EDS6-70B

EDS6-70B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDS6-70B - SEPARATE TYPE ELECTROMAGNETIC FLOWMETER - Fuji Electric

  • 数据手册
  • 价格&库存
EDS6-70B 数据手册
SEPARATE TYPE ELECTROMAGNETIC FLOWMETER DATA SHEET The electromagnetic flowmeter is an instrument to measure the volumetric flow rate of liquid simply by applying a magnetic field from the outside utilizing the fact that an electric conductor which crosses a magnetic field at a certain velocity causes voltage to be induced in proportion to the velocity, which is known as Faraday’s law. This flowmeter is designed with the latest electronics technology and magnetic/electric field analyzing technology, realizing a compact and light-weight structure and measurement with high accuracy. FMB1, 2/ FMC FEATURES 1. High accuracy The adoption of the optimum magnetic field design using the 3-dimentional finite element method has minimized the effects of flow velocity profile and materials of adjacent piping. At flow velocity of more than 1m/sFS,the measurement accuracy is as high as ± 0.5% of indicatedvalue when the flow is above 20%FS. 2. Wide range Measurement range: 0 to 0.3 ... 15m/sec in flow velocity 3. High-reliability structure The sensor terminal box is a sealed 2 - chamber structure, practically free from dew condensation and sudden submergence. The adoption of stainless housing assures excellent anti-environment efficiency. 4. Easy-to-see display LCD with back-light allows easy check of display even in a dark place. Instantaneous flow and integral volumetric flow are displayed at the same time. 5. Free power supply The flowmeter operates on power supply 100 to 240V AC, 50/60 Hz, eliminating the need for selection of power voltage. 6. Application of international standards The overall length of flange type flowmeter conforms with ISO draft standards. (Meter size : 6A-200A) Meter size 2.5A Note 3) 6A 15A 25A 40A 50A 80A 100A 150A 200A 250A 300A Min.measurement range [m3/h] 0 to 0.00531 0 to 0.0306 0 to 0.191 0 to 0.531 0 to 1.36 0 to 2.13 0 to 5.43 0 to 8.49 0 to 19.1 0 to 34.0 0 to 53.1 0 to 76.4 Max. measurement range [m3/h] 0 to 0.265 0 to 1.52 0 to 9.54 0 to 26.5 0 to 67.8 0 to 106 0 to 271 0 to 424 0 to 954 0 to 1696 0 to 2650 0 to 3817 • Mounting method : Mounted via flange insertion type on opposite side (wafer type)(with Guide rings) ··· 2.5 to 200A Note 1) Guide ring : A ring-shaped guide used for centering the sensor when a water type is mounted on the piping. or flange mounting ··· 6 to 300A Note 2) Flange with meter size 2.5A or 6A can be used for 15A. • Liquid pressure : -100 to 2000kPa or flange operating • Meter size and measurement range : Measuring range is equivalent to flow velocity 0.3 to 15m/s. SPECIFICATIONS Sensor (Type : FMB) • Measurement item : General-use industrial water, tap-water, sewage, waste water, chemicals slurry, and other liquids with conductivity of more than 3u/cm • Structure : Wafer type or flange type Note) Meter size 2.5A: Wafer type only EDS6-70b Date Oct. 29, 2001 FMB1, 2/ FMC • Liquid temperature : –10 to +120˚C (Tefron lining) –10 to +50˚C (Polyurethane lining) [˚C] Tefron lining Liquid temperature 120 80 50 Polyurethane lining -10 -20 20 50 60 [˚C] Ambient tempertaure Ambient temperature-liquid temperature allowable range • Material : Parts in contact with Liquid Note 1) Lining Electrode Tefron(PFA, TFE) SUS316L Hasteroy C Titanium Tantalum Platinum iridium SUS316 Not L Hasteroy C Titanium Tantalum SUS304 SUS304 or carbon steel Aluminum alloy Polyurethane SUS316L Earth ring SUS316 Not L Housing case Flange Note 2) Terminal box case Note 1) Materials of parts in contact with liquid should be selected in consideration of erosion due to measuring liquid. Refer to the table of material selection on the attached sheet. Note 2) Flange type only • Pipingconnection port : G1/2, NPT 1/2, Pg 13,5, M20×5 Terminal box case; Polyurethane corro• Painting : sion-resistant painting (Silver) Cover; Polyurethane corrosion-resistant painting (Blue) Flange; SUS304 type is unpainting. Carbon steel type is polyurethane corrosion-resistant painting (Silver). • Structure : JIS C 0920 immersion-proof (IP67) • Grounding : D-class grounding (100Ω or less) Conveter (Type FMC) • Mounting method : Pipe or wall mounting • Exciting system : Square low-frequency exciting • Input/output signal : Current output; 4 to 20mA DC Load rasistance 0 to 1KΩ Pulse output; open-collector Capacity; DC30V, 0.2A or less ON voltage; 0.6V or less 0.0001 to 1000P/s Status output; open-collector Capacity: DC30V, 0.2A or less ON voltage; 2V or less Status input; no-voltage contact Note) Status signal input or output, either one, can be • Pulse output : Integrated pulses are outputted by setting integral constant. Pulse width 0.5 to 80ms • Span setting : Flow FS can be set by setting flow unit and flow value. Flow velocity can also be set. Display cubic volume, length; m3, L, mL, m Display time unit ; /d, /h, /min, /s • Multi-range : Automatic 2-range selection in 2-range select mode. External 2-range selection with status input is possible. • Flow direction change : Flow direction can be reversed in flow direction mode. • Flow display : Real time flow display, % display or user unit display is possible in 7 codes, max. • Integration display : Integrated volumetric flow can be displayed by setting the unit of cubic volume. Displayed cubic volume; m3, L, mL • Fault diagnosis function : Various fault can be diagnosed by hardware check and process check. • Zero point adjustment : Zero point is automatically calibrated with one-push operation. • Output low cut : 0 to 10% FS Momentary output can be cut to 0% at flow rate below the set cutoff point. • Integration low cut : 0 to 10% FS Integration of display and output are prevented at flow rate below the set cutoff point. • 0% signal lock : Display and output can be locked to 0% with status input. • Slurry noise cut : 0 to 10% FS, 0 to 60 sec Slurry noise (spike noise) can be cut by setting rate limit. • Empty detection : Absence of liquid is detected and status signal is outputted. • Flow switch : –10 to 110% FS Status signal is outputted by setting high/ low limit flow. • Dumping time constant : 1 to 200 sec • Converter case : Aluminum alloy • Arrester : Built-in power supply arrester and current output arrester • Wiring connection port : G 1/2, NPT 1/2, Pg 13,5, M20 x 1,5 • Painting : Body case, terminal box case or cover; Polyurethane corrosion-resistant painting (Silver) Body cover; Polyurethane corrosion-resistant painting (Blue) • Structure : JIS C 0920 immersion-proof (IP67) • Grounding : D-class grounding (100Ω or less) • Mass : 3.5kg 2 • Length of special signal cable: 150m or less (see diagram below) 150 100 50 OTHER SPECIFICATIONS When replacing Fuji' s former type sensors, flanges with short pipe are available. For details, contact our office. For specifications of special water-proof type, etc., contact our office. Standard performance • Accuracy rating : Cable length [m] 10 Meter size 2.5A to 15A 25A to 200A _ Flow velocity≥20%FS: ±0.5% of rate Flow velocity Ground Electrode mounting position e Use of a bypass valve will provide easy zero adjustment and maintenance. Install a bypass line so that fluid flow is not interrupted. A bypass line installed as illustrated in following figure (a) and (b) allows the inside of the pipe to be washed and cleaned without removing the flowmeter. Bypass Detector Stop valve Stop valve FLOW Short pipe Detector Short pipe Coupling flange FLOW Bypass (a) Horizontal bypass line (b) Vertical bypass line 5 FMB1, 2/ FMC Material selection table The following table indicates examples of recommended materials, contacting with liquid, to be used with the typical liquids measured with electromagnetic flowmeter. Evaluation of those materials has been conducted according to various documents and experience in actual use. 1. Characteristics of lining materials Material Teflon PFA Teflon TFE Abrasion resistance Heat resistance Corrosion resistance [ Adhesion resistance : Excellent, : Very good, : Good, : No good] Remarks Ideal for the use with corrosive or adhesive fluids. Not suitable for abrasive fluid (such as slurry.) Pay attention to permeability of TFE. Note that TFE is not suitable for use with hightemperature + negativepressure fluid. Has inferior heat resistance or corrosion resistance. Best for slurry or the like with no corrosive properties. Poly-urethane 2. Material selection table of electrode/earth ring Material SUS316 Measurable liquid Water and waste water, weak acid, weak alkali Example: 25% acetic acid or less, hydroiodic acid, butyric acid, aqueous ammonia or alike Suitable for intermediate oxidation and reduction and can be used for various fields. Example: Sea water, formic acid, acetic acid, aqueous ammonia, normal-temperature (lower than 40°C) nitric acid, hydrochloric acid and sulfuric acid or alike Resistant to sea water, most oxidative acids, chloride, sulfide and alkali. Example: Sea water, saline water, aqueous ammonia, chlorine water, polyelectrolyte, acetic acid, ferric chloride or alike Resistant to most chemicals. (particularly, strong acids) Example: Hydrochloric acid, sulfuric acid, nitric acid, aqua regia, ferric chloride, hypochlorous acid, sodium hypochlorite, PAC (Polyaluminum chloride) or alike Resistant to almost chemicals. Unmeasurable liquid Inorganic acid, organic acid, chloride or alike Hastelloy C-276 or equivalent Chloride, high-temperature strong acids (nitric acid, hydrochloric acid, sulfuric acid), high temperature (higher than 40°C) or high concentration (more than 40%) ferric chloride or alike Reductive acids such as hydrochloric acid, sulfuric acid, phosphoric acid, oxalic acid Titanium Tantalum Sodium hydroxide, potassium hydroxide, hydroflouric acid, fuming sulfuric acid or alike Platinum-iridium (Pt-Ir) Aqua regia 6 CODE SYMBOLS Separate type electromagnetic flowmeter sensor (wafer type) 12345678 9 10 11 12 13 14 F MB 1 S A C D T E F G H J P U 1- 0 0- Description Meter size (5th code) 2.5A 6A 15A 25A 40A 50A 80A 100A 150A 200A Lining material (6th code) PFA mold Tefron Polyurethane rubber (7th & 9th code; W only) Note) Polyurethane rubber with less than 15A of meter size cannot be used. W H C T W H C T P 0 1 2 7 5 6 8 9 A B Earth ring material (7th code) SUS316 Hasteroy C Titanium Tantalum Electrode material (9th code) SUS316L Hasteroy C Titanium Tantalum Platinum iridium Flange (10th code) None Guide ring (11th code) For JIS 10K For JIS 200K For JIS 75M (inside diameter of less than 50A cannot be used) For ANSI 150LB For ANSI 300LB For DIN/PN 16K For DIN/PN 40K Wiring connection port size (12th code) G1/2(PF1/2) female screw with water-proof gland G1/2(PF1/2) female screw with union and water-proof gland NPT1/2 female screw Pg 13.5 female screw M20 ×1.5 female screw 0 Y A Application (13th code) General type Optional specifications (14th code) None Stainless tag plate C D E 7 FMB1, 2/ FMC Separate type electromagnetic flowmeter sensor (flange type) 12345678 9 10 11 12 13 14 F MB 2 A C D T E F G H J K L 1- 0 0- Description Meter size (5th code) 6A Note 15A 25A 40A 50A 80A 100A 150A 200A 250A 300A Note) Flange size for meter size 6A is 15A or 1/2B. P T U Lining material (6th code) PFA mold Tefron Note 1 TFE Tefron Note 2 Polyurethane rubber Note 3 (7th & 9th codes: W only) Note 1) PFA 6A to 200A Note 2) TFE 250A, 300A Note 3) Polyurethane rubber with less than 15A of meter size cannot be used. W H C T W H C T P 1 2 4 5 6 7 8 A B D E F G H Earth ring material (7th code) SUS316 Hasteroy C Titanium Tantalum Electrode material (9th code) SUS316L Hasteroy C Titanium Tantalum Platinum iridium Flange standard Flange material JIS 10K SUS304 JIS 20K SUS304 JIS 75M SUS304 Note 2 ANSI 150LB SUS304 ANSI 300LB SUS304 DIN PN16 SUS304 DIN PN40 SUS304 Note 1 JIS 10K Carbon steel JIS 20K Carbon steel Note 3 JIS 75M Carbon steel Note 2 ANSI 150LB Carbon steel ANSI 300LB Carbon steel DIN PN16 Carbon steel DIN PN40 Carbon steel Note1 Note 1) Mater size 100A or more cannot be used. Note 2) Mater size 50A or less cannot be used. Note 3) Mater size 250A or 300A can be selected only for A, B and D. 0 A B C D E 1 2 Y A Guide ring (11th code) None Wiring connection port size (12th code) G1/2(PF1/2) female screw with water-proof gland G1/2(PF1/2) female screw with union and water-proof gland NPT1/2 female screw Pg 13.5 female screw M20×1.5 female screw Direction of indicator (13th code) Horizontal mounting Vertical mounting Optional specifications (14th code) None Stainless tag plate 8 Converter (separate type) 12345678 9 10 11 12 13 F MC 1 N 1 N A B Y A B C D E 1- Description Application (4th code) General use Power supply (5th code) AC100 to 240V 50/60Hz Mounting method (6th code) Pipe mounting Wall mounting Wiring connection port size (7th code) G1/2(PF1/2) female screw G1/2(PF1/2) female screw with water-proof gland G1/2(PF1/2) female screw with union and water-proof gland NPT1/2 female screw Pg 13.5 female screw M20×1.5 female screw Y A Optional specifications (9th code) None Parameter setting Note) When parameter setting function is used, specify parameters in parameter designation tables 1 and 2. Y A 000 005 010 015 020 025 030 035 040 050 060 070 080 090 100 110 120 130 140 150 Cable end treatmen (10th code) Without cable end treatment With cable end treatment Cable length (11 to 13th code) 0 5m 10m 15m 20m 25m 30m 35m 40m 50m 60m 70m 80m 90m 100m 110m 120m 130m 140m 150m 9 FMB1, 2/ FMC OUTLINE DIAGRAM (Unit: mm) (Wafer type sensor) Wiring lead-in port A 66 ø98 *2 *1 *1 With water-proof gland *2 With union and water-proof gland H ød W±2 Note) When earth ring material is tantalum, W is shortened by 4mm. Detail of "A" (Stainless tag) Option ø15 G1/2 øD 15 5 20 Mater size 2.5A 6A 15A 25A 40A 50A 80A 100A 150A 200A W 85 85 85 93 100 105 150 160 190 205 ød 2.5 6 12 22.6 35.6 47.8 72.3 97.6 150 200 øD 50 50 50 68 86 96 125 160 211 271 H 231 231 231 249 267 277 306 351 402 462 Mass (Kg) 2 2 2 2.5 3.5 4 7.5 10 14.5 24.5 G M 1/2 L1 13.5 16 10.5 16 L2 18.5 21 15 21 NPT 1/2 Pg13.5 M20 × 1 10 75 OUTLINE DIAGRAM (Unit: mm) (Flange type sensor) 66 *1 : With water-proof gland *2 : With union and water-proof gland ø98 Wiring lead-in port A *2 *1 øC Eye-bolt, inside diameter 80A or more ød H øG F N-øB T W1 Inside diameter 80A or more W2 0 –3 +1 –3 Note) When earth ring material is tantalum, W2 is shortened by 4mm. JIS Flange Meter size W1 W2 øD øC N-øB T øG ød H F Mass (Kg) øD øC N-øB JIS 20K flange T øG ød H F Mass (Kg) øD øC N-øB T JIS 75M øG flange ød H F Mass (Kg) 6A(Note1) 200 206 95 70 4-15 12 46 6 253 – 3.5 95 70 4-15 14 46 6 253 – 3.5 – – – – – – – 15A 200 206 95 70 4-15 12 46 12 253 – 3.5 95 70 4-15 14 46 12 253 – 3.5 – – – – – – – 25A 200 206 125 90 4-19 14 66 22.6 277 – 5.5 125 90 4-19 16 66 22.6 277 – 6 – – – – – – – 40A 200 206 140 105 4-19 16 82 35.6 294 – 7.5 140 105 4-19 18 82 35.6 294 – 8 – – – – – – – 50A 200 206 155 120 4-19 16 92 47.8 306 – 8.5 155 120 8-19 18 92 47.8 306 – 8.5 – – – – – – – 80A 200 206 185 150 8-19 18 121 72.3 336 102 14.5 200 160 8-23 22 121 72.3 343 108 16.5 211 168 4-19 18 121 72.3 349 113 17 100A 250 256 210 175 8-19 18 152 97.6 376 112 18.5 225 185 8-23 24 152 97.6 383 118 21.5 238 195 4-19 18 152 97.6 390 124 21.5 150A 300 306 280 240 8-23 22 202 150 436 144 32.5 305 260 12-25 28 202 150 449 160 39 290 247 6-19 22 202 150 441 163 34.5 200A 350 356 330 290 12-23 22 260 200 491 179 49 350 305 12-25 30 260 200 501 179 57.5 342 299 8-19 22 260 200 497 176 52 20 Detail of "A" JIS 10K flange 15 5 (Stainless tag) Option M G 1/2 NPT 1/2 L1 13.5 16 10.5 16 75 L2 18.5 21 15 21 Pg13.5 M20 × 1.5 – – – – – Note 1 : For meter size 6A, use flange JIS 15A. ø15 G1/2 øD 11 FMB1, 2/ FMC ANSI flange Meter size W1 W2 øD øC N-øB T ANSI 150LB øG flange ød H F Mass (Kg) øD øC N-øB T ANSI 300LB øG flange ød H F Mass (Kg) 1 (Note2) –B 4 200 206 89 60.3 4-16 11.5 46 6 250 – 3 95 66.7 4-16 14.5 46 6 253 – 3.5 –B 2 200 206 89 60.3 4-16 11.5 46 12 250 – 1 1B 200 206 108 79.4 4-16 14.5 66 22.6 269 – 5 1–B 2B 3B 4B 6B 8B 2 200 200 200 250 300 350 206 206 206 256 306 356 127 152 191 229 279 343 98.4 120.6 152.4 190.5 241.3 298.4 4-16 4-20 4-20 8-20 8-23 8-23 17.5 19.5 24 24 25.5 29 82 92 121 152 202 260 35.6 47.8 72.3 97.6 150 200 287 305 339 385 436 498 – – 104 120 144 176 7 9 17 22.5 33.5 56.5 1 3 95 66.7 4-16 14.5 46 12 253 – 3.5 124 156 165 210 254 318 381 88.9 114.3 127 168.3 200 269.9 330.2 4-20 4-23 8-20 8-23 8-23 12-23 12-26 17.5 21 22.5 29 32 37 41.5 66 82 92 121 152 202 260 22.6 35.6 47.8 72.3 97.6 150 200 348 398 455 517 277 302 311 – – – 112 130 165 193 6 9.5 10 20 30 48.5 76.5 Note 2 : For meter size 1/4B, use flange ANSI 1/2B. DIN flange Meter size W1 W2 6A(Note3) 200 206 øD 95 øC 65 N-øB 4-14 16 T øG 46 ød 6 H 253 – F Mass 4 (Kg) øD øC N-øB T øG ød H F Mass (Kg) 95 65 4-14 16 46 6 253 – 4 15A 200 206 95 65 4-14 16 46 12 253 – 4 95 65 4-14 16 46 12 253 – 4 25A 200 206 115 85 4-14 18 66 22.6 272 – 6 115 85 4-14 18 66 22.6 272 – 5.5 40A 200 206 150 110 4-18 18 82 35.6 299 – 8.5 150 110 4-18 18 82 35.6 299 – 8.5 50A 200 206 165 125 4-18 20 92 47.8 311 – 10 165 125 4-18 20 92 47.8 311 – 10 80A 100A 150A 200A 200 250 300 350 206 256 306 356 200 220 285 340 160 180 240 295 8-18 8-18 8-22 12-22 20 20 22 24 121 152 202 260 72.3 97.6 150 200 343 381 439 496 108 116 151 175 16.5 200 160 8-18 24 121 72.3 343 108 17.5 20 – – – – – – – – – 33 – – – – – – – – – 52 – – – – – – – – – DIN PN16 flange DIN PN40 flange Note 3 : For meter size 6A, use flange DIN 15A. 12 OUTLINE DIAGRAM (Unit: mm) *1 : With water-proof gland *2 : For plica tube PV-5#17 with union and water-proof gland Wiring lead-in port A ø98 66 Eye-bolt M10 *2 *1 N-øB H H1 W1 Flange W±3 T Detail of "A" Option ø15 M Meter size W W1 H H1 øD JIS 10K Flange øC N-øB T Mass (Kg) øD øC JIS 20K Flange N-øB T Mass (Kg) øD øC JIS 75M N-øB Flange T Mass (Kg) 250 A 595 320 548 220 400 355 12-25 36 95 430 380 12-27 46 98 410 360 8-23 36 95 300 A 595 360 603 250 445 400 16-25 38 113 480 430 16-27 48 118 464 414 10-23 38 113 G M 1/2 L1 L2 20 L1 13.5 16 10.5 16 L2 18.5 21 15 21 NPT 1/2 Pg13.5 M20 × 1.5 75 øD øC 13 FMB1, 2/ FMC OUTLINE DIAGRAM (Unit: mm) (Pipe mount type converter) 192 180 108 70 107 43 49 U-bolt M8 41 ZERO ADJ. 316 260 *1 : With water-proof gland *2 : With union and water-proof gland 160 *1 Wiring lead-in port A *2 Mounting pipe JIS2B Detail of "A" 30 52 Mass 3.5kg ø15 5 50 50 G1/2 (Wall mount type converter) 192 180 24 12 Mounting hole4-ø9 24 15 50 124 104 2.5 80 32 ZERO ADJ. 260 (*1=270) (*2=287) 314 290 160 Mounting bracket *1 : With water-proof gland *2 : With union and water-proof gland *1 Wiring lead-in port A *2 Mass 3.5kg Detail of "A" 52 30 ø15 5 50 50 G1/2 14 15 50 Power supply Intagrated pulse output [Special signal cable (3-core, double shield cable)] Converter EC EX C A SA SB B L N 0+ PLS+ ST+ 0- PLS- ST- – Current output + Status input/ output Special signal cable Sensor EC Excitation cable EX B C A FLOW RATE-FLOW VELOCITY CONVERSION DIAGRAM 15.0 10.0 5.0 Flow velocity [m/ s] 1.0 0.5 0.3 0.005 0.01 2. 5A 6A 15 A 25 A 40 A 50 A A 0A 80 10 15 0A 00A 50A 00A 22 3 0.05 0.1 0.5 1 3 Flow rate [m / h] 5 10 50 100 500 1000 4000 SCOPE OF DELIVERY Sensor × 1 (mounting bolt and packing should be prepared separately) Converter × 1 (with pipe mounting or wall mounting bracket) Special signal cable × 1 (as specified; excitation cable shouldbe prepared separately) ACCESSORY • Spare fuse (1A) 1 • Guide rimgs / for wafer type (Note) • 1set spare water-proof gland (for water-proof gland type) Note) Not supplied for 2.5A-25A ANSI 150LB and 100A, 200A JIS 10K. ITEMS SPECIFIED AT ORDERING 1. Type, specification code 2. Flow measurement range and mesurement fluid 3. Stainless tag plate, and tag No. (less than 16 alphanumeric characters). 4. If you want the instrument with certain parameters factory set as you desire, submit the parameter designation tables 1 and 2 when specifying them. 15 FMB1, 2/ FMC If you want the instrument with certain parameters factory set as you desire, specify them in parameter designation tables 1 and 2. Company : Name : Measured fluid : Standard set value Setting item (Note 1) Damping 3.0s LCD Real scale 1st line indication indication Unit: Factory set as per range designation Sector : Telephone No. : Put check marks into Range 1.0 to 200.0s q Flow velocity indication (m/s) w Real scale Volume unit: mL, L, m3 Time unit: /s, /min, /h, /d e Percent indication (%) which precede items to modify for. Item selection or value designation _ _ _._ [s] According to selection of left item, Select an item from the following. designate necessary item and value. □Flow velocity indication Unit: m/s fixed. □Real scale indication Volume unit: □mL, □L, □m3 Time unit: □/s, □/min, □/h, □/d None. □Percent indication □Arbitrary unit indication User factor: ______ Or, for mass flow rate indication, designate the density of measured fluid instead of user factor. Density of fluid:_ _ _ _ _ User unit: ______ Item to select 3 Example 020.0s r Arbitrary unit indication User factor: 0.0001 to 99999. User unit: Up to six ASCII code characters. • Must be designated for mass flow rate indication, etc. • If mass flow rate indication (*) □Integrated real scale indication is designated, designate the □Integrated pulse indication density of measured fluid □Integration arbitrary unit instead of user factor.  indication t Integrated real scale indication Volume unit: mL, L, m3 y Integrated pulse indication • Separately designate the “integration constant” together. LCD 2nd line indication Percent indication u Integration arbitrary unit indication User factor: 0.0001 to 99999. User unit: Up to four ASCII code characters. • Must be designated for mass flow rate indication, etc. • If mass indication (*) is designated, designate the density of measured fluid instead of user factor. i Status I/O indication Indication of function and action of status I/O selected on 2nd line of LCD (can specify 2nd line only). o NO FUNCTION Do not indicate LCD 2nd line (can specify 2nd line only). (*): Electromagnetic flow meter is a volumetric flow meter. In case of mass or mass flow rate indication, therefore, any change of density of measured fluid causes an error. Range designated 0.1 to 15 m/s at order placing converted to flow velocity. 0.9765 t/h Volume unit:□mL, □L, □m * Designate “integration constant” separately. User factor: ______ Or, for mass flow rate indication, designate the density of measured fluid instead of user factor. 0.9765 Density of fluid:_ _ _ _ _ User unit: t ______ According to selection of left item, designate necessary item and value. Unit: m/s fixed. Volume unit: □mL, □L, □m3 Time unit: □/s, □/min, □/h, □/d None. User factor: ______ Or, for mass flow rate indication, designate the density of measured fluid instead of user factor. 0.9765 Density of fluid:_ _ _ _ _ User unit: t/h ______ Volume unit:□mL, □L, □m3 * Designate “integration constant” separately. User factor: ______ Or, for mass flow rate indication, designate the density of measured fluid instead of user factor. 0.9765 Density of fluid:_ _ _ _ _ User unit: t ______ None. None. Must be designated in 4 significant digits. 100.0 Value:_ _ _ _ _ Select an item from the following. □Flow velocity indication □Real scale indication □Percent indication □Arbitrary unit indication □Integrated real scale indication □Integrated pulse indication □Integration arbitrary unit  indication 1st range Instantaneous output low-cut point Current output burnout Integration direction Integration constant (Note 2) (integration value per pulse) Integrated pulse width (Note 3) Integration preset value □Status I/O indication □NO FUNCTION Volume unit:□mL, □L, □m3 Time unit: □/s, □/min,      □/h, □/d None. 0.0% UNDER SCALE (2.4mA) FORWARD 0m3 0.0% to 10.0% NOT USED (hold) OVER SCALE (21.6mA) UNDER SCALE (2.4mA) FORWARD REVERSE Value: 0.000000000 to 9999999999. Unit : mL, L, m3 0.5 to 80ms □NOT USED □OVER SCALE □UNDER SCALE □FORWARD □REVERSE Volume unit: □mL, □L, □m3 _ _ . _% None. 3.5% None. Value: __________ 30ms None. _ _ . _ [ms] 50.0[ms] 0m3 Value: –9999999999 to +9999999999 Unit : Linked with unit of integration constant. None. __________ 100000 (Note 1) Standard set value refers to parameter set value as factory set in case parameter setting is not designated. (Note 2) Designate so that 0.0001 to 1000 pulses integrated will be output per second (so that following expression will hold) when flow rate is maximum. 0.0001≦range [m3/h] / (integration constant [m3] × 3600) ≦1000 (Note 3) Designate the integrated pulse width so as to hold: (Integration constant [m3]) × 3600/range [m3/h] ≧ integrated pulse width [ms]/500 16 Standard set value Item selection or Setting item Range Item to select Example (Note 1) value designation 3.0% 0.0 to 10.0% _ _._ [%] Integration 5.0% None low-cut point HOLD HOLD None Integration □HOLD COUNT burnout □COUNT NO FUNCTION According to selection on the left, Status Select one of functions designate item and value. function below. None q NO FUNCTION □NO FUNCTION Must be designated in 4 significant digits. w External 2 range changeover □External 2 range 2nd range: _ _ _ _ • 2nd range: 0.1 to 15 m/s 10.00 changeover Volume unit: □mL, □L, □m3 converted to flow velocity. Time unit: □/s, □/min, □/h, □/d • Status input: □INPUT CLOSED INPUT CLOSED (Note 4) □INPUT OPEN INPUT OPEN e External forward/reverse range changeover □External forward/reverse Must be designated in 4 significant digits. • 2nd range: 0.1 to 15 m/s 2nd range: _ _ _ _ 10.00 range changeover converted to flow velocity. Volume unit: □mL, □L, □m3 Time unit: □/s, □/min, □/h, □/d • Status input: □INPUT CLOSED INPUT CLOSED (Note 4) □INPUT OPEN INPUT OPEN □INPUT CLOSED r 0% signal lock □0% signal lock □INPUT OPEN • Status input: INPUT CLOSED (Note 4) INPUT OPEN t External zero adjustment □External zero adjustment □INPUT CLOSED □INPUT OPEN • Status input: INPUT CLOSED (Note 4) INPUT OPEN □INPUT CLOSED □External integration y External integration preset □INPUT OPEN preset • Status input: INPUT CLOSED (Note 4) INPUT OPEN * Designate preset value separately in item of “integration preset value”. Must be designated in 4 significant digits. u Automatic 2 range changeover □Automatic 2 range • 2nd range: 0.1 to 15 m/s 2nd range: _ _ _ _ 10.00 changeover converted to flow velocity. Volume unit: □mL, □L, □m3 Time unit: □/s, □/min, □/h, □/d • Changeover hysteresis: 0.0 to 20.0% (with respect to smaller range). Hysteresis: _ _ . _ % 5.0% • Status output: OUTPUT ON (Note 5) □OUTPUT ON OUTPUT OFF □OUTPUT OFF i Automatic forward/reverse changeover □Automatic forward/reverse Must be designated in 4 significant digits. • 2nd range: 0.1 to 15 m/s 2nd range: _ _ _ _ changeover 10.00 converted to flow velocity. Volume unit: □mL, □L, □m3 Time unit: □/s, □/min, □/h, □/d • Changeover hysteresis: 0.0 to 10.0% (with respect to smaller range). Hysteresis: _ _ . _ % 5.0% • Status output: OUTPUT ON (Note 5) □OUTPUT ON OUTPUT OFF □OUTPUT OFF □Flow switch o Flow switch Upper limit: _ _ _ . _ [%] +90.0[%] • Upper limit: -10.0 to 110.1% Lower limit: _ _ _ . _ [%] –02.0[%] (if 110.1% is selected, upper limit is invalid). • Lower limit: -10.1 to 110.0% □OUTPUT ON (if -10.1% is selected, lower limit is invalid). □OUTPUT OFF • Status output: OUTPUT ON (Note 5) OUTPUT OFF !0 Integration switch □Integration switch Set value: • Set value: ___________ –9999999999 to +9999999999 □OUTPUT ON • Status output: □OUTPUT OFF OUTPUT ON (Note 5) OUTPUT OFF * Unit is the same as set value for integration constant. □Alarm output • Alarm selection !1 Alarm output □ALL FUNCTION • Alarm selection □HARDWARE FAULT ALL FUNCTION, □PROCESS FAULT HARDWARE FAULT, PROCESS FAULT • Status output: • Status output: □OUTPUT ON OUTPUT ON (Note 5) □OUTPUT OFF OUTPUT OFF Empty detection INHIBIT □INHIBIT None INHIBIT function □ENABLE ENABLE TAG-NO Blank unless None ________ F-100 Up to 16 alphanumerics designated ________ Flow FORWARD □FORWARD None FORWARD direction □REVERSE REVERSE (Note 4) Status input specifications: No-voltage contact. 1 kΩ or less when closed. 50 kΩ or more when open. (Note 5) Status output specifications: Capacity; 30V DC or less, 0.2A or less, ON voltage; 2V or less 17 FMB1, 2/ FMC Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDS6-70B 价格&库存

很抱歉,暂时无法提供与“EDS6-70B”相匹配的价格&库存,您可以联系我们找货

免费人工找货