 1.5 to 2 L/min Blowdown air inlet pressure: 200 to 300kPa Calibration gas flow: Material: Outer dimensions (H x W x D): Converter (ZKM3) Concentration value indication: Digital indication in 4 digits Contact output signal: (1) Contact specification; 6 points, 1a 250V AC/3A or 30V DC/3A (2) Contact function; • Under maintenance • Instrument anomalies Note1) • Alarm Note2) • Zero calibration gas valve • Span calibration gas valve • Under blowdown Note3) Note1) The following Instrument errors (1) Thermocouples break (2) Sensor break (3) Temperature fault (4) Calibration fault (5) Zero/span fault (6) Output error the contact ON Note2) Alarm selects just one as mentioned below (1) High (2) Low (3) H/L (4) HH (5) LL, it turns ON while operating. Note3) Under blow down, it is available in case of option, and it turns ON while operating. Contact input signal: (1) Contact specification; 3 points (the following option) ON; 0V (10mA or less), OFF; 5V (2) Contact function; • External hold • Calculation reset • Heater OFF • Blow down (option) • Inhibition of calibration • Calibration start • Range change Calibration method: (a) Manual calibration with key operation (b) Auto. calibration (option) Calibration cycle; 00 day 00 hour to 99 days 23 hours (c) All calibration • Settable range Zero gas; 0.010 to 25.00% O2 Span gas: 0.010 to 50.00% O2 • Recommended calibration gas concentration Zero gas; 0.25 to 2.0% O2 Span gas; 20.6 to 21.0% O2 (oxygen concentration in the air) Mass: Finish color: Mounting method: Wall-mounting or self-standing Detector (ZFK8) Measured gas temperature: Flow guide tube system; −20 to +600ºC (for general-use, corrosive gas) Measured gas pressure: −3 to +3kPa Flow guide tube: • With or without blowdown nozzle Flange; JIS5K 65A FF Insertion length; 0.3, 0.5, 0.75, 1m • For high particulate gas (with blowdown nozzle) With or without cover Flange; JIS5K 80A FF Insertion length; 0.3, 0.5, 0.75, 1m Operating temperature: −10 to +60ºC for Primary detecting element −5 to +100ºC for detector 125ºC or less at detector flange surface with power applied Storage temperature: −20 to +70ºC Structure: Dust/rain-proof structure (IEC IP66 equivalent, except the filter part at the tip) Use a heat insulation cover in cold climates (as specified) Filter: Alumina (filtering accuracy 50µm) and quartz paper Main materials of gas-contacting parts: Zirconia, SCS14 (SUS316 equivalent), platinum, SUS304 Calibration gas inlet: φ6mm tube join Reference air inlet: φ6mm tube join Detector mounting: Horizontal plane ±45º, ambient air should be clean. Outer dimensions (L × max. dia.): 210mm × 100mm Calibration gas: 2 Blowdown: A function for blowing out dust with compressed air that has deposited in the flow guide tube. Blowdown can be performed only for a predetermined time and at prede-termined intervals. Blowdown cycle; 00 hour 00 minute to 99 hours 59 minutes Blowdown time; 0 minute 00 second to 0 minutes 999 seconds Output signal hold: Output signal is held during manual/ auto calibration, blowdown, sensor recovery proc-essing, warm-up, PID auto tuning, and while maintenance mode setting is "available". The hold function can also be released. Communication function: RS232C (MODBUS) standard specification RS485 (MODBUS) (option) Combustion efficiency display: When you select this display, "rich mode display" will be simultaneously displayed. This function calculates and displays combustion efficiency from oxygen concentration and measured gas temperature. Thermocouple (R) is required for temperature measurement. Operating temperature: −20 to +55ºC Operating humidity: 95% RH or less, non condensing Storage temperature: −30 to +70ºC Storage humidity: 95% RH or less, non condensing Outer dimensions (H × W × D): 182 × 163.5 × 70.6mm Approx. 2kg (excluding cable and detector) (IP66) Mounting method: Mounted flush on panel Mass: 3 ZSB CODE SYMBOLS 12345678 ZSB 2- 9 10 11 12 13 14 15 Description 4th digit 1 2 5th digit A B Converter mounting (4th digit) Wall-mounting type (with indication window) Self-stand type (with indication window) Sensor, Power supply, Cal. Gas inlet (5th digit) For general use without protection cover, 100/115 V AC, 50/60 Hz and inlet for φ6 mm tube For general use with protection cover, 100/115 V AC, 50/60 Hz and inlet for φ6 mm tube * Protection cover should be selected when ambient temperature is -10°C or lower. Sensor cable + calibration gas tube (6th digit) None 6 m cable (without conduit) + 6 m Teflon tube (φ6/φ4) 10 m cable (without conduit) + 10 m Teflon tube (φ6/φ4) 15 m cable (without conduit) + 15 m Teflon tube (φ6/φ4) 20 m cable (without conduit) + 20 m Teflon tube (φ6/φ4) 6 m cable (with conduit) + 6 m Teflon tube (φ6/φ4) 10 m cable (with conduit) + 10 m Teflon tube (φ6/φ4) 15 m cable (with conduit) + 15 m Teflon tube (φ6/φ4) 20 m cable (with conduit) + 20 m Teflon tube (φ6/φ4) 6 m cable (4-core cable only. Heater cable should be prepared by customer.) + 6 m Teflon tube (φ6/φ4) 10 m cable (4-core cable only. Heater cable should be prepared by customer.) + 10 m Teflon tube (φ6/φ4) 15 m cable (4-core cable only. Heater cable should be prepared by customer.) + 15 m Teflon tube (φ6/φ4) 20 m cable (4-core cable only. Heater cable should be prepared by customer.) + 20 m Teflon tube (φ6/φ4) * When exclusive-special conduit and heater cable are not used, the following conduit should be used. Conduit with outer diameter φ23 and inner diameter φ16 as specified in JIS C8411 For preparing two heater cables, their rating should be 3 A or more. Calibration gas unit (7th digit) Automatic calibration unit + zero gas + filter regulator Automatic calibration unit + zero gas + air standard gas Manual calibration unit + zero gas + filter regulator Manual calibration unit + zero gas + air standard gas Flow guide tube (9th, 10th and 11th digit) (Flange) (Application) None None SUS304 For general use SUS304 For general use SUS304 For general use SUS304 For general use SUS316 For corrosive SUS316 For corrosive SUS316 For corrosive SUS316 For corrosive SUS316 Without high particulate cover SUS316 Without high particulate cover SUS316 Without high particulate cover SUS316 Without high particulate cover Others Others Output signal (12th digit) 4 to 20mA DC 0 to 1V DC Language (13th digit) Japanese English Chinese Communication functions (14th digit) RS232 RS485 Reference gas (15th digit) None φ6mm tube joint (Length) None 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm Others (Note) 6th digit Y A B C D E F G H J K L M 7th digit 1 2 3 4 9th, 10th, 11th digits 0 5 5 5 5 5 5 5 5 6 6 6 6 Z Y A A A A B B B B D D D D Z 0 3 5 7 1 3 5 7 1 3 5 7 1 Z With blow-back unit With blow-back unit With blow-back unit With blow-back unit 12th digit B E 13th digit J E C 14th digit 1 2 15th digit Y 1 4 DEVICE CONFIGURATION The device to be combined differs according to the conditions of the gas to be measured. Please select the flow guide tube, referring to the table shown below. Measured gas Application Temperature Gas Flow Dust Less than 0.2g/Nm3 5 to 20m/s Less than 1g/Nm3 Less than 25g/Nm3 Note For boiler. Fuel; gas, oil When moisture content in measured gas is low. When moisture content in measured gas is low. With blow-down Device configuration Type at 4th to 7th digits ZSB ZSB ZSB 2– 2– 2– Flow guide tube at 9th to 11th digits 5A 5B 6D Boiler, refuse incinerator, sludge incinerator, 600ºC or less etc. Note (1) Dust volume is approximate value. (2) Reference air port specification should be selected when standard gas concentration changes. (3) For optional specifications, contact the manufacturer separately. SCOPE OF DELIVERY 1) Standard delivery 1 set x zirconia oxygen analyzer 1 set x instruction manual 1 set x standard accessories · 1 x O -ring (for detector) · 1 x ceramic filter (for detector) · 2 each x fuse (3.15 A, 0. 5 A) · 1 set x inlet (for standard gas connection) · 1 x polyethylene tube (for standard gas connection) · 1 x Toaron tube (for standard gas connection) · 1 set x flow guide tube accessories (bolt, nut, spring washer x 4 pieces each) 2) Items to be prepared separately · Replacement detector · Spare (detector) Spares for 1-year operation 1 x O -ring 2 x ceramic filter 1 x Filter frame Spares for 2-year operation 2 x O -ring 4 x ceramic filter 2 x Filter frame CAUTIONS · If combustible gas (CO, H2 etc.) exists in the measured gas, error will occur due to burning at the sensor section. The inclusion of corrosive gas (Si vapor, alkaline metal, P Pb etc.) will shorten the , life of the sensor. · When the measured gas temperature is high (+300ºC or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value (+125ºC). The flow guide tube should be attached in the direction in which the gas flow to the detector decreases. · If much dust is contained in the gas, the flow guide tube should be connected obliquely from the top. This tube should also be connected in the direction where gas flow into the detector section is reduced. · In application to refuse incineration, automatic blow-down of the flow guide tube should be avoided (in order to protect the tube from corrosion due to drain formation). Blow-down should be carried out manually when indication change becomes small during stop of the incinerator. 5 ZSB CONFIGURATION Rc1/4 (upper side blow port should be selected) Blow-down, 200 to 300kPa Solenoid valve (not supplied) Reduction valve (unnecessary when supply air pressure is 200 to 300kPa) Supply air Heat insulation cover Flow guide tube Detector (ZFK8) 15ASGP tube equivalent or φ10/φ8mm Teflon pipe or steel pipe (not supplied) 15ASGP tube equivalent or φ10/φ8mm Teflon pipe or steel pipe (not supplied) Gas temperature. 600ºC max. 6 Ref. air 5 1 2 3 4 White Black White Red Rainproof flexible conduit. (Max. 20m) Blue Gas outlet Yellow Gas temperature. 600ºC max. Flow guide tube for high particulate Cable gland Gas outlet T1 R1 1 Gas temperature. 600ºC max. Flow guide tube for high particulate with cover 2 + O2 – O2 input Converter (ZKM) 11 12 ZERO GAS 3 4 + TC1 – Thermocouple input 5 + or AO 6 – 7 8 9 10 13 14 TM-1 ZV *1 Analog output 4 to 20mA DC or 0 to 1V DC Thermocouple for combustion control Fault contact output Blow HEATER contact Calibrating output gas contact output Alarm Maintenance contact Calibrating gas contact output contact output output MAINTE COM SPAN GAS Contact input DI1 DI2 ALARM AC power supply N AC L + TC2 – φ6mm Teflon tube for calibration gas (not supplied) 15 1 TM-2 2 3 Auto breaker 16 DI3 DICOM SV 17 18 19 20 21 22 23 24 25 26 27 28 Converter Maintenance signal during calibration/maintenance R 1 T 2 E 3 Earth 3 TGS When auto calibration is selected Joint Solenoid valve Zero Flowmeter Solenoid valve (0.2L/min) T1 12 4 5 6 7 8 9 10 11 R1 AC power supply *1 Use a screw for mounting of converter main unit (1.5L/min) 2 Zero Pressure regulator O2/N2 Reference air Span Standard gas for zero point Flowmeter Container box Span Pressure regulator Supply air Reduction valve (mounted on the main unit) Air or O2/N2 Standard gas for span point When air standard gas is selected 6 OUTLINE DIAGRAM (Unit : mm) Self-standing type: ZSB2 Instrumentation air inlet (for blow-back) Rc1/2 400 180 100 {490} External connection terminal (converter) 700 G1/2 Rc1/2 Rc1/4 Instrumentation air inlet (for span calibration gas) Rc1/4 Instrumentation air outlet (for span calibration gas) Filter regulator (selectable by code symbol) 760 4-φ15 490 530 350 550 30 Front view Right side view (Front) Cable gland exclusive for detector EXTERNAL CONNECTION DIAGRAM (POWER SUPPLY) 1 R 2 T 3 E 4 5 6 1500 External connection terminal (power supply) Instrumentation air outlet (for blow-back) Regulator + solenoid valve (selectable by code symbol) {350} Anchor plan, anchor bolts (option) M12×160×50 7 8 9 10 11 12 Power Ground supply Maintenance signal Calibration status/ maintenance status Inlet (for φ6 mm tube) (Rear) Cable gland A15A (Box bottom view) 7 ZSB Wall-mounting type: ZSB2 Instrumentation air inlet (for blow-back) Rc1/2 255 180 300 4-φ15 400 External connection terminal (converter) 700 G1/2 Rc1/2 Instrumentation air outlet (for blow-back) Regulator + solenoid valve (selectable by code symbol) External connection terminal (power supply) Rc1/4 Instrumentation air inlet (for span calibration gas) Rc1/4 Instrumentation air outlet (for span calibration gas) Filter regulator (selectable by code symbol) Front view Right side view Rear view (Front) Cable gland exclusive for detector EXTERNAL CONNECTION DIAGRAM (POWER SUPPLY) 1 R 2 T 3 E 4 5 6 7 8 9 10 11 12 Inlet (for φ6 mm tube) (Rear) Cable gland A15A Power Ground supply Maintenance signal Calibration status/ maintenance status (Box bottom view) 8 500 Converter: ZKM3 163.5 70.6 10 143.5 Oxygen Analyzer MODE ESC ENTER POWER Made in Japan TYPE OUTPUT DC POWER AC SER. NO. MFD 50/60Hz 60VA OXYGEN TRANSM ITTER 172 変換器へ供給する電源電圧は、接続される 検出器の電源電圧に合わせてください。 注 意 FUSE T 0.5A POWER Power supply must be selected the same voltage of detector. CAUTION HEATER FUSE T 2.5A POWER ON OFF + O2 − + TC1 − + AO − FAULT BLOW ZV HEATER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ALARM MAINAC COM SV + TC2 − DI1 DI2 DI3 DIN L TENANCE COM 4-φ4.5 MTG. holes External terminal (TM1) O2 sensor input Exclusive cable Analog output 4-20mA DC or 0-1V DC Fault contact output contact capacity 250V AC/3A 30V DC/3A Blow contact output 250V AC/3A 30V DC/3A O2 sensor heater power output O2 sensor thermocouple input 1 2 O2 3 4 TC1 5 + − + − + or AO 6 7 8 9 BLOW 10 11 ZV ZERO GAS 12 13 14 − FAULT ALARM MAINTE HEATER SPAN GAS Ground terminal M4 + 15 TC2 − 16 DI1 17 DI2 18 DI3 DICOM 19 20 21 22 23 COM 24 25 SV 26 N 27 AC Thermocouple input type R Contact input (combustion control) Short circuit : on (Current 5mA) Open : off (Voltage 5V) Alarm contact output 250V AC/3A 30V DC/3A Maintenance contact output 250V AC/3A 30V DC/3A Calibrating gas contact output contact capacity 250V AC/3A 30V DC/3A AC Power supply input (100 to 240V AC) COMMUNICATION TERMINAL (TM2) /INSERTION TERMINAL Terminal number 1 RS232C RS485 TXD TRX+ 2 RXD TRX– 3 GND GND Remarks Standard Option 182 L 28 Fuji Electric Co.,Ltd. 9 ZSB Detector: ZFK8 Approx.132 φ 80 φ 67 6-φ 6 Approx.62 5 Approx.130 Temp.Proof cover (To order) Terminal box EXTERNAL CONNECTION DIAGRAM φ 79 φ 26 φ 85 Heater Thermocouple Element output Filter Approx.30 125.5 (?17.5) 20 TK4J4664R0 made in japan 40 5 S- H 2 4 T- 10 45° ° 60 1 3 2 4 Black / White/ red / White/ 2-core wire 5 6 yellow / blue 4-core wire Ground-wire Screw: M4 Exclusive-special cable Calibration gas inlet Ref. Air inlet (to order) (To order) SUS316,for φ 6/φ 4 tube SUS316,for φ 6/φ 4 tube Exclusive Cable gland Replacement Detector element Sensor unit (ZFK8YY) (132.7) (88.4) 3.5 4-φ 3.5(Mount for detector) φ 35 45° S+ H 6 1 T+ 3 Flow guide tube (for general-use) 12 Approx. L φ155 Approx. 20 φ130 φ67 Gas inlet φ34 ZSB 2-5A 3 5 7 1 Gas outlet 6-M5 detector side Code 11th Oxygen detector L (m) 3 0.3 5 7 1 Z L= (to order) 8-φ15 MTG. holes 0.5 0.75 1.0 3.3 4.1 4.8 MASS 2.7 Approx (kg) Flow guide tube (for corrosive gas) φ155 12 3 Approx. L Approx. 40 φ130 φ67 Gas inlet φ67 φ60.5 20 ZSB 2-5B 3 5 7 1 Gas outlet 6-M5 detctor side Code 11th Oxygen detector L (m) 3 0.3 5 7 1 Z L= (to order) 8-φ15 MTG. holes 0.5 0.75 1.0 4.5 6.1 7.6 MASS 3.3 Approx (kg) 11 ZSB Flow guide tube (for high particulate) 4-Rc 1/4 with plug φ180 φ1 45 Blow down air inlet At installation, select upper blow port at one position (as a measure for drain). 8-φ19 MTG. hole φ67 φ29 Code 11th 3 0.3 5 7 1 Z L= (to order) .5 L (m) 0.5 0.75 1.0 5.6 7.0 8.3 Flange: JIS 5K80A FF ZSB MTG. position MASS 4.5 Approx (kg) Packing 185 ZSB Oblong hole 50 Gas outlet Approx. L 2-6D 3 5 7 1 30 Gas flow Applicable companion flange height about 160 mm (Closing gas outlet should be avoided.) Tube (50A SCH40) Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDS3-124C 价格&库存

很抱歉,暂时无法提供与“EDS3-124C”相匹配的价格&库存,您可以联系我们找货

免费人工找货