FCX – AX SERIES SMALL FLANGE REMOTE SEAL TYPE
PRESSURE TRANSMITTER
DATA SHEET
The FCX –AX Series small flange remote seal type pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of -the-art microprocessor technology to provide exceptional performance and functionality. Totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions.
FHW, FKW...3
FEATURES
1. Directly connectable to 1-1/2in and 2in flanges The transmitter is connectable to 1-1/2in and 2in pipes without a reducer. 2. Connectable to 1/2in and 3/4in pipes Use of direct mounting adapter allows the transmitter to be connected to the following process. 1/2in and 3/4in flanges Screw connection 1/2-14NPT, 3/4-14NPT, Rc1/2, Rc3/4 3. Minimum environmental influence The "Floating Cell" design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 4. Replaceable Communication Module Fuji micro-electronics manufacturing technology offers replaceable communication module that makes FCX–AX transmitter very unique in design. In case of change in communication protocl, all that needs to be done is just to replace the module and the transmitter gets upgraded to the new version. 5. Fuji/HART bilingual communication module The communication module is "bilingual" to speak both Fuji proprietary protocol and HART. Any HART compatible devices can communicate with FCX–AX series transmitters. 6. Application flexibility Various options that render the FCX–AX suitable for almost any process applications include: — Analog indicator at either the electronics side or terminal side — Full range of hazardous area approvals — Built-in RFI filter and lightning arrester — 41/2 -digits LCD meter — Stainless steel electronics housing — Wide selection of materials — High temperature, vacuum seals
7. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW hand Held Communicator (HHC) to comply with NAMUR NE43.
(Available for amplifier unit from version 24 and FXW(HHC) version 5.3.)
8. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
SPECIFICATIONS
Functional specifications
Type: Model FHW: Model FKW: Service: Span, range, and 4 to 20mA 4 to 20mA with digital signal Liquid, gas, or vapour overrange limit:
Range limit [kPa]{bar} Overrange limit [MPa] {bar} 4.5 {45} 15 {150}
Span limit [kPa]{bar}
Type
FHW F F W W 3 300 {3} 4 1000 {10}
Min. FKW 50 {0.5} 250 {2.5}
Max. FHW/FKW 3000 {30} 10000 {100}
–100 {–1 –100 {–1
to to to to
+3000 +30} 10000 100}
— Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: Atmospheric pressure — Conversion factors to different units; 1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi 1kPa=10mbar=101.9716mmH2O=4.01463inH2O Output signal: Model FHW: 4 to 20mA DC 2-wire Model FKW: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester.
EDSX5-74
Date Apr. 10, 1999
FHW, FKW...3
Load limitations: see figure below
[Ω]
“Output Underscale”: Approx. 3.8mA (Adjustable within the range 3.2mA to 3.8mA from HHC)
3.2 3.8 4 20 20.8 Over scale Burnout
2000
1533Ω
Load resistance
1500 1000 500 250 10
600Ω Operating area 24V 16.1 10.5V Power voltage 45V 50 [V]
0 Normal operating range Under scale Probable under range Burnout
21.6 Probable over range
Note: For communication with HHC (Model: FXW), min. of 250Ω is required.
Hazardous locations: (Approval pending)
Authorities BASEEFA Factory Mutual RIIS Flameproof Ex ds IIC T5, T6 Class I II III Div. 1 Groups B thru. G Ex ds IIB+H2 T4 Intrinsic safety EEx ia IIC T4, T5 Class I II III Div. 1 Groups A thru. F — Type N Nonincendive Ex N II T5 Class I II III Div. 2 Groups A thru. G —
Zero/span adjustment: Model FHW: Zero is adjustable from the external adjustment screw. The adjustment screw can also function to adjust span when MODE SWITCH (located on the electronics unit) is in the span mode. INHIBIT mode to disable the adjustment screw is also available. Model FKW: Zero and span are adjustable from the HHC. Zero is also adjustable externally from the adjustment screw. Damping: Adjustable electrical damping. Model FHW: The time constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. Model FKW: The time constant is adjustable between 0 to 38.4 seconds. Zero elevation/suppression: Zero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable by moving a jumper pin located on the electronics unit. Indication: Analog indicator or 4 1/2 -digit LCD meter, as specified. Burnout direction: If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. Model FHW: Unless otherwise specified in the order, the transmitter will be shipped in “Output Hold” mode. (Output signal just before failure happens is maintained.) Model FKW: Selectable from HHC “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Approx. 21.6mA (Adjustable within the range 20.8mA to 21.6mA from HHC)
Loop-check output: Model FHW: Transmitter can output constant signal of 4mA, 12mA, or 20mA if MODE SWITCH is set to the loop check mode. Model FKW: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC. Temperature limit: Ambient: – 15 to +65°C (– 15 to +60°C for arrester option) (–10 to +60°C for fluorinated oil fill transmitter) (–10 to +60°C for silicone oil "H", "S") For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process:
Fill fluid Fluorinated oil Silicone oil 13th digit of "Code symbols" W, A and D H Y and G S Process temperature –20 to 120°C 0 to 250°C – 40 to 120°C 0 to 250°C Lower limit of static press. Atmospheric pressure 2.7kPa abs {20mmHg abs}
Storage: – 40 to +70°C Humidity limit: 0 to 100% RH Communication: (Model FKW only) With HHC (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured.
Items Tag No. Model No. Serial No. Engineering unit Range limit Measuring range Damping Output mode Burnout direction Adjustment Output adjust Data Self diagnoses Printer External switch lock Transmitter display(*) Display Set
v v v v v v v v v v — v v — v v
v v — v — v v v v v v — — — v v
Note: (*) HHC's version must be more than 5.0 (or FXW 1– 2), to use this function.
2
Performance specifications
Accuracy rating: (including linearity, hysteresis, and re(Standard) peatability) For spans greater than 1/10 of URL: ± 0.25% of span For spans below 1/10 of URL (Model FKW only): ± 0.17+0.08 0.1 x URL % of span Span (Option) For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL (Model FKW only): ± 0.05+0.05 0.1 x URL % of span Span Linearity: 0.1% of calibrated span Stability: ± 0.2% of upper range limit (URL) for 24 months Temperature effect: Effect per 28°C change between the limits of – 15°C and +65°C Zero shift: ± 0.5%/28°C (x equal to 1/6.5 URL or more) URL Zero shift; ± (0.5 )%/28°C 6.5 x x (x less than 1/6.5 URL) Total shift; ± 0.75%/28°C (x less than 1/6.5 URL or more) URL Total shift; ± (0.25 + 0.5 )%/28°C 6.5 x x (x less than 1/6.5 URL) Where, x: Calibrated span
Physical specifications
Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 x 1.5 conduit, as specified. Process connections: JIS; 10K, 20K, 30K, 63K –40, 50A 10K, 20K, 30K, 63K –15, 20A (with Adapter) ANSI/JPI; 150LB, 300LB, 600LB, –1 1/2 ", 2" 150LB, 300LB, 600LB, –1/2", 3/4" (with Adapter) Screw connection (with Adapter) ; Rc1/2, Rc3/4, 1/2-14NPT, 3/4-14NPT Diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (See model code. Extended diaphragm is available only with 316L stainless steel diaphragm) Process-wetted parts material: Diaphragm: 316L stainless steel, Hastelloy-C Monel or Tantalum Flange face: 316 stainless steel, Hastelloy-C lining Monel lining or Tantalum lining Extension: 316 stainless steel (Refer to "Code symbols") Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy (standard), finished with polyester coating, or 316 stainless steel (SCSI4 per JIS G5121), as specified. Capillary: In case of 13th code "Y. W. G. A. D", PVC armored stainless steel. In case of 13th code "H. S", stainless steel armored stainless steel. Mounting flange: (option) 304 stainless steel or carbon steel Fill fluid: Silicone oil (standard) or fluorinated oil (Daifloil) Mounting bracket: Carbon steel with epoxy coating or 304 stainless steel, as specified Environmental protection: IEC IP67 and NEMA 4X Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting Mass {weight}: Transmitter approximately 10kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm
( (
) )
Maximum span (Upper Range Limit) Note 1: Condition: Capillary length: 3m max. In case the capillary length is 5m, the performance becomes 1.5 times worse than above. Note 2: In case the 7th code (material code) is other than W, A, B, C or D, the performance becomes 2.5 times worse than above. Note 3: Above specifications are based on the conditions that flange and sensor unit are at the same temperature and in the same level. If temperature is different at flange, capillary or sensor unit, output variation may increase.
URL:
Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL) Supply voltage effect: Less than 0.05% of calibrated span per 10V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. Step response: Time constant: 0.3s (with 1.5m capillary) Dead time: approximately 0.3s (without electrical damping) Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ/500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less
3
FHW, FKW...3
Optional features
Indicator: A plug-in analog indicator (1.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 41/2 digits LCD meter is also available.
ACCESSORIES
Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS8-47) Communication module: (Standard for FKW) By adding communication module, remote setting function becomes available for model FHW.
Remark: When the communication module is connected, the operation mode of external zero/span adjustment screw is limited to zero adjustment only.
A built-in arrester protects the electronics from lightning surges. Lightning surge immunity is 4kV (1.2 x 50µs). Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: Oil-free procedures as above. Includes fluorinated oil for fill. Not available with material code “W”. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Vacuum and high temperature service: Special silicone oil and filling procedure are applied. See below figure.
Filled liquid: Silicone (Code Y,G) Silicone (Code S)
Arrester:
[kPa abs] {m bar abs}
101 {1010}
Operating pressure
53.3 {533}
Operating area
13.3 {133}
2.7 {27}
Non-operating area
–40 0
60 85 120 Process temperature
200 230 250 [°C ]
The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TN510412. The applicable standards used to demonstrate compliance are :EMI (Emission) EN50081-1 : 1992
Test item Applicable Electromagnetic Radiation Disturbance Frequency range 30-1000MHz Basic standard EN55022 Class B
Fig. 1 Relation between process temperature and operating pressure
Customer tag: Coating of cell:
A stainless steel tag for customer tag data is wired to the transmitter. Cell's surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive.
EMS (Immunity)
No. 1 Test item Electrostatic discharge
EN50082-1 : 1992
Test specification 8kV (Air) Basic standard IEC 801-2:1984 Performance criteria B
2
Radio-frequency 27-500MHz electromagnetic 3V/m IEC 801-3:1984 field. (Unmodulated) Fast transients common mode 0.5kV, 5/50 (Tr/Th) ns 5kHz Rep. IEC 801-4:1988
A
3
B
"LVD - The transmitter is not covered by the requirements of the LVD standard."
4
CODE SYMBOLS
12345678 9 10 11 12 13 14 15 16 17 18 19 20
F
W
3
0
Description Type 4 to 20mA, Output type 4 to 20mA with digital signal, Output type
FHW FKW S T V W
Conduit connection G 1/2 1/2 - 14NPT Pg 13.5 M20 X 1.5 Flange Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2" ANSI/JPI 600LB 2" Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2" ANSI/JPI 600LB 2" None 40A, 1 1/2B (Wafer type) 50A, 2B Direct mounting adapter connection (* 1) Span limit [kPa] {m bar} FHW FKW 300...3000 (3..30) 50...3000 ( 0.5...30) 1000..10000 (10...100) 250...10000 (2.5...100) Material/diapharagm extension Diaphragm W A B C D H M T Flange face Diaphragm extension (mm) 0 50 100 150 200 0 0 0
0 1 2 3 4 5 6 7 A B C D E F G H J K L M N P Q R S T U V W X Y
3 4
316L stainless steel 316 stainless steel
(* )
2
Hastelloy-C Monel Tantalum
Hastelloy-C Monel Tantalum
Note 1: Direct mounting adapter type is specified at 16th to 20th digit. Direct mounting adapter is available only for 7th digit code "W". 2: Diaphragm extension is available only for 2" (50A) flanges.
5
FHW, FKW...3
12345678 9 10 11 12 13 14 15 16 17 18 19 20
F
W
3 Indicator and arrester Indicator None Analog, 0 to 100% linear scale Analog, custom scale Analog, double scale None Analog, 0 to 100% linear scale Analog, custom scale Analog, double scale Digital, 0 to 100% Digital, custom scale Digital, 0 to 100% Digital, custom scale A B C D M N H K P
Description Arrester None None None None Yes Yes Yes Yes None None (Model FKW only) Yes Yes (Model FKW only)
A B D J E F H K L P Q S
Approvals for hazardous locations (Approval pending) None (for ordinary locations) JIS, Flameproof (Conduit seal) (Available for 4th digit code "S") JIS, Flameproof (Cable gland seal) (Available for 4th digit code "S") FM, Flameproof (or explosionproof) (Available for 4th digit code "T") BASEEFA, Flameproof (Conduit seal) BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only) FM, Intrinsic safety and Nonincendive CENELEC, Intrinsic safety CENELEC, Intrinsic safety and BASEEFA, Type N Capillary and mounting bracket mounting bracket A B G D E L Carbon steel Capillary 1.5m 3m 5m 1.5m 3m 5m Coating of cell None None None None Yes Yes Yes Yes
Stainless steel
Y B C E M N P Q
Stainless steel parts Stainless steel tag plate Stainless steel elec. housing None None Yes None None Yes Yes Yes None None Yes None None Yes Yes Yes Treatment/Fill fluid Treatment Y W G A D H S Y C Y A B E None None Degreasing Oxygen service Chlorine service High temp. 250°C High temp. and vacuum (250°C) Fill fluid
Silicone oil (for general use) Fluorinated oil Silicone oil Fluorinated oil (7th digit code "W", "A", "B", "C" and "D") Fluorinated oil (7th digit code "H" and "T") Silicone oil (7th digit code "W", "A", "B", "C" and "D") Silicone oil
}
Teflon membrane None Yes (7th digit code "W", "H", "M", and "T") Bolt/nut None Standard (Cr-Mo alloy hexagon socket head cap bolt/ carbon steel nut) Cr-Mo alloy hexagon bolt/carbon steel nut 304 stainless steel bolt/304 stainless steel nut 6th digit code "3" 6th digit code "4"
Odering information
1. When odering this instrument, specify the output orientation (burnout direction) in case of abnormality in the transmitter. Unless otherwise specified, the output hold function is supplied.
6
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4") connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify "Y" in the 5th digit of Code Symbol, and specify 16th digit to 20th digits. When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digits. 2. Unless otherwise described in the specifications, leave the 21st digit blank.
12345678 9 10 11 12 13 14 15 16 17 18 19 20
F
W
3 1 1 2 2 3 3 6 6 1 1 2 2 4 4 S S S S 1 2 1 2 1 2 1 2 H T H T H T R 2 N T
Description Process connection (direct mounting adapter) JIS 10K 15A JIS 10K 20A JIS 20K 15A JIS 20K 20A JIS 30K 15A JIS 30K 20A JIS 63K 15A JIS 63K 20A ANSI/JPI 150LB 1/2" ANSI/JPI 150LB 3/4" ANSI/JPI 300LB 1/2" ANSI/JPI 300LB 3/4" ANSI/JPI 600LB 1/2" ANSI/JPI 600LB 3/4" Screw connection Rc1/2 Screw connection Rc3/4 Screw connection Rc1/2 - 14NPT Screw connection Rc3/4 - 14NPT Material (direct mounting adapter) Adapter W G N 1 2 Bolts/nuts (* 1) 316 Stainless Steel Cr-Mo steel/carbon steel Vent/drain (for direct mounting adapter) Standard Long type Gasket (for direct mounting adapter) Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit). For high temperature (spiral gasket) (Only H and S can be specified on 13th digit). *1 For connection of transmitter receiving pressure unit and direct mounting adapter
7
FHW, FKW...3
Fastener (In case of 10th digit code “B,C,M,N”) Zero/span adj. screw In case of 4th digit code “S,V,W,X” U - bolt M8 MTG. pipe JIS 50A (2")
Up
φ 80 110 104 70 88 50
Down
30 38 4 holes 9 dia.
“A” Conduit conn. Cable gland (option) See note N holes h dia. Detail “A” (Conduit conn.)
71
224 “B” Conduit conn.
58
Inner of gasket Detail “B”
φ 48 φ 49 φ 84 φE φD 17
φ 15
KM
φ 13
Earth terminal (both side) See table 1
51
71 191
(27) J See table 1 G1/2 t 20 L
φ 80
With field ind. (option)
7th digit of Code symbols W, H, M, T A B C D
L 0 50 100 150 200
Mass approx. [kg] 9.5 10.5 11.5 12 12.5
11th digit of Capillary code symbols length S [mm] A,D B, E G, L 1500 3000 5000
252
S 2-M8 × 12
5th digit of code symbols φ D φ E 0, G 50 70 120 1, H 2, J 3, K 4, L 5, M 6, N Conduit conn. 4th digit of Code symbols J M K S T V W G1/2 1/2-14NPT Pg13.5 M20x1.5 17 16 8 16 Table 1 8 5 4.5 5 7, P Earth terminal No. 8-32UNC M4 M4 M4 A, Q B, R C, S D, T E, U F, V 140 105 155 120 140 105 155 120 160 120 165 130 175 130 185 145 127 98.4 156 114.3 165 127 165 127
t 36 36 38 38 42 42 52 54
N-φ h 4-19 4-19 4-19 8-19 4-23 8-19 4-25 8.23
Flange JIS-10K-40A JIS-10K-50A JIS-20K-40A JIS-20K-50A JIS-30K-40A JIS-30K-50A JIS-63K-40A JIS-63K-50A ANSI/JPI-150LB-1 1/2" ANSI/JPI-150LB-2" ANSI/JPI-300LB-1 1/2" ANSI/JPI-300LB-2" ANSI/JPI-600LB-1 1/2" ANSI/JPI-600LB-2"
37.5 4-16 41 4-23
152 120.6 39.5 4-20 42.5 8-20 45.5 8-20
156 114.3 42.5 4-23
Note *: Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable.
CONNECTION DIAGRAM
Inner of gasket 2-M6 screw depth 9
+ – CK + CK –
φ 84 φ 49
71
75
+–
20 20
Note: In case of wafer type, flange is excluded from the scope of supply. Mount flange, referring to the view.
S H F KWT V W
0 1 2 3 4 5 6
3
8
OUTLINE DIAGRAM (Unit:mm)
Fastener (In case of 10th digit code “B,C,M,N”) Zero/span adj. screw In case of 4th digit code “S,V,W,X” U - bolt M8 MTG. pipe JIS 50A (2")
Up
φ 80 110 104 70 88 50
Down
30 38 4 holes 9 dia.
“A” Conduit conn. Cable gland (option) See note Specifications for instrument with direct mounting adapter N holes H dia. t Detail “A” (Conduit conn.) φ 15
KM
224 “B” Conduit conn.
58
80
20
Detail “B” φ 13
S
φD
φE
φF
17
J See table 1
G1/2
(102) 25
(6.4) In case of ANSI/JPI-600LB flange With field ind. (option) 51 71 191 (27) (T) In case of ANSI/JPI-600LB flange Vent/drain plug Long vent/drain plug (added specification)
φ 80
Earth terminal (both side) See table 1
Table 1 4th digit of
252
Conduit conn. K 17 16 8 16 M 8 5 4.5 5
φ 84
Code symbols J S T
2-M8 × 12
Earth terminal M4 No. 8-32UNC M4 M4
11th digit of code symbols A,D B, E G, L
S 1500 3000 5000
G1/2 1/2-14NPT Pg13.5 M20x1.5 17th digit of 1 2 1 2 1 2 1 2 H T H T H T
V W 16th digit of
50 70 120
code symbols code symbols 1 1 2 2 3 3 6 6
øD 95 100 95 100 115 120 120 135 89 98 95 117 95 117
øE 70 75 70 75 80 85 85 95 60.3 69.9 66.7 82.5 66.7 82.5
øF 51 56 51 56 55 60 55 60
t 12 14 14 16 18 18 23 25
N-øh 4-15 4-15 4-15 4-15 4-19 4-19 4-19 4-23 4-16 4-20 4-20
Flange JIS-10K-15A JIS-10K-20A JIS-20K-15A JIS-20K-20A JIS-30K-15A JIS-30K-20A JIS-63K-15A JIS-63K-20A ANSI/JPI-150LB-1/2" ANSI/JPI-150LB-3/4" ANSI/JPI-300LB-1/2" ANSI/JPI-300LB-3/4" ANSI/JPI-600LB-1/2" ANSI/JPI-600LB-3/4"
CONNECTION DIAGRAM
+ – CK + CK –
+–
S H F KWT Y V W
3
1 2 3 4 6
1 1 2 2 4 4
34.9 11.5 4-16 42.9 13 42.9 16 42.9 16 34.9 14.5 4-16 34.9 14.5 4-16
Note *: Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable.
9
FHW, FKW...3
OUTLINE DIAGRAM (Unit:mm)
Fastener (In case of 10th digit code “B,C,M,N”) Zero/span adj. screw In case of 4th digit code “S,V,W,X” U - bolt M8 MTG. pipe JIS 50A (2")
UP
φ 80
110
104
DOWN
88
50
30 38 4 holes 9 dia.
“A” Conduit conn. Detail “A” (Contuit conn.) φ 15 Detail “B” φ 13 Cable gland (option) See note “B” Conduit conn.
224
58
KM
17
J See table 1 Earth terminal (both side) See table 1
G1/2 With field ind. (option) 51 71 191 (27) Press. conn. "D"
23
20 S
φ 80
φ 84
Long vent/drain plug
(102)
252
25
Long vent/drain plug (option)
2-M8 × 12
Specifications for instrument with direct mounting adapter (screw connection type)
Table 1
50 70 120
4th digit of Code symbols S T V W
Conduit conn. J G1/2 K 17 M 8 5 4.5 5
Earth terminal M4 No. 8-32UNC M4 M4
11th digit of code symbols A,D B, E G, L
S 1500 3000 5000
1/2-14NPT 16 Pg13.5 M20x1.5 8 16
CONNECTION DIAGRAM
16th digit of code symbols 17th digit of code symbols S S S R N 2 Press. conn. "D" Rc 1/2 1/2 - 14NPT Rc 3/4
+ – CK + CK –
+–
3/4 - 14NPT S T Note *: Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable.
S H TY F KW V W
3
S
Head office
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan Phone: 81-3-5435-7111 http://www. fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm
Sales Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187, 6189
Information in this catalog is subject to change without notice.
Printed in Japan
70