0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EDSX5-80K

EDSX5-80K

  • 厂商:

    FUJI(富士电机)

  • 封装:

  • 描述:

    EDSX5-80K - PRESSURE TRANSMITTER - Fuji Electric

  • 详情介绍
  • 数据手册
  • 价格&库存
EDSX5-80K 数据手册
PRESSURE TRANSMITTER DATA SHEET The FCX – A 2 p ressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FKG...4 FEATURES 1. High accuracy ± 0.07% 0.07% accuracy is a standard feature. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART ® b ilingual communications protocol and FOUNDATION™ fieldbus and Profibus™ compatibility FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–A2 . Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available. 4. Application flexibility Various options that render the FCX – A2 suitable for almost any process applications include: – Analog indicator at either the electronics side or terminal side – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing 5. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 6. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Span, range and overrange limit: Span limit [kPa] {bar} Type Min. F KG 01 F KG 02 F KG 03 F KG 04 F KG 05 1.3 {0.013} 5 {0.05} 30 {0.3} 100 {1} 500 {5} Max. 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} Range limit [kPa] {bar} Lower limit –100 {–1} –100 {–1} –100 {–1} –100 {–1} –100 {–1} Upper limit 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} Overrange limit [MPa] {bar} 1 {10} 1.5 {15} 9 {90} 15 {150} 75 {750} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at below 60°C – Conversion factors to different units; 1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi 1kPa=10mbar=101.9716mmH2O =4.01463inH2O Output signal: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. EDSX5-80k Date Mar. 7, 2007 FKG...4 Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below [Ω] 2000 Load resistance Authorities ATEX Intrinsic safety Ex II 1 GD EEx ia IIC T5 Tamb = –40°C to +40°C EEx ia IIC T4 Tamb = –40°C to +80°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.134mH 1533Ω 1500 1000 500 250 0 10 Factory Mutual 600Ω Operating area 24V 16.1 10.5V Power voltage 45V 50 [V] Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X Model code 9th digit A,B,D L,P,1,2 Q,S,4,5 E,F,H – 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C Note: For communication with HHC (1) ( Model: FXW), min. of 250 Ω required. Entity Parameters: Vmax=42.4V, Imax=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=32.6nF, Li=1.134mH Ex ia IIC T4 IP66/67 Tamb = –40°C to +70°C Ex ia IIC T5 IP66/67 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=0.033µF, Li=1.034mH Hazardous locations: Authorities ATEX Flameproof Ex II 2 GD EEx d IIC T6 IP66/67 T85°C Tamb = – 40°C to +65°C EEx d IIC T5 IP66/67 T100°C Tamb = – 40°C to +85°C Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C Class I Div.1 Groups C, D Class II Div.1 Groups E, F, G Class III Div.1 Note) “Seal Not Required” enclosure is allowed. TIIS Ex do IIB+H2 T4 Tamb max = +55°C Maximum process temp. = +120°C Ex d IIC T5 IP66/67 pending Tamb = – 40°C to +85°C Ex d IIC T6 IP66/67 pending Tamb = – 40°C to +65°C Factory Mutual TIIS CSA IECEx Scheme /SAA IECEx Scheme /SAA 2 Authorities ATEX Type n Nonincendive Ex II 3 GD EEx nL IIC T5 Tamb = –40°C to +40°C EEx nL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=27nF, Li=1.134mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH EEx nAL IIC T5 Tamb = –40°C to +40°C EEx nAL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W “Output Overscale”: Adjustable within the range 20.8mA to 21.6mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 3.8mA from HHC 3.2 3.8 4 20 20.8 21.6 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Factory Mutual Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 9th digit A,B,D L,P,1,2 Q,S,4,5 E,F,H – 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C CSA Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH – TIIS IECEx Scheme /SAA – Loop-check output: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC. Temperature limit: Ambient: – 40 to +85°C (–20 to +80°C for LCD indicator) (– 40 to +60°C for arrester option) (–10 to +60 ° C for fluorinated oil fill transmitter) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process: – 40 to +100 °C for silicone fill sensor –20 to +80°C for fluorinated oil fill sensor Storage: –40 to +90°C Humidity limit: 0 to 100% RH Communication: With HHC(1) ( Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Note: HHC’s version must be more than 6.0 (or FXW 1– 3), for FCXA2. Items Tag No. Model No. Serial No. Engineering unit Range limit Measuring range Damping Output mode Burnout direction Calibration Output adjust Data Self diagnoses Printer External switch lock Transmitter display Linearize Rerange Display Set Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code “L, P, Q, S”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 seconds. Zero elevation/suppression: Zero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable from HHC(1). Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. v v v v v v v v v v — v v — v v v v v v — v — v v — v v v — — — v v v v EMC Conformity: EN61326 (Note) (1) HHC: Hand Held Communicator 3 FKG...4 Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Physical specifications Electrical connections: G1 /2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. 1-port (standard) or 2-port with each conduit, as spcified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. Meet DIN 19213 Process-wetted parts material: Material code (7th digit Process cover in Code symbols) V J 316 stainless steel(*1) 316 stainless steel(*1) Wetted sensor body Accuracy rating: (including linearity, hysteresis, and repeatability) Max span below 10000kPa model: For spans greater than 1/10 of URL: ± 0.07% of span For spans below 1/10 of URL: 0.1 × URL ± 0.02+0.05 % of span Span Max span 50000kPa model: For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.1% of upper range limit (URL) for 3 years. Temperature effect: Effects per 28°C change between the limits of –40°C and +85°C URL Zero shift: ± (0.075+0.0125 span )% URL Total effect: ± (0.095+0.0125 span )% Overrange effect: Zero shift; 0.2% of URL for any overrange to maximum limit Supply voltage effect: Less than 0.005% of calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Update period: 120 msec *) Step response: Time constant: 0.2s *) Dead time: approximately 0.2s *) (without electrical damping) ( ( ) ) Diaphragm Vent/drain H M T B L U 316L stainless steel 316L stainless steel +Au coating 316 stainless Hastelloy-C steel(*1) 316 stainless Monel steel(*1) 316 stainless Tantalum steel(*1) Hastelloy-C Hastelloy-C lining Monel lining Monel Tantalum Tantalum lining 316 stainless steel 316 stainless steel Hastelloy-C lining Monel lining Tantalum lining Hastelloy-C lining Monel lining Tantalum lining 316/316L stainless steel 316/316L stainless steel 316/316L stainless steel 316/316L stainless steel 316/316L stainless steel Hastelloy-C Monel Hastelloy-C Note: (*1) SCS14A per JIS G 5121 (equivalent CF8M per ASTM A351/A351M) Remarks: Sensor O-rings: Viton O-ring and teflon gasket selectable Availability of above material design depends on ranges. Refer to “Code symbols”. *) Faster response is available as option (maximum update rate: 25 times per second). Mounting position effect: Zero shift, less than 0.1kPa {1m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (standard), or 316 stainless steel (SCS14A per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), or 304 stainless steel (630 stainless steel for 50MPa unit). Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass {weight}: Transmitter approximately 3.4kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 4 Optional features A plug-in analog indicator (2.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 5-digit LCD meter with engineering unit is also available. Local adjustment unit with LCD display: An optional 5-digit LCD meter with Zero/ Span adjustment function, loop-check function and damping adjustment function, is available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Vacuum service: Special silicone oil and filling procedure are applied. See Fig.1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/polyurethane double coating. Specify if environment is extermely corrosive. Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} Operating pressure Operating area 20 {200} ACCESSORIES Oval flanges: (Model FFP, refer to Data Sheet No. EDS6-10) Converts process connection to 1 /2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS8-47) Z/S board: Parts No.=ZZPFCX4-A070 When Z/S board is mounted on the FCX– A2 a mplifier unit, external adjustment screw will be available for zero and span adjustment. The product conforms to the requirements of the Electromagnetic compatibility Directive 94/9/EC as detailed within the technical construction file number TN513035. The applicable standards used to demonstrate compliance are : EMI (Emission) Frequency range MHz 30 to 230 230 to 1000 Indicator: EN61326 : 1997 Class A (standard for Industrial Location) Limits 40dB (µV/m) quasi peak, measured at 10m distance 47dB (µV/m) quasi peak, measured at 10m distance Reference standard CISPR16-1 and CISPR16-2 EMI (Immunity) Phenomenon Electrostatic discharge EN61326: 1997 Annex A (standard for Industrial Location) Test value Basic standard EN61000-4-2 Performance criteria B 4kV (Contact) 8kV (Air) 80 to 1000MHz Electromagnetic 10V/m field 80%AM (1kHz) Rated power frequency magnetic field Burst 30A/m 50Hz 2kV 5kHz 1.2µs/50µs 1kV (Line to line) 2kV (Line to ground) 0.15 to 80MHz 3V 80%AM (1kHz) EN61000-4-3 A EN61000-4-8 A EN61000-4-4 B Surge EN61000-4-5 B Conducted RF EN61000-4-6 A Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. 4 {40} 2.7 {27} –40 None-operating area –15 60 85 120 Process temperature[°C ] Fig. 1 Relation between process temperature and operating pressure 5 FKG...4 CODE SYMBOLS 12345678 9 10 11 12 13 14 15 21 Digit 4 Description Oval flange Process screw connection 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF Process cover Span limit [kPa]{bar}(*2) 316 stainless steel 1.3…130 316 stainless steel {0.013…1.3} 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel Conduit connection G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 Diaphragm 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Note F KG 0 4 Digit No. of code (×1) (×1) (×1) (×1) (×1) (×2) (×2) (×2) (×2) (×2) Combination with 12th digit code "C, E, P, Q" are not available. Note 1 Note 1 Note 1 Note 1 A B C D E S T V W X 6, 7 Wetted cell body Note 2 316 stainless steel 316 stainless stee Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless stee Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless stee Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 1V 1J 1H 1M 1T 1B 1L 1U 2V 2J 2H 2M 2T 2B 2L 2U 3V 3J 3H 3M 3T 3B 3L 3U 4V 4J 4H 4M 4T 4B 4L 4U 5V 5J 5…500 {0.05…5} 30…3000 {0.3…30} 100…10000 {1…100} 500…50000 {5…500} 9 Indicator None Analog, 0 to 100% linear scale Analog, custom scale None Analog, 0 to 100% linear scale Analog, custom scale Digital, 0 to 100% Digital, custom scale Digital, 0 to 100% Digital, custom scale Digital, 0 to 100% (Local adjustment unit with LCD display) Digital, custom scale (Local adjustment unit with LCD display) Digital, 0 to 100% (Local adjustment unit with LCD display) Digital, custom scale (Local adjustment unit with LCD display) Arrester None None Z/S board None attached. Yes Yes Yes None None Yes Yes None A B D E F H L P Q S 1 2 None 4 Yes 5 Yes Note 1 : (*1) Note 2 : (*2) For 50MPa {500bar} units, M12 is provided rather than M10. 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. 6 12345678 9 10 11 12 13 14 15 21 Digit 10 11 12 13 14 15 21 Description Note None (for ordinary locations) TIIS, Flameproof (Conduit seal) (Available for 4th digit code "A", "S") TIIS, Flameproof (Cable gland seal) (Available for 4th digit code "A", "S") FM, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") CSA, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") ATEX, Flameproof IECEx Scheme/SAA, Flameproof (Approval pending) TIIS, Intrinsic safety FM, Intrinsic safety and Nonincendive CSA, Intrinsic safety and Nonincendive ATEX, Intrinsic safety ATEX, Type n IECEx Scheme/SAA, Intrinsic safety FM, Combined of Flameproof and Intrinsic safety Vent/drain Mounting bracket Standard None Specify "A", or "C" for the 7th Standard Yes, stainless steel digit code "B", "L", or "U" Side None Side Yes, stainless steel Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Note3 (*3) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "J" only) Chlorine service Fluorinated oil (7th digit code "H", "T" ,"B", "U") NACE specification Silicone oil (Not available for 6th digit code "5", 7th digit code "T", "U", 15th digit code "A", "B") Vacuum service Silicone oil for vacuum use Viton (O-ring) Teflon (gasket) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) Not available for 6th digit NACE bolt/nut (ASTM A320 L7M/A194 2HM) code "5" 304 stainless steel bolt/304 stainless steel nut 630 stainless steel bolt/304 stainless steel nut Available for 6th digit code "5" (*4) Note4 Instruction manual unattached Costomer tag number can be engraved on standartd stainless steel name plate. If extra tag plate is required, select "Yes". If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. F KG 0 4 A B C D E X R G H J K P T V Digit No. of code A C D F Y B C E M N P Q Y W G A D N R A B A B C D E F L Note 3 : (*3) Note 4 : (*4) 7 FKG...4 ORDERING INFORMATION When ordering this instrument, specify. 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occured in the transmitter. Hold/Overscale (21.6mA)/Overscale (3.2mA) Unless otherwise specified, output hold function is supplied. 4. Indication method (indicated value and unit) in case of the actual scale (code D,H,P,S on 9th digit). 5. Tag No.(up to 26 alphanumerical characters), if required. 8 OUTLINE DIAGRAM (Unit:mm) < 7th digit code : V, J, H, M, T, J > Vent/drain plug (When the vent/drain plug attatched on the upper side of the detector) Note2) In case of 4th digit code “A.B.C.D.E” In case of 4th digit code “S.V.W.X” Fastener (Flameproof only) “A” Press. conn. MTG. Pipe JIS 50A (2B) In case of 4th digit code “T” Zero ADJ. screw 94.5 10 8 105 130 120 43.5 Up 105 φ80 70 52.5 Down 41 U - bolt M8 58 4 holes 9 dia. 37 Note1) 210 (189) Vent / drain plug Note3) 88 38 (27) “B” Conduit conn. Cable gland (option) “C” Conduit conn. With field ind. (option) 154 Earth terminal Detail “A” (Press. conn.) φ18.5 H 2.5 Detail “B” (Conduit conn.) φ15 Detail “C” φ13 Electronics unit Oval flange screw See Table 1 41.3 Note3) 59 43 8 F 17 φ80 231 (210) Side vent (option) 27 70 104 54 E φ7 D See Table 1 See Table 1 G 1/2 Sensor unit 4-M8×12 4th digit of the code symbols A, S B, T C, V D, W E, X Conduit conn. D G1/2 E 17 F 8 5 4.5 5 4.5 Press. conn. H Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Oval flange screw 7/16-20UNF Screw depth 15 7/16-20UNF Screw depth 15 M10 Screw depth 15 M10 Screw depth 15 7/16-20UNF Screw depth 15 1/2-14NPT 16 Pg13.5 M20×1.5 Pg13.5 8 16 8 CONNECTION DIAGRAM + – CK+ CK– Table 1 + – Note1) Cable gland is supplied in case of flamproof packing type. φ11 cable is suitable. Note2) The pressure connector is located on the down side surface of the detector, when the vent / drainplug is attatched on the upper side of the detector. (When the 21st digit of the code symbols : C, E or D). Note3) In case of 6th digit code “5” 9 FKG...4 < 7th digit code : B, L, U > In case of 4th digit code “A.B.C.D.E” MTG. Pipe JIS 50A (2B) U - bolt M8 41.3 94.5 In case of 4th digit code “S.V.W.X” Fastener (Flameproof only) 10 In case of 4th digit code “T” Zero ADJ. screw 8 105 104 43.5 Up φ80 105 70 52.5 Down 41 58 4 holes 9 dia. 40 Cable gland (option) 213 (27) With field ind. Note) “C” Conduit conn. “D” Conduit conn. Detail “A” (Press. conn.) 2 -0.1 88 38 4th digit code “A,S” φ16 Detail “C” (Conduit conn.) φ15 Detail “D” φ13 Earth terminal 60 155 43 1 φ12 +0.2 +0.1 0 φ80 Electronics unit H φ4 E F G 1/2 234 Sensor unit Detail “B” 4th digit code “B, C, D, E, T,V,W,X” φ16 1/4-18NPT See Table 1 View from P Vent / drain plug 17 L.P. P 4-M8×12 10 H.P. Oval flange screw See Table1 41.3 4th digit of the code symbols A, S B, T C, V D, W E, X Conduit conn. E F H G1/2 17 8 5 4.5 5 4.5 Oval flange screw 7/16-20UNF Screw depth 15 7/16-20UNF Screw depth 15 M10 Screw depth 15 M10 Screw depth 15 7/16-20UNF Screw depth 15 1/2-14NPT 16 Pg13.5 M20×1.5 Pg13.5 8 16 8 98 φ4 “A” or “B” Press. conn. 54 70 120 CONNECTION DIAGRAM + – CK+ CK– Table 1 Note 1) Cable gland is supplied in case of flamproof packing type. φ11 cable is suitable. +– 10 11 FKG...4 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan
EDSX5-80K
该PDF文档是关于一款集成电路的详细资料,包括以下部分: 1. 物料型号:包含该集成电路的型号信息。

2. 器件简介:简要介绍该集成电路的功能和应用领域。

3. 引脚分配:列出了该集成电路的每个引脚的功能。

4. 参数特性:详细描述了该集成电路的电气参数和性能指标。

5. 功能详解:深入解释了该集成电路的工作原理和主要功能。

6. 应用信息:提供了该集成电路的典型应用场景和设计建议。

7. 封装信息:介绍了该集成电路的物理封装类型和尺寸。


这些信息对于电子工程师在设计和选择集成电路时非常重要。

如果您需要更详细的内容,请提供具体问题。
EDSX5-80K 价格&库存

很抱歉,暂时无法提供与“EDSX5-80K”相匹配的价格&库存,您可以联系我们找货

免费人工找货