0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS5-89

EDS5-89

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS5-89 - OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE - Fuji Electric

  • 数据手册
  • 价格&库存
EDS5-89 数据手册
FFI SYSTEM OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE DATA SHEET The Model FBM 3 Optical Pressure Transmitter Remote Seal Type measures pressures of various fluids accurately, converts them into optical digital signals and outputs them. This is an intelligent transmitter providing excellent performance and functions due to incorporation of electrostatic capacitance type silicon sensor and microprocessor. A fiber optic cable used for the signal transmission line forms an optical field instrumentation system together with an optical star coupler and a master station. FBM…3 FEATURES 1. Resistive to noise and lightning Optical signal ensures a reliable signal transmission, because it is not affected by external noise and inductive lightning. Use of a nonmetallic optical (fiber) cable prevents propagation of inductive lightning through the cable, so a signal transmission immune to lightning can be realized. 2. Reliability due to redundant configuration Host system can be duplicated by using two optical cable trunk lines (between an optical star coupler and host system). This enhances reliability of users’ systems. 3. Intrinsic safety type explosion-proof Each equipment with a built-in battery can be constructed so as to be an intrinsic safety type individually (intrinsic safety type barrier unnecessary). Process temperature, Allowable pressure limit: Fill-fluid Fluorolube oil Silicon oil Silicon oil Silicon oil Silicon oil Silicon oil Silicon oil 13th code digit Allowable Process temperature pressure limit W, A, D -20 to 120˚C Atmospheric pressure H -15 to 250˚C or higher J Y, G S T K  85 to 300˚C -40 to 120˚C 2.7 kPa abs or higher -15 to 250˚C See Fig. 1.  85 to 300˚C -15 to 200˚C 0.13 kPa abs or higher See Fig. 2. For small bores 40A, 50A, 1-1/2B, 2B: Fill-fluid 13th code digit Process Allowable temperature pressure limit SPECIFICATIONS Functional specifications Fluids measured: Liquid, gas or steam Measuring range: Span [kPa] Type Minimum value 3.25 12.5 75 250 1250 Maximum value 130 500 3000 10000 50000 Range limit [kPa] Lower range limit Determined by allowable operating pressure limit of particular fill fluid (See table at right.) Fluorolube oil Silicon oil Silicon oil Silicon oil W, A, D -20 to 120˚C Atmospheric pressure 0 to 250˚C or higher H Y, G S -40 to 120˚C 2.7 kPa abs or higher 0 to 250˚C See Fig. 1. Self-diagnosis: Displayed on indication unit (option) and transmitted to master station. Upper range limit 130 500 3000 10000 50000 Max. allowable overpressure [MPa] 1 1.5 4.5 15 75 Item Measuring range abnormal Detecting unit failure Amplifier abnormal Battery voltage Battery voltage low alarm Host system Indication unit ○ ○ ○ ○ ○ ○ ○ ○ − ○ FBM□□1 FBM□□2 FBM□□3 FBM□□4 FBM□□5 Operating pressure: Up to the maximum value of measuring range, provided the maximum operating pressure of flange should not be exceeded. Remote control function: See Table 1. Output signal: Optical digital signal Power supply: Built-in lithium battery (expected life about 4 years) Optical cable: Code set type, silica fiber ... core/clad diameter 100/140 µm Optical connector: FC connector EDS5-89 Date May 20, 2004 FBM···3 Transmission distance: 1.5 km max. (when transmission loss of optical cable is 4 dB/km) Damping: Variable from 0.2 to 32 sec (time constant) Zero elevation and suppression: Possible within a range from - 0.1 MPa to maximum span. Explosion-proof: Intrinsic safety type, JIS ib IIC T3 Ambient temperature: –30 to +70°C –10 to +60°C for intrinsic safety explosion-proof type –20 to +70°C when provided with indicator –10 to +60°C when filled with fluorolube oil –10 to +70°C for silicone oil codes H, S and K +20 to +70°C for silicone oil codes J and T For small bores 40A, 50A, 1-1/2B, 2B: –15 to +65°C –10 to +60°C for intrinsic safety explosion-proof type –15 to +65°C when provided with indicator –10 to +60°C when filled with fluorolube oil –10 to +60°C for silicone oil codes H and S. Storage temperature: –40 to +80°C Ambient temperature effect: For small bores 40A, 50A, 1-1/2B, 2B: Zero shift: ± 0.7% / 28°C (x equal to 1/2 URL or more) URL Zero shift: ± 0.7 % / 28°C (x less 2x than 1/2 URL) Overall shift: ± 0.9% / 28°C (x equal to 1/2 URL or more) URL Overall shift: ± (0.4 + 0.5 2x )% / 28°C (x less than 1/2 URL) Note 1: Condition; Capillary length is limited to max. 3 m. With a capillary of 5 m long, the effect is 1.5 times as large as the above. Note 2: The effect is 2.5 times as large as the above when the 7th code digit (material) is other than V, A, B, C and D. Maximum allowable pressure effect: Zero shift at maximum span ± 0.2% / nominal pressure of flange For small bores 40A, 50A, 1-1/2B, 2B: ± 0.2% / (1.5 x URL) URL: Maximum span Measurement period: 0.2 sec Response time: Time constant 0.3 sec (Value at capillary length 1.5 m and 23°C) Dead time: About 0.2 sec Physical specifications Performance specifications Accuracy rating (Note) ±0.2% when measuring span is 1/10 or more of maximum span max. span ±(0.1 + 0.01 )% when measuring span measuring span is less than 1/10 of maximum span. Flange material: SUS304 Screw-in design for 10 and 50 MPa specifications (thread material: carbon steel) Material: Material code V, A, B, C, D H, F, G, K, L M T P R Seal diaphragm SUS316L Hastelloy-C Monel Tantalum Titanium Zirconium Other wetted parts SUS316 Hastelloy-C Monel Tantalum Titanium Zirconium Note: Percent value with respect to measuring span (including linearity, hysteresis and repeatability in standard 23°C status) For small bores 40A, 50A, 1-1/2B, 2B: Accuracy rating (Note) ±0.25% when measuring span is 1/10 or more of maximum span max. span ±(0.17 + 0.008 measuring span )% when measuring span is less than 1/10 of maximum span. Note 1: Selected according to combination of type codes. Refer to CODE SYMBOLS. Capillary: Finish: Ambient temperature effect: Zero shift: ± (0.5 URL x )% / 28°C URL Overall shift: ± (0.7 x )% / 28°C Where; URL: Maximum span x: Measuring span 2 times as large as above when the 7th digit (material) is other than V, A, B, C and D. Remarks: (1) This is an output change when the process pressure receiving unit and the transmitter body are at the same height and temperature. (2) Error is larger when there is a temperature difference among the process pressure receiving unit, capillary and transmitter body. Stainless steel pipe coated with PVC Epoxy-polyurethane double coat, Color: silver (blue for amplifier case cover) Environmental protection: Meets JIS C0920, immersion-proof (equivalent to IEC IP67 or NEMA 6/6P) External dimensions: See OUTLINE DIAGRAM. Mass: 10.5 to 13.5 kg Optical cable connection: G1/2 or 1/2 -14NPT (whichever selected by code symbol) Process connection: JIS specifications; 10K, 20K, 30K, 63K-40, 50A 10K-80A, 100A ANSI/JPI specifications; 150LB, 300LB, 600LB, 1-1/2B, 2B 150LB-3B, 4B 2 Operating pressure Diaphragm extension: 0, 50, 100, 150 or 200 mm (as specified) Mounting method: U-bolt mounting to a 50A (2B) pipe. Detection unit is mounted with flange or between flanges (wafer type). Orientation of transmission unit: Indicator unit turnable 90° upward/downward relative to detection unit. Capillary length: Max. 10 m Max. 5 m for small bore 40A, 50A, 1-1/2B or 2B Fill-fluid: Silicon oil (Code: Y,G) [kPa abs] Fill-fluid: Silicon oil (Code: S) Fill-fluid: Silicon oil (Code: T) With small bore 101 53.3 Operating area 13.3 Optional specifications Indication unit: 5-digit LCD indication, % or real scale indication (as specified by code symbol) Operating temperature range: – 20 to +70°C Oxygen oil-proof processing:  Varies with  Fluorolube filled. material. Wetted parts degreased  Refer to  and cleaned.  CODE  Chlorine service: Fluorolube oil filled.  SYMBOLS. 2.7 Non-operating area -40 -15 0 60 85 120 200 230250 Process temperature 300 [°C] Note: For use at a vacuum level, the transmitter body should be mounted below the flange section mounting position. Fig. 1 Relation between process temperature and operating pressure [kPa abs] Fill-fluid: Silicon oil (Code: K) Item Maximum range Measuring range Damping Real scale indication Battery voltage Error indication Measured value Adjustment Reading Setting Description Maximum measuring range of equipment Actual measuring range Variable within 0.2 to 32 sec. Indication in industrial value Battery voltage of equipment Errors of detection unit and amplifier Measured data Zero and span adjustment Operating pressure Table 1 Remote Control Function (Items readable and setting from hand-held communicator) 101 Operating area Nonoperating area 0.27 0.13 -15 100 Process temperature 200 [°C] Note: For operation of the “3” type transmitter (“3” at the 8th digit of product code), a hand-held communicator is required to have a version 1.6 or higher, but a communicator before version 1.6 can be operated with memory data updated. (Refer to the instruction manual of transmitter.) Fig. 2 Relation between process temperature and operating pressure SYSTEM BLOCK DIAGRAM Host system Master station Control room 1:1 system 1 to 5V DC 4 to 20mA DC Optical fiber type electric converter (Type; PSN) Field Star coupler Transmitter Field equipment (max. 8 units) Transmission distance: 1.5 km max. (between master station and field equipment) Transmitter Transmission distance: 4 km max. 3 FBM···3 CODE SYMBOLS 12345678 F BM 3 S T 9 10111213 F Cable lead-in port (4th digit) G1/2 1/2-14NPT Flange (5th digit) Material 0 1 3 4 A B C D E F G H J L M N V W P Q R S K Rating Code usable at 6th digit JIS 10K 80A 1,2,3 JIS 10K 100A 1,2,3 ANSI/JPI 150LB 3B 1,2,3 ANSI/JPI 150LB 4B 1,2,3 JIS 10K 40A 3 JIS 10K 50A 3 JIS 20K 40A 3 JIS 20K 50A 3 JIS 30K 40A 3,4 JIS 30K 50A 3,4 JIS 63K 40A 3,4 JIS 63K 50A 3,4 ANSI/JPI 150LB 11/2B 3 ANSI/JPI 150LB 2B 3 ANSI/JPI 300LB 11/2B 3 ANSI/JPI 300LB 2B 3 ANSI/JPI 600LB 11/2B 3,4 ANSI/JPI 600LB 2B 3,4 For JIS 80A, ANSI/JPI 3B 1,2,3 For JIS100A, ANSI/JPI 4B 1,2,3 For JIS 50A, ANSI/JPI 2B 3,4 For JIS 40A, ANSI/JPI 11/2B 3,4 JIS G1 thread 4,5 Code usable at 7th digit All codes usable P and R unusable All codes usable P and R unusable V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T V,H,M,T V,A to D,H,M,T All codes usable P and R unusable V,A to D,H,M,T V,H,M,T V Description SUS304 Wafer type (without flange) Screw-in type 1 2 3 4 5 Measuring span (6th digit) 3.25.........130kPa 12.5...... 500kPa 75........ 3000kPa …Selectable when 7th digit is V, A, B, C, D, H, M or T. 250...... 10000kPa Must be specified for 5th code K. 1250.... 50000kPa 7th digit must be V. Material and diaphragm extension (7th digit) V A B C D H F G K L M T P R A L P A G Seal diaphragm SUS316L SUS316L SUS316L SUS316L SUS316L Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C Monel Tantalum Titanium Zirconium Other wetted parts SUS316 SUS316 SUS316 SUS316 SUS316 Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C Monel Tantalum Titanium Zirconium Diaphragm extension (mm) 0 Only 5th codes 1, 4 and Q are 50 selectable when these codes 100 are used in combination 150 with 13th codes S, T or K. 200 0 50 100 150 200 0 0 Selectable when 6th digit is 0 2 and 5th digit is 0, 3 or P. 0 Indicator (9th digit) Not provided Digital, % indication Digital, real scale indication Explosion-proof (10th digit) Non-explosion proof Intrinsic safety, JIS 4 12345678 F BM 3 9 10111213 F A B C G H J K Description Capillary length (11th digit) 1.5m 3m 5m 6m.....Selectable when 5th digit is 0, 1, 3, 4, P or Q. 7m Selectable when 5th digit is 0, 1, 3, 4, P or Q 8m and 13th digit is Y, W, G, A or D. 10m Treatment and fill-fluid (13th digit) Treatment Fill-fluid None Silicon oil None Fluorolube oil Degreasing Silicon oil Oxygen oil-proof processing Fluorolube oil..... when 7th digit is V, A, B, C or D Chlorine service Fluorolube oil..... when 7th digit is H, F, G, K, L or T when 6th digit is 1, 2, 3, and None Silicon oil (for high temperature) 7th digit is V, A, B, C or D None Silicon oil (for high temperature) when 6th digit is 2, None Silicon oil (for high temperature and vacuum) and 7th digit is V, A, None Silicon oil (for high temperature and vacuum) B, C or D None Silicon oil (for high temperature and high vacuum) Y W G A D H Note 1 J S Note 1 T Note 1 K Note 1: Inapplicable for small bores 40A, 50A, 1-1/2B and 2B. 5 FBM···3 OUTLINE DIAGRAM 0CJ 1DL 3 EM 4 FN AGV B HW 1 2 3 4 (Unit : mm) FBM 3 φF S: Capillary length S t 241 80 108 70 φK φJ φH Inside diameter of gasket seat U-bolt (M8) Mounting pipe JIS 50A (2B) L 20 315 225 8 70 φ102 54 15 N-φh hole φG 37 27 47 B Optical cable lead-in port Indicator (option) φ15 Type E G1/2 1/2-14NPT Type FBM*0**3 FBM*1**3 FBM*3**3 FBM*4**3 FBM*A**3 FBM*B**3 FBM*C**3 FBM*D**3 FBM*E**3 FBM*F**3 FBM*G**3 FBM*H**3 FBM*J**3 FBM*L**3 FBM*M**3 FBM*N**3 FBM*V**3 FBM*W**3 φF 185 210 191 229 140 155 140 155 160 165 175 185 127 152 156 165 156 165 φG 150 175 152.5 190.5 105 120 105 120 120 130 130 145 98.4 120.6 114.3 127 114.3 127 φH 126 151 126 151 84 84 84 84 84 84 84 84 84 84 84 84 84 84 φJ 100 103 100 103 49 49 49 49 49 49 49 49 49 49 49 49 49 49 φK 73 96 73 96 48 48 48 48 48 48 48 48 48 48 48 48 48 48 t 38 38 44 44 36 36 38 38 42 42 52 54 37.5 39.5 41 42.5 42.5 45.5 P 116 141 116 141 71 71 71 71 71 71 71 71 71 71 71 71 71 71 N-φh 8-19 8-19 4-20 8-20 4-19 4-19 4-19 8-19 4-23 8-19 4-25 8-23 4-16 4-20 4-23 8-20 4-23 8-20 FLANGE JIS-10K-80A JIS-10K-100A ANSI/JPI 150lB 3B ANSI/JPI 150lB 4B JIS-10K-40A JIS-10K-50A JIS-20K-40A JIS-20K-50A JIS-30K-40A JIS-30K-50A JIS-63K-40A JIS-63K-50A ANSI/JPI 150LB 11/2B ANSI/JPI 150LB 2B ANSI/JPI 300LB 11/2B ANSI/JPI 300LB 2B ANSI/JPI 600LB 11/2B ANSI/JPI 600LB 2B 3 FBMS FBMT E Details of "B" 15 Type FBM***V3 FBM***H3 FBM***M3 FBM***T3 FBM***P3 FBM***R3 FBM***A3 FBM***F3 FBM***B3 FBM***G3 FBM***C3 FBM***K3 FBM***D3 FBM***L3 L 0 Mass (kg) 10.5 50 100 150 200 11.5 12.5 13 13.5 Note) For S (capillary length), refer to CODE SYMBOLS. 6 P 131 FBM P Q R S 1 2 3 4 3 315 20 Type FBM*P**3 FBM*Q**3 FBM*R**3 FBM*S**3 φH φJ P FLANGE φ102 54 37 27 47 126 100 116 80A, 3B φH φJ 151 103 141 100A, 4B 84 84 49 49 71 50A, 2B 71 50A, 11/2B P 2-M6, depth 9 for flange mounting FBM K 4 V3 5 S 241 80 108 70 U-bolt (M8) 315 Mounting pipe JIS 50A (2B) 225 8 70 φ102 B Optical cable lead-in port φ15 Indicator (option) -0.1 15 φ30 -0.2 -0.1 φ23.6 -0.2 54 Packing G1 37 27 47 2 Type FBMS FBMT E G1/2 1/2-14NPT 2 18 53 3 45 100 20 E 15 Note) For S, refer to CODE SYMBOLS. Details of "B" 131 7 FBM···3 SCOPE OF DELIVERY Instrument body and pipe fixture (as specified) ORDERING INFORMATION 1. 2. 3. 4. Model type Measuring range Indication scale for real scale specification Others Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS5-89 价格&库存

很抱歉,暂时无法提供与“EDS5-89”相匹配的价格&库存,您可以联系我们找货

免费人工找货