    EDS3-133F - INFRARED GAS ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS3-133F 数据手册
INFRARED GAS ANALYZER DATA SHEET This gas analyzer (ZRE) is capable of measuring the concentration of NO,SO2,CO2,CO,CH4 and O2 components in sample gas. NO,SO2,CO2,CO and CH4 are measured by non-dispersion infrared method (NDIR), while O2 is measured by fuel cell, or zirconia method. Up to 5 components including O2 can be measured simultaneously. This analyzer is designed with smaller physical dimensions. It is well suited for compact analyzing system designs. In addition maintenance is simplified through adoption of the single-beam system. Optimum use as an analyzer unit of measurement system for combustion exhaust gas from refuse incinerator and boiler, or gas from various industrial furnaces. ZRE Measurable gas components and measuring range: NO SO2 CO2 CO CH4 O2 built in fuel cell O2 built-in Paramagnetic External Zirconia Minimum range 0 - 200ppm 0 - 200ppm 0 - 100ppm 0 - 200ppm 0 - 500ppm 0 - 10vol% Maximum range 0 - 5000ppm 0 - 10vol% 0 - 100vol% 0 - 100vol% 0 - 100vol% 0 - 25vol% FEATURES 1. Small and light The size is small 133×483×418mm (H×W×D) and light (8kg). But it is capable max. 5 component measurement in one analyzer. 2. Easy maintenance Because of single-beam system the measurement unit is simple with no need for optical adjustment. Therefore, maintenance is easy. 3. Easy operation Operation can be carried out smoothly in an interactive way through a large-size LCD. 4. Abundant functions Various optional functions are available such as auto calibration control, high and low concentration alarm, remote range switch, and range identification signal, etc. 0 - 5vol% 0 - 25vol% SPECIFICATIONS Standard Specifications Principle of measurement: NO, SO2, CO2, CO, CH4 ; N on-dispersion i nfrared-ray a bsorption method Single l ight s ource a nd s ingle b eams (single beam system) O2 ; uel cell O2 sensor (built in) or zirconia O2 F sensor (externally installed TYPE: ZFK7) (Built in paramagnetic O2 sensor will be next revision.) • Max. 5 components measurement including O2. • Measuring range ratio max. 1:10 • Measuring ranges are changeable between t he s pecified m inimum a nd m aximum range Settable one range or t wo ranges • For possible combinations of components and ranges, refer to Table1. Measured value indication: Digital indication in 4 digits (LCD with back light) • Instantaneous value of each component • Instantaneous value after O 2 correction (only in NO, SO2, CO measurement with O 2) • Average value after O2 correction (only in NO, SO2, CO measurement with O 2) • O2 average value Analog output signals: 4 to 20mA DC or 0 to 1V DC, isolated internally from circuit and ground; 12 outputs max. max. load 550W for 4 to 20 mA DC min. load 100kW for 0 to 1V DC * Refer to Table2 for the channel No. of d isplayed v alues a nd a nalog o utput signals. EDS3-133f Date Apr. 1, 2011 ZRE Analog input signal: For signal input from externally installed O2 sensor. Signal requirement; (1) Signal from Fuji’s Zirconia O2 sensor (TYPE: ZFK7) (2) 0 to 1V DC from an O2 sensor Input s ection i s n ot i solated. This feature is effective when an O2 sensor is not built in. * Externally installed O2 sensor should be purchased separately. Digital output: (Option) 1c c ontact ( 24V D C/1A, r esistive l oad) max.15 outputs Instrument error, calibration error, range identification, auto calibration status, High/Low limit alarm contact output * All relay contacts are isolated mutually and from the internal circuit. Digital input: (Option) Voltage contact (Supply 12 to 24V DC/15mA max. at ON) max. 9 inputs Remote range switch, auto calibration remote start, remote holding, average value resetting, Isolated from the internal circuit with photocoupler. ; 100V to 240V AC Power supply: Voltage rating Allowable range ; 85V to 264V AC Frequency ; 50Hz/60Hz Power consumption ; 100VA max. Operation conditions: Ambient temperature ; - 5˚C to 45˚C (40˚C max. when 2 optical system at 200V AC power source) Ambient humidity ; 90% RH max., non-condensing Storage conditions: Ambient temperature - 20˚C to 60˚C ; Ambient humidity ; 100% RH max., non-condensing Dimensions (H × W × D): 19-inch rack mounting t ype: 133 x 483 x 418mm Panel mounting t ype: 133 x 443 x 418mm Mass: Approx. 8 kg Finish color: Front panel; Black (DIC P 1000-F) Cool gray (PANTON IC-F) Casing; Cool gray (PANTON IC-F) Enclosure: Steel casing, for indoor use Material of gas-contacting parts: Gas inlet/outlet; SUS304 Sample c ell; S US304,chloroprene rubber Infrared-ray transmitting window; CaF2 Paramagnetic O 2 sensor cell : SUS316 Fuel cell O2 sensor cell : ABS resin Internal piping; Toaron, Teflon Gas inlet/outlet: Rc1/4 or NPT1/4 internal thread Purge gas flow rate: 1L/min ( when required) Life time of fuel cell O2 sensor: 2 years Standard Functions Output signal holding: Output signals are held during manual and auto calibrations by activation of holding (turning “ON” its setting). The output to be held are the ones just before start calibration mode or setting value. It is selectable. Indication of instantaneous values will not be held. Switch ranges: The switch ranges function is available in manual, auto, and remote modes. Only preset switch method is effective. Manual: Allows r ange t o s witch by key o peration. Auto: Allows range to switch from low to high range when 90%FS or more is available in the low range. Allows range to switch from high to low range when 80%FS or less is available in the low range. Remote: Voltage c ontact i nput ( for m easurable (Option) components) Allows range to switch via an external signal when remote range switch input is received. When t he c ontact i nput t erminals for each component are input voltage, the first range is selected, and it is switched to the second range when the terminals are open. * These range value are settable between original first range and second range. Optional Functions Remote output holding: Output signal is held at the latest value or setting value by voltage input the remote output holding input terminals. Holding is maintained while the voltage input the terminals. Indication of instantaneous values will not be held. Range identification signal: The present measuring range is identified by a contact signal. The c ontact o utput t erminals for e ach component turn on when the first range is selected, and when the second range is selected, the terminals are open. Auto calibration: Auto calibration is carried out periodically at the preset cycle. When a standard gas cylinder for calibration and a solenoid valve for opening/closing the gas flow line are prepared externally by the customer, calibration will be carried out with the solenoid valve drive contacts for zero calibration and each span calibration turned on/off sequentially at the set auto calibration timing. Auto calibration cycle setting: Auto calibration cycle is set. Setting is variable within 1 to 99 hours (in increments of 1 hour) or 1 to 40 days (in increments of 1 day). 2 Gas flow time setting: The time for flowing each calibration gas in auto calibration is set. S ettable w ithin 6 0 t o 9 00 s econds ( in increments of 1 second) Auto calibration remote start: Auto calibration is carried out only once according to an external input signal. Calibration sequence is settable in the same way as the general auto calibration. Auto calibration is started by opening the auto calibration remote start input terminals after input voltage for 1.5 seconds or longer. Auto zero calibration: Auto zero calibration is carried out periodically at the preset cycle. This cycle is independent on “Auto calibration” cycle. When zero calibration gas and solenoid valve for opening/closing the calibration gas flow line are prepared externally by t he c ustomer, zero c alibration w ill b e carried out with the solenoid valve drive contact for zero calibration turned on/off at the set auto zero calibration timing. Auto zero calibration cycle setting: Auto zero calibration cycle is set. Setting is variable within 1 to 99 hours (in increments of 1 hour) or Setting is variable within 1 to 40 days (in increments of 1 day) Gas flow time setting: The timing for flowing zero gas in auto zero calibration is set. Settable 60 to 900 seconds (in increments of 1 second) High/low limit alarm: Alarm contact output turns on when measurement value reach the preset high or low limit alarm value. Contacts turn on when the channel value of each channel exceeds the high alarm limit value or falls below the low alarm limit value. Instrument error contact output: Contacts turn on at occurrence of analyzer error No. 1, 2, 3 or 10. Calibration error contact output: Contacts turn on at occurrence of manual or auto calibration error (any of errors No. 4 to 9). Auto calibration status contact outputs: Contacts turn on during auto calibration. O 2 correction: Correction of measured NO, SO2 and CO gas concentrations into values at reference O2 concentration Correction formula: 21-On C = –––––––– x Cs 21-Os C : Sample gas concentration after O2 correction CS : Measured concentration of sample gas OS : Measured O 2 c oncentration (Limit setting: 1 to 20% O2) OV : Reference O2 concentration (value changeable by s etting.0 t o 19% O2) Average value after O2 correction and O2 average value calculation: The result of O2 correction or instantaneous O2 value can be outputted as an average value in the preset period of time. Used for averaging is the moving average method in which sampling is carried out at intervals of 30 seconds. (Output is updated every 30 seconds. It is the average value in the determined period of time just before the latest updating.) Averaging time is settable within 1 to 59 minutes (in increments of 1 minute) or 1 to 4 hours (in increments of 1 hour). Average value resetting: The above-mentioned output of average value is started from the initial state by opening the average value resetting input terminals after input voltage for 1.5 seconds or longer. Output is reset by input voltage and restarted by opening Communication function: RS-485 (9pins D-sub) or USB (Type-B) Half-duplex bit serial Start-stop synchronization ModbusTM protocol Contents : Read/Write parameters Read m easurement c oncentration a nd i nstrument status Remark : hen c onnecting v ia R SW 232C interface, an RS-232C ↔ RS-485 converter should be used. Performance ±0.5% of full scale ±1% of full scale ±2% of full scale/week In the case of auto zero calibration use for 500 ppm or less range Span drift: ±2% of full scale/week Response time (for 90% FS response) : 1 to 15 sec electrical response W ithin 60 seconds including replacement ime of sampling gas (when gas flow rate is 0.5L/min) Gas replacement time depends on the number of measuring components,and measuring range. Repeatability: Linearity: Zero drift: 3 ZRE Interference from other gases: Interference CO2 component analyzer CO 1000ppm CO2 15% ≤1%FS CO analyzer –– ≤1%FS for 200ppm analyzer, ≤2.5%FS ≤1%FS for 500ppm analyzer, ≤2.5%FS ≤2.5%FS for 200ppm analyzer ≤1%FS CH4 analyzer ≤1%FS SO2 analyzer ≤1%FS NO analyzer ≤1%FS Standard Requirements for Sample Gas 0.5L / min ±0.2L / min 0 to 50˚C 10 kPa or less (Gas outlet side should be open to the atmospheric air.) Dust: 100 µg/Nm3 or less in particle size of 0.3 µm or less Mist: Unallowable Moisture: Below a level where saturation occurs at room temperature (condensation unallowable). Below the level where saturation occurs at 2˚C for CO measurement in 0 to 200 ppm range, NO measurement, and SO2 measurement. Corrosive component: 1 ppm or less Standard gas for calibration: Zero gas ; Dry N2 Span gas ; ach sample gas having conE centration 90 to 100% of its m easuring r ange ( recommended). In case a zirconia O2 analyzer is installed externally and calibration is carried out on the same calibration gas line: Zero gas ; Dry air or atmospheric air Span gas ; For other than O2 measurement, each sample gas having concentration 90 to 100% of its measuring range For O2 measurement, O2 gas of 1 to 2 vol%/remains N2 gas Flow rate: Temperature: Pressure: –– ≤1%FS ≤1%FS ≤1%FS H2O saturation at 20°C H2O saturation at 2°C CH4 1000ppm ≤1%FS ≤1%FS –– –– –– –– ≤2%FS ≤2%FS ≤1%FS –– ≤50ppm –– EC Directive Compliance The product conforms to the requirements of the Low Voltage Directive 2006/95/EC and EMC directive 89/336/EEC (as amended by Directive 92/31/EEC), both as amended by Directive 93/68/EEC. It conforms to following standards for product safety and electromagnetic compatibility ; EN61010-1 : 2001 Safety requirements for electrical equipment for measurement, control and laboratory use. “Installation Category II” “Pollution Degree 2” EN61326-1 : 1997, AI: 1998, A2: 2001, A3: 2003 Electrical equipment for measurement, control and laboratory use — EMC requirements. Installation Requirements • Indoor use (Select a place where the equipment does not receive direct sunlight, draft/rain or radiation from hot substances. If such a place cannot be found, a roof or cover should be prepared for protection.) • Avoid a place where unit receives heavy vibration • Select a place where atmospheric air is clean Principle diagram of NDIR type measurement (For CO2, CO, CH4, SO2, NO) Front expansion chamber Infrared-ray light source Gas inlet Gas outlet Rear expansion chamber Detector Mass flow sensor Preamplifier Signal processing and calculation block Principle diagram of fuel cell type measurment (For O2) Principle diagram of paramagnetic type measurment (For O2) Permanent magnet Mirror Dumb-bell Gas inlet Resistor Thermistor Magnetic field Gas outlet Electrolyte Negative electrode Permanent magnet Photo diode Light emitting diode Indication Positive electrode Diaphragm Output Measuring cell Preamplifier Motor Chopper Measuring cell Indication Signal processing and calculation block Output 4 Examples of sampling system configuration including gas analyzer To measure low moisture content (saturated at room temperature or lower) sample gas (CO, CO2, CH4) 9 1 Flow meter 10 Mist filter 3 Pump 7 Membrane filter Two-way Solenoid valve 7 7 7 Solenoid valve 5 Drain pot 11 6 Gas analyzer (ZRE) Demister O2 analyzer Ball valve 6 Ball valve Reference gas for zero calibration 8 Reference gas for span calibration Drain (In the case of zirconia type) Exhaust (atmospheric pressure) To measure high moisture content sample gas, NO, SO2, or CO (0 to 200 ppm range) 13 1 Mist filter 3 Pump Solenoid valve 9 Flow meter 10 Membrane filter 3 Pump *2) Atmospheric (Air) 7 Two-way Solenoid valve 12 7 7 7 NOX/NO converter (for NOX measurement) Solenoid valve *1) 2 4 Electronic cooler 5 Safety drain trap Gas analyzer (ZRE) O2 analyzer Drain pot Ball valve 6 Drain Reference gas for zero calibration 8 Reference gas for span calibration (In the case of zirconia type) Exhaust (atmospheric pressure) *1) Be sure to use a dehumidifier such as electronic cooler for NO, SO2, and CO analyzers of 0 to 200 ppm range (=2ºC saturation or lower). *2) Be sure to use auto zero calibration, in the case of 500 ppm or less range. List of sampling devices (example) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 Device name Mist filter Safety drain trap Pump Electoric cooler Drain pot Ball valve Two-way solenoid valve Standard gas for calibration Flow meter Membrane filter Demister NO2/NO converter Three-way solenoid valve ZBM Y04-0 (Codes in ZBBK1V03-0 ZBH51603 ZBG80 ZBC91003 ZBH13003 (Length 255mm) ZBFB1 Fuji’s type to be selected depending on application) ZBD42203 ZBBM2V03-0 ZBH35003 ZDL02001 Note) The above is a typical configuration example. As configuration may differ depending on measuring objects, please consult us. 5 ZRE CODE SYMBOLS 12345678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Description Digit 4 Fuji Standard 19 inch housing 5 19-inch rack mounting type EIA conformity 19-inch rack mounting type JiS conformity Panel mounting type 6 1st component 2nd component 3rd component 4th component None NO SO2 CO2 CO CH4 NO SO2 NO CO CO2 CO CH4 CO CO2 CH4 NO SO2 CO CO2 CO CH4 NO SO2 CO2 CO Others 7 None External O2 analyzer External zirconia O2 sensor (ZFK7) Built-in fuel cell O2 sensor Built-in paramagnetic O2 sensor 8 9 1st component, 1st range 10 1st component, 2nd range 11 2nd component, 1st range 12 2nd component, 2nd range 13 3rd component, 1st range 14 3rd component, 2nd range 15 4th component, 1st range 16 4th component, 2nd range 17 None 0-5/10% 0-5/25% 0-10/25% 0-5% 0-10% 0-25% 0-50% 0-100% Others 18 Rc1/4 NPT1/4 19 DC0-1V DC4-20mA DC0-1V+Communication function DC4-20mA+Communication function 20 Janpanese English Chinese 21 None O2 correction O2 correction and O2 correction average 22 FAULT A. Cal. H/L Alarm RangeID/Remote range None note ZRE A B C D Y P A D B E F G J K L N T V Z Y 1 2 3 4 1 Y Digit note1 note2 note3 note4 note4 note4 note4 note4 note4 note4 note4 1 Y A B C L M V P R Z 1 2 A B C D J E C Y A C Y A B C D E F G H note5 note6 note1 6 12345678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Description Digit 24 ppm, % mg/m3, g/m3 25 For standard For heat treatment furnace For steel converter furnace Others 26 None standard Range None 0-100ppm 0-200ppm 0-250ppm 0-300ppm 0-500ppm 0-1000ppm 0-2000ppm 0-2500ppm 0-3000ppm 0-5000ppm 0-1% 0-2% 0-3% 0-5% 0-10% 0-20% 0-25% 0-40% 0-50% 0-70% 0-100% Others Code Y B C D S E F G U T H J K Q L M N V W P X R Z note note7 ZRE 1 Y A B A C D Z Z Digit note8 note1) A. Cal. must be specified at 22nd digit, in the case of 500 ppm or less range. “ ” note2) hen only O2 measurement is necessary, “Y” should be specified at the 6th digit. W note3) hen “1” is specified at 7th digit, O2 pt sensor signal has to be set as 0-1V DC linear corresponding to full scale. W External zirconia O2 sensor and external O2 analyzer are not included in the scope of supply, and has to be separately ordered. note4) efer to Tables 1 for possible combination of measuring components and ranges in the data sheet. R When “Y” is specified at 6th digit, “Y” should be specified at 9th to 16th digit. note5) 2 correction is calculated only for NO, SO2 and CO O note6) hen 5 components measurement is specified, “H” must not be specified at 22nd digit. W When 4 components measurement is specified and “H” is specified at 22nd digit, 3 point is maximum for alarm output function. note7) hen “B” is specified at 24th digit, measuring range should be specified by ppm range code. W In this case NO,SO2 and CO measuring range are corresponding range in mg/m3. . Please refer to the t able shown below for the corresponding range code based on “mg/m3” note8) hen A to D is specified on the 25th digit, the analyzer will be adjusted and delivered with the following gasses. W Standard “A”: balance gas N2 For heat treatment furnace “C”: balance gas 30%H2 / remains N2 For converter “D”: balance gas CO, CO2 When other adjustment is required, please specify “Z” , When “Z” is specified, please attach a list of gas composition contained in the measuring gas. Corresponding mg/m3 Range code C D S E F G U T H Unit : ppm 0-200ppm 0-250ppm 0-300ppm 0-500ppm 0-1000ppm 0-2000ppm 0-2500ppm 0-3000ppm 0-5000ppm Corresponding range in mg/m3 NO SO2 CO 0-260mg/m3 0-250mg/m3 0-570mg/m3 0-325mg/m3 0-700mg/m3 0-300mg/m3 0-400mg/m3 0-850mg/m3 0-375mg/m3 0-650mg/m3 0-1400mg/m3 0-600mg/m3 0-1300mg/m3 0-2800mg/m3 0-1250mg/m3 0-2600mg/m3 0-5600mg/m3 0-2500mg/m3 0-3300mg/m3 0-7100mg/m3 0-3000mg/m3 0-4000mg/m3 0-8500mg/m3 0-3750mg/m3 0-6600mg/m3 0-14.00g/m3 0-6250mg/m3 The conversion formula "ppm" unit into "mg/m3" unit. NO (mg/m3) = 1.34 × NO (ppm) SO2 (mg/m3) = 2.86 × SO2 (ppm) CO (mg/m3) = 1.25 × CO (ppm) 7 ZRE Table 1 Measurable component and range - availability check table Procedure of range selection On one component analyzer: First determine 1st range, then select 2nd range from the right of your determination range in following t ables. More than t wo components: The procedure is same as one component. Difference is 2nd range in the t ables. The 2nd range in the t ables for t wo and more components is maximum available range. 2nd range is selectable from 1st range to 2nd range(max) on the t able. 1-component analyzer : CO 1st range 0 - 200ppm 0 - 250ppm 0 - 300ppm 0 - 500ppm 0 - 1000ppm 0 - 2000ppm 0 - 2500ppm 0 - 3000ppm 0 - 5000ppm 0 - 1% 0 - 2% 0 - 3% 0 - 5% 0 - 10% 0 - 20% 0 - 25% 0 - 40% 0 - 50% 0 - 70% 0 - 100% 2nd range None, 0 - 250ppm,300ppm,500ppm,1000ppm,2000ppm None, 0 - 300ppm,500ppm,1000ppm,2000ppm,2500ppm None, 0 - 500ppm,1000ppm,2000ppm,2500ppm None, 0 - 1000ppm,2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2000ppm,2500ppm,3000ppm,5000ppm,1% None, 0 - 2500ppm,3000ppm,5000ppm,1%,2% None, 0 - 3000ppm,5000ppm,1%,2% None, 0 - 5000ppm,1%,2% None, 0 - 1%,2%,3%,5% None, 0 - 2%,3%,5%,10% None, 0 - 3%,5%,10%,20% None, 0 - 5%,10%,20%,25% None, 0 - 10%,20%,25%,40%,50% None, 0 - 20%,25%,40%,50%,70%,100% None, 0 - 25%,40%,50%,70%,100% None, 0 - 40%,50%,70%,100% None, 0 - 50%,70%,100% None, 0 - 70%,100% None, 0 - 100% None 1-component analyzer : NO 1st range 0 - 200ppm 0 - 250ppm 0 - 300ppm 0 - 500ppm 0 - 1000ppm 0 - 2000ppm 0 - 2500ppm 0 - 3000ppm 0 - 5000ppm 1st range 0 - 200ppm 0 - 250ppm 0 - 300ppm 0 - 500ppm 0 - 1000ppm 0 - 2000ppm 0 - 2500ppm 0 - 3000ppm 0 - 5000ppm 0 - 1% 0 - 2% 0 - 3% 0 - 5% 0 - 10% 1st range 0 - 500ppm 0 - 1000ppm 0 - 2000ppm 0 - 2500ppm 0 - 3000ppm 0 - 5000ppm 0 - 1% 0 - 2% 0 - 3% 0 - 5% 0 - 10% 0 - 20% 0 - 25% 0 - 40% 0 - 50% 0 - 70% 0 - 100% 2nd range None, 0 - 250ppm,300ppm,500ppm,1000ppm,2000ppm None, 0 - 300ppm,500ppm,1000ppm,2000ppm,2500ppm None, 0 - 500ppm,1000ppm,2000ppm,2500ppm None, 0 - 1000ppm,2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2500ppm,3000ppm,5000ppm None, 0 - 3000ppm,5000ppm None, 0 - 5000ppm None 2nd range None, 0 - 250ppm,300ppm,500ppm,1000ppm,2000ppm None, 0 - 300ppm,500ppm,1000ppm,2000ppm,2500ppm None, 0 - 500ppm,1000ppm,2000ppm,2500ppm None, 0 - 1000ppm,2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2000ppm,2500ppm,3000ppm,5000ppm,1% None, 0 - 2500ppm,3000ppm,5000ppm,1%,2% None, 0 - 3000ppm,5000ppm,1%,2% None, 0 - 5000ppm,1%,2% None, 0 - 1%,2%,3%,5% None, 0 - 2%,3%,5%,10% None, 0 - 3%,5%,10% None, 0 - 10% None, 0 - 10% None 2nd range None, 0 - 1000ppm,2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2000ppm,2500ppm,3000ppm,5000ppm,1% None, 0 - 2500ppm,3000ppm,5000ppm,1%,2% None, 0 - 3000ppm,5000ppm,1%,2% None, 0 - 5000ppm,1%,2% None, 0 - 1%,2%,3%,5% None, 0 - 2%,3%,5%,10% None, 0 - 3%,5%,10%,20% None, 0 - 5%,10%,20%,25% None, 0 - 10%,20%,25%,40%,50% None, 0 - 20%,25%,40%,50%,70%,100% None, 0 - 25%,40%,50%,70%,100% None, 0 - 40%,50%,70%,100% None, 0 - 50%,70%,100% None, 0 - 70%,100% None, 0 - 100% None 1-component analyzer : SO2 1-component analyzer : CO2 1st range 0 - 100ppm 0 - 200ppm 0 - 250ppm 0 - 300ppm 0 - 500ppm 0 - 1000ppm 0 - 2000ppm 0 - 2500ppm 0 - 3000ppm 0 - 5000ppm 0 - 1% 0 - 2% 0 - 3% 0 - 5% 0 - 10% 0 - 20% 0 - 25% 0 - 40% 0 - 50% 0 - 70% 0 - 100% 2nd range None, 0 - 200ppm,250ppm,300ppm,500ppm,1000ppm None, 0 - 250ppm,300ppm,500ppm,1000ppm,2000ppm None, 0 - 300ppm,500ppm,1000ppm,2000ppm,2500ppm None, 0 - 500ppm,1000ppm,2000ppm,2500ppm None, 0 - 1000ppm,2000ppm,2500ppm,3000ppm,5000ppm None, 0 - 2000ppm,2500ppm,3000ppm,5000ppm,1% None, 0 - 2500ppm,3000ppm,5000ppm,1%,2% None, 0 - 3000ppm,5000ppm,1%,2% None, 0 - 5000ppm,1%,2% None, 0 - 1%,2%,3%,5% None, 0 - 2%,3%,5%,10% None, 0 - 3%,5%,10%,20% None, 0 - 5%,10%,20%,25% None, 0 - 10%,20%,25%,40%,50% None, 0 - 20%,25%,40%,50%,70%,100% None, 0 - 25%,40%,50%,70%,100% None, 0 - 40%,50%,70%,100% None, 0 - 50%,70%,100% None, 0 - 70%,100% None, 0 - 100% None 1-component analyzer : CH4 2-component analyzer : NO/SO2 1-component : NO 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None 2-component : SO2 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None 2-component analyzer : NO/CO 1-component : NO 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None 2-component : CO 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None • The 2nd component should be selected as shown in the right table. • The 2nd component should be selected as shown in the right table. 8 2-component analyzer:CO2/CO 2-component:CO 1-component:CO2 1st range 2nd range (max.) 1st range/2nd range (max.) 0-100ppm 0-1000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/2500ppm, 0-1000/2500ppm, 0-2000/2500ppm, 0-2500ppm 0-200ppm 0-2000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm 0-2500/5000ppm, 0-3000ppm/2%, 0-5000ppm/3%, 0-1/3%, 0-2/3%, 0-250ppm 0-2500ppm 0-3% 0-300ppm 0-500ppm 0-500ppm 0-5000ppm 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-2500/5000ppm, 0-3000ppm/2%, 0-5000ppm/3%, 0-1/3%, 0-2/3%, 0-3% 0-1000ppm 0-5000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-2000ppm 0-3/10%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-1000ppm 0-1% 0-500/5000ppm , 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/10%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-2000ppm 0-1% 0-500/5000ppm , 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-2000ppm 0-2% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-2500ppm 0-1% 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-2500ppm 0-2% 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-3000ppm 0-1% 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-3000ppm 0-2% 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/25%, 0-10/100%,0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5000ppm 0-3% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-1% 0-5% 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-5% 0-5000ppm 0-5% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-1% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-20% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-3% 0-25% 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5% 0-50% 0-10% 0-100% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-20% 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-25% 0-40% 0-50% 0-70% 0-100% None 2-component analyzer:CH4/CO 2-component:CO 1-component:CH4 1st range 2nd range (max.) 1st range/2nd range (max.) 0-500ppm 0-5000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/2500ppm, 0-1000/2500ppm, 0-2000/2500ppm 0-1000ppm 0-5000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-2500/5000ppm, 0-3000/5000ppm 0-1000ppm 0-1% 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-2500/5000ppm, 0-3000/5000ppm 0-2000ppm 0-5000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20% 0-2500ppm 0-5000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1% 0-3000ppm/1%, 0-3000ppm 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/25% 0-2000ppm 0-1% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20% 0-2500ppm 0-1% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/25% 0-3000ppm 0-2000ppm 0-2% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20% 0-2500ppm 0-2% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/25% 0-3000ppm 0-5000ppm 0-1% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-5000ppm 0-3% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-5000ppm 0-5% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5% 0-2/5%, 0-3/25%, 0-5/25%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-1% 0-5% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1% ,0-3000ppm/1%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-1% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1% ,0-3000ppm/1%, 0-5000ppm/1%, 0-1/10%, 0-2/10%, 0-3/10%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-20% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-3% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-3% 0-25% 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5% 0-25% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5% 0-50% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/5%, 0-2/5%, 0-3/25%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-10% 0-50% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-10% 0-100% 0-5000ppm/5%, 0-1/10%, 0-2/10%, 0-3/10%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-20% 0-50% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-25% 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-40% 0-20% 0-100% 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-25% 0-40% 0-50% 0-70% 0-100% None 9 ZRE 2-component analyzer:CO2/CH4 2-component:CH4 1-component:CO2 1st range 2nd range (max.) 1st range/2nd range (max.) 0-100ppm 0-1000ppm 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-2500/5000ppm, 0-3000/5000ppm, 0-5000ppm 0-200ppm 0-2000ppm 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/1%, 0-5000ppm/1%, 0-1% 0-250ppm 0-2500ppm 0-300ppm 0-2500ppm 0-500ppm 0-2500ppm 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/2%, 0-2/10%, 0-3/10%, 0-5/10%, 0-10% 0-500ppm 0-5000ppm 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/2%, 0-2/10%, 0-3/10%, 0-5/10%, 0-10% 0-1000ppm 0-2500ppm 0-500/5000ppm0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/3%, 0-1/3%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-1000ppm 0-5000ppm 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/3%, 0-1/3% 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-1000ppm 0-1% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/3%, 0-1/3%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-2000ppm 0-2500ppm 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-2000ppm 0-5000ppm 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-2000ppm 0-2% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/20%, 0-20% 0-2500ppm 0-5000ppm 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/25%, 0-10/25%, 0-20/25%, 0-25% 0-2500ppm 0-2% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5%, 0-2/20%, 0-3/20%, 0-5/25%, 0-10/25%, 0-20/25%, 0-25% 0-3000ppm 0-2% 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/5% 0-2/20%, 0-3/20%, 0-5/25%, 0-10/25%, 0-20/25%, 0-25% 0-5000ppm 0-3% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-5000ppm 0-5% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/20%, 0-5/20%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-1% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/50%, 0-25/50%, 0-40/50%, 0-50% 0-2% 0-20% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/10%, 0-3/10%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-10% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-3% 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-3% 0-25% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5% 0-20% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-5% 0-50% 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-10% 0-20% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-10% 0-50% 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-20% 0-50/100%, 0-70/100%, 0-100% 0-25% 0-40% 0-10% 0-100% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/10%, 0-3/10%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-20% 0-100% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/10%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-25% 0-100% 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/2%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-40% 0-70/100%, 0-100% 0-50% 0-70% 0-100% None 3-component analyzer:NO/SO2/CO 1-component:NO 1st range 2nd range (max.) 0-200ppm 0-2000ppm 0-250ppm 0-2500ppm 0-300ppm 0-2500ppm 0-500ppm 0-5000ppm + 0-1000ppm 0-5000ppm 0-2000ppm 0-5000ppm 0-2500ppm 0-5000ppm 0-3000ppm 0-5000ppm 0-5000ppm None >>> Combination of 1st component NO and 2nd component SO2 / 3rd component CO 2-component:SO2 3-component:CO 1st range 2nd range (max.) 1st range/2nd range (max.) 0-200ppm 0-2000ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/2500ppm, 0-1000/2500ppm, 0-2000/2500ppm, 0-2500ppm 0-250ppm 0-2500ppm 0-300ppm 0-500ppm 0-2500ppm 0-200/2000ppm, 0-250/2500ppm, 0-300/2500ppm, 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-5000ppm 0-1000ppm 0-2500ppm None 0-1000ppm 0-5000ppm 0-500/5000ppm, 0-1000/5000ppm, 0-2000/5000ppm, 0-2500/5000ppm, 0-3000/5000ppm, 0-5000ppm 0-2000ppm 0-2500ppm 0-3000ppm 0-5000ppm None 3-component analyzer:CO2/CO/CH4 >>> Combination of 1st component CO2 / 2nd component CO and 3rd component CH4 1-component:CO2 2-component:CO 3-component:CH4 1st range 2nd range (max.) 1st range/2nd range (max.) 1st range 2nd range (max.) 0-5000ppm 0-5% 0-5000ppm 0-3% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-1% 0-5% 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-5% 0-5000ppm 0-5% 0-500/5000ppm, 0-1000ppm/1%, 0-2000ppm/2%, 0-2500ppm/2%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, + 0-1% 0-10% 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-2% 0-20% 0-1% 0-10% 0-500/5000ppm , 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/25%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-3% 0-25% 0-2% 0-20% 0-500/5000ppm , 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-5% 0-10% 0-3/25%, 0-5/50%, 0-10/50%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-10% 0-20% 0-2% 0-10% 0-500/5000ppm , 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3% 0-25% 0-3/25%, 0-5/50%, 0-10/100%, 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-20% 0-25% 0-5% 0-50% 0-25% 0-40% 0-10% 0-100% 0-1000ppm/1%, 0-2000ppm/1%, 0-2500ppm/1%, 0-3000ppm/2%, 0-40% 0-50% 0-20% 0-5000ppm/5%, 0-1/10%, 0-2/20%, 0-3/25%, 0-5/50%, 0-10/100%, 0-25% 0-20/100%, 0-25/100%, 0-40/100%, 0-50/100%, 0-70/100%, 0-100% 0-50% 0-70% 0-40% 0-50% 0-70% 0-100% 0-70% 0-100% None 0-100% None Availability of product Product available only when CO analyzer max. measuring range is 50% or less Product available Product available only when CO analyzer measuring range is 0 to 1000ppm or more. Product available only when CO analyzer measuring range is 0 to 5000ppm or more. Product available only when CO analyzer measuring range is more than 5000ppm or CO2 analyzer range is more than 2%. 10 4-component analyzer : NO/SO2/CO2/CO 1-component : NO 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None 2-component : SO2 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 5000ppm 0 - 1000ppm 0 - 5000ppm 0 - 2000ppm 0 - 5000ppm 0 - 2500ppm 0 - 5000ppm 0 - 3000ppm 0 - 5000ppm 0 - 5000ppm None 3-component : CO2 1st range 2nd range (max.) 0 - 1% 0 - 10% 0 - 2% 0 - 20% 0 - 3% 0 - 25% 0 - 5% 0 - 50% 0 - 10% 0 - 50% 0 - 20% 0 - 50% 0 - 25% 0 - 50% 0 - 25% 0 - 50% 0 - 50% None 4-component : CO 1st range 2nd range (max.) 0 - 200ppm 0 - 2000ppm 0 - 250ppm 0 - 2500ppm 0 - 300ppm 0 - 2500ppm 0 - 500ppm 0 - 2500ppm 0 - 1000ppm 0 - 2500ppm 0 - 2000ppm 0 - 2500ppm 0 - 2500ppm None Table 2 Channel (Ch) No. and display/output contents comparison table Code symbol 6th digit 7th digit 21st digit Y 1 to 3 Y P Y Y A Y Y D Y Y B Y Y E Y Y F Y Y G Y Y J Y Y K Y Y L Y Y N Y Y T Y Y V Y Y P 1 to 3 Y A 1 to 3 Y D 1 to 3 Y B 1 to 3 Y E 1 to 3 Y F 1 to 3 Y G 1 to 3 Y J 1 to 3 Y K 1 to 3 Y L 1 to 3 Y N 1 to 3 Y T 1 to 3 Y V 1 to 3 Y P 1 to 3 A* A 1 to 3 A* B 1 to 3 A* F 1 to 3 A* G 1 to 3 A* J 1 to 3 A* N 1 to 3 A* V 1 to 3 A* P 1 to 3 C* A 1 to 3 C* B 1 to 3 C* F 1 to 3 C* G J N V 1 to 3 1 to 3 1 to 3 1 to 3 C* C* C* C* Display/output contents Ch1:O2 Ch1:NO Ch1:SO2 Ch1:CO2 Ch1:CO Ch1:CH4 Ch1:NO, Ch2:SO2 Ch1:NO, Ch2:CO Ch1:CO2, Ch2:CO Ch1:CH4, Ch2:CO Ch1:CO2, Ch2:CH4 Ch1:NO, Ch2:SO2, Ch3:CO Ch1:CO2, Ch2:CO, Ch3:CH4 Ch1:NO, Ch2:SO2, Ch3:CO2, Ch4:CO Ch1:NO, Ch2:O2 Ch1:SO2, Ch2:O2 Ch1:CO2, Ch2:O2 Ch1:CO, Ch2:O2 Ch1:CH4, Ch2:O2 Ch1:NO, Ch2:SO2, Ch3:O2 Ch1:NO, Ch2:CO, Ch3:O2 Ch1:CO2, Ch2:CO, Ch3:O2 Ch1:CH4, Ch2:CO, Ch3:O2 Ch1:CO2, Ch2:CH4, Ch3:O2 Ch1:NO, Ch2:SO2, Ch3:CO, Ch4:O2 Ch1:CO2, Ch2:CO, Ch3:CH4, Ch4:O2 Ch1:NO, Ch2:SO2, Ch3:CO2, Ch4:CO, Ch5:O2 Ch1:NOx, Ch2:O2, Ch3:corrected NOx Ch1:SO2, Ch2:O2, Ch3:corrected SO2 Ch1:CO, Ch2:O2, Ch3:corrected CO Ch1:NOx, Ch2:SO2, Ch3:O2, Ch4:corrected NOx, Ch5:corrected SO2 Ch1:NOx, Ch2:CO, Ch3:O2, Ch4:corrected NOx, Ch5:corrected CO Ch1:CO2, Ch2:CO, Ch3:O2, Ch4:corrected CO Ch1:NOx, Ch2:SO2, Ch3:CO, Ch4:O2, Ch5:corrected NOx, Ch6:corrected SO2, Ch7:corrected CO Ch1:NOx, Ch2:SO2, Ch3:CO2, Ch4:CO, Ch5:O2, Ch6:corrected NOx, Ch7:corrected SO2, Ch8:corrected CO Ch1:NOx, Ch2:O2, Ch3:corrected NOx, Ch4:corrected NOx average Ch1:SO2, Ch2:O2, Ch3:corrected SO2, Ch4:corrected SO2 average Ch1:CO, Ch2:O2, Ch3:corrected CO, Ch4corrected CO average Ch1:NOx, Ch2:SO2, Ch3:O2, Ch4:corrected NOx, Ch5:corrected SO2, Ch6:corrected NOx average, Ch7:corrected SO2 average Ch1:NOx, Ch2:CO, Ch3:O2, Ch4:corrected NOx, Ch5:corrected CO, Ch6:corrected NOx average, Ch7:corrected CO average Ch1:CO2, Ch2:CO, Ch3:O2, Ch4:corrected CO, Ch5:corrected CO average Ch1:NOx, Ch2:SO2, Ch3:CO, Ch4:O2, Ch5:corrected NOx, Ch6:corrected SO2, Ch7:corrected CO, Ch8:corrected NOx average, Ch9:corrected SO2 average, Ch10:corrected CO average Ch1:NOx, Ch2:SO2, Ch3:CO2, Ch4:CO, Ch5:O2, Ch6:corrected NOx, Ch7:corrected SO2, Ch8:corrected CO, Ch9:corrected NOx average, Ch10:corrected SO2 average2, Ch11:corrected CO average * When the 21st digit code is A or C, the component of the NO analyzer is displayed as NOx. 11 ZRE OUTLINE DIAGRAMS (Unit : mm) 378.5 399.5 132.5 18.5 19-inch rack mounting plate ZRE- GAS ANALYZER MODE ZERO SPAN Power Switch FL1 FL2 ENTER 397 ESC POWER Digital input/output connector (DIO 1 to 3) Analog output connector (A/O) Communication connector (RS485) Analog external input connector (A/I) 483 443 Purge gas inlet Rc1/4 or NPT1/4 Sample gas inlet 1 Rc1/4 or NPT1/4 Sample gas outlet 1 Rc1/4 or NPT1/4 DIO3 RS485 A/I Made in Japan 7 A/O ‚o‚t‚q‚f‚d ‚h‚m‚k‚d‚s‚P ‚n‚t‚s‚k‚d‚s‚P A INFRARED?@GAS?@ANALYZER TYPE 00000- 124.5 Dimension A JIS 50mm EIA 57.2mm DIO2 ‚h‚m‚k‚d‚s‚Q ‚n‚t‚s‚k‚d‚s‚Q U SE OUTPUT DC POWER AC100V?`AC240V 50/60 Hz SER.NO. MFD Fuji Electric Co.,Ltd. VA DIO1 FUSE 250V T 2A Note 1) Sample gas inlet 2 Rc1/4 or NPT1/4 Note 1) Sample gas outlet 2 Rc1/4 or NPT1/4 435 Note 1) Used for special case. Power terminal (M4) 12 F Mounting method The analyzer weight should be supported at the bottom of the case. Panel mounting type 19-inch rack mounting type 126 +2 -0 436 +2 -0 450 or more 465 Mounting bracket Mounting diagram Support 260 or more * 70% or more of the analyzer weight should be supported at the bottom of the case. (In case of mounting panel or 19-inch rack provide a support at the end of casing.) Guide rails 124.5 Guide rails EXTERNAL CONNECTION A/O connector 13 1 1 14 2 AO1+ AO1AO2+ AO2AO3+ AO3AO4+ AO4AO5+ AO5AO6+ AO6AO7+ AO7AO8+ AO8AO9+ AO9AO10+ AO10AO11+ AO11AO12+ AO12NC 5 1 1 6 2 A Dimension A JIS standerd : 50mm EIA standerd : 57.2mm (GND) RT×D+ 7 25 14 3 15 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13 9 6 3 RT×D8 D-sub 25pins female * In standard, displayed Channel No. and Analog Output No. are same. D-sub 9pins female 4 9 5 A/I connector (O2 signal input) AI- P N L 100 to 240V AC AI+ 13 ZRE DIO 1 to 3 connector (option) 13 1 1 14 2 15 3 16 4 17 5 18 6 19 7 20 DIO1 DIO2 DIO3 connector connector connector DI1+ DI1DI2+ DI2DI3+ DI3NC com NO NC com NO NC com NO NC com NO NC com NO DO1 DO2 DO3 DO4 DO5 DI4+ DI4DI5+ DI5DI6+ DI6DO6 DO7 DO8 DO9 DO10 DI7+ DI7DI8+ DI8DI9+ DI9DO11 DO12 DO13 DO14 DO15 Digital output max. contact load rating 24V DC/1A Digital input OFF : 0V ON : 12 to 24V DC 25 14 D-sub 25pins female * DIO 1 to 3 are all as same connector. Contents of digital input signal DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 Remote hold Average value reset A. cal. start A. zero. cal. start Remote range Ch1 Remote range Ch2 Remote range Ch3 Remote range Ch4 Remote range Ch5 8 21 9 22 10 23 11 24 12 25 13 Contents of digital output signal Independent on the number of component 1-component analyzer B,E Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) Range identification Ch1 (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) 4-component analyzer (Range identification Ch1) (Range identification Ch2) (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) D,F,G,H Instrument error Calibration error (A.cal.status) (For zero gas) (For span gas Ch1) 2-component analyzer 3-component analyzer B,D,E,F,G,H Instrument error Calibration error (A.cal.status) (For zero gas) (For span gas Ch1) (For span gas Ch2) B,D,E,F,G,H Instrument error Calibration error (A.cal.status) (For zero gas) (For span gas Ch1) (For span gas Ch2) (For span gas Ch3) (Range identification Ch1) (Range identification Ch2) (Range identification Ch3) (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) 5-component analyzer G Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 For span gas Ch2 For span gas Ch3 For span gas Ch4 H Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 For span gas Ch2 For span gas Ch3 For span gas Ch4 Range identification Ch1 Range identification Ch2 (Alarm1) Range identification Ch1 Range identification Ch2 Range identification Ch3 Range identification Ch4 (Alarm2) (Alarm3) Range identification Ch3 Range identification Ch4 (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) B,E Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 For span gas Ch2 Range identification Ch1 For span gas Ch3 Range identification Ch2 For span gas Ch4 Range identification Ch3 For span gas Ch5 Range identification Ch4 Range identification Ch5 (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) Range identification Ch1 Range identification Ch2 Range identification Ch3 Range identification Ch4 Range identification Ch5 D,F Instrument error Calibration error G Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 For span gas Ch2 For span gas Ch3 For span gas Ch4 For span gas Ch5 22th digit DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10 DO11 DO12 DO13 DO14 DO15 A,C Instrument error Calibration error The items in the parentheses may not be available depending on the selected type on 22th digit. The normal open side (NO) of digital output is close when the function is active without range ID. In case of range ID, normal open (NO) side is close with Lo-range. The normal close (NC) side is close with Hi-range. 22th digit DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10 DO11 DO12 DO13 DO14 DO15 B,E Instrument error Calibration error A.cal.status For zero gas For span gas Ch1 For span gas Ch2 D,F Instrument error Calibration error For span gas Ch3 Range identification Ch1 For span gas Ch4 Range identification Ch2 Range identification Ch3 Range identification Ch4 (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) (Alarm1) (Alarm2) (Alarm3) (Alarm4) (Alarm5) SCOPE OF DELIVERY • Gas analyzer … 1 unit • Replacement fuse (250V, 2A AC, delay type) … 2 pcs • Instruction manual … 1 copy • Connector for I/O connection … 1 set • Panel mounting fixtures (in case panel mounting) … 2 pcs ORDERING INFORMATION 1. Code symbols 2. Application and composition of sample gas 14 Exclusive Zirconia O2 Sensor (to be purchased separately) For O2 correction, the gas analyzer ZRE can accept linearized 0 to 1V DC signal coming from analyzer calibrated 0 to 25% O2 full scale. If the analyzer is not available, Fuji can supply exclusive Zirconia O2 sensor Model ZFK. Measuring method: Zirconia system Measurable component and measuring range: Measurable component O 2 Oxygen Range 0 to 25vol% CODE SYMBOLS 12345678 9 10 11 12 13 ZFK7YY 7YY 9 B C 4- Y0YY Description Measuring method Zirconia method Power supply 100 to 115V AC 50/60Hz(Standard) 200 to 240V AC 50/60Hz(Standard) 200 to 240V AC 50/60Hz(CE mark) 1 8 Gas inlet/outlet size Rc 1/4 NPT 1/4 Repeatability: Within ± 0.5% of full scale Linearity: Within ± 1% of full scale Zero drift: Within ± 1% of full scale/week Span drift: Within ± 2% of full scale/week Response time: Approx. 20 seconds (for 90% response) Measured gas flow rate: 0.5 ± 0.25L / min Remark: The Zirconia system, due to its principle, may produce a measuring error due to relative concentration versus the combustible O2 gas concentration. Also, a corrosive gas (SO2 of 250 ppm or more, etc.) may affect the life of the sensor. ; 100 to 115V AC or 200 to 240V AC Rated frequency ; 50Hz/60Hz Max. rated power ; 215VA ( during p ower ON) 65VA ( during s teadystate operation) Enclosure: Steel casing, for indoor application Indication: Temperature indication (LED) Temperature alarm output: Contact output 1a contact, Contact capacity 220V, 1A AC (resistive load) Outer dimensions (H x W x D): 141 x 170 x 190mm Mass {weight}: Approx. 3kg Finish color: Munsell 5Y 7/1 Gas inlet/outlet size: Rc1/4 or NPT1/4 Power supply: Rated voltage 15 ZRE OUTLINE DIAGRAM 4 (Unit:mm) 170 152 OXYGEN ANALYZER TEMP. 131 141 F US AC250V T3.15A 1 2 3 4 5 6 7 L N AC INPUT OUT ALM 110 E ø5 17 9TH DIGIT 1: RC1/4 8: NPT1/4 INLET OUTLET INLET 37 23 OUTLET 48 EXTERNAL CONNECTION DIAGRAM 1 2 3 + AC power supply E 4 5 Output Temperature to analyzer alarm output 6 7 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan 172.5
EDS3-133F 价格&库存

很抱歉,暂时无法提供与“EDS3-133F”相匹配的价格&库存,您可以联系我们找货

免费人工找货