0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS5-88

EDS5-88

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS5-88 - OPTICAL ABSOLUTE PRESSURE TRANSMITTER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS5-88 数据手册
FFI SYSTEM OPTICAL ABSOLUTE PRESSURE TRANSMITTER DATA SHEET The Model FBK 3 Optical Absolute Pressure Transmitter measures absolute pressures of various fluids accurately, converts them into optical digital signals and outputs them. This is an intelligent transmitter providing excellent performance and functions due to incorporation of electrostatic capacitance type silicon sensor and microprocessor. A fiber optical cable used for the signal transmission line forms an optical field instrumentation system together with an optical star coupler and a master station. FBK···3 FEATURES 1. Resistive to noise and lightning Optical signal ensures a reliable signal transmission, because it is not affected by external noise and inductive lightning. Use of a nonmetallic optical (fiber) cable prevents propagation of inductive lightning through the cable, so a signal transmission immune to lightning can be realized. 2. Reliability due to redundant configuration Host system can be duplicated by using two optical cable trunk lines (between an optical star coupler and host system). This enhances reliability of users’ systems. 3. Intrinsic safety type explosion-proof Each equipment with a built-in battery can be constructed so as to be an intrinsic safety type individually (intrinsic safety type barrier unnecessary). SPECIFICATIONS Functional specifications • Fluids measured: Liquid, gas or steam • Measuring range, operating pressure and maximum allowable over-pressure: Span [kPa abs] Operating pressure MiniMaxi[kPa abs] mum mum value value 0 to 16 0 to 130 0 to 500 0 to 3000 1.6 3.25 12.5 75 16 130 500 3000 Range limits [kPa abs] Lower range limit 0 0 0 0 Max. allowable overUpper pressure range [MPa abs] limit 16 130 500 3000 0.5 0.5 1.5 9 Type FBK 01 FBK 02 FBK 03 FBK 04 • Process temperature: –40 to +85°C EDS5-88 Date April 15, 2005 FBK···3 • Self-diagnosis: Displayed on indication unit (option) and transmitted to master station. Item Measuring range abnormal Detecting unit failure Amplifier abnormal Battery voltage Battery voltage low alarm Host system Indication unit Performance specifications Accuracy rating (Note) ±0.2% when measuring span is 1/10 or more of maximum span ± 0.1+ 0.01 Maximum span Measuring span % when measuring span is less than 1/10 of maximum span Note: Percent value with respect to measuring span (including linearity, hysteresis and repeatability in standard 23°C status) • Remote control function: See Table 1. • Output signal: Optical digital signal • Power supply: Built-in lithium battery (expected life about 4 years) • Optical cable: Code set type, silica fiber ... core/clad diameter 100/140 µm • Optical connector: FC connector • Transmission distance: 1.5 km max. (when transmission loss of optical cable is 4 dB/km) • Damping: Variable from 0.2 to 32 sec (time constant) • Zero elevation and suppression: Possible within a range from 0 kPa abs to maximum span. • Explosion-proof: Intrinsic safety type, JIS ib IIC T3 • Ambient temperature: –30 to +70°C –10 to +60°C for intrinsic safety explosion-proof type –20 to +70°C when provided with indicator • Storage temperature: –40 to +80°C • Ambient temperature effect: Zero shift: ± (0.125 + 0.2 × URL/x )%/ 28°C Overall shift: ± (0.175 + 0.2 × URL/x )%/ 28°C Where; URL: Maximum span x: Measuring span 2 times as large as above when the 7th digit (material) is other than V. • Maximum allowable pressure effect: Zero shift at maximum span ± 0.2% to maximum allowable pressure • Inclination effect: 0.1 kPa/10° • Measurement period: 0.2 sec • Response time: Time constant 0.2 sec (at 23°C) Dead time; About 0.2 sec Physical specifications Material: Material code V H M T Process cover SCS14 SCS14 SCS14 SCS14 Detecting unit Seal diaphragm Other wetted parts SUS316L Hastelloy-C Monel Tantalum SUS316 Hastelloy-C Monel Tantalum • Environmental protection: Meets JIS C0920, immersion-proof (equivalent to IEC IP67 or NEMA 6/6P) • Process connection: Rc1/4 or 1/4-18NPT (whichever selected by code symbol) Oval flange threads 7/16-20UNF • Optical cable connection: G1/2 or 1/2 -14NPT (whichever selected by code symbol) • Mounting method: Mounted on the 50A (2B) pipe with Ubolt • Finish: Epoxy-polyurethane double coat, Color: silver (blue for amplifier case cover) • External dimensions: See OUTLINE DIAGRAM. • Mass: 4.5 kg • Orientation of transmission unit: Indicator unit turnable 90° upward/downward relative to detection unit. 2 Optional specifications • Indication unit: 5-digit LCD indication, % or real scale indication (as specified by code symbol) Operating temperature range: –20 to +70°C • NACE specification: H2S-proof treatment in accordance with NACE specification Table 1 Remote Control Function (Items readable and setting from hand-held communicator) Item Maximum range Measuring range Damping Real scale indication Battery voltage Error indication Measured value Adjustment Reading Setting Description Maximum measuring range of equipment Actual measuring range Variable within 0.2 to 32 sec. Indication in industrial value Battery voltage of equipment Errors of detection unit and amplifier Measured data Zero and span adjustment Note: For operation of the “3” type transmitter (“3” at the 8th digit of product code), a hand-held communicator is required to have a version 1.6 or higher, but a communicator before version 1.6 can be operated with memory data updated. (Refer to the instruction manual of transmitter.) 3 FBK···3 SYSTEM BLOCK DIAGRAM Host system Master station Control room Field Star coupler Transmitter Field equipment (max. 8 units) Transmission distance: 1.5 km max. (between master station and field equipment) 1:1 system 1 to 5V DC 4 to 20mA DC Optical fiber type electric converter (Type; PSN) Control room Field Transmitter Transmission distance: 4 km max. 4 CODE SYMBOLS 12345678 F BK 0 3 9 10111213 F 1415 Description Process cover (4th digit) Process connection Cable lead-in port Rc1/4 G1/2 1/4-18NPT 1/2-14NPT Measuring span (6th digit) 1.6...........16 kPa abs 3.25.......130 kPa abs 12.5.......500 kPa abs 75........3000 kPa abs Material (7th digit) V H M T Process cover SCS14 SCS14 SCS14 SCS14 Seal diaphragm SUS316L Hastelloy-C Monel Tantalum Other wetted parts SUS316 Hastelloy-C Monel Tantalum Note) Note) Not available when 6th digit is “1”. S T 1 2 3 4 A L P Indicator (9th digit) Not provided Digital, % indication Digital, real scale indication Explosion-proof (10th digit) Non-explosion proof Intrinsic safety, JIS Side vent/drain and fixture (11th digit) A C D F Side vent/drain None None Yes Yes Fixture None Yes (stainless steel) None Yes (stainless steel) A G Treatment and Fill-fluid (13th digit) Y G N Treatment None Degreasing NACE specification Fill-fluid Silicon oil Silicon oil Silicon oil Note) Note) Unavailable when 7th digit is “T”. A C D E O-ring material (for process cover)(14th digit) Viton Bolt/nut (15th digit) NACE bolt/nut (ASTM A193 B7M/A194 2HM) NACE bolt/nut (ASTM A320 L7M/A194 2HM) SUS304/SUS304.... (For general use) 5 FBK···3 OUTLINE DIAGRAM P (Unit : mm) 241 80 108 70 FBK S 0 T V H M 3– T A C Mounting pipe JIS 50A (2B) U-bolt (M8) 315 225 8 70 φ102 54 15 B Optical cable lead-in port Indicator (option) Gas vent, drain port 37 27 47 Pressure connection 15 3 41.3 E 4–7/16-20UNF Thread depth 13 (for oval flange) D φ18.5 Details of “B” Details of “A” 27 View from arrow P D E Type FBKS Rc1/4 G1/2 FBKT 1/4–18NPT 1/2–14NPT 6 2.5 8 A φ15 φ7 SCOPE OF DELIVERY Instrument body and pipe fixture (as specified) ITEM TO BE PREPARED SEPARATELY Oval flange: To be used as a flange of connecting pipe port. For details, refer to the DATA SHEET of oval flange (EDS6-10). ORDERING INFORMATION 1. 2. 3. 4. Model type Measuring range Indication scale for real scale specification Others 7 FBK···3 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS5-88 价格&库存

很抱歉,暂时无法提供与“EDS5-88”相匹配的价格&库存,您可以联系我们找货

免费人工找货