    EDS6-132F - HYBRID ULTRASONIC FLOWMETER (Pulse Doppler method Transit Time method) - Fuji Electric

  • 数据手册
  • 价格&库存
EDS6-132F 数据手册
HYBRID ULTRASONIC FLOWMETER (Pulse Doppler method + Transit Time method) DATA SHEET This meter is the world’s first non-intrusive type ultrasonic flowmeter utilizing Pulse Doppler method along with Transit Time method. It enables measurement of velocity profile directly resulting in high accuracy. This makes it suitable for undeveloped flow and for short straight pipes. Pulse Doppler method requires reflectors in the liquid and is utilized on opaque liquids while Transit Time method requires ultrasound penetration and is ideal for clean liquids. The new hybrid technology utilizes both methods in a complementary fashion thus enabling a wider range of applications than it is possible now. In addition, thanks to Fuji’s new state-of-the-art algorithm, either method can be automatically switched to accommodate for varying fluid conditions such as concentration of particles and/or air bubbles and flow velocity. FSH, FSW, FLY Flow transmitter (FSH) 1. Automatic switchover function between Pulse Doppler method utilizing ultrasound reflection and Transit Time method utilizing ultrasound penetration • Applicable to various kinds of liquids with/without air bubbles and/or solid particles • Applicable to liquid flow that changes in nature frequently or periodically 2. High-accuracy non-intrusive (non-contact) volumetric flow rate measurement of liquid flow in closed pipes. • Accuracy of 0.5% to 1% (depending on the measuring mode and pipe size) • Clamp-on sensor 3. Direct measurement of velocity profile in case of Pulse Doppler method • High accuracy of 0.5% to 1.5% (correction coefficient unnecessar y) • Applicable to undeveloped flow (short straight pipe) • Applicable to flow hovering in the transitional region between laminar flow and turbulent flow 4. High speed response: 0.2sec (pulse Doppler method)/ 0.5sec (transit time method) 5. Real time monitoring of velocity profile by PC in case of Pulse Doppler method (option) 6. Dual-path option improves performance FEATURES Detector (FSW) SPECIFICATIONS Operational specifications System configuration: The system is composed of one/two detectors (Model: FSW) and one Flow transmitter (Model: FSH), realizing single-path/two-path measurement. Hybrid mode or transit time mode is selectable. In case of hybrid mode, ether Pulse Doppler method or transit time method is automatically s elected d epending o n c onditions o f measured liquid and magnitude of velocity. Application: Uniform liquid in which ultrasonic waves can propagate. Air bubble quantity: Pulse Doppler method: 0.02 to 15% of volume at 1 m/s Transit time method: 0 to 12% of volume at 1 m/s Fluid temperature: -40 to +100ºC (FSW12), -40 to 80ºC (FSW21, FSW40,FSW50) Type of flow: Pulse D oppler m ethod: a xisymmetric flow in a filled pipe. Transit t ime m ethod: w elldeveloped turbulent or laminar flow in a filled pipe. Applicable flow pipe: Material: Plastics ( PVC, F RP, e tc.) o r Metals (carbon steel, SS, copper, aluminum, etc.) Pipe size: 40 to 1000 mm (inside diameter) Liner: Tar epoxy, mortar, etc. Straight pipe length: Typically 10D for upstream and 5D for downstream. Refer to JEMIS-032 in detail. (Note) J EMIS: Japan E lectric Measuring Instruments Manufactures' Associations Standard Velocity: Hybrid mode: 0 to ±0.3 --- ±Maximum Velocity (depending on pipe diameter) (Note) Maximum m easurement r ange i n H ybrid m ode (see page 4) Transit time mode: 0 to ±0.3 --- ±32 m/s Power supply: 100 to 240 Vac+10%/-15%, 50/60Hz or 20 to 30 Vdc Date EDS6-132f Apr. 1, 2011 FSH, FSW, FLY Signal cable: Single-path system : A p air o f R F c o-axial c ables for u ltrasound signals and a three-core shield cable for temperature sensor, Two-path s ystem: Two p airs o f R F c o-axial cables for ultrasound signals and a three-core shield cable for temperature sensor, Maximum cable length: 150m Temperature range: 80ºC Environment: Non-explosive e nvironment w ithout d irect sunlight, corrosive gas and heat radiation Ambient temperature: -10 to +50ºC for flow transmitter, -20 to +80ºC for detector Ambient humidity: 95%RH or less for flow transmitter, 100%RH or less for detector Grounding: Class D (less than 100 ohm) Arrester: Surge absorbers for outputs and power supply incorporated as standard Digital output: +total, -total, alarm, acting range, flow switch or total switch -- arbitrarily selectable Mechanical relay contact: 1 point with socket (replaceable) Normally closed/open selectable Capacity:240 Vac/30 Vdc, 1 A Total pulse: less than 1 p/s (Pulse width: 50, 100 or 200 ms selectable) Transistor open collector: 2 points Capacity: 30 Vdc, 0.1 A Normally off/on selectable Total pulse: less than 1000 p/s (Pulse width: 0.5, 1, 2, 5, 10, 20, 50, 100 or 200 ms selectable) Communication interface: RS-232C equivalent / RS-485 (selectable) Number of connectable units: one (RS-232C)/ up to 31 (RS-485) Baud rate: 9600/19200/38400 bps selectable Parity: none/odd/even selectable Stop bit: 1 or 2 bits selectable Distance: up to 15 m (RS-232C)/up to 1k m (RS-485) Data: velocity, flow rate, +total, -total, status (standard), velocity profile (option) Display device: Graphic LCD (number of pixels: 240x64) with back light, Display language: Japanese, English, French, German or Spanish selectable Velocity/Flow rate display: Display of velocity and/or flow rate with flow direction D ata: u p t o 10 d igits ( decimal p oint t o b e counted as 1 digit) Unit: Metric/English system selectable Velocity Flow rate Metric system m/s L/s, L/min, L/h, L/d, kL/h, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s, BBL/min, BBL/h, kBBL/d, MBBL/d English system ft/s ft3/s, ft3/min, ft3/h, Mft3/d, gal/s, gal/min, gal/h, Mgal/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d Performance specifications Accuracy : Pulse Doppler method : Pipe size (inside diameter) and detector φ40mm to φ50mm or less (Detector: FSWS12) Velocity 1.5 m/s to Max. Velocity (Note) 0 m/s to 1.5 m/s φ50mm to φ200mm (Detector: FSWS12) 1.5 m/s to Max. Velocity (Note) 0 m/s to 1.5 m/s 1 m/s to φ100mm to φ1000mm (Detector: FSWS21,40,50) Max. Velocity (Note) 0 m/s to 1 m/s Accuracy ±1.0% of rate ±0.015m/s ±0.5% of rate ±0.0075m/s ±1.0% of rate ±0.01m/s (Note) Maximum velocity is depend on a pipe diameter. See Maximum measurement range in Hybrid mode (page 4). Transit time method : Pipe size (inside diameter) φ40mm to φ50mm or less Velocity 2 m/s to 32 m/s 0 m/s to 2 m/s φ50mm to φ300mm or less 2 m/s to 32 m/s 0 m/s to 2 m/s φ300mm to φ1000mm 1 m/s to 32 m/s 0 m/s to 1 m/s Accuracy ±1.5% of rate ±0.03m/s ±1.0% of rate ±0.02m/s ±1.0% of rate ±0.01m/s Note: ˝gal˝ means US gal. Total display: Display of forward or reverse total Data: up t o 10 d igits ( decimal p oint t o b e counted as 1 digit) Unit: Metric/English system selectable Total Metric system mL, L, m3, km3, Mm3, mBBL, BBL, kBBL English system ft3, kft3, Mft3, gal, kgal, mBBL, BBL, kBBL, ACRf Response time: Pulse Doppler method: 0.2sec (depending on pipe diameter and measuring condition) Transit time method: 0.5sec Power consumption: 20W or less Short-term thermal stability: 140ºC, 30 min (FSWS12), 100ºC, 30 min (FSWS21, FSWS40, FSWS50) Functional specifications Analog output: 4 to 20 mAdc (1 point) Max. load resistance: 1k ohm Configuration: Fully c onfigurable o n k eyboard b y m enudriven software Zero adjustment: Set zero/Clear available. (transit time method) Damping: 0 to 100s (every 0.1s) configurable for analog output and display Low flow cut off: 0 to 5 m/s configurable 2 Alarm: Hardware fault/process fault can be tied to digital output Burnout: Analog output: Hold/Upper limit/Lower limit/ Zero/Not-used selectable Total: Hold/Count selectable Timer: 0 to 900s (every 1s) configurable Bi-directional range: Forward and reverse ranges configurable independently Hysteresis: 0 to 20% of working range configurable Working range applicable to digital output Auto-2 ranges: Forward 2 ranges configurable independently Hysteresis: 0 to 20% of working range configurable Working range applicable to digital output Flow switch: Lower and upper switching points configurable independently Acting point applicable to digital output Total switch: +total switching point configurable Acting point applicable to digital output Acoustic coupler: Silicon compound (RTV) Material: Flow Transmitter: aluminum alloy Detector: PBT for housing, aluminum alloy for frame and SS for fastening belt Sensor cable(FLY6): RF coaxial cable (double shielded) External sheath: Black flame-resistant vinyl External diameter: About 7 mm .3 Terminal treatment: Water-resistant BNC connector (detector side), M3.5 amplifier terminal (Flow Transmitter side) Weight: About 90 g/m Temperature sensor cable(FLY7): 3-core shield cable External sheath: Gray flame-resistant vinyl External diameter: About 6.9 mm Terminal treatment: Round waterproof connector (detector side), M3.5 amplifier terminal (Flow Transmitter side) Weight: About 56 g/m Dimensions: Flow Transmitter : H240 x W247 x D134 mm Detector: H70 x W57 x L360 mm (FSWS12) H72 x W57 x L540 mm (FSWS21) H90 x W85 x L640 mm (FSWS40) H82 x W71 x L258 mm (FSWS50) Mass: Flow Transmitter: 5 kg Detector: 1.7 kg (FSWS12), 1.9 kg (FSWS21), 5 kg (FSWS40), 1.5 kg (FSWS50) Physical specifications Enclosure protection: Flow Transmitter: IP67 , Detector: IP67 Mounting: Flow Transmitter: wall mount Detector: clamped on pipe surface Conditions on straight pipe Classification 10D or more ( D : Inside diameter of pipe) Downstream side L L 10D 5D Upstream side 90 bend Detector L L 50D 10D Tee 10D or more L Diffuser 0.5D or more D 10D or more 30D L 5D 1.5D L Reducer 10D L 5D L Various Valve 30D L 10D In case that flow control valve exists on upstream side. Stop valve Check valve Pump P In case that flow control valve exists on downstream side. L 50D (Note) The source : JEMIS-032 3 FSH, FSW, FLY Measurement principle • Ultrasound pulses are transmitted into a liquid, and f low velocity p rofile i s found a nd t he f low r ate i s measured by using the characteristics that Doppler frequency of the echo from reflectors such as air bubbles and particles in the liquid changes according to flow velocity. Sensor 1 Block diagram (1) Single path system (Z method) Cable Detector 4 to 20mA DC Flow Transmitter Contact (Up to 3 points are allowed.) Temperature sensor cable Power supply Air bubbles Reflection Flow Sensor 2 Flow velocity Profile 2 Flow velocity Profile 1 (2) 2-path system (Z method) Cable Detector Power supply 4 to 20mA DC Flow velocity Piping wall Center Piping wall Flow Transmitter Contact (Up to 3 points are allowed.) Temperature sensor cable • Ultrasound pulses are propagated slanted both from the upstream and downstream, and flow rate is measured by detecting the time difference generated with the flow. Sensor 1 Flow Sensor 2 Transmission Sensor 2 Sensor 1 1 2 ∆T Receiving Time difference Maximum measurement range in hybrid mode When stainless steel is selected as pipe material, nominal wall thickness is Sch20s, and the fluid is water Caliber 40A 50A 65A 80A 90A 100A 125A 150A 200A 250A 300A 350A 400A 450A 500A 550A 600A 650A 700A 750A 800A 850A 900A 1000A FSWS12 6.56 6.52 5.31 4.65 4.12 3.69 3.08 2.63 2.04 FSWS21 FSWS40 Unit: m/s FSWS50 Unit: m3/h FSWS12 FSWS21 FSWS40 FSWS50 33.6 52.7 72.1 86.5 102 118 231 147 289 179 354 239 474 908 604 1168 735 1428 820 1598 951 1858 2118 2358 2358 2618 2879 3096 3357 3618 3879 4140 4400 4902 7.25 6.08 5.20 4.05 3.30 2.78 2.51 2.20 7.77 6.38 5.41 4.90 4.31 3.80 3.48 3.48 3.17 2.91 2.71 2.52 2.35 2.21 2.08 1.97 1.77 4 CODE SYMBOLS 12345678 9 10 11 12 12345678 FSH E Y A Y 1 SYY Description Type (4th digit) Standard Velocity profile output (5th digit) None Available FLY 6 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 1 2 3 4 5 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 0 0 0 0 0 1 Description Kind of cable (4th digit) Coaxial cable (for ultrasonic sensors) Three-core cable (for temperature sensor) Cable length (5th to 7th digit) 5m 10m 15m 20m 25m 30m 35m 40m 45m 50m 55m 60m 65m 70m 75m 80m 85m 90m 95m 100m 110m 120m 130m 140m 150m Length in m to be designated with 3 digits Y Use (6th digit) Single path or Changeover two-path (Note) Note: 2 sets of detectors and coaxial cables (FLY6) needed for two-path system. 1 4 1 S Y Power supply (7th digit) 100 to 240 Vac, 50/60 Hz 20 to 30 Vdc Modification No. (8th digit) Mark 1 Case structure (9th digit) IP67 Conduit connection (10th digit) G1/2 and G3/8 (female screw) with water-proof connection Y Y A B C For use with explosion-proof detector (11th digit) None Parameter setting, Tag Plate (12th digit) None With setting With setting and Tag Plate With Tag Plate 1 Modification No. (8th digit) Mark 1 12345678 9 10 11 F SW S S 1 2 4 5 2 1 0 0 01 Y Description Type (4th digit) Standard Kind of detector (5th and 6th digit) Small diameter detector (φ 40 to 200 mm) Small size detector (φ 100 to 400 mm) Middle size detector (φ 200 to 500 mm) Large size detector (φ 500 to 1000mm) 0 1 Y Y A Y A Use (7th digit) Standard (IP67) Modification No. (8th digit) Mark 1 Signal cable (9th digit) None Acoustic coupler (10th digit) (Note) None Silicone compound Option (11th digit) None Tag Plate (Note) Select silicone compound (A) for acoustic coupler in ordinary cases. Silicon compound is supplied in a tube (150g). If one or more detectors one ordered, silicon compound may be selected onece every 5 orders or so. Loader software for PCs Equipped as standard • Works on PC/AT compatible machines. • Operation o n P C98-series m achines ( NEC) c annot b e guaranteed. • Operation on self-made PCs or shop-brand PCs cannot be guaranteed. • Major functions: Setting/changing of various parameters for the main unit If no flow velocity profile output is selected, the following functions are not available. ”Detailed setting” and ”flow velocity profile display” in pulse Doppler measurement ”Detailed setting” and ”receved signal display” in Transit time measurement • O/S: Windows2000/XP • Memory requirement: 128MB or more • Disk unit: Windows2000/XP-compatible CD-ROM drive • Hard disk drive capacity: Free space of 52MB or more N o t e : P C l o a d e r c o m m u n i c a t i o n c a b l e ( t y p e ZZP*TK4H6253, Specifications: D-sub 9 pin receptacle, cable length 3m) is separately required. Detector frame installation fixture Installation fixture is provided to facilitate the positioning of the frame to the piping. Select a desired type from the following according to the detector to be used. Type ZZP TK7M7071C1 ZZP TK7M7071C2 ZZP TK7M7071C3 Applicable detector FSWS12 FSWS21 FSWS40 Note: The installation fixture cannot be used for detector type FSWS50, which is not provided with a frame. 5 FSH, FSW, FLY OUTLINE DIAGRAM (Unit:mm) 4-φ 9 Mtg. plate 240 Duosonics 3 134 14 72 233 33 33 30 30 30 48 48 24 48 CONNECTION DIAGRAM Power supply terminals (AC) 1 2 3 4 L N 100 to 240V AC Power supply terminals (DC) 1 2 3 4 1 B 2 B 3 A 4 5 SERIAL Cable (Black) Cable (Black) Cable (Yellow/ Green) SERIAL No. 4 5 6 RS485 TRX2 (–) TRX1 (+) SHILD RS232C TXD RXD COM Communication cable (option) Cap (red) Cap (yellow) Cap (black) 6 7 8 9 (273) 352 332 30 + Iout – + – 20 to 30V DC To temp sensor 2 3 4 5 6 7 8 1 HF GND HF GND HF GND HF GND UP STR DOWN STR UP STR DOWN STR LINE1 LINE2 + DO1 1 – 2 + DO2 3 – 4 + DO3 5 – 6 7 Open collector Relay contact * Use LINE1 terminals in case of single measuring path. 6 OUTLINE DIAGRAM (Unit:mm) Connector Temp. sensor Absorber unit Sensor unit (with Temp. sensor) Frame Cursor L Sensor unit (without Temp. sensor) (H) W TYPE FSWS12 FSWS21 PIPE SIZE ø40∼ø200 ø100∼ø400 L 360 540 H 70 72 W 57 57 MASS APPROX 1.7 1.9 Connector Temp. sensor Absorber unit Sensor unit Cursor Frame (with Temp. sensor) 640 Sensor unit (without Temp. sensor) (90) 85 7 FSH, FSW, FLY OUTLINE DIAGRAM (Unit:mm) BNC Connector Temp sensor Sensor unit Absorber unit 258 82 8 73 φ15 φ21.5 BNC Connector Connector φ11 φ7.3 φ6.9 L ± 1 (m) L ± 1 (m) 3-φ6 .6 3-φ6 .6 L: According to the designation of the 5th, 6th, and the 7th digits of the Code Symbols. 34 Connector 67 46 To personal computer SCOPE OF DELIVERY • Flow transmitter (Type: FSH): Flow transmitter CD-ROM (Instruction manual, Loader software) 3.2 ± 0.2 (m) φ6.9 • Detector (Type: FSW): Sensor unit Mounting belt Silicon compound (option) • Signal cable (Type: FLY6): Cable (2 wires) To Flow transmitter • Signal cable (Type: FLY7): Cable for temperature sensor (1) Terminal cap (Red) 3φ6 .6 Terminal cap (Yellow) Terminal cap (Black) Red TXD Yellow Black RXD RS-232C COM ITEMS DESIGNATED ORDERING • Flow transmitter code symbols • Detector code symbols • Signal cable code symbols 9 FSH, FSW, FLY No. 1 2 Setting item Outer diameter Pipe material Settable range 10.00 to 6200.00mm (0.393 to 244.100 inch) 12 menus Pipe S.V. : 1000 to 3700m/s (3280 to 12140 ft/s) Initial value 60.00mm (2.362 inch) PVC Settable value [mm, inch] Carbon steel, Stainless steel, PVC, Copper, Castiron, Aluminum, FRP Ductileiron, PEEK, , PVDF Acrylic , Others (Sound velocity : [m/s, ft/s]) [mm, inch] No lining, Tar epoxy, Mortar, Rubber, Teflon, Pyrex glass, PVC, Others (Sound velocity : [m/s, ft/s]) [mm, inch] Water Water, Seawater, DIST. water, Ammonia, Alcohol, Benzene, Bromide, Ethanol, Glycol, Kerosene, Milk, Methanol, Toluol, Lube oil, Fuel oil, Petrol, Others (Sound velocity : [m/s, ft/s]) (Kinematic viscosity [x10-6m2/s, ft2/s]) m/s, L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s, m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s, BBL/min, BBL/h, BBL/d, KBBL/d, MBBL/d, (ft/s, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d, gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d, BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d) Single, Auto 2, Bi-dir, Bi-dir Auto 2 [ ] PiPing specification 3 4 Wall thickness Lining material 0.10 to 100.00mm (0.003 to 3.940 inch) 8 menus Lining S.V. : 1000 to 3700m/s (3280 to 12140 ft/s) 4.00mm (0.157 inch) No lining 5 6 Lining thickness Kind of Fluid 0.01 to 100.00mm (0.000 to 3.940 inch) 17 menus Fluid S.V. : 500 to 2500m/s (1641 to 8203 ft/s) Kinematic viscosity : 0.001 to 999.9999 x 10-6m2/s (0.0107 to 10763.9088 x 10-6ft2/s) 7 Range unit 19 menus m/s (ft/s) 8 9 Range type Full scale or Full scale 1 4 menus In terms of flow velocity 0.00 ··· 0.30 to 32.00m/s (0.98 to 104.98 ft/s) In terms of flow velocity 0.00 ··· 0.30 to 32.00m/s (0.98 to 104.98 ft/s) 0.00 to 20.0% -20 to 0% 100 to 120% 5 menus 0 to 900sec 0.00 to 5.00m/s (0.00 to 16.40 ft/s) in terms of flow velocity 0 to 900sec 0.0 to 100.0sec 7 menus Single 2.00m/s (6.56 ft/s) 4.00m/s (13.12 ft/s) 10.00% -20% 120% Hold 10sec 0.00m/s (0.00 ft/s) 0sec 5.0sec Flowrate (m3/s) Output setting 10 Full scale 2 [ ] 11 12 13 14 15 16 Range HYS. Output limit LO. Output limit HI. Output burnout Burnout timer Rate limit % % % Not use, Hold, Upper, Lower, Zero sec [ ] 17 18 19 Rate limit timer Damping sec sec Flow velocity, Flowrate, Total forward, Total reverse, F : Total pulse, R : Total pulse, Flow rate (%) 20 Display setting 1 : Display kind 2 : Display kind 7 menus Flow velocity (m/s) Flow velocity, Flowrate, Total forward, Total reverse, F : Total pulse, R : Total pulse, Flow rate (%) 0.01m/s (0.03 ft/s) [ ] 21 Low flow cut 0.00 to 5.00m/s (0.00 to 16.40 ft/s) in terms of flow velocity 10 No. 22 23 Setting item Total mode Total unit 3 menus 8 menus Settable range Initial value Total stop mL Settable value Total stop, Total run, Total reset mL, L, m3, km3, Mm3, mBBL, BBL, kBBL, ft3, kft3, Mft3, kgal, gal, mBBL, BBL, kBBL, ACRF [ [ [ [ [ Not use, Hold sec 50, 100, 200 0.5, 1.0, 2.0, 5.0, 10.0, 20.0, 50.0, 100.0, 200.0 [ ] ] ] ] ] ] 24 25 Total rate F : Total preset 0.000 to 999999.999 0.000 to 9999999999.999 0.000 to 9999999999.999 0.000 to 9999999999.999 0.000 to 9999999999.999 2 menus 0 to 900sec 3 menus 9 menus In terms of flow velocity 0.00 to 32.00m/s (0.00 to 104.98 ft/s) In terms of flow velocity 0.00 to 32.00m/s (0.00 to 104.98 ft/s) 0 to 20% 15 menus 0.000 0.000 0.000 0.000 0.000 Hold 10sec 50ms 50ms 0.00m/s Total Flow switch 26 27 28 29 30 31 32 33 F : Total SW R : Total preset R : Total SW Output burnout Burnout timer Pulse width 1 Pulse width 2 Flow sw high 34 Flow sw low 4.00m/s [ ] 35 36 Flow sw HYS. Output DO1 10% Not use Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error Normal, Reverse Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error Normal, Reverse Not use, Signal error, F : Total pulse, R : Total pulse, F : Total alarm, R : Total alarm, F : Total overflow, R : Total overflow, Flow SW high, Flow SW Low, Full scale2, AO range over, Pulse range over, R : Flow direction, Device error Normal, Reverse % 37 38 Mode DO1 Output DO2 2 menus 15 menus Normal Not use 39 40 Status output Mode DO2 Output DO3 2 menus 15 menus Normal Not use 41 Mode DO3 2 menus Normal 11 FSH, FSW, FLY No. 42 43 44 Serial com. Setting item System unit Language COM. speed COM. parity COM. stop bit Serial method Station No. Measuremant mode Settable range 2 menus 5 menus 3 menus 3 menus 2 menus 2 menus 31 menus 2 menus 3 menus 4 menus Initial value Metric English 38400BPS None 1 bit RS232C 1 1 Path Line 1 FSW12 Settable value Metric, English Japanese, English, German, French, spanish 9600BPS, 19200BPS, 38400BPS None, Even, Odd 1 bit, 2bits RS232C, RS485 1 to 31 1 Path, 2 Path Average, Line 1, Line 2 FSW12, FSW21, FSW40, FSW50 45 46 47 48 49 50 51 System Measurement mode AO Definition Sensor Type Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1 and 2 shown below are satisfies. Condition 1 : Flow span-1*[m3/s] total pulse value*[m3] Flow span-1*[m3/s] total pulse value*[m3] 1000 [In the case of DO1 and DO2] 1 [In the case of DO3] 1000 2 × total pulse width [ms] Condition 2 : * In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan
EDS6-132F 价格&库存

很抱歉,暂时无法提供与“EDS6-132F”相匹配的价格&库存,您可以联系我们找货

免费人工找货