0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX3-113C

EDSX3-113C

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX3-113C - IN-SITU ZIRCONIA OXYGEN ANALYZER - Fuji Electric

  • 数据手册
  • 价格&库存
EDSX3-113C 数据手册
IN-SITU ZIRCONIA OXYGEN ANALYZER ZFK, ZRM DATA SHEET This oxygen analyzer is used to continuously measure oxygen concentration in combustible exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control. The detector (ZFK) used with the analyzer is directly inserted into the objects measured, eliminating the need for a sampling device and provides quick response. The converter (ZRM) features automatic calibration and blowdown functions. The adoption of liquid crystal display facilitates operation and setting in interactive mode. Besides the general-use type detector, corrosion resisting type and high temperature type are available for selection according to applications. General-use detector High-temperature detector FEATURES 1. Output range easily set Output range can be easily set in 0.5% increments within the scope of 2 to 50%. When oxygen decreases, incomplete combustion level appears on the display (rich mode; output voltage of oxygen detector), instead of oxygen concentration. 2. Automatic calibration/blowdown function Automatic calibration and manual/auto blowdown functions are provided as standard functions. An external solenoid valve is required. 3. Easily operated in interactive mode Interactive mode is adopted to the liquid crystal display for operation and parameter setting, facilitating use even for beginners. 4. Combustion efficiency display function Combustion efficiency calculated from oxygen concentration and temperature of exhaust gas can be displayed as an optional function, which is useful to improve combustion efficiency. 5. Sampling device is unnecessary Gas sampling devices such as a gas aspirator, a dehumidifier, etc. are unnecessary because of use of directinsertion type detector. The adoption of a flow guide tube utilizing the flow of the measured gas assures quick response (less than 7sec). 6. Selection of detector type according to applications Besides the general-use type detector used under temperatures of less than 600°C, a corrosion-proof detector for measuring incinerator exhaust gas, and a high temperature type detector using heat insulator for the ejector and insertion tube, capable of measuring temperatures up to 1590° C, are available for selection according to applications. Converter SPECIFICATIONS General Measuring object: Oxygen contained in noncombustible gas Measuring principle: Direct-insertion zirconia system Measuring range: 0 to 2 ……50 vol% O2 freely settable (in 0.5% steps) Repeatability: Within ± 0.5% of max. output signal Linearity: ± 2% of full scale Response time: Within 7sec for 90% response (from calibration gas inlet) Power supply: 100, 115, 220 or 230V AC, 50/60Hz Power consumption: (approx.) 15 + 50VA (at steady state of general-use detector) 15 + 200VA (at start of general-use detector) Warmup time: Approx. 15min Oxygen detector (ZFK2,5), ejector (ZTA) Measuring detector: For general-use: ZFK2 For corrosive gas: ZFK5 EDSX3-113c Date Nov. 30, 2001 ZFK, ZRM Measured gas temperature: Flow guide tube system; –20 to +600°C (for general-use, corrosive gas) Ejector system; –20 to +1590 ° C (for high-temperature gas) –20 to +800°C (for general-use) Measured gas pressure: –3 to +3kPa (–306 to +306mmH2O) Flow guide tube: With or without blow-down nozzle Flange; JIS5K 65A FF (JIS5K-80AFF for high particulate gas) Insertion length; 0.3, 0.5, 0.75, 1m (0.8m for high particulate gas) Ejector (general-use): Probe for guiding measured gas to detector Flange; JIS10K 65A RF Insertion length; 0.5, 0.75, 1, 1.5m (according to customer's specification) Ambient temperature: –20 to +60°C for cable section –5 to +100°C for ejector section 125°C or less at detector flange surface with power applied Structure: Dust/rain-proof structure(IEC IP55 equivalent) Filter: Alumina(filtering accuracy 50 µm) and quartz paper Main materials of gas-contacting parts: General-use detector; Zirconia, SUS316, platinum Anticorrosive detector; Zirconia, titanium, platinum Flow guide tube; SUS304 or SUS316 Ejector (general use);SUS316, SUS304 Ejector; (for high temperature) SiC, SUS316, SUS304 Calibration gas inlet: SUS316 Reference air inlet (option): Rc1/8 or NPT1/8 Detector mounting: Horizontal plane ± 45 ° , ambient surrounding air should be clean. Outer dimensions: (L x max. dia.) 210mm x 100mm (detector) Mass (approx.) {weight}: Detector; 1.6kg Ejector; 15kg (insertion length 1m) Flow guide tube (general-use, 1m); 5kg Finish color: Silver and SUS metallic color Ejector air inlet flow rate: 5 to 10r/min Blowdown air inlet pressure: 200 to 300kPa {2 to 3 kgf/cm2} Ejector exhaust gas processing: Within furnace, returned to flue Heater temperature drop alarm output (ejector): Alarm output when below 100 °C Mechanical thermostat N.O. (1a) contact, 200V AC, 2A Oxygen converter (ZRM) Measuring range: 0 to 2 ……50 vol% O2 freely settable (in 0.5% O2 steps) ± 0.5% of full scale ± 1.0% of full scale Oxygen concentration; 3-digit LED Operation/setting display: 16-digit, 2-line LCD Mode display: 3pcs LED Oxygen concentration output signal: 4 to 20mA DC (allowable load resistance: 500 Ω or less) or 0 to 1V (output resistance: 100 Ω or less) Isolated output, linear Contact output signal: (1) Contact specification; 4 points, N.O. (1a), 250V AC, 2A (2) Contact function; • Under maintenance • Under blowdown • Span calibrating gas • Zero calibration gas Following functions freely selected • High limit alarm • Low limit alarm • High/low limit alarm • Fault (abnormal) Contact input signal: Auto. calibration start (auto. calibration starts when contact closes) Calibration disable (calibration disabled when contact closes) Contact specification; isolated, ON at 1kΩ or less Calibration method: (a) Manual calibration with key operation (b) Auto. calibration (standard function) Calibration cycle; 00 day 00 hour to 90 days 60 hours Calibration gas: • Range settings Zero gas; 0.010 to 50.000% O2 Span gas: 8.000 to 23.000% O2 • Recommended calibration gas concentration Zero gas; 0.25 to 2.0% O2 Span gas; 20.6 to 21.0% O2 (oxygen concentration in the air) Blowdown: A function for blowing out with compressed air dust that has deposited in the flow guide tube. Blowdown can be performed for a predetermined time and at predetermined intervals. Blowdown cycle; 00 hour 00 minute to 99 hours 60 minutes Blowdown time; 0 minute 00 second to 9 minutes 60 seconds Output signal hold: Output signal is held during calibration and blowdown. The hold function can also be released. Transmission function (option): RS-485 Transmission distance; Max. 500m total Number of units connected; Max. 8 units Half-duplex bit serial transmission, startstop synchronization. Repeatability: Linearity: Indication: 2 Remark: When connecting via an RS232C interface, a RS232 ↔ RS 485 converter should be used. Combustion efficiency display (option): This function calculates and displays combustion efficiency from oxygen concentration and measured gas temperature. Thermocouple (K or R) is required for temperature measurement. Rich mode display: When the detector output voltage exceeds 200mV (0.0023%O 2 ), the rich mode (fuel rich) is indicated in LCD where the LED showing the detector output voltage flickers. Self-diagnosis function: Provided for detector temperature fault, zero calibration fault, span calibration fault, calibration disable, and detector output fault. Ambient temperature: –10 to +50°C Ambient humidity: 90% RH or less Power supply: 90 to 220 or 230 V AC, 50/60Hz Construction: Dust-proof, rainproof construction (corresponding to IP53 of IEC) Material: Steel Outer dimensions (H x W x D): 220 X 193 X 89mm Mass {weight}: Approx. 3.5kg (excluding cable and detector) Finish color: Munsell 2.5Y8.4/1.2 Mounting method: Mounted flush on panel or on pipe Electrical Safety: Overvoltage category ; II power supply input ; I relay interfaces (IEC1010-1) External overcurrent protective device ; 10A Equipment interfaces are safety separated (SELV) The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TZ734575. The applicable standards used to demonstrate compliance are : EN 55011 : 1992 CLASSA Conducted and Radiated emissions EN 50082-1 : 1992 Radiated immunity, ESD and FBT ZFK, ZRM 3 ZFK, ZRM CODE SYMBOLS (Detector) 45678 9 10 11 12 13 14 (Ejector) 12345678 ZFK 2 5 R 1 2 1 3 5 4 Description Application General use For corrosive gas (refuse incinerator) Kinds Standard Cal. gas inlet For φ6mm tube For φ1/4 inch tube Power supply 100/115VAC 50/60Hz 200/220VAC 50/60Hz 230VAC 50/60Hz (CE-marking approved) Flow guide tube flange application None SUS304 general use SUS304 general use SUS304 general use SUS304 general use SUS316 for corrosive gas SUS316 for corrosive gas SUS316 for corrosive gas SUS316 for corrosive gas SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate with cover SUS316 for high particulate with cover SUS316 for high particulate with cover SUS316 for high particulate with cover Others Y A Y A B Z Protection cover Without With Reference air inlet Non Rc1/8 NPT1/8 Non-standard spec. Other non-standard items length 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm ZTA 1 2 1 1 Description Measured gas temperature For high temperatures (+1590°C max.) General-use (+800°C max.) B C D E 1 3 5 Insertion length [mm] 500 750 1000 1500 Power supply 100V/115V AC 50/60Hz 200V/220V AC 50/60Hz 230VAC 50/60Hz 0Y0 5A3 5A5 5A7 5A1 5B3 5B5 5B7 5B1 5C3 5C5 5C7 5C1 6D3 6D5 6D7 6D1 6E3 6E5 6E7 6E1 ZZZ (Converter) 12345678 9 Z RM1 B E Y A B C 11 Output signal 4 to 20mA DC 0 to 1V DC Description Optional functions None Serial communication (RS-485) Combustion efficiency display Transmission function + Combustion efficiency display 1 5 1 2 Power supply 90 to 220V AC 50/60Hz 230VAC 50/60Hz (CE marking approved) Mounting method Panel mounting Pipe mounting Note: Specify the detector type. (ZFK 2 or 5, R-type or K-type thermocouple) (Exclusive-special cable) 12345678 9 Z R ZM M R YA YB YC YD YE YF YG YH YJ YK YL YM AA BB CC DD 1- Description Connectable devices For ZRM Types For R thermocouple Conduit length None None None None None None None None None None None None 6m 10m 15m 20m 0 1 2 Cable length 6m 10m 15m 20m 30m 40m 50m 60m 70m 80m 90m 100m 6m 10m 15m 20m ( Replacement Detector element) 45678 9 10 11 12 13 ZFK 2 5 4 0Y0YY Description Application General use (TC516041) For corrosive gas (refer to incinerator) (TC516042) R 6 7 1 3 5 Kinds Standard Cal. gas inlet Polypropylene joint for φ6 tube Brass joint for φ1/4 inch tube Power supply 100/115VAC 50/60Hz 200/220VAC 50/60Hz 230VAC 50/60Hz Cable end treatment None One side (detector side) Both sides Note: For connection between detector and converter, the conduit to be used should be rainproof flexible type. 4 CONFIGURATION Flow guide tube system Rc1/4 (upper side blow port should be selected) Blow-down, 200 to 300kPa {2 to 3kgf/cm2} Solenoid valve (not supplied) Reduction valve (unnecessary when supply air pressure is 200 to 300kPa {2 to 3kgf/cm2} Supply air Rainproof cover Flow guide tube 15ASGP tube equivalent (not supplied) or 10/ 8 PTFE pipe or copper pipe 15ASGP tube equivalent (not supplied) Detector ZFK2 ZFK5 Gas temperature. 600°C max. 12 3 4 5 6 Bule Rainproof flexible conduit. 20m max. AC power supply Sample gas outlet Red Yellow Black White White 4-core cable 2-core cable Gas temperature. 600°C max. Analog output Auxiliary input Converter (ZRM) Zirconia Thermocouple Maintenance Blow-down signal signal contact contact Heater 1 Flow guide tube for high particulate 2 3 4 5 6 7 8 9 10 11 12 13 14 4 to 20mA DC (0 to 1V) 6mm or 4 inch tube for calibration gas (not supplied) Blue Yellow Red White Black White Cell/thermocouple output Heater power supply Sample gas outlet Serial communication Contact input NC 15 16 17 18 19 20 21 22 23 24 Calibrating gas contact SG 25 FG 26 AC power supply N 27 L 28 PE Gas temperature. 600°C max. Flow guide for high particulate with cover RS-485 Reduction valve (ZBD6) AC power supply AC power supply Joint Solenoid valve (not supplied) Standrad gas for zero point (ZBM) Flowmeter (ZBD4) (1 to 1.5R/min) *2 Ref. air to Detector Reduction valve (unnecessary when supply air pressure is 50 to 100kPa {0.5 to 1kgf/cm2} *1 Air supply Reduction vale (ZBD6) *1 Standard gas for span point (ZBM) (0.2 to 0.5R/min) Solenoid valve (not supplied) Note *1 Sandard gas or instrumentation air can be used in plase of span gas. *2 Instrument quality air or bottled air is available as reference air instead of ambient air. 5 ZFK, ZRM Ejector system Ejector (ZTA) Flowmeter (ZBD) Ejector (5 to 10R/min) Joint Reduction valve (unnecessary when supply air pressure is 200 to 300kPa {2 to 3kgf/cm2} ) Supply air Gas temperature. 1590°C max. 1 2 4 5 Power supply Heater temperature drop Alarm Copper pipe 6/ 4mm Solenoid valve (not supplied) Copper pipe 10/ 8mm Copper pipe 10/ 6mm Detector (ZFK2) 12 3 4 5 6 Bule Rainproof flexible conduit. Red Yellow Black White White 4-core cable 2-core cable AC power supply Converter (ZRM) Analog output Auxiliary input Zirconia Thermocouple Maintenance Blow-down signal signal contact contact Heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4 to 20mA DC (0 to 1V) Blue Yellow Red White Black White Cell / thermocouple output Heater power supply Serial communication 6mm or 4 inch tube for calibration gas (not supplied) Contact input NC Calibrating gas contact SG 22 23 24 25 FG 26 AC power supply N 27 L 28 PE 15 16 17 18 19 20 21 AC power supply RS-485 Reduction vale (ZBD6) Standrad gas for zero point (ZBM) Flowmeter (ZBD4) *2 Ref. air Reduction valve (unnecessary when supply air pressure is 50 to 100kPa {0.5 to 1kgf/cm2} *1 Air supply Reduction vale (ZBD6) *1 Standard gas for span point (ZBM) AC power supply (1 to 1.5R/min) joint Solenoid valve (not supplied) to Detector (0.2 to 0.5R/min) Solenoid valve (not supplied) Note: *1 Standard gas or instrumentation air can be used in place of span gas. *2 Instrument quality air or bottled air is available as reference air instead of ambient air. 6 SCOPE OF DELIVERY Detector: Detector main unit x 1, Viton O ring x 2, mounting screw (M5mm x 16) x 6, thermal sticker x 1, flow guide tube (as specified) x 1, ceramic filter x 1, rainproof cover (as specified) x 1 Converter: Converter main unit x 1, mounting bracket set, (according to specification) x 1 Accessories (AC250V 500mA T fuse x 2, AC250V 3.15A T fuse x 2) Ejector: Ejector main unit x 1, insertion tube x 1, M16mm nut, and washer x 4, packing x 1 Items to be prepared separately: (1) Standard gas for calibration Type ZBM NSH4-01 (up to 5% O2 range) Type ZBM NSJ4-01 (over 5% O2 range) (2) Reduction valve for standard gas (type ZBD61003) (3) Flowmeter Type; ZBD42203, 0.2 to 2r/min (for calibrating gas) Type; ZBD42403, 1 to 10r/min (for ejector) CAUTIONS • If combustible gas (CO, H2 etc.) exists in the measured gas, error will occur due to burning at the sensor section. The inclusion of corrosive gas (Si vapor, alkaline metal, P, Pb etc.) will shorten the life of the sensor. • When the measured gas temperature is high (+300°C or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value +125°C). The flow guide should be attached in the direction in which the gas flow to the detector decreases. • When much dust is included in the gas, the flow guide tube should be attached at an inclination so that the flow goes from below to above. And the flow guide should be attached in the direction in which the gas flow to the detector decreases. • In the case of a refuse incinerator, automatic blow down of the flow guide should not be performed (to prevent corrosion of the flow guide tube due to drainage). Blowdown should be performed manually when change in the indication has become very little with the furnace stopped. DEVICE CONFIGURATION The device to be combined differ according to the conditions of the gas to be measured. Select the devices to be combined with reference to the following table. Measured gas Application General-use (boiler) Temperature Gas Flow 600°C or less DUST Protection Note cover Fuel; gas, oil Fuel: coal with blow down For corrosive 600°C or gas (refuse less incinerator) Less than 25g/Nm3 Less than 25g/Nm3 General-use (boiler) 800°C or less 1590°C or less Less than 1m/s Less than 1m/s Less than 1g/Nm3 — Less than 1g/Nm3 no yes — 5 to 20m/s Less than 1g/Nm3 Less than 10g/Nm3 — — Included low moisture ZFK5R Included low moisture ZFK5R with blow down Included low moisture ZFK5R with blow down Included high moisture ZFK5R with blow down SUS316 tube with blow down SIC tube with blow down ZFK2R 4-OYO ZRM ZTA1 ZFK2R 4-OYO ZRM ZTA2 4- 6 E ZRM — 4- 6 D ZRM — 4- 5 B 4- 5 C ZRM ZRM — — Device configuration Detector type ZFK2R ZFK2R 4- 5 A 4- 5 C Converter Ejector type type ZRM ZRM — — 5 to 20m/s Less than 0.2g/mm3 — Less than 10g/Nm3 — Note (1) Dust volume is approximate value. (2) Instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet. 7 ZFK, ZRM OUTLINE DIAGRAM (Unit:mm) Detector (ZFK2) 80 Proof cover (to order) Approx. 130 Approx. 118 5 Approx. 65 67 45.4 36 26 Filter EXTERNAL CONNECTION DIAGRAM Heater Thermocouple Element output 85 A 60 ° Approx. 25 1 3 2 4 Black / White/ red / White/ 2-core wire 5 6 yellow / blue 4-core wire 6- 6 Ref. air inlet (to order) NPT1/8 or Rc1/8 Exclusive-special cable Exclusive cable gland Calibration gas inlet (to order) SUS316 for 6/ 4 PTEF tube or 1/4 inch tube. Flow guide tube 155 12 Approx. L Approx. 20 130 67 Gas inlet 34 ZFK2R 4-5A3 5 7 1 Gas outlet 6-M5 detector side Cord 11th Oxygen detector L (m) 3 0.3 5 0.5 3.3 7 1 Z L= (to order) 8–15 MTG. holes 0.75 1.0 4.1 4.8 MASS 2.7 Approx.(kg) Flow guide tube (with blow-down nozzle) 18 3 Approx. L 155 Approx. 20 130 67 60.5 67 Gas inlet 6-M5 detector side 20 ZFK2R 4-5C3 5 7 1 Gas outlet Oxygen detector Cord 11th L (m) 3 0.3 5 7 1 Z L= (to order) Blow down air inlet Select an upper port to avoid the condensation in the piping 8–15 MTG. holes 4-Rc1/4 with plug int.thd. 0.5 0.75 1.0 3.8 4.8 5.7 Mass 3.0 Approx.(kg) 8 Flow guide tube (for high particulate) 14 5 4 - Rc 1/4 with plug int thd. 180 Blow down air inlet Select an upper port to avoid the condensation in the piping 8 - 19 MTG. hole 67 29. 5 Flange: JIS 5K80A FF ZFK MTG. position Packing 185 ZFK2R 50 4-6D3 5 7 1 Gas outlet 800 30 Cord 11th L (m) 3 0.3 5 7 1 Z L= (to order) 0.5 0.75 1.0 5.6 7.0 8.3 Mass 4.5 Approx.(kg) Gas flow Tube (50A SCH40) Flow guide tube (for high particulate with cover) 180 14 5 4 - Rc 1/4 with plug int thd. Blow down air inlet Select an upper port to avoid the condensation in the piping 8 - 19 MTG. holes 67 29 .5 Flange: JIS 5K80A FF ZFK MTG. position Packing 50 (175) ZFK2R Gas outlet (790) 800 4-6E3 5 7 1 30 Cord 11th L (m) 3 0.3 5 7 1 Z 0.5 0.75 1.0 L= 9.0 11.4 13.6 (to order) Gas flow Mass 7.1 Approx.(kg) Protection tube (65A SCH40) (38) Tube (50A SCH40) 9 ZFK, ZRM Detector (ZFK5) 80 Proof cover (to order) Approx. 130 Approx. 118 5 Approx. 65 67 45.4 36 26 Filter EXTERNAL CONNECTION DIAGRAM Heater Thermocouple Element output 60 ° Approx. 35 1 3 2 4 Black / White/ red / White/ 2-core wire 5 6 yellow / blue 4-core wire Ref. air inlet (to order) NPT1/8 or Rc1/8 Exclusive-special cable 6- 6 Exclusive cable gland Calibration gas inlet (to order) SUS316 for 6/ 4 PTEF tube or 1/4 inch tube. Flow guide tube 155 12 3 67 Gas inlet 67 60.5 Approx. L Approx. 40 130 ZFK5R 4-5B3 5 7 1 Gas outlet 6-M5 detector side Cord 11th Oxygen detector L (m) 3 0.3 5 7 1 1.0 7.6 Z L= (to order) 8- 15 MTG. holes 0.5 0.75 4.5 6.1 MASS 3.3 Approx.(kg) Flow guide tube (with blow - down nozzle) 155 18 3 Approx. L Approx. 20 130 67 Gas inlet 60.5 67 6-M5 detector side ZFK5R 4-5C3 5 7 1 Gas outlet Blow down air inlet Oxygen detector Cord 11th L (m) 3 0.3 5 7 1 1.0 7.4 L= (to order) Z Select an upper port to avoid the condensation in the piping 4- Rc 1/4 0.5 0.75 4.2 5.7 8- 15 MTG. holes with plug int. thd. MASS 3.3 Approx.(kg) 10 Flow guide tube (for high particulate) 14 4 - Rc 1/4 with plug int thd. 180 5 Blow down air inlet Select an upper port to avoid the condensation in the piping 8 - 19 MTG. hole 67 29. Flange: JIS 5K80A FF 5 ZFK MTG. position Packing 185 ZFK5R 50 4-6D3 5 7 1 Gas outlet 800 30 Cord 11th L (m) 3 0.3 5 7 1 Z L= (to order) 0.5 0.75 1.0 5.6 7.0 8.3 MASS 4.5 Approx.(kg) Gas flow Tube (50A SCH40) Flow guide tube (for high particulate with cover) 180 14 4 - Rc 1/4 with plug int thd. 5 Blow down air inlet Select an upper port to avoid the condensation in the piping 8 - 19 MTG. holes 67 29 .5 Flange: JIS 5K80A FF ZFK MTG. position Packing 50 (175) ZFK5R Gas outlet (800) 790 4-6E3 5 7 1 30 Cord 11th L (m) 3 0.3 5 7 1 Z MASS 7.1 Approx.(kg) Gas flow L= 9.0 11.4 13.6 (to order) 0.5 0.75 1.0 Protection tube (65A SCH40) (38) Tube (50A SCH40) 11 ZFK, ZRM Converter (ZRM) Panel flush mounting Pipe mounting 204 193 88.6 18 6 220 200 50 2B pipe for mounting ( 60.5 0.5mm) 194 9 Cable gland 35 EXTERNAL CONNECTION DIAGRAM 4-core Cable 6 5 3 4 2-core Cable 1 2 1 55 28 176 37 Wiring port, 3- 23. with rubber bushing 2 3 4 5 6 7 T.C 8 9 10 11 12 13 14 A.OUT Output signal AUX.IN Auxiliary input Zr.SIG Element input MENT BLOW HEAT Heater power supply Thermo- Maintenance Blow contact couple contact 15 16 17 18 19 20 21 22 23 24 25 26 27 N 28 L PE DXA DXB G D11 D12 DI ZV COM SV SG FG COM Serial Contact input POWER Calibrating gas communication contact Power supply Note (1) : The numbers 1 through 6 denote detector terminal No. for exclusive - special cables. (2) : M3 terminal screws are used for the terminal block. Ejector (ZTA) 4-M16 bolt Approx. L 190 P 170 Gas inlet 30 42.7 L [mm] 500 750 1000 1500 Viewed from P direction 140 (JIS 10K65ARF) 40 217 35 Blow -down air inlet (Rc1/4) Ejector air inlet (Rc1/4) 40 50 45 Detector (ZFK2) 105 8 Cable gland (A15C) 25 EXTERNAL CONNECTION DAIAGRAM 1 2 3 4 5 Caution on Safety Ejector air outlet (Rc1/4) AC power supply Heater temp.drop alam *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDSX3-113C 价格&库存

很抱歉,暂时无法提供与“EDSX3-113C”相匹配的价格&库存,您可以联系我们找货

免费人工找货