0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDS6-69B

EDS6-69B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS6-69B - INTEGRAL TYPE ELECTROMAGNETIC FLOWMETER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS6-69B 数据手册
INTEGRAL TYPE ELECTROMAGNETIC FLOWMETER DATA SHEET The electromagnetic flowmeter is an instrument to measure the volumetric flow rate of liquid simply by applying a magnetic field from the outside utilizing the fact that an electric conductor which crosses a magnetic field at a certain velocity causes voltage to be induced in proportion to the velocity, which is known as Faraday’s law. This flowmeter is designed with the latest electronics technology and magnetic/electric field analyzing technology, realizing a compact and light-weight structure and measurement with high accuracy. FMA1, 2 FEATURES 1. High accuracy The adoption of the optimum magnetic field design using the 3-dimentional finite element method has minimized the effects of flow velocity profile and materials of adjacent piping. At flow velocity of more than 1m/sFS,the measurement accuracy is as high as ± 0.5% of indicatedvalue when the flow is above 20%FS. 2. Wide range Measurement range: 0 to 0.1 ... 15m/sec in flow velocity 3. High-reliability structure The converter case is a sealed 2-chamber structure, practically free from dew condensation and sudden submergence. The adoption of stainless housing assures excellent anti-environment efficiency. 4. Easy-to-see display LCD with back-light allows easy check of display even in a dark place. Instantaneous flow and integral volmetric flow are displayed at the same time. 5. Free power supply The flowmeter operates on power supply 100 to 240V AC, 50/60 Hz, eliminating the need for selection of power voltage. 6. Application of international standards The overall length of flange type flowmeter conforms with ISO draft standards. (Meter size : 6A-200A) Meter size 2.5A Note 3) 6A 15A 25A 40A 50A 80A 100A 150A 200A 250A 300A • Mounting method : Mounted via flange insertion type on opposite (wafer type) (with Guide rings) ··· 2.5 to 200A Note 1) Guide ring : A ring-shaped guide used for centering the sensor when a water type is mounted on the piping. or flange mounting ··· 6 to 300A Note 2) Flange with meter size 2.5A or 6A can be used for 15A. • Liquid pressure : -100 to 2000kPa or flange operating • Meter size and measurement range Measuring range is equivalent to flow velocity 0.1 to 15m/s. Min.measurement range [m3/h] 0 to 0.00177 0 to 0.0102 0 to 0.0637 0 to 0.177 0 to 0.453 0 to 0.707 0 to 1.81 0 to 2.83 0 to 6.37 0 to 11.3 0 to 17.7 0 to 25.5 Max. measurement range [m3/h] 0 to 0.265 0 to 1.52 0 to 9.54 0 to 26.5 0 to 67.8 0 to 106 0 to 271 0 to 424 0 to 954 0 to 1696 0 to 2650 0 to 3817 SPECIFICATIONS Sensor • Measurement item : General-use industrial water, tap-water, sewage, waste water, chemicals slurry, and other liquids with conductivity of more than 3µs/cm. • Structure : Wafer type or flange type Note) Meter size 2.5A: Wafer type only EDS6-69b Date Oct. 29, 2001 FMA1, 2 • Liquid temperature : –10 to +120˚C (Tefron lining) –10 to +50˚C (Polyurethane lining) [˚C] Tefron lining Liquid temperature 120 80 50 Polyurethane lining -10 -20 20 50 60 [˚C] Ambient tempertaure Ambient temperature-liquid temperature allowable range • Material : Parts in contact with Liquid Note 1) Lining Electrode Tefron(PFA, TFE) SUS316L Hasteroy C Titanium Tantalum Platinum iridium SUS316 Hasteroy C Titanium Tantalum SUS304 SUS304 or carbon steel Polyurethane SUS316L Earth ring SUS316 Housing case Flange Note 2) Note 1) Materials of parts in contact with liquid should be selected in consideration of erosion due to measuring liquid. Refer to the table of material selection on the attached sheet. Note 2) Flange type only SUS304: Unpainting Carbon steel: Polyurethane corrosion-resistant painting (Silver) Conveter • Exciting system : Square low-frequency exciting • Input/output signal : Current output; 4 to 20mA DC Load rasistance 0 to 1KΩ Pulse output; open-collector Capacity; DC30V, 0.2A or less ON voltage; 0.6V or less 0.0001 to 1000P/s Status output; open-collector Capacity: DC30V, 0.2A or less ON voltage; 2V or less Status input; no- voltage contact Note) Status signal input or output, either one, can be • Pulse output : Integrated pulses are outputted by setting integral constant. Pulse width 0.5 to 80ms • Span setting : Flow FS can be set by setting flow unit and flow value. Flow velocity can also be set. Display cubic volume, length; m3, L, mL, m Display time unit ; /d, /h, /min, /s • Multi-range : Automatic 2-range selection in 2-range select mode. External 2-range selection with status input is possible. • Flow direction change : Flow direction can be reversed in flow direction mode. • Flow display : Real time flow display, % display or user unit display is possible in 7 codes, max. • Integration display : Integrated volumetric flow can be displayed by setting the unit of cubic volume. Displayed cubic volume; m3, L, mL • Fault diagnosis turction : Various faults can be diagnosed by hardware check and process check. • Zero point adjustment : Zero point is automatically calibrated with one-push operation. • Output low cut : 0 to 10% FS Momentary output can be cut to 0% at flow rate below the set cutoff point. • Integration low cut : 0 to 10% FS Integration of display and output are prevented at flow rate below the set cutoff point. • 0% signal lock : Display and output can be locked to 0% with status input. • Slurry noise cut : 0 to 10% FS, 0 to 60 sec Slurry noise (spike noise) can be cut by setting rate limit. • Empty detection : Absence of liquid is detected and status signal is outputted. • Flow switch : –10 to 110% FS Status signal is outputted by setting high/ low limit flow. • Dumping time constant : 1 to 200 sec • Converter case : Aluminum alloy • Arrester : Built-in power supply arrester and current output arrester • Wiring connection port : G1 /2, NPT1 /2, Pg 13,5, M20 x 1,5 • Painting : Body case; Polyurethane corrosion-resistant painting (Silver) Body cover; Polyurethane corrosion-resistant painting (Blue) • Structure : JIS C 0920 immersion-proof (IP67) • Grounding : D-class grounding (100Ω or less) 2 OTHER SPECIFICATIONS When replacing Fuji' s former type sensors, flanges with short pipe are available. For details, contact our office. Standard performance • Accuracy rating : Meter size 2.5A to 15A 25A to 200A Flow velocity≥20%FS: _ ±0.5% of rate Flow velocity
EDS6-69B 价格&库存

很抱歉,暂时无法提供与“EDS6-69B”相匹配的价格&库存,您可以联系我们找货

免费人工找货