0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX11-135B

EDSX11-135B

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX11-135B - FC SERIES MANUAL LOADER(CONTINUOUS OUTPUT TYPE) - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX11-135B 数据手册
FC SERIES MANUAL LOADER (CONTINUOUS OUTPUT TYPE) DATA SHEET The FC series Manual Loader carries out remote control in combination with a controller. This product is a manual loader to be used in a process and it excels in the effect of monitoring due to adoption of a color LCD. Besides standard signals of 1 to 5 V DC, input signals from thermocouples and resistance bulbs can be handled at option. PDB3 FEATURES 1. High visibility ensured with color graphic display A color LCD is adopted for graphic display of bar graph and trend screens,etc. 2. Communication function (option) RS-485 (Modbus protocol) are available. 3. Back-up (option) If the loader becomes faulty, influence over the system can be evaded by changing the built-in backup operation unit. 4. Memory card (option) Memory card can save any data, for example process input, manipulation output, WAFER output, etc. Communication RS-485 (Modbus® ) Transmission terminal PV indicator Signal name/terminal No. MV indicator Signal name/terminal name Manual mode output/DO8 (KPV) Process variable input/PV1 (Analog input) External input terminal External input terminal Linearize square root Filter PV compensation signal (KPV)/AO3 Internal input terminal MH ML M Forced opening constants MV HMV (Option) MV External AMV input/PV2 (Analog input) Internal input terminal Manipulation output (voltage) (MV)/AO1 Manipulation output (current) /Mi+1, Mi-1 Forced opening command (EXS)/Di9 Manual mode command (SMV)/Di10 KPV Alarm Upper alarm output (H)/DO9 Lower alarm output (L)/DO10 Fault output (FLT-Do)/FLT Fault FLT lamp EDSX11-135b Date Dec. 24, 2003 PDB3 SPECIFICATIONS 1. Input Signals Performance under reference condition(23 ± 2˚C, 55± 10%RH, Power voltage and frequency variation ± 1%, free from the effect of external noise) unless otherwise specified. 1-1 Analog input signal • Number of inputs 8 inputs • Inpute signal types : DC voltage, thermocouple (option), resistance bulb (option) Two thermocouple inputs or two resistance bulb inputs are selectable. (1) DC voltage • Input range: Selectable among 0 to 5 V DC, 1 to 5 V DC and 0 to 10 V DC Initial set before delivery : 1 to 5 V DC • Input accuracy: ± 0.1% of input span± 1 digit • Scaling (Industrial data conversion) : Settable within a range from -32767 to 32767 4, 3, 2, 1 or 0 digit below decimal point is selectable. Initial set before delivery : 0.00% to 100.00% • Industrial unit: Settable in up to 8 characters Usable characters: Alphabets numerals, symbols such as +, – ,*,etc. • Input accuracy guarantee range: –5% to 105% of input range. • Maximum continuous permissible voltage: ± 35 V • Input resistance: 1 MΩ or more • Influence by ambient temperature: ± 0.1% FS/10°C or less. • Influence by power supply fluctuation: ± 0.1% FS or less. • Isolation : Non-isolated from internal circuit. • In case of current input: Shunt resistor need to be connected to the analog input terminal. (250 Ω shunt resistor is optional item) (2) Thermocouple (option) • Types and measurable ranges: * See Table 2. • Input accuracy: ± 0.2% FS ± 1 digit [Note]B type: ± 5% between 0 to 400˚C S and R type: ± 1%between 0 to 500˚C All type of TC: ± 5% under–100˚C • Reference junction compensation error: ± 1.0°C (provided measurable range is –50°C and higher) [Note]Reference junction compensation resistor is connected at external input terminal in case of thermocouple input is ordered. • Input accuracy guarantee range: –5% to 105% of input range. • Input resistance: 1 MΩ or more • Allowable signal source resistance: 100 Ω or less (Zener barrier connection unallowable) • Influence by signal source resistance: About 0.25 µV/Ω • Influence by ambient temperature: ± 0.2% FS/10°C ± 1°C or less. • Influence by power supply fluctuation: ± 0.2% FS ± 1˚C or less • Burnout detection: Provided • Isolation: Isolated from internal circuit. (3) Resistance bulb (option) • Types and measurable ranges: * See Table 2. • Input accuracy: ± 0.2% FS ± 1 digit • Input accuracy guarantee range: -5% to 105% of input range • Allowable wiring resistance: 10 Ω o r less per wire, provided wiring resistance must be equal among 3 wires (Zener barrier connection unallowable) • Influence by ambient temperature: ± 0.2% FS/10˚C or less. • Influence by power supply fluctuation: ± 0.2% FS or less • Burnout detection: Provided • Isolation: Isolated from internal circuit. [Note] FS: full span. • Sampling period : 100 ms 1-2 Digital input signal • Number of inputs : 10 inputs • Electrical specifications : No-voltage contact or transistor contact ON/0 V, OFF/24 V, ON current/about 8 mA Isolated from the internal circuit by photocoupler. Not isolated between each digital input and output. • Contact rating : 30 V DC, 10 mA or more • Signal judgment : No-voltage contact Contact resistance; 200 Ω or less at ON, 100 kΩ or more at OFF : Transistor contact 1V max at ON., leakage current 100µA max. at OFF 2. Output Signals Performance under reference condition(23 ± 2˚C, 55± 10%RH, Power voltage and frequency variation ± 1%, free from the effect of external noise) unless otherwise specified. 2-1 Analog output signal (1) Control output • Number of outputs : 1 output • Output signal : 4 to 20 mA DC • Output accuracy : ± 0.2% FS • Load resistance : 600 Ω or less 2 • Output accuracy guarantee range : 2 to 22 mA DC • Influence by ambient temperature : ± 0.2% FS/10˚C or less • Influence by power supply fluctuation : ± 0.2% FS or less • Isolation : Non-isolated from internal circuit (2) Auxiliary analog output • Number of outputs: : 4 outputs • Types of signal : Selectable among 0 to 5 V DC, 1 to 5 V DC and 0 to 10 V DC Initial set before delivery: 1 to 5 V DC • Output accuracy : ± 0.1% FS • Load resistance : 15 kΩ or more • Output guarantee range : 1 to 5 VDC : –12.5% to 112.5% : 0 to 5 VDC : 0% to 112.5% : 0 to 10VDC : 0% to 105% • Influence by power supply fluctuation : ± 0.1% FS or less •Isolation : Non-isolated from internal circuit 2-2 Digital output signal • Number of outputs : 10 outputs • Electrical specifications : Transistor open collector 1 V max. at ON, 10 µA max at OFF. Isolated from the internal circuit by photocoupler. Not isolated between each digital input and output. • Output rating : 30 V DC, 100 mA max. (resistive load) 2-3 Fault output signal (terminal symbol FLT) • Number of outputs : 1 output • Electrical specifications : Transistor open collector 1 V max. at ON, 10 µA max at OFF. Isolated from the internal circuit by photocoupler. Not isolated between each digital input and output. • Output rating : 30 V DC, 100 mA max. (resistive load) 3. Display • Display unit 4. Setting and Operation (1) Control output operation method • Operation key : Up key, down key and high-speed key • Operation speed : About 40 s/FS (usual), about 8 s/FS (high speed) (2) Operation mode • Kinds of operation mode : A, M and HM [Note] A : Auto mode (operation according to the remote control signal (voltage input)) M: Manual mode (control output to be manually operated by operator) HM: Hardware Manual mode (operated by back-up loader) • Changeover : Balanceless bumpless changeover [Note] Balanceless bumpless changeover is a method where each setting value is automatically balanced by the manual loader at the time of changeover. (3) Security : Setting of a password • Method : Settable in 4 numerals (within 0000 to • Password ffff) Initial set before delivery: 0000 • Contents of security : Inhibition of parameter setting (4) Other setting items : Settable in up to 8 characters • Tag name Usable characters; alphabes, numerals, symboles such as +, – ,*,etc. 5. Power Supply • Voltage rating : 100 V to 240 V AC/24 V DC • Allowable range : 85 V to 264 V AC/20 V to 30 V DC • Frequency : 47 to 63 Hz • Power consumption : 60 VA or less (100 V to 240 V AC) : 30 W or less (24 V DC) • Power supply output voltage (terminal symbol VP and PC) : 20V to 30V DC, max. 40mA : 16 Colors graphic liquid crystal display, with CFL back light and contrast adjust function. • Contents of display : Menu : Loop panel Bar graph display, digital display, etc. : Trend screen (max. 8 screens) : Alarm and alarm historical screen : Analog input/output and digital input/ output indication screen : WAFER connection screen : Parameter setting screen 3 PDB3 6. General performance and characteristics • Insulation resistance : 500 V DC, 50 MΩ or more. • Dielectric strength : 2,000 V AC for 1 minute between power terminal and ground terminal in case of 100 V to 240 V AC power supply : 500 V AC for 1 minute between power terminal and ground terminal in case of 24 V DC power supply. : 500 V AC for 1 minute between signal communication terminals and ground terminal • Rush current : 60 A or less. (100 V AC to 240 V AC power supply) • Clock : Set and display year, month, day, hour, minute, second accuracy : ± 100 ppm except for time lag shorter than 1 s / power ON / OFF action. • Memory backup : Protection by lithium battery. (expected battery life is about 2 years under room temperature) Parameter and program are stored nonvolatile memory. 7. Operating and storage conditions • Mounting place : Indoor • Operating temperature : 0 to 50˚C : 0 to 40°C in case of multiple mounting ( Temperature change rate : Max. 10˚C / h) • Transport and storage temperature : -20 to 70˚C ( Temprature change rate : Max. 20˚C / h) • Operating humidity : 5 to 90% RH, condensation unallowable • Transport and storage humidity : 5 to 95% RH, condensation unallowable • Operating continuous vibration : 4.9 m/s2 or less • Transport and storage shock : Fall of 60cm max. in packed status 8. Power Failure and restart Function • Permissible duration of momentary power failure : 20 ms at 90V AC (100 V to 240 V AC only) [Note] In case of 24 V DC, system power supply unit (model: PXJ) is recommended to avoid power failure problem. • Behavior at power failure detection : Control stops at detection of power failure. • Power recovery mode : Selectable initial start and continuous start 9. Self-Diagnosis • Control and computation circuit failure : Monitoring with watchdog timer • Input signal failure : Voltage/current input Monitoring of range over : Thermocouple and resistance bulb Monitoring of disconection • Control output signal failure : Monitoring of disconnection by read back check • Behavior at failure : FLT is indicated, FLT lamp lights, FLT output signal turns on, and manipulation output is held. 10. Structure • Enclosure : Plastic (material: PC-ABS) • Finish color : Front frame and enclosure both gray • Flame resistance : UL94V-0 • Protection : Front face; IP54 (display unit and operation key) • External dimensions (W x H x D) : 72 x 144 x 280 mm • Mass : 1.9 kg or less • Mounting method : Flush on indoor panel Vertical mounting as standard Tilted mounting allowed within backward angle 0° to 45°. 90° to 45° For panel cutout dimension, refer to Panel Cutout Dimensions • External terminal : Compression terminal type 11. Backup Function (option) • Method : With backup operation unit • Number of control output : 1 output • Output signal : 4 to 20 mA DC • Indication : Manipulation output indication (mA indication) • Indicator : 21-segment LED • Operation key : Manipulation output up, manipulation output down, loop selection • Operation resolution : 5% • Backup changeover : Changeover has been made by the HM (Hard Manual) switch. However, changeover cannot be made when the backup operation unit is faulty. : In all loops, changeover to the HM mode is blanceless and bumpless. 4 12. Communications (option) 12-1 RS485 interface-1 • Communication behavior : Slave • Communication protocol : Modbus® protocol • Physical specification : EIA RS-485 • Communication method : Half-duplex, bit serial : Start-stop synchronizing • Connection form : Multi-drop • Communication speed : 19.2 kbps • Communication distance : Max. 500 m in total • Number of connectable units : Max. 31 units : Fixed to 8 bits • Data length : Odd / Even / None • Parity : 1 or 2 • Stop bit : Isolated from internal circuit • Isolation : 100 Ω (optional item) • Terminator • Communication items : Parameters and process value. • RS232C / RS485 signal converter (optional item) : Code symbol: PDZT0001 14. Standards under Conformity (1) General safety : IEC 1010-1 (1990) EN 61010-1 (1993) (2) EMC : Emission EN 50081-2 (1994) Immunity EN 50082-2 (1995) 13. Memory Card Interface (option) • Specification : Compact Flash® (Based on CFA) • Compatible memory card : 5 V flash memory card Capacity 4, 20 and 32 MB : Process data logging (32 points or less) • Application • Saving period : 1s to 2h • Data storage capacity Memory card capacity 4MB 20MB 32MB Data storge about 180 thousand data about 900 thousand data about 1.35 million data [Note] The data of max. 16 points (4 screens) can be storaged at storage time as 1 s. • Format method : Dependent on this manual loader • Data readout : Readout by PC using PCMCIA card slot • Recommended memory card : Made by Sandisk corporation Sandisk CompactFlash memory card is standardized and on the market. 5 PDB3 Table 1 List of WAFERS Kinds Outline 8 Outputs digital data as word data to an external expansion I/O. Bit slicing Slices the digital data acquired as 1 word data from an external expansion I/O into each bit. 1 Encoder Encodes an input signal into a binary code. 1 Sawtooth wave generator Generates a sawtooth wave with a slope entered for each cycle time. 5 BCD Converts BCD data into binary data and binary data into BCD data. Logical operation Carries out AND,OR,NOT,XOR 6 and a combination of these logical operations. Carries out a combination of Arithmetic operation 8 addition,subtraction,multiplication and division. Carries out temperature and Temperature/pressure 1 pressure compensation through use compensation of differential pressure,compensated pressure,proper temperature. Linearize 7 Carries out segmented-line approximation with 15-segmentedline function. 1 Flip-flop RS flip-flop. Adds the change of input at each 1 Pulse width integration basic cycle to the previous integration value. Selector Compares two input values,and 1 provides High output(Large one), Low output(Small one),and result of judgement on large/small. Selects input or output via a switch 1 Changeover function.Analog hold circuit also provided. Outputs on-delay,off-delay timer 1 Timer signal via start of input signal according to timer setting. Carries out absolute value processing 1 Absolute value/sign on input and outputs the result.Also inversion judges the sign(Positive,negative)of input value and outputs the result. Extracts square root of input value 1 Square root extraction and outputs the result.Low input cutoff function equipped. Carries out lead/lag operation on the 3 Lead,lag input and outputs the results. Used as analog filter function and for various compensations. Limits the input within the range of 1 Limiter high/low limit settings,and outputs the result.Also outputs high/low limit alarm signal. Outputs signal which changes...in 2 Ramp function ramp from toward target value at the set full scale time.There are two of these wafers...in minute unit and hour unit. Carries out sequential integration on 1 Analog averaging input data,calculates the average value at each averaging time, and otuputs the result. Integrates the value obtained by 1 Analog integration multiplying the input data by a proportional constant,and outputs the result. Outputs a pulse at the set time 1 Pulse generation interval. Adds dead band compensation to 1 Dead band the input and outputs the result. WAFER name Bit concatevate WAFER name Pulse No.counter Pulse No.output Kinds Outline 1 Detects rise of pulse and counts the number of pulses. Integrates the input signal and 1 converts it to number of pulses for output. Decodes 2-bit pure binary input and 1 outputs it to 4 terminals. Calculates ranning average of input 2 data and outputs the result. Holds the input value according to 1 sample signal(0/1)and continues the output. Usable for dead time compensation 6 control etc.Data sampling can be done in 1 sec or 1 min units. Outputs ON-OFF signal with 1 hysteresis. Compares the input and set value 1 and outputs the judgment result. 1 Performs output processing in time proportional PID control. Decoder Running average Sample & hold Dead time ON-OFF Alarm Palse width modurator A variety of applications are possible through combination of WAFERS. 6 Table 2 List of Thermocouple and Resistance Bulb Measurable range Input signal Thermocouple J J K K K R B T T E E S N U WRe5-26 PL2 Resistance bulb Pt100 00 Input type code Input range code Measurable range˚C 01 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00 01 02 03 04 05 06 07 0.0~400.0 0.0~800.0 0.0~400.0 0.0~800.0 0.0~1200.0 0.0~1600.0 0.0~1800.0 -200.0~200.0 -150.0~400.0 0.0~800.0 -200.0~800.0 0.0~1600.0 0.0~1300.0 -200.0~400.0 0.0~2300.0 0.0~1300.0 0.0~150.0 0.0~300.0 0.0~500.0 0.0~600.0 -50.0~100.0 -100.0~200.0 -200.0~600.0 -200.0~850.0 SCOPE OF DELIVERY Manual loader, panel mounting bracket, instruction manual (depend on code symbols) Optional Items Item Terminator for communication (100 Ω) Shunt resistor (250 Ω) Communication cable (Note1) For compression terminal, PDZK4xx1 from PD* to PD* For compression terminal, PDZK5xx1 from PD* to PLC For compression terminal, PDZK6xx1 from PD* to PC Communication converter PDZT0001 RS232C / RS485 signal converter Manual Loader Instruction Manual in book form (in English) Instruction Manual on CD-ROM (in English) Mounting bracket PDZA1001 PDZQ2001 Instruction manual on CD-ROM Improved mounting bracket (Note 1) These cables are used for Modbus. Length needs to be specified. 1 1 PDZX3B01 Instruction manual in book form 1 1 With compression terminal at both ends With M3.5 solderless terminal on PLC side 9-pin connector on PC side 1 1 1 PDZS2001 For compression terminal 1 Type PDZR2001 Specificatio For compression terminal Available unit 1 Block diagram of electrical isolation Solid line shows isolation from the other units or circuits. Power supply Power supply unit DI / DO unit Ground Ground DO1 to DO10 DI1 to DI10 PV1 TC or RTD input unit TC or RTD input unit AI / AO unit AI1 to AI6 MI1 AO1 to AO4 PV2 RS485 (Modbus) Communication unit 7 PDB3 CODE SYMBOLS 1 2 3 4 5 6 7 8 9 10111213 1415 PDB 3 1- YY 1 2 A C D A B A Y A D Description Number of control loops 1 loop (1 control output) External terminal Compression terminal Input signal 1 to 5 V DC Thermocouple Resistance bulb Pt100 Note 1 Note 2 Note 2 Power supply voltage 100V to 240V AC (Usable range 85V to 264V AC) 50 / 60Hz 24V DC (Usable range 20 to 30V DC) Operation mode Auto-Manual changeable type Backup operation unit Without For 1 control output, 100 to 240 V AC For 1 control output, 24 V DC Communicatioin / Memory card interface (Slave) (Master) (memory card interface) Note 3 Note 4 Without Without Without Without Without With RS485 Without Without Note 5 RS485 Without With Note 5 Y D Instruction manual Without With Instruction manual on CD-ROM (in Japanese and English) Y M C U Note 1) For current input, a shunt resistor is used for conversion into voltage. Shunt resistor is optional item. Note 2) Thermocouple and resistance bulb input are opitons. Allowable up to 2 points. Note 3) Communication cable and terminator are optional items. Note 4) Recommended maker: Sandisk corporation. Note 5) Slave interface is Modbus protocol. Note 6) Input signal and measurable range initial set before delibvery is as follows. For specification of voltage input, scale is 0.00 to 100.00% For specification of thermocouple, K, 0.0 to 400.0˚C. For specification of resistance bulb is 0.0 to 150.0˚C. 8 OUTLINE DIAGRAM (Unit : mm) 67.5 Panel thickness 8mm or less Panel Terminal cover Mounting bracket 20 72 21.6 Mounting bracket 280 100MIN. 250 or more Note) The distance between other instruments and low end of PDB shall be more than 100mm. MOUNTING BRACKET 50 16 160 205 PANEL CUTOUT DIMENSIONS For mounting one unit 250 or more For mounting multiple "n" units 137.5 144 Number of +1 0 138 0 +1 68 +0.7 0 (72.2n-4) +1 0 138 units n 2 9 PDB3 EXTERNAL CONNECTION DIAGRAM Voltage input 24 V external Power supply (+) (–) RS-485 (Modbus) (+) (–) (COM) 24 V Power supply for DIO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 AI1 SC AI2 AI3 SC AI4 AI5 SC AI6 SC VP PC DI9 DI10 DO9 DO10 MOD+ MODCOM VPD PCD PCD 22 MI+2 23 MI-2 24 MI+3 25 MI-3 26 MI+4 27 MI-4 28 DO6 29 DO7 30 DO8 31 DIO-COM VPD 32 DI6 33 DI7 34 DIO-COM 35 DI8 36 OPT+ 37 OPT38 COM (+) I+2 b 39 Rcj Process Io2 A 40 variable 41 Rcj2 (–) input 2 B 42 I-2 Voltage Thermo- Resistance bulb input couple input input Manipulation output VPD PCD (+) Process variable input 1 Rcj (–) b A B 43 MI+1 44 MI-1 45 AO1 46 SC 47 AO2 48 AO3 49 SC 50 AO4 51 FLT 52 DO1 53 DO2 54 DO3 55 DO4 56 DO5 57 DI1 58 DIO-COM 59 DI2 60 DI3 61 DIO-COM 62 DI4 63 DI5 64 I+1 65 Io1 66 Rcj1 I-1 67 PCD Voltage Thermo- Resistance bulb input couple input input G N/– L/+ ~ – + Power source 100 to 240V AC Power source 24V DC INPUT/OUTPUT TERMINAL FUNCTION (when preset WAFER) Input signal name PV input External AMV input Universal analog input Universal analog input Analog Universal analog input Universal analog input Universal analog input Universal analog input Universal digital input Universal digital input Universal digital input Universal digital input Universal digital input Digital Universal digital input Universal digital input Universal digital input Forced opening command Manual mode command AI3 AI4 AI5 AI6 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI10 Input terminal I+1,I-1 I+2,I-2 AI1 AI2 Output signal name Manipulation output / Voltage (MV) Universal analog output PV compensation signal (KPV) Universal analog output Output terminal AO1 AO2 AO3 AO4 Manipulation output / Current (MI) MI+1,MI-1 Don't use Don't use Don't use Universal digital output Universal digital output Universal digital output Universal digital output Universal digital output Universal digital output Universal digital output Manual mode output (M) Upper alarm output (H) Lower alame output (L) Fault output (FLT-DO) Don't use Don't use MI+2,MI-2 MI+3,MI-3 MI+4,MI-4 DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 DO9 DO10 FLT OPT+ OPT- 10 11 PDB3 [Note] Windows is the registered trade mark of Microsoft corporation. [Note] Modbus is the registered trade mark of Gould Modicon. [Note] Compact Flash is the registered trade mark of Sandisk corporation. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDSX11-135B 价格&库存

很抱歉,暂时无法提供与“EDSX11-135B”相匹配的价格&库存,您可以联系我们找货

免费人工找货