EDS3-126A

EDS3-126A

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS3-126A - NDIR TYPE INFRARED GAS ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS3-126A 数据手册
NDIR TYPE INFRARED GAS ANALYZER DATA SHEET This infrared gas analyzer measures the concentration of gas by utilizing the characteristic of gas (molecule consisting of different-kind atoms) that it absorbs the infrared ray of a specific wavelength. Stable and accurate measurement is ensured due to use of a mass flow sensor with a high sensitivity, interferencecompensating detector, etc. This analyzer is to be built in sampling equipment and optimally usable for measuring the concentrations of various gases. ZRC6 FEATURES 1. Most suited for incorporation in equipment This analyzer can be readily built in customer’s sampling equipment, because its analyzing block, signal processing circuit and power unit are all accommodated in a compact case. 2. High measurement accuracy and stability A single light source/double beam system, and a highsensitivity mass flow sensor ensure accurate and stable measurement. 3. Minimum influence by other gases An interference-compensating detector substantially suppresses interference by the disturbing gases coexisting in sample gas. 4. Wide dynamic range A range ratio of max. 1:20 can be secured in standard 2 ranges. Range selection follows the external selection input signal. Gas inlet, outlet, purge gas inlet size: Rc1/4, or NPT1/4 female screw Purge gad flow rate: 1L/min± 0.5L/min Purging is required when combustible and corrosive gases are contained in the atmosphere or the range of CO2 is less than 100ppm. In other cases, purging should be made as necessary. Scope of delivery: Analyzer × 1, power fuse × 2, Instruction manual × 1 Mounting method: On table-top Installation condition: Install the analyzer at a place not exposed to direct sunlight or the radiation from a high temperature object. Avoid vibration, and select a clean place free from corrosive and/or combustible gasses. If installing outdoors, provide a suitable casing or cover to protect the analyzer from wind, rain, etc. Standard Requirements for measuring gases: Temperature: 0 to 50°C Moisture: Below a level where saturation occurs at 2°C (condensation unallowable). Dust: 0.3 µ m or less (Recommended membrane filter; ZBBM6) Pressure: 10kPa or less (Flow rate: 0.5L/min)(Gas outlet side should be open to the atmospheric air) Standard control for sample gas: Calibration gas: Dry gas Interfere control gas: 2°C saturation Measuring system: Infrared-ray absorption method, non-dispersion, differential flow system, single light source, double-beam system. SPECIFICATIONS 100V-240V AC, 50/60Hz Power supply voltage variation in running time; within ± 10%. Power consumption: 130VA max Ambient temperature: -5 to +45°C Ambient humidity: 95% RH or less Enclosure temperature: -20 to +60°C Enclosure humidity: 95% RH or less Casing: Zinc plated steel (Special chromate) (JIS: SECC-C equivalent) steel color Indoor-use Dimensions (H × W × D): On Table-top 176 × 433 × 229 mm Mass (Weight): Approx. 9 kg Warm-up time: About 4 hours (after power ON) Materials of gas-contacting parts: Sample cell: SUS304, chloroprene rubber Infrared-ray transmitting window: CaF2 or sapphire Internal tubing: fluoride ethylene resin Power Supply: EDS3-126a Date Apr. 1, 2011 ZRC6 Measurable components and measuring ranges: Measurable components CO CO2 NO SO2 Carbon monoxide Carbon dioxide Nitric oxide Sulfur dioxide Minimum Maximum measuring range measuring range 0 to 100ppm 0 to 50ppm 0 to 100ppm 0 to 100ppm 0 to 100vol % 0 to 100vol % 0 to 2000ppm 0 to 10vol % B D P A 6 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 ZRC6 1- Y00 - F Description Basic structure Single-component analyzer (bench) Measuring components CO (Carbon monoxide) CO2 (Carbon dioxide) NO (Nitric oxide) SO2 (Sulfur dioxide) 1st measuring range Note: For measuring range, refer to Table. 0 to 50ppm 0 to 100ppm 0 to 200ppm 0 to 250ppm 0 to 500ppm 0 to 1000ppm 0 to 2000ppm 0 to 5000ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% Measuring ranges: Shown on another table Range selection: Short circuit between external terminal 13 and14 switches to high range side. Output signal: 0 to 1V DC/4 to 20mA DC Simultaneous output Linearity: ± 2% of full scale 0 to 1V DC/permissible load resistance; 100kΩ or more 4 to 20mA DC/permissible load resistance; 550Ω or less Repeatability: ± 0.5% of full scale Zero drift: ± 2% of full scale/week Span drift: ± 2% of full scale/week Response time: Maximum within 20 seconds including gas replacement time of sample gas. (for 90% FS response) but differs from the length of sample cell. Measured gas flow rate: Standard 0.5L/min± 0.1L/min A B C D E F G H J K L M N P R 0 2 3 4 5 8 1 9 A B 0 E F G 2nd measuring range 1st range × 0 ×2 × 2.5 ×4 ×5 ×8 × 10 × 20 Gas aperture shape Rc1/4 NPT 1/4 female screw Power Supply 100V AC to 240V AC, 50/60Hz Measurable gas type Atmosphere Combustion exhaustion gas Converter exhaustion gas Principle diagram of infrared type measurement Motor Distribution cell Trimmer (interference filter) Reference cell Interference compensation detector Rotation sector Sector sync signal Sample cell Infrared light source (Single-beam light source) Sample gas inlet Converter Sample gas outlet AC amplification Range switching Output 4 to 20mA DC 0 to 1V DC (Simultaneous output) V/I DC Smooth- Synchronous Linearizer amplification ing genarator 2 Table 1. Measurable component and range – availability check table – (1) Single-component analyzer (NO, SO2, CO2, CO) : NO analyzer measurable range : CO2 analyzer measurable range 2nd range 1st range A 0 to 50ppm B 0 to 100ppm C 0 to 200ppm D 0 to 250ppm E 0 to 500ppm F 0 to 1000ppm G 0 to 2000ppm H J K L M N P R 0 to 5000ppm 0 to 1% 0 to 2% 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% B 0 to 100ppm : SO2 analyzer measurable range : CO analyzer measurable range D E 0 to 500ppm C 0 to 200ppm F 0 to 1000ppm G 0 to 2000ppm H 0 to 5000ppm J 0 to 1% K 0 to 2% 0 to 250ppm — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 2nd range 1st range A 0 to 50ppm B 0 to 100ppm C 0 to 200ppm D 0 to 250ppm E 0 to 500ppm F 0 to 1000ppm G 0 to 2000ppm H 0 to 5000ppm J 0 to 1% K 0 to 2% L M N P R 0 to 5% 0 to 10% 0 to 20% 0 to 50% 0 to 100% L 0 to 5% M 0 to 10% N 0 to 20% P 0 to 50% R 0 to 100% — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 3 ZRC6 OUTLINE DIAGRAM (Unit:mm) < Analyzer main unit > Connecting terminal < BACK > Fuse Purge gas inlet RC1/4 or NPT1/4 Sampling gas outlet RC1/4 or NPT1/4 Sampling gas inlet RC1/4 or NPT1/4 PURGE < SIDE > < UPPER > (229) (210) < FRONT > (432.5) (176) (164) SPAN CAL. (VR4) ZERO CAL. (VR7) CONNECTING DIAGRAM 1 2 3 4 5 6 7 8 Zero Adj./Span Adj. 9 10 11 12 13 14 15 16 Power supply 100V AC to 240V AC Output 1 Output 2 Range (0 to 1V DC) (4 to 20mA DC) Check (0.04 to 0.2V DC) Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan SOURCE 2A FUSE INLET OUTLET
EDS3-126A 价格&库存

很抱歉,暂时无法提供与“EDS3-126A”相匹配的价格&库存,您可以联系我们找货

免费人工找货