FC SERIES PT TYPE ALARM SETTER
DATA SHEET
The FC series PT type alarm setter accepts one or two input signal, compares internal or external setting signal, and outputs alarm contact signals of upper limit or lower limit. Its structure is plug-in style.
PTP
SPECIFICATIONS
INPUT SPECIFICATION
Input signal: Input for monitor 2 points (Max.) Input for external setting 2 points (Max.)
Input type Input signal Voltage 1 to 5V DC Current 4 to 20mA DC 250Ω
Input resistance 1 MΩ or over
ALARM SETTING SPECIFICATION
Internal setting: By built-in trimmer resistor External setting: By external signal
OUTPUT SPECIFICATION
Output signal: 2 points (Max.) Output type: Relay contact output Contact capacity: 24V / 0.5A DC, 100V/ 0.4A AC 200V/ 0.2A AC or less (resistance load)
Response time: Less than 0.2 sec. Dielectric strength: 1500V AC, 1 min. (Input - Output - Power - Ground) Insulation resistance: 500V DC, 100MΩ or over (Input - Output - Power - Ground) Ambient temperature effect: Less than ± 0.15% of full span/10°C Power regulation effect: Less than ± 0.15% of full span
CODE SYMBOLS
12345678 9 10
POWER SUPPLY
Power supply: 24V DC (20 to 30V DC) 24V AC, +13%, –10%,(47 to 63Hz) 100V AC (85 to 132V AC / 47 to 63Hz) 200V AC (187 to 264V AC / 47 to 63Hz) as specified. Power consumption: Approx. 2W (at DC power) Approx. 6VA (at AC power)
PTP 1 2 1 2 A B 1 2 3
1 Input signal 1 to 5V DC 4 to 20mA Output signals 1 point 2 points
Description
Alarm setting system Internal setting External setting Power supply 24V DC / 24V AC (50/60Hz) 100V AC (50/60Hz) 200V AC (50/60Hz) 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 1st alarm specifications Excitation ON (upper limit alarm) Excitation ON (lower limit alarm) Excitation OFF (upper limit alarm) Excitation OFF (lower limit alarm) Non- Excitation ON (upper limit alarm) Non- Excitation ON (lower limit alarm) Non- Excitation OFF (upper limit alarm) Non- Excitation OFF (lower limit alarm) 2nd alarm specifications None (The 5th digit : 1) Excitation ON (upper limit alarm) Excitation ON (lower limit alarm) Excitation OFF (upper limit alarm) Excitation OFF (lower limit alarm) Non- Excitation ON (upper limit alarm) Non- Excitation ON (lower limit alarm) Non- Excitation OFF (upper limit alarm) Non- Excitation OFF (lower limit alarm)
OPERATION CONDITION
Ambient temperature: 0 to 50°C Ambient humidity: Less than 90%RH (no condensation) Outline dimension (HxWxD): 96 x 52 x 130mm Mass: Appox. 300g Housing: Plastic housing (color: black) Mounting method: Panel mounting or DIN rail mounting
CHARACTERISTICS
Accuracy: Less than ± 0.2% of full span Reproducibility: Less than ± 0.1% of full span Hysteresis width: Approx. 0.3% of full span
EDS9-26a
Date Feb. 20, 1996
PTP
FUNCTIONAL DIAGRAM
Internal Setting
31 Comparator 1 11 Monitor input 1 12 21 22 13 Monitor input 2 14 23 24 Setting 2 Power supply circuit 43 Power supply 44 34 Setting 1 Comparator 2 42 41 Output 2 32 Output 1
External setting
31 Comparator 1 11 Monitor input 1 12 21 Setting input 1 22 Comparator 2 13 Monitor input 2 14 23 Setting input 2 24 Power supply circuit 43 Power supply 44 34 42 41 Output 2 32 Output 1
OUTLINE DIAGRAM (Unit: mm)
Terminal screw M4 Main unit Terminal screw M2.5 (for transmission)
74
94
35
Terminal
48 52 100 130 2
Stopper
Panel mounting
DIN rail mounting
2-M4
DIN rail
40 52
Stopper
EXTERNAL CONNECTION DIAGRAM
INPUT 1 INPUT 2
+ 11 12
EXT. SP1
+ 13 14
EXT. SP2
+ 21 22 5 6 31 32
OUTPUT 1
+ 23 24
33 34
41 42
OUTPUT 2
43 44 + POWER
RANGE OF DELIVERY
Main unit and socket
PTP
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng
Instrumentation Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan
很抱歉,暂时无法提供与“EDS9-26A”相匹配的价格&库存,您可以联系我们找货