STOP VALVE & CONDENSATE CHAMBER
DATA SHEET
In measuring pressures, flow rates or levels, a process piping and a pressure piping to feed pressures from a process tank to a transmitter are required. Fuji's stop valve and condensate chamber are designed to be used with a pressure piping system to provide proper maintenance of transmitters and better measurement accuracy. Both the stop valve and condensate chamber are available in different operating pressure ratings to permit selection according to applications.
FXJ, FXK
SPECIFICATIONS
Stop Valve (Type:FXJ)
Application: The stop valve is used to remove a transmitter from a pressure piping when maintenance of the transmitter is required. It can be readily fitted to the pressure piping. Material of main unit: Materials of other parts: Operating pressure and temperature:
Symbol Material of main unit Materials of Operating other parts pressure
2
Temperature [°C]max.
FCD400 1MPa{10.20kgf/cm } A SUS 403 FCD450 2MPa{20.39kgf/cm2} C SUS 304 2MPa{20.39kgf/cm2} SUS304 D SUS 304 15MPa{153.0kgf/cm2} ASTM A182F11 SUS 403 F 24MPa{244.7kgf/cm2} ASTM A182F22 SUS 403 G 11MPa{112.2kgf/cm2} SF440A H SUS 403 * 28MPa{285.5kgf/cm2} SF440A SUS 403 *J 7MPa{71.38kgf/cm2} SUS304 K SUS 304 Note: Symbols A to K denote the 4th digit of the code.
200 250 250 425 525 360 425 300
Operating pressure and temperature, and material: 2MPa·350°C max., JIS STPG370 {20.39kgf/cm2} 6MPa·400°C max., JIS STPT370 {61.18kgf/cm2} 15MPa·500°C max., ASTM A182 F11 {153.0kgf/cm2} 24MPa·525°C max., ASTM A182 F22 {244.7kgf/cm2} Type of connection: R1/2 Rc1/2 1/2B pipe 1/2B socket 1/2, 1B flange (JIS 10, 16, 20, 30K)
Note: For the arrangement of inlet and outlet, refer to Table given in page 2
Water inlet:
Type of connection:
Inlet Rc1/2 Rc1/2 φ 22.2 socket Outlet Rc1/2 φ 9.6 union φ 22.2 socket Application FXJA, C, D, K FXJA, C, D FXJF, G, J, H
Pressure: 6MPa{61.18kgf/cm2} max. for standard provision Pressure: 15MPa{153.0kgf/cm2} min. for non-standard provision
Ranges of Operating Temperature and Pressure
Mass {weight}:
FXJA 0.5kg FXJC, D 2kg FXJK 3kg FXJF,G,H,J 3.5kg Finish color: Silver (excluding SUS parts) Range of delivery: Stop valve
Condensate Chamber (Type:FXK)
Application: The condensate chamber is used with a differential pressure transmitter when measuring boiler drum level or stream flow rate. It keeps condensation at a fixed level for better measurement accuracy.
EDS8-42h
Date May. 30, 2000
FXJ, FXK
CODE SYMBOLS
Stop Valve
12345678 9
FXJ
3 Material/pressure Material of Materials of main unit other parts FCD400 SUS403 FCD450 SUS304 SUS304 SUS304 ASTMA182F11 SUS403 ASTMA182F22 SUS403 SF440A SUS403 SF440A SUS403 SUS304 SUS304
Description Temperature Connection [°C]max Rc1/2 200 Rc1/2 250 Rc1/2 250 1/2 socket (φ22.2) 425 1/2 socket (φ22.2) 525 1/2 socket (φ22.2) 360 1/2 socket (φ22.2) 425 Rc1/2 300
Operating pressure 1MPa {10.20kgf/cm2} 2MPa {20.39kgf/cm2} 2MPa {20.39kgf/cm2} 15MPa {153.0kgf/cm2} 24MPa {244.7kgf/cm2} 11MPa {112.2kgf/cm2} 28MPa {285.5kgf/cm2} 7MPa {71.38kgf/cm2}
A C D F G *H *J K 10 20 30 Y A Y A
Connection Screw, Rc1/2 Union Socket Treatment None Oil repulsion (SUS304 only) Stainless steel tag plate None Yes
Condensate Chamber
12345678
F XK
3
Description Material, pressure And temperature Operating Temperature End Drum pressure [°C]max plate
Arrangement of the 5th and 6th digits of the code following the symbol in the 4th digit
4th 5th digit digit A 1 B C F G H K L M A 2 C D E H J M N E 3 E 4 6th digit Fig.No. A BC DE F GHJ Fig. 6
1 2 3 4
STPG370 SPHC-P STPT370 SF440A ASTM A182 F11 ASTM A182 F22
2MPa {20.39kgf/cm2} 6MPa {61.18kgf/cm2} 15MPa {153.0kgf/cm2} 24MPa {244.7kgf/cm2}
350 400 500 525
A B C D E F G H J K L M N Z Y A
Type of connection (1) Type of inlet is entered in the 5th digit of the code, and the type of outlet in the 6th digit. (2) Symbols entered in the 5th and 6th digits are referred to Table given below. R1/2 Rc1/2, with union joint (screw type) Rc1/2, with socket (screw type) 1/2B pipe (welded to socket) 1/2B, with sockert (welded to socket) JIS 10K 15A, with flange JIS 16K 15A, with flange JIS 20K 15A, with flange JIS 30K 15A, with flange JIS 10K 25A, with flange JIS 16K 25A, with flange JIS 20K 25A, with flange JIS 30K 25A, with flange Other Stainless steel tag plate None Yes
Fig. 7, 8
Fig. 9, 10
Fig. 11 Fig. 12 Fig. 13, 14 Fig. 15, 16 Fig. 17 Fig. 18
2
OUTLINE DIAGRAM (Unit:mm)
Stop Valve
3
FXJ, FXK
Condensate Chamber
4
5
FXJ, FXK
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
Asterisked (*) items: Non-standard.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng
Instrumentation Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan