FFI SYSTEM
OPTICAL DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER
DATA SHEET
The Model FFK 3 Optical Differential Pressure (Flow) Transmitter measures differential pressures (flow rates) of various fluids accurately, converts them into optical digital signals and outputs them. This is an intelligent transmitter providing excellent performance and functions due to incorporation of electrostatic capacitance type silicon sensor and microprocessor. A fiber optical cable used for the signal transmission line forms an optical field instrumentation system together with an optical star coupler and a master station.
FFK···3
FEATURES
1. Resistive to noise and lightning Optical signal ensures a reliable signal transmission, because it is not be affected by external noise and inductive lightning. Use of a nonmetallic optical (fiber) cable prevents propagation of inductive lightning through the cable, so a signal transmission immune to lightning can be realized. 2. Reliability due to redundant configuration Host system can be duplicated by using two optical cable trunk lines (between an optical star coupler and host system. This enhances reliability of users’ systems. 3. Intrinsic safety type explosion-proof Each equipment with a built-in battery can be constructed so as to be an intrinsic safety type individually (intrinsic safety type barrier unnecessary).
SPECIFICATIONS
Functional specifications
Fluids measured: Liquid, gas or steam Measuring range and operating pressure:
Type Operating pressure [MPa] Span [kPa] Range limits [kPa] Minimum Maximum Lower Upper value value range limit range limit
FFKM11 -0.1 to +3.2 FFKM22 -0.1 to +10 FFKM23 -0.1 to +10 FFKM25 -0.1 to +10 FFKM26 -0.1 to +10 FFKM33 -0.1 to +16 FFKM35 -0.1 to +16 FFKM36 -0.1 to +16 FFKM38 -0.1 to +16 FFKM43 -0.1 to +42 FFKM45 -0.1 to +42 FFKM46 -0.1 to +42 FFKM48 -0.1 to +30
0.1 0.15 0.8 3.25 12.5 0.8 3.25 12.5 75 0.8 3.25 12.5 75
1 6 32 130 500 32 130 500 3000 32 130 500 3000
-1 -6 -32 -130 -500 -32 -130 -500 -3000 -32 -130 -500 -3000
1 6 32 130 500 32 130 500 3000 32 130 500 3000
EDS6-125
Date May 20, 2004
FFK···3
Process temperature, Allowable pressure limit: For details refer to Fig.1.
Fill-fluid Silicon oil Fluorolube oil Silicon oil 13th Process (Note) Allowable pressure limit code digit temperature Y, G, N -40 to +120°C 2.7kPa abs Atmospheric pressure 2.7kPa abs
Max. span
(Note)
Performance specifications
For linear output of differential pressure
Medium High differential differential pressure pressure 1, 6kPa 32, 130kPa 500, 3000kPa ±0.1% when measuring span is 1/10 or more of maximum span. max. span ±(0.05 + 0.005 )% when measuring span measuring span is less than 1/10 of maximum span. Low differential pressure Zero shift: URL ±(0.125+0.2 x )% / 28°C Overall shift: URL ±(0.175+0.2 x )% / 28°C Twice as large as above when 7th digit (material) is other than V ±0.3% / 1MPa
W, A, D -20 to +80°C R -15 to +120°C
Self-diagnosis:
Displayed on indication unit (option) and transmitted to master station.
Diagnosis item Host system Indication unit
Accuracy rating
Measuring range abnormal Detecting unit failure Amplifier abnormal Battery voltage Battery voltage low alarm
Remote control function: See Table 1. Output signal: Optical digital signal Power supply: Built-in lithium battery (expected life: about 4 years) Optical cable: Code set type, silica fiber ... core/clad diameter 100/140 µ m Optical connector: FC connector Transmission distance: 1.5 km max. (when transmission loss of optical cable is 4 dB/km) Damping: Variable from 0.2 to 32 sec (time constant) Zero elevation and suppression: Possible within ± 100% of maximum span. Explosion-proof: Intrinsic safety type, JIS ib IIC T3 Ambient temperature: - 30 to +70°C - 10 to +60°C for intrinsic safety explosion-proof type - 20 to +70°C when provided with indicator - 10 to +60°C when filled with fluorolube oil Storage temperature: - 40 to +80°C
Zero shift: URL ±(0.1+0.05 x )% / 28°C Overall shift: URL ±(0.15+0.05 x )% URL: Max. span / 28°C x: 3 times as large as above when Measuring 7th code (material) is other than span V Overrange ±0.1% / 10MPa effect ±0.1% / 16MPa (zero shift at ±0.1% / 3.2MPa ±0.25% / 42MPa max. span) Twice as large as above when 7th digit (material) is other than V Static pressure ±0.2% / 1MPa ±0.05% / 10MPa effect ±0.1% / 3.2MPa (zero shift at Twice as large as above when 7th digit (material) is max. span) other than V (Span shift +0.2 +0.2 at measuring -0.2%-0.4 % / 3.2MPa -0.2% -0.4 % / 10MPa span) Note: Percent value with respect to measuring span (including linearity, hysteresis and repeatability in standard 23°C status)
Abmient temperature effect
For square-root output
Low Medium High differential pressure differential pressure differential pressure 1, 6kPa 32, 130kPa 500, 3000kPa (Between 1 and 0.1) × max. span: ±0.1% for output 50 to 100% ±0.25% for output 20 to less than 50% ±0.5% for output 10 to less than 20% (Between 0.1 and 0.04) × max. span: For output 50 to 100%; max. span ±1 × (0.05 + 0.005 )% measuring span For output 20 to less than 50%; max. span ±2.5 × (0.05 + 0.005 )% measuring span For output 10 to less than 20%; max. span ±5 × (0.05 + 0.005 )% measuring span
Max. span Accuracy rating (inclusive of linearity and hysteresis)
Low flow cutoff point
Flow rate value variable within 0 to 20% (default value: 7%) ±2.5 × (0.1 + 0.2 Ambient URL ±2.5 × (0.1 + 0.05 x )% / 28°C URL temperature × x )% / 28°C effect (shift at 20% point) URL: Max. span x: Measuring span
2
Inclination effect: 0.12kPa/ 10° Double above value when 13th digit (treatment, sealed liquid) is W, D, or A. Measurement period: 0.2 sec Response time:
Type *Time constant [sec] Dead time [sec] 0.8 0.5 0.3 0.2 FFKM11 FFKM22 FFKMM3 5 FFKMM 8 Note: *Value at 23°C
Optional specifications
Indication unit: 5-digit LCD indication, % or real scale indication (as specified by code symbol) Operating temperature range: - 20 to +70°C Oxygen oil-proof processing: Fluorolube oil filled, wet- ted parts degreased and Varies with cleaned. material. Chlorine service: Fluorolube oil filled Refer to NACE specification: CODE H2S-proof treatment in SYMBOLS. accordance with NACE specifications.
About 0.2
Physical specifications
Material:
Material code V J Process cover
For details, refer to Code symbols.
Detecting unit
Operating pressure [MPa] Seal diaphragm Other wetted parts 3.2 10 16 42 SCS14 SUS316L SUS316 SCS14 SUS316L · Gold- SUS316 plated H SCS14 Hastelloy-C Hastelloy-C M SCS14 Monel Monel T SCS14 Tantalum Tantalum B Hastelloy-C Hastelloy-C Hastelloy-C lining L Monel lining Monel Monel U Tantalum Tantalum Tantalum lining Notes: ...available, ...unavailable
Environmental protection: Meets JIS C0920 immersion-proof (equivalent to IEC IP67 or NEMA 6/6P). Process connection: Rc1/4 or 1/4-18NPT (whichever selected by code symbol) Oval flange thread 7/16-20UNF Optical cable connection: G1/2 or 1/2-14NPT (whichever selected by code symbol) Mounting method: Mounted on 50A (2B) pipe with U-bolt or on a wall. Finish: Epoxy-polyurethane double coat, Color; Silver (blue for case cover). External dimensions: See OUTLINE DIAGRAM. Mass: 5.3 to 5.5kg Orientation of transmission unit: Indicator unit turnable 90° upward/downward relative to detection unit.
3
FFK···3
Table 1 Remote Control Function (Items readable and setting from hand-held communicator)
Item Maximum range Measuring range Damping Real scale indication Battery voltage Error indication Measured value Adjustment Reading Setting Description Maximum measuring range of equipment Actual measuring range Variable within 0.2 to 32 sec Indication in industrial value Battery voltage of equipment Errors of detection unit and amplifier Measured data Zero and span adjustment
[kPa abs] 101
Operating pressure
Fill-fluid: Silicone oil (Code: Y, G, N) Fill-fluid: Silicone oil (Code: R)
Operating area 20
Note: For operation of the “3” type transmitter (“3” at the 8th digit of product code), a hand-held communicator is required to have a version 1.6 or higher, but a communicator before version 1.6 can be operated with memory data updated. (Refer to the instruction manual of transmitter.)
4 2.7 None-operating area –40 –15 60 85 120 [°C]
Process temperature
Fig. 1 Relation between process temperature and operating pressure
SYSTEM BLOCK DIAGRAM
Host system Master station Control room 1:1 system 1 to 5V DC 4 to 20mA DC Optical fiber type electric converter (Type; PSN)
Field
Star coupler
Transmitter Field equipment (max. 8 units) Transmission distance: 1.5 km max. (between master station and field equipment)
Transmitter
Transmission distance: 4 km max.
4
CODE SYMBOLS
12345678 FFK 3 9 10111213 1415 F Description Connection (4th digit) Process connection Cable lead-in port Rc1/4 G1/2 1/4-18NPT 1/2-14NPT Operating pressure and measuring span (5th and 6th digits) Operating pressure range Measuring span -0.1 to +3.2 MPa 0.1………...1 kPa -0.1 to +10 MPa 0.15……… 6 kPa -0.1 to +16 MPa 0.8……… 32kPa 3.25…… 130kPa 12.5…… 500kPa 75…… 3000kPa -0.1 to +42 MPa 0.8……… 32kPa 3.25…… 130kPa 12.5…… 500kPa -0.1 to +30 MPa 75…… 3000kPa -0.1 to +10 MPa 0.8……… 32kPa For material codes B, L 3.25…… 130kPa and U 12.5…… 500kPa Material (7th digit) Process cover V J H M T B L U SCS14 SCS14 SCS14 SCS14 SCS14 Hastelloy-C lining Monel lining Tantalum lining Other Application wetted parts (5th and 6th digits) SUS316 11,22,33,35,36,38, 43,45,46,48 SUS316L · Gold- SUS316 11,22,33,35,36,38, plated 43,45,46,48 Hastelloy-C Hastelloy-C 11,22,33,35,36,43, 45,46 Monel Monel 33,35,36,43,45,46 Tantalum Tantalum 33,35,36 Hastelloy-C Hastelloy-C 23,25,26 Monel Monel Tantalum Tantalum Seal diaphragm SUS316L
S T
11 22 33 35 36 38 43 45 46 48 23 25 26
Y A L P Q S
Indicator and output (9th digit) Indicator Output Not provided Linear Not provided Square-root extraction Digital, % indication Linear Digital, real scale Linear Digital, % indication Square-root extraction Digital, real scale Square-root extraction Explosion-proof (10th digit) Non-explosion proof Intrinsic safety, JIS
A G
5
FFK···3
12345678 FFK 3
9 10111213 1415 F
Description Side vent/drain and fixture (11th digit) Side vent/drain None None Yes Yes Mounting fixture None Yes (stainless steel) Cannot be specified None when 7th digit is B, L Yes (stainless steel) or U.
A C D F
Treatment and Fill-fluid (13th digit) Y W G A D N R Treatment None None Degreasing Oxygen oil-proof processing Chlorine service NACE specification None Fill-fluid Silicon oil Fluorolube oil Silicon oil Fluorolube oil ... Specifiable when 7th digit is V. Fluorolube oil ... Cannot be specified when 7th digit is V, M or L. Fluorolube oil ... Cannot be specified when 7th digit is T or U. Silicon oil (for vacuum)
A B
O-ring material (for process cover)(14th digit) Viton Teflon Bolt/nut (15th digit) NACE bolt/nut (ASTM A193 B7M/A194 2HM) Note 1 NACE bolt/nut (ASTM A320 L7M/A194 2HM) SUS304/SUS304 ... (For general use) ... Note 2 SUS630/SUS304 ... Specify when 5th digit is 3 or 4. Note 1: Operating pressure is limited within 10 MPa. Note 2: Specifiable when 5th digit is 1, 2 or 3. However, operating pressure is limited within 10 MPa.
C D E F
6
OUTLINE DIAGRAM
P
(Unit : mm)
V J H 3– M T
241 80 108 70
FFK S T
A C
Mounting pipe JIS 50A (2B)
U-bolt (M8)
315
225 8
70
φ102
54 15
B
Optical cable lead-in port
Indicator (option) Gas vent, drain port 37 27 47
A
Low pressure connection
41.3
A
High pressure connection LH
FFK S T
B L 3– U A
A C
4–7/16-20UNF Thread depth 13 (for oval flange) 27
φ102
Pressure connection 318 41.3
φ15
3 15
φ7
8
54 D φ18.5
2.5
E
4-7/16-20UNF Thread depth 10 (for oval flange) 40 Gas vent, drain port 27 47 φ16 φ12
+0.2 +0.1
Details of “B” Details of “A”
Type D E
FFKS Rc1/4 G1/2
FFKT φ4
2 –0.1
0
1/4–18NPT 1/2–14NPT
1
Details of “A”
28
View from arrow P
7
FFK···3
SCOPE OF DELIVERY
Instrument body and pipe fixture (as specified)
ORDERING INFORMATION
1. 2. 3. 4. Model type Measuring range Indication scale for real scale specification Others
ITEM TO BE PREPARED SEPARATELY
Oval flange: To be used as a flange of connecting pipe port. For details, refer to the DATA SHEET of oval flange (EDS6-10). Refer to DATA SHEET (EDS6-10).
Equalizing valve:
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.