EDSX10-61J

EDSX10-61J

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX10-61J - MICROJET RECORDER (100mm) - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX10-61J 数据手册
MICROJET RECORDER (100mm) DATA SHEET This recorder can record a maximum of 6 channels of DC voltage, mA, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record measured data in analog trace mode or to print in digital mode at a high speed. This 100mm-wide recorder performs recording clearly in 6 different colors. PHC FEATURES 1. Compact size Compact and lightweight design, 199mm in depth and about 2.1kg in mass{weight}. 2. High quality recording • Ink jet system is used for recording and printing meas-ured data in 6 different colors at a high speed. Operating noise is minimized. • Six continuous traces without pen offset are possible with this compact size of recorder; a unique recording system is used for the first time in the industry. • Scale of each channel is printed on chart paper, elimi- nating the need for scales. 3. Easy setting of input signals DC voltage input (5mV span, 50V max.), 12 kinds of thermocouples (Type B, R, S, K, E, J, T, N, W, L, U, PN) and resistance bulbs (Pt100) can be set for each channel. 4. Digital printing Beside the analog recording of measured data, digital printing is also available (periodic printing, list printing, alarm printing, daily report printing, message printing). • Periodic data printing: Channel No., date, time, unit, chart speed, measured value • List printing: Date, time, unit, recording range, scaling value, alarm set value, chart speed, Tag No. • Alarm printing: Channel No., alarm type, on/off time, output relay No. • Daily report and totalized data printing: Printing of maximum, minimum, average and total of data measured during maximum 24 hours • Message printing : 10 messages, 16-character userentered messages 5. Interactive key operation Fluorescent indicator is used to clearly indicate alphanumeric characters and symbols. Input mode, recording range, alarm value, chart speed, etc., can be set according to the comments indicated by the display and operating keys. No bothersome operation is required. 6. Easy handling • A cartridge type recording device is used for easy replacement. • Allow to draw out the chart paper while recording. • Shortage of ink is detected in early stages and an alarm is given to the operator. • The end of chart paper is detected and indicated on the front panel display. • Shortage of ink and the end of chart paper alarm output is possible. 7. Full variety of functions • Alarm relay output/external control (record start/stop, chart speed change, data printing, message printing). This unit can easily be connected to the recorder by user (option). • Chart paper illumination lamp (option): The result of printing can be checked even in lower light. • Burnout function is provided as a standard. • Various recording: Enlarged/reduced recording, autorange recording, zone recording. • Calculation: Square root extraction, subtraction, engineering unit conversion, logarithm. • Language: Selectable 3 languages in display and printing. • Passcode security is configurable. • Transmission function: RS-485 (option) • The message print and alarm print function are operational, even when the recording mode is off. • All parameters of recording format, daily report, totalize, message and periodic data printing can be printed out. EDSX10-61j Date Nov. 24, 2011 PHC SPECIFICATIONS Input system 3 or 6 continuous recording 6 intermittent recording Thermocouple input...B, R, S, K, E, J, T, N, W, L, U, PN Resistance bulb input...Pt100Ω DC voltage input...50mV, 500mV, 5V, 50V range DC current input...4 to 20mA DC, 10 to 50mA DC (Shunt resistor (option) need to be connected to the terminal) Max. input voltage: • Thermocouple, resistance bulb and DC voltage (50mV, 500mV range) ...±10VDC or less • DC voltage input (5V, 50V range) ...±100VDC or less Input signal setting and change: Setting and change of input signal between thermocouple, resistance bulb and DC voltage (50mV, 500mV, 5V, 50V range) is possible for each channel by the setting pin in the instrument. Setting of recording range: Setting is possible within the reference range by using the keyboard. Burnout function:When thermocouple or resistance bulb input is disconnected, the recording is deflected to 100%. Reference range: Kind Thermocouple B R S K E J T N W L U PN Pt100 Reference range 400 to 1760°C 0 to 1760°C 0 to 1760°C -200 to 1370°C -200 to 800°C -200 to 1100°C -200 to 400°C 0 to 1300°C 0 to 1760°C -200 to 900°C -200 to 400°C 0 to 1300°C to to to to to 600°C +50mV +500mV +5V +50V Reference range 752 to 3200°F 32 to 3200°F 32 to 3200°F -328 to 2498°F -328 to 1472°F -328 to 2012°F -328 to 752°F 32 to 2372°F 32 to 3200°F -328 to 1652°F -328 to 752°F 32 to 2372°F to 1112°F Input points: Input signal: Z fold 15.08m Continuous recording type 5 to 400 mm/h, continuous recording 401 to 1500 mm/h, intermittent recording Intermittent recording type 5 to 1500 mm/h Each can be set in 1 mm/h steps. Recording cycle: Intermitter recording...30 sec/all points Continuous recording...Depends on chart speed. 400 Recording = cycle [sec] Chart speed [mm/h] (not faster than 2 seconds.) Measuring cycle: Up to 3 inputs...160ms 6 inputs...320ms Service life of ink: (Depends on operating conditions) About 6 months for 6 points of linear recording at 20 mm/h of chart speed Chart handling: Tear off without disturbance of recording. Chart length: Chart speeds: Resistance bulb DC voltage -200 -50 -500 -5 -50 -328 Scaling is possible within the range of -32767 to +32767 (decimal point may be put as necessary) Note: N W L U PN Pt100 : NICROSIL-NISIL (IEC584) : side 5% Re, -side 26% Re .W (Hoskins Mfg. Co., + U.S.A.) : +side Fe, -side Cu.Ni alloy (DIN43710) : +side Cu, -side Cu.Ni alloy (DIN43710) : Platinel : DIN IEC751 Recording system Writing system: Ink jet system, 6 colors Chart width: 100mm Recording color: No. 1 channel (orange), No. 2 channel (green), No. 3 channel (purple), No. 4 channel (red), No. 5 channel (black), No. 6 channel (blue) Recording color can be assigned for each channel. 2 Indication: Fluorescent indication (blue-green), 20 characters x 2 lines Characters indicated: 5 x 7 dots, 4.16mm high, 2.25mm wide Contents of indication: (1) Measured value: Temperature...1 digit below decimal point; Voltage...6 digits (including sign and decimal point) Measured value of No.1 channel to No.6 can be indicated simultaneously. (2) Channel No.: 1 digit (1 to 6) (3) Engineering unit: Max. 7 digits (°C, °F, %, Pa, bar, ppm, m3/h, etc.) (4) Tag No....8 characters (5) Time: Year, month, day, hour, minute (6) Status indication: Record ON, chart end, battery alarm, alarm, ink shortage alarm, burnout, carriage failure Configuration: These can be set according to the comments indicated by operating keys as follows, Passcode Main chart speed Sub chart speed Alarm setting Record mode (trend/logging) Recording range Input signal List print request Tag No. Daily report setting Totalize function Communication parameter Date and time setting Ink monitor clear Illumination on/off Message definition Measured value shift Indicating system Writing system: Ink jet system, 6 colors Periodic data printing: Measured value, unit, date, time, time line, chart speed, channel No. List printing: (1) Measured value list (date, time, channel No., measured value, unit) (2) Parameter list (date, time, channel No., recording range, scaling, unit, alarm set value, chart speed, Tag No.) (3) Test pattern (all characters and color patterns) Message printing: 10 m e s s a g e s , 16 - ch a r a c t e r u s e rentered messages Alarm printing: Channel No., alarm type ( H, L, RH, RL), output relay No., on/off time Burnout printing: Burnout channel No. and time Other: Ink short age message, automatic range selection mark, recording start mark, chart speed change mark Note: Printing is not available for more than 401 mm/h (continuous recording), or more than 51 mm/h (intermittent recording). Printing system Performance and characteristics Accuracy and resolution: Performance under reference condit i o n (23± 2° C, 65± 10%RH, power voltage and frequency variation ±1%, warm-up time 30 minutes or more, vertical mounting, free from the effect of external noise) Input Th e r- B moR couple S K E J T N W L U PN Resistance Pt100 bulb DC -50 voltage -500 -5 -50 Indication (digital) Resolution 0.1°C 0.1°C 0.1°C ±(0.15% 0.1°C +1 digit) 0.1°C (without reference 0.1°C junction 0.1°C compen0.1°C sation 0.1°C error) 0.1°C 0.1°C 0.1°C Accuracy ±(0.15% +1 digit) to to to to +50mV ±(0.15% +500mV +1 digit) +5V +50V 0.1°C 10µV 100µV 1mV 10mV Recording Accuracy Resolution Withstand voltage: Input terminal - input terminal...500V AC, 1 minute Power supply terminal - ground... 2000V AC, 1 minute Input terminal - ground...500V AC, 1 minute Power terminal - input terminal...500V AC, 1 minute Between alarm terminals...750V AC, 1 minute ( eakage current 5mA or less, howL ever, if the power supply is 24V DC, Leakage current of “Power supply terminal - ground” is 10mA or less) Reference junction compensation accuracy: K, E, J, T, N, L, U, PN ..... ...... ±0.5°C . (In case of minus input measurement: ±1.2°C) R, S, B, W ............................ ±1°C . (In case of minus input measurement: ±2.4°C) Common mode noise rejection: 120dB at 50, 60Hz ±0.1Hz Series mode noise rejection: 30dB at 50, 60Hz ±0.1Hz Physical data Mounting: Panel (may be inclined up to 30 ° backwards from the vertical.) α=90~60° Indication accuracy, 0.1mm ±0.25% miniof record- mum ing span Two more recorders can be mounted side by side. Material: Case...Steel plate Front door frame...Polycarbonate with glass wool Mass{weight}: Approx. 2.1 kg (without option) Approx. 2.2 kg (with option) Case size: Bezel 144x144mm Depth 199mm Cutout 137x137mm Finish color: Case...Black, Front door frame...Black External terminals:Screw terminal (M4 screw) Power requirement 1) upply voltage 100 to 240V AC products (9digit of S code symbol = “D”) • Power supply voltage: 1 00V (-15%) to 240V (+10%) AC (Free power supply) • Supply frequency: Input resistance: Thermocouple:>10MΩ 50mV range: >10MΩ 500mV range: >100kΩ 5V and 50V range: >1MΩ Chart speed accuracy: ±0.1% (expansion and contraction of paper is not included) Clock accuracy: ±50ppm or less (monthly error; about 2 minutes) Imsulation resistance: 100MΩ or more (between each terminal and earth, at 500V DC) Note: Indication accuracy is in % of reference range. I ndication accuracy of B type TC is ±(0.36% + 1digit) between 400°C to 600°C. I ndication accuracy of all type TC is ±(0.36% + 1digit) between -200°C to -100°C. 50/60Hz both employable • Power consumption: 1 00V AC with all options approximately 26VA 2) upply voltage 24V DC products (9digit of code S symbol = “L ”) • Power supply voltage: 24V (±10%) DC • Power consumption: 2 6.4V DC with all options 26VA or less 3 PHC Operating environment (for devices to operate continuously) Usage environment: ndoor I Temperature limits: 0 to 50°C Humidity limits: 20 to 80%RH, non condensing is required (temperature x humidity
EDSX10-61J 价格&库存

很抱歉,暂时无法提供与“EDSX10-61J”相匹配的价格&库存,您可以联系我们找货

免费人工找货